Technical Specifications
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|
| 1 | 87 | 118 MHz - 136.975 MHz | 1.85 W | 6K00A3E | 44.0000000000
Hz |
Grant NotesOutput power listed is rated conducted; This device contains functions that are not operational in U.S Territories except as noted in the filing. This filing is only applicable for US operations. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 75%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. SAR compliance for body-worn operating configurations is limited to the specific belt-clip/holster/accessories tested for this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR levels are: Head: 0.76 W/kg for 75% Duty Cycle; Body: 1.36 W/kg for 75% Duty Cycle.