FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. FreeWave Technologies Inc./
  3. KNYPRW5000AA

KNYPRW5000AAWireless 802.11ac/b/g/n access point

FreeWave Technologies Inc.
Wireless 802.11ac/b/g/n access point - FCC ID KNYPRW5000AA - FreeWave Technologies Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Oct 22, 2015
Application Purpose
Original Equipment
Date of Application
Oct 14, 2015
Equipment Note
Wireless 802.11ac/b/g/n access point
Frequency Range
2412.00000000 - 2462.00000000
Company
FreeWave Technologies Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗
↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

PartNumber:LUM0073AA Revision:Aug-2015 WP201 Access Point User Manual Safety Information The products described in this manual can fail in a variety of modes due to misuse, age, or malfunction. Systems with these products must be designed to prevent personal injury and property damage during product operation and in the event of product failure. Warning! Do notremoveorinsert theEthernet ordiagnostics cablewhilecircuit is liveunless theareais knowntobefreeof ignitionconcentrations of flammablegasses orvapors. Warranty FreeWave Technologies, Inc. warrants your FreeWave® Wireless Data Radio against defects in materials and manufacturing for a period of one year from the date of shipment, depending on model number. In the event of a Product failure due to materials or workmanship, FreeWave will, at its discretion, repair or replace the Product. For evaultation of Warