K8C1208LRosemount 1208A Level transmitter

Rosemount Tank Radar AB
Rosemount 1208A Level transmitter - FCC ID K8C1208L - Rosemount Tank Radar AB
Click to zoom

Application Details

Equipment Class
LPR - Level Probing Radar
Date of Grant
Dec 15, 2022
Application Purpose
Original Equipment
Date of Application
Dec 15, 2022
Equipment Note
Rosemount 1208A Level transmitter
Frequency Range
77000.00000000 - 81000.00000000
Company
Rosemount Tank Radar AB
Country
Sweden

Documents & Files

Select a file to view

Users Manual

↗
↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Reference Manual 00809-0100-7062, Rev AA June 2022 Rosemount ™ 1208A Level and Flow Transmitter Non-Contacting Radar Safety messages NOTICE Read this manual before working with the product. For personal and system safety, and for optimum product performance, ensure you thoroughly understand the contents before installing, using, or maintaining this product. For technical assistance, contacts are listed below: Customer Central Technical support, quoting, and order-related questions. • United States - 1-800-999-9307 (7:00 am to 7:00 pm CST) • Asia Pacific- 65 777 8211 North American Response Center Equipment service needs. • 1-800-654-7768 (24 hours a day — includes Canada) • Outside of these areas, contact your local Emerson representative. WARNING Failure to follow safe installation and servicing guidelines could result in death or serious injury. Ensure the transmitter is installed by qualified personnel and in accordance with applicable code of practice. Inspection and maintenance of this equipment shall be carried out by suitably trained personnel, in accordance with the applicable standards and code of practice. Use the equipment only as specified in this manual. Failure to do so may impair the protection provided by the equipment. Repair, e.g. substitution of components, etc. may jeopardize safety and is under no circumstances allowed. WARNING Process leaks could result in death or serious injury. Handle the transmitter carefully. Install and tighten process connectors before applying pressure. Do not attempt to loosen or remove process connectors while the transmitter is in service. WARNING Physical access Unauthorized personnel may potentially cause significant damage to and/or misconfiguration of end users’ equipment. This could be intentional or unintentional and needs to be protected against. Physical security is an important part of any security program and fundamental to protecting your system. Restrict physical access by unauthorized personnel to protect end users’ assets. This is true for all systems used within the facility. CAUTION Hot surfaces The transmitter and process seal may be hot at high process temperatures. Allow to cool before servicing. 2 Contents Chapter 1Introduction.............................................................................................................. 5 1.1 Using this manual........................................................................................................................ 5 1.2 Product certifications...................................................................................................................5 1.3 Open source licenses................................................................................................................... 5 1.4 Product recycling/disposal...........................................................................................................5 Chapter 2Transmitter overview.................................................................................................7 2.1 Measurement principle................................................................................................................7 2.2 Process characteristics.................................................................................................................7 2.3 Vessel characteristics...................................................................................................................8 2.4 Non-contacting radar technology................................................................................................8 2.5 Components of the transmitter.................................................................................................10 2.6 Easy integration with IO-Link..................................................................................................... 10 Chapter 3Mechanical installation............................................................................................ 13 3.1 Safety messages........................................................................................................................13 3.2 Installation considerations.........................................................................................................13 3.3 Bracket mounting......................................................................................................................18 3.4 Installing on a tank.....................................................................................................................25 Chapter 4Electrical installation................................................................................................29 4.1 Safety messages........................................................................................................................29 4.2 Prepare the electrical connections.............................................................................................29 4.3 Power up transmitter.................................................................................................................32 Chapter 5Configuration...........................................................................................................33 5.1 Safety messages........................................................................................................................33 5.2 Overview................................................................................................................................... 33 5.3 Connect the transmitter to the IO-Link...................................................................................... 33 5.4 Get started with your preferred configuration tool.....................................................................34 5.5 Perform the basic setup.............................................................................................................36 Chapter 6Operation and maintenance...................................…

Text truncated - open the document above for the full version.

Users Manual

Quick Start Guide 00825-0100-7062, Rev AA June 2022 Rosemount ™ 1208A Level and Flow Transmitter Non-Contacting Radar Contents About this guide...........................................................................................................................3 Installing on a tank.......................................................................................................................5 Prepare the electrical connections................................................................................................8 Power up transmitter.................................................................................................................10 Connect the transmitter to the IO-Link.......................................................................................11 Get started with your preferred configuration tool.....................................................................12 Perform the basic setup..............................................................................................................14 Quick Start GuideJune 2022 2Rosemount 1208A Level and Flow Transmitter 1 About this guide This Quick Start Guide provides basic guidelines for the Rosemount 1208A Level and Flow Transmitter. Refer to the 1208A Reference Manual for more instructions. 1.1 Safety messages WARNING Failure to follow safe installation and servicing guidelines could result in death or serious injury. Ensure the transmitter is installed by qualified personnel and in accordance with applicable code of practice. Use the equipment only as specified in this Quick Start Guide and the Reference Manual. Failure to do so may impair the protection provided by the equipment. Repair, e.g. substitution of components, etc. may jeopardize safety and is under no circumstances allowed. WARNING Process leaks could result in death or serious injury. Handle the transmitter carefully. Install and tighten process connectors before applying pressure. Do not attempt to loosen or remove process connectors while the transmitter is in service. WARNING Physical access Unauthorized personnel may potentially cause significant damage to and/or misconfiguration of end users’ equipment. This could be intentional or unintentional and needs to be protected against. Physical security is an important part of any security program and fundamental to protecting your system. Restrict physical access by unauthorized personnel to protect end users’ assets. This is true for all systems used within the facility. June 2022Quick Start Guide Quick Start Guide3 CAUTION Hot surfaces The transmitter and process seal may be hot at high process temperatures. Allow to cool before servicing. 1.2 Bracket mounting See the documentation supplied with the bracket kit. Quick Start GuideJune 2022 4Rosemount 1208A Level and Flow Transmitter 2 Installing on a tank 2.1 Mount the flange Procedure 1. Place a suitable gasket on the tank flange. 2. Place the flange over the gasket. 3. Tighten the bolts and nuts with sufficient torque for the flange and gasket choice. 4. Apply appropriate thread sealant to the transmitter threads. Note Only for NPT threaded tank connection. June 2022Quick Start Guide Quick Start Guide5 5. Install and hand tighten the transmitter. Note The gasket is necessary for the G threaded version only. 2.2 Mount the NPT threaded adapter Procedure 1. Apply appropriate thread sealant to the outer threads. 2. Mount the threaded adapter on the tank. 60 mm Quick Start GuideJune 2022 6Rosemount 1208A Level and Flow Transmitter 3. Apply appropriate thread sealant to the transmitter threads. 4. Install and hand tighten the transmitter. June 2022Quick Start Guide Quick Start Guide7 3 Prepare the electrical connections 3.1 Connector type M12 (A-coded) 3.2 Power supply The transmitter operates on 18-30 Vdc at the transmitter terminals. 3.3 Outputs The transmitter provides two configurable outputs: Output 1 Digital output / IO-Link mode Output 2 Digital output or active 4-20 mA analog output 3.4 Internal power consumption < 2 W (normal operation at 24 Vdc, no outputs) < 3.6 W (normal operation at 24 Vdc, digital and analog outputs active) 3.5 Wiring diagram Figure 3-1: Connection 4 1 3 2 BN W H BK BU 1 4 2 3 OUT2 L+ L OUT1/IO-Link Table 3-1: Pin Assignment Pin Wire color (1) Signal 1 BN BrownL+24 V 2 WH WhiteOUT2Digital output or active 4-20 mA analog output 3 BU BlueL-0 V 4 BK BlackOUT1/IO-Link Digital output or IO-Link mode (1) According to IEC 60947-5-2. Quick Start GuideJune 2022 8Rosemount 1208A Level and Flow Transmitter Figure 3-2: Example Circuits 2: OUT2 4: OUT1 4 1 3 2 BN WH BK BU L+ L A 2: O UT2 4: OUT1 4 1 3 2 BN W H BK BU L+ L C 2: O UT2 4: OUT1 4 1 3 2 BN WH BK BU L+ L D 4 1 3 2 BN WH BK BU L+ L 2: OUT2 4: OUT1 B A. 2 x Digital output PnP B. 2 x Digital output NpN C. 1 x Digital output PnP / 1 x Analog output D. 1 x Digital output NpN / 1 x Analog output June 2022Quick Start Guide Quick Start Guide9 4 Power up transmitter Procedure 1. Verify the power supply is disconnected. 2. Insert the M12 connector and screw tight. See the manufacturer’s instruction manual for recommended torque. 3. Connect the power supply. Quick Start GuideJune 2022 10Rosemount 1208A Level and Flow Transmitter 5 Connect the transmitter to the IO-Link IO-Link devices can be set using an IO-Link USB Communicator, through the IO-Link master, or via the PLC. Procedure Start the configuration software and connect the transmitter. Figure 5-1: Connection via the IO-Link USB Communicator Figure 5-2: Connection via the IO-Link Master Figure 5-3: Connection via the PLC June 2022Quick Start Guide Quick Start Guide11 6 Get started with your preferred configuration tool 6.1 IO-Link configuration tools Examples: • Rosemount IO-Link Assistant (available as accessory) • FDT ® frame applications, e.g. PACTware 6.2 Rosemount IO-Link Assistant 6.2.1 Get the latest IODD files The Rosemount IO-Link Assistant software checks and lets you download the latest IODD…

Text truncated - open the document above for the full version.

Users Manual

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`)8(67??V7(()8>9:I-)4R' VV]C1NX]XW@  a!     /T  X@A./U)> /6XVWbA87:?;9--/8??.766:)-</=?/>\./8/1^69I.-)887>97-9):;7+ 9;*9:I/):-.//:(6)?=8/@ V@1*): 9:?-7667-9):G7(=88/:-69;9-9:I>/B9(/9:7(()8>7:(/\9-.-./8/J=98/;/:-?), [XWXWZX?.766</9:?-7 66/>-)/:?=8/-./;7H9;=;?.)8-(98(=9-(=88/:-),-./?=**6+ (7::)-/H(//>`@Vb'@ ]@ A./9:?-766/8?.766=?/-./*)\/8()::/(-)8c78-M=;</80^4WXb;7:=,7(-=8/><+ dPU-);79:-79:-./0:(6)? =8/A+*/`e7:>[c87-9:I?G)89?8/?*):?9<6/-)/:?=8/-./ (.)?/:,/;76/*)\/8()::/(-)8();*69/?\9- .0:(6)?=8/A+*/`e7:>[c87-9:I?\./: ;7-/>\9-.-./;76/()::/(-)8*78-:=;</8YWWWWW[ZbV`<+f9:>/8@   " &    g&h " &   iE Fj   j kl &%" ijlmm A+*/5/?(89*-9): N)(7-9):d:>))8)8)=->))8=?/ U7H9;=;76-9-=>/[n[V,-@LVWWW;O Q*/87-9:I*8/??=8/ZX`@n-)`]@n*?9ILZX-)o]f78O ';<9/:--/;*/87-=8/ Z`W-)XY[pPLZ`W-)bWp4O d:?-7667-9):(7-/I)8+54?=**69/> 06/(-89(76?=**6+XbZ]W^>(G]@[q U79:??=**6+B)6-7I/,6=(-=7-9):? R7,/7-XbZ]W^>(rXWs c)66=-9):>/I8//V  g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`abcdcecfghijkdjklZ(')mm+)" #"#.n'") + +&o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` a+&$+!!$*!PQR#"&"!+$ V*(!+$!UR"$"*"$b"))%(X&!Y+) 1"(W! $!"))&0 & ! ++&$"!2!("$+1!"$!2&!!$+$ &&$+'(!S&!+&+'! S/TU1 '+&!L #$!"$1$!"))+&+#&"!S&!+&+'! S/TU"%1+$!"!"!OQGAZ_G ,QQV!)W+&OQGAZ_G,OOV'"cW VT)!&$"!)%(!d"$"*&(/* )"!+&%e!"$"&(f$ !&%Y"$""( "%1 +$!"!W   -#&g$!"##"&)!+$'+&" cY^/hf$ !&Y"$"""##)"1)" c"##"& ) &"+c#!)$-hc#)+!"!+$!" !+&g" c+$!+$ "$!i P)h"##"&)$ +!#"#&+ &1&+ ))"* )h"##"&)+!"#!&!+ !1&+ ))"*&…

Text truncated - open the document above for the full version.

Cover Letter(s)

Document Version 1.1 2020-10-30 LONG-TERM CONFIDENTIALITY REQUEST for Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 TO WHOM IT M AY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request Long-Term Confidentiality for the following product: For the product stated above, we request Long-Term Confidentiality for exhibits which contain Block Diagram, Operational Description, Parts List/Tune Up Info, Schematics, SDR Software/Security Info. The above exhibits contain ou r trade secrets and proprietary information that could be of benefit to o ur competitors. This information will not be publicly available. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Company Name: Phone: Company Address: Fax: E-mail: Contact Name: Signature: Signature Date: Check your GC here. Click Grantee Search. FCC I D: Grantee Code Equipment Product Code

External Photos

Annex A No.1-3759/21-01-01_Annex_A External photos of the Device Under Test This document is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Document authorized: Thomas Vogler Lab Manager Radio Communications CTC advanced GmbHUntertuerkheimer Str. 6-10 66117 Saarbruecken / Germany Phone: +49 681 5 98 - 0 Fax: +49 681 5 98 - 9075 web: ctcadvanced.com e-mail: [email protected] Photos Annex A Photo 1 Photo 2 2022-07-14Document 1-3759/21-01-01_Annex_A2/4 Photo 3 Photo 4 2022-07-14Document 1-3759/21-01-01_Annex_A3/4 Photo 5 - END OF DOCUMENT - 2022-07-14Document 1-3759/21-01-01_Annex_A4/4

ID Label/Location Info

1 B ORIGINALFORMAT A3 A 1 23 C B 23 A C 1:1 LAYOUTVÄGEN 1, 435 33 MÖLNLYCKE , SWEDEN A3 1 ST ANGLE THE COPYRIGHT/OWNERSHIP OF THIS DOCUMENT IS AND WILL REMAIN OURS. THE DOCUMENT MUST NOT BE USED WITHOUT AUTHORIZATION OR BROUGHT TO THE KNOWLEDGE OF A THIRD PARTY. CONTRAVENTION WILL BE PROSECUTED. ROSEMOUNT TANK RADAR AB, SWEDEN UNLESS OTHERWISE SPECIFIED: ALL DIMENSIONS ARE IN MILLIMETERS. REMOVE ALL BURRS AND SHARP EDGES. - GENERAL TOLERANCES - MACHINING: CASTING: WELDING: ISO 2768 ISO 8062 EN-ISO 13920 FINISH: SCALE TITLE DRAWING NO. ISSUESHEET ISSUED BY APPROVED BY APP'D WEEK DRAWN WEEKPRODUCT CODE DOC TYPE ANGLES: Adobe Illustrator DO NOT SCALE PRINT PC-AA 22201208 0 AB 1/3 01208-6000 01208-6000 CERTIFIED PRODUCT No modification permitted without approval from the Authorized Person(s). REVISION DESCRIPTION ECO NO.APP'DDATE AB RTC EMe2245 ISSUED PC-AA ROSEMOUNT 1208 Main Label 7. THE PRODUCT IS NOT FOR USE WITH FLAMMABLE LIQUIDS 6. OUTLINES NOT TO BE PRINTED. 5. DO NOT PRINT BORDERS. 4. LABEL TO BE CUSTOMIZED ACCORDING TO FLEX CONTROLLED FIELDS 3. ALL APPROVAL LOGOS IN ACC. WITH RESP. LOGOTYPE. 2. TEXT TYPE: ARIAL NARROW BOLD & ARIAL BOLD 1. LASER ETCHED. 1208 MAIN LABEL K8C1208L 2827A-1208L 1208L1 K8C1208LB 2827A-1208LB 1208LB1 NO. FIELD MODEL PART NO. PART. REV. MARKING FORMAT 1. BASE LAYER 1208A,1208C -0001 AA According to base layer artwork illustration 2. CONNECTION 1208A -0201 AA DIAGRAM 3. WARNING 1208C -0301 AA 4. LOGOS 1208C -0401 AA 5. LOGOS 1208A -0501 AA 6. SUPPLY 1208A -0601 AA 1208C -0502 AA 1208C -0602 AB NO. FIELD SITE PART NO. MARKING FORMAT EXAMPLE FORMAT A MODEL ALL -FLEX <MODEL> 1208XX B SERIAL NO. ALL -FLEX <YYAABC1234567> 22BKRL0011234 C PRODUCTION ALL -FLEX <MM-YYYY> 03-2022 DATE D QR CODE ALL -FLEX <QR-CODE> LINKED TO MY ASSETS 1208C -0202 AA 1208C -0002 AA According to base layer artwork illustration 1208A,1208C -0704 AB 1208A -0902 AA 7. MADE IN 1208C -0703 AB 12 43 1 2 4 3 BN WH BK BU L+ OUT2: switch / 4...20mA OUT1: switch / IO-Link L- SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY. TO PREVENT IGNITION OF FLAMMABLE OR COMBUSTIBLE ATMOSPHERES, DISCONNECT POWER BEFORE SERVICING. INSTALL PER CONTROL DRAWING LA SUBSITUTION DE COMPOSANTS PEUT COMPROMETTRE LA SÉCURITÉ INTRINSÈQUE. POUR ÉVITER L’ALLUMANGE DE PRODUITS INFLAMMABLES OU ATMOSPHÈRES COMBUSTIBLES, DÉBRANCHEZ L’ALIMENTATION AVANT L’ENTRERIEN INSTALLER SELON LE SCHÉMA DE CONTRÔLE 18-30 VDC 3.6W HART® 4-20 mA 14-35 VDC 22.5mA 8501 2460 4 1 3 2 BN WH BK BU 1 4 2 3 NC L+ L NC 泰国制造 Made in Thailand 8. RADIO OUT. 1208A BT -0901 AA Rosemount™ 1208C Level and Flow Transmitter 1208C English 7000007-429 1208CN Rosemount™ 1208CN Level and Flow Transmitter 1208C Chinese 7000007-431 1208CNC Rosemount™ 1208C Level and Flow Transmitter 1208C English 7000007-428 1208CG Rosemount™ 1208A Level and Flow Transmitter 1208A English 7000007-396 1208AN Rosemount™ 1208A Level and Flow Transmitter 1208A English 7000007-395 1208AG Rosemount™ 1208CG Level and Flow Transmitter 1208C Chinese 7000007-430 1208CGC Description product variant Model Language Part Number Model string English LANGUAGE Chinese All All All All All All All All All All English Chinese K8C1208CLB 2827A-1208CLB 1208CLB1 1208C BT -0903 AA All K8C1208CL 2827A-1208CL 1208CL1 1208C -0904 AA All STRING CONTROLLED FIELDS FLEX CONTROLLED FIELDS 1 B ORIGINALFORMAT A3 A 1 23 C B 23 A C 1:1 LAYOUTVÄGEN 1, 435 33 MÖLNLYCKE , SWEDEN A3 1 ST ANGLE THE COPYRIGHT/OWNERSHIP OF THIS DOCUMENT IS AND WILL REMAIN OURS. THE DOCUMENT MUST NOT BE USED WITHOUT AUTHORIZATION OR BROUGHT TO THE KNOWLEDGE OF A THIRD PARTY. CONTRAVENTION WILL BE PROSECUTED. ROSEMOUNT TANK RADAR AB, SWEDEN UNLESS OTHERWISE SPECIFIED: ALL DIMENSIONS ARE IN MILLIMETERS. REMOVE ALL BURRS AND SHARP EDGES. - GENERAL TOLERANCES - MACHINING: CASTING: WELDING: ISO 2768 ISO 8062 EN-ISO 13920 FINISH: SCALE TITLE DRAWING NO. ISSUESHEET ISSUED BY APPROVED BY APP'D WEEK DRAWN WEEKPRODUCT CODE DOC TYPE ANGLES: Adobe Illustrator DO NOT SCALE PRINT PC-AA 22201208 0 AB 2/3 01208-6000 01208-6000 CERTIFIED PRODUCT No modification permitted without approval from the Authorized Person(s). REVISION DESCRIPTION ECO NO.APP'DDATE AB RTC EMe2245 ISSUED PC-AA ROSEMOUNT 1208 Main Label 7. THE PRODUCT IS NOT FOR USE WITH FLAMMABLE LIQUIDS 6. OUTLINES NOT TO BE PRINTED. 5. DO NOT PRINT BORDERS. 4. LABEL TO BE CUSTOMIZED ACCORDING TO FLEX CONTROLLED FIELDS 3. ALL APPROVAL LOGOS IN ACC. WITH RESP. LOGOTYPE. 2. TEXT TYPE: ARIAL NARROW BOLD & ARIAL BOLD 1. LASER ETCHED. 1208 MAIN LABEL 7 238.917 mm 117.941 mm 45 mm 238.917 mm 117.941 mm 45 mm BASE LAYER ARTWORK -0001 REV AA D B A C 2 3 4 5 6 BASE LAYER ARTWORK -0002 REV AA D B A C 2 3 4 5 6 7 8 8 Level and Flow Transmitter 1208 MODEL SERIAL Level & Flow TransmitterEMERSON | ROSEMOUNT DATE MFG: FCC ID: IC: HVIN: SUPPLY: ENCL. TYPE: MWP: 4X/6P, IP66/68, IK07 3 BAR Certificate Holder MÖlnlycke, Sweden Layoutvägen 1, 435 33 MÖlnlycke, SWE Rosemount Tank Radar AB Level and Flow Transmitter 1208 型号 出厂编号 液位 & 流量变送器 EMERSON | ROSEMOUNT 制造日期 FCC ID: IC: HVIN: 电源电压: ENCL. TYPE: MWP: 4X/6P, IP66/68, IK07 3 BAR 证书持有者 MÖlnlycke, Sweden Layoutvägen 1, 435 33 MÖlnlycke, SWE Rosemount Tank Radar AB 液位/流量变送器 1 B ORIGINALFORMAT A3 A 1 23 C B 23 A C 1:1 LAYOUTVÄGEN 1, 435 33 MÖLNLYCKE , SWEDEN A3 1 ST ANGLE THE COPYRIGHT/OWNERSHIP OF THIS DOCUMENT IS AND WILL REMAIN OURS. THE DOCUMENT MUST NOT BE USED WITHOUT AUTHORIZATION OR BROUGHT TO THE KNOWLEDGE OF A THIRD PARTY. CONTRAVENTION WILL BE PROSECUTED. ROSEMOUNT TANK RADAR AB, SWEDEN UNLESS OTHERWISE SPECIFIED: ALL DIMENSIONS ARE IN MILLIMETERS. REMOVE ALL BURRS AND SHARP EDGES. - GENERAL TOLERANCES - MACHINING: CASTING: WELDING: ISO 2768 ISO 8062 EN-ISO 13920 FINISH: SCALE TITLE DRAWING NO. ISSUE SHEET ISSUED BY APPROVED BY APP'D WEEK DRAWN WEEK PRODUCT CODE DOC TYPE ANGLES: Adobe Illustrator DO NOT SCALE PRINT PC-AA 22201208 0 AB 3/3 01208-6000 01208-6000 CERTIFIED PRODUCT No modification permitted without approval from the Authorized Person(s). REVISIO…

Text truncated - open the document above for the full version.

Internal Photos

Annex B No.1-3759/21-01-01_Annex_B Internal photos of the Device Under Test This document is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Document authorized: Thomas Vogler Lab Manager Radio Communications CTC advanced GmbHUntertuerkheimer Str. 6-10 66117 Saarbruecken / Germany Phone: +49 681 5 98 - 0 Fax: +49 681 5 98 - 9075 web: ctcadvanced.com e-mail: [email protected] Photos Annex B Photo 1 Photo 2 2022-07-14Document 1-3759/21-01-01_Annex_B2/10 Photo 3 Photo 4 2022-07-14Document 1-3759/21-01-01_Annex_B3/10 Photo 5 Photo 6 2022-07-14Document 1-3759/21-01-01_Annex_B4/10 Photo 7 Photo 8 2022-07-14Document 1-3759/21-01-01_Annex_B5/10 Photo 9 Photo 10 2022-07-14Document 1-3759/21-01-01_Annex_B6/10 Photo 11 Photo 12 2022-07-14Document 1-3759/21-01-01_Annex_B7/10 Photo 13 Photo 14 2022-07-14Document 1-3759/21-01-01_Annex_B8/10 Photo 15 Photo 16 2022-07-14Document 1-3759/21-01-01_Annex_B9/10 Photo 17 Photo 18 - END OF DOCUMENT - 2022-07-14Document 1-3759/21-01-01_Annex_B10/10

RF Exposure Info

SAR Test exemption documentation according to CFR 47 §1.1307 Report identification number: 1-3759/21-01-10 Exemption / MPE (FCC) contains the module with the following certification numbers FCC ID K8C1208L This test report is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Document authorised: Alexander Hnatovskiy Marco Scigliano Lab Manager Testing Manager Radio Communications & EMC Radio Communications & EMC Test report no.: 1-3759/21-01-10 Exemption / MPE (FCC) © CTC advanced GmbH Page 2 of 2 EUT technologies: Technologies: Max. rated power: (AVG) Max. gain: Level probing radar 77-81 GHz -32.42 dBm / 0.57μW <0 dBi Note: max. measured peak EIRP taken from CTC Advanced GmbH report 1-3759/21-01-08-A (page 24) (AVG factor -57.4 dB) Max. peak EIRP: 21.8 dBm AVG EIRP: -30.27 dBm, AVG ERP: -32.42 dBm Declared minimum safety distance: 20cm According the manual a safety distance of 20cm shall be applied between the user (and/or bystanders) to the EUT antenna whilst active transmitting. MPE-Based Exemption following 47 CFR 1.1307 amendment: If the declared ERP does not exceed the specified threshold based on the calculations below, the device is exempt from routine evaluation. Transmitter Frequency (MHz) Threshold ERP (W) 0.3 – 1.34 1.920 R² 1.34 – 30 3.450 R²/f² 30 – 300 3.83 R² 300 – 1500 0.0128 R² 1500 – 100 000 19.2 R²f where f is the frequency (MHz) R is the separation distance (at least λ/2π) Prediction: worst case (mW)(dBm) LPR 770000.60.00093768.0028.8200EXEMPTED LPR 810000.60.00093768.0028.8200EXEMPTED Treshhold ERP VerdictTechnology R min (mm) Transmitter frequency (MHz) Max. decl. ERP (mW) Minimal Safety Distance (mm) This prediction demonstrates the following: The power density levels for FCC that are larger than the minimum safety-distances stated above, are below the maximum levels allowed by regulations.

Test Report

BNetzA - CAB - 02/21 - 102 TEST REPORT Test report no.: 1-3759/21-01-08-A Testing laboratory Applicant CTC advanced GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: http://www.ctcadvanced.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2005) by the Deutsche Akkreditierungsstelle GmbH (DAkkS) The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate starting with the registration number: D-PL-12076-01. Rosemount Tank Radar AB Layoutvägen 1 P O Box 150 435 33 Mölnlycke / SWEDEN Phone: +46 31 3370 0000 Contact: Andrei Stefanescu e-mail: [email protected] Phone: +46 313 370 343 Manufacturer Rosemount Tank Radar AB P O Box 150 Layoutvägen 1 435 33 Mölnlycke / SWEDEN Test standard/s 47 CFR Part 15 Title 47 of the Code of Federal Regulations; Chapter I; Part 15 – Radio frequency devices RSS-211 Level Probing Radar Equipment For further applied tes…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Dajana Prastalo(E&D, Approvals)
[email protected]+46 31 3370000Fax: +46 31 25 30 22

Test Firm

cetecom advanced GmbHGerald Schmidt
[email protected]49-681-598-0Fax: 49-681-598-8775

Technical Specifications

#Rule PartsFrequency RangePower Output
115.25677.00 GHz - 81.00 GHz151.00 mW
Confidentiality
Long Term
Grant Notes
The power listed is peak EIRP calculated in 50MHz bandwidth. This device must be professionally installed. This device must be installed and maintained to ensure a vertically downward orientation of the transmit antenna's main beam. This device may only operate at fixed locations and may not operate while being moved, or while inside a moving container. Hand-held applications are prohibited. The device and its antenna(s) must be installed to provide a separation distance of at least 20 cm from all persons.

Other Applications from Rosemount Tank Radar AB

Level and Flow Transmitter - FCC ID K8C1208CLB - Rosemount Tank Radar AB
K8C1208CLB

Level and Flow Transmitter

May 09, 2023

Equipment Class

LPR - Level Probing Radar
Rosemount 1208A Level transmitter - FCC ID K8C1208LB - Rosemount Tank Radar AB
K8C1208LB

Rosemount 1208A Level transmitter

Dec 15, 2022

Equipment Class

DTS - Digital Transmission System
Rosemount 3408 Level Transmitter - FCC ID K8C3408T - Rosemount Tank Radar AB
K8C3408T

Rosemount 3408 Level Transmitter

Oct 20, 2022

Equipment Class

LPR - Level Probing Radar
Rosemount 3408 Level Transmitter - FCC ID K8C3408TB - Rosemount Tank Radar AB
K8C3408TB

Rosemount 3408 Level Transmitter

Oct 20, 2022

Equipment Class

LPR - Level Probing Radar
Rosemount 3408 Level Transmitter - FCC ID K8C3408LB - Rosemount Tank Radar AB
K8C3408LB

Rosemount 3408 Level Transmitter

Oct 20, 2022

Equipment Class

DTS - Digital Transmission System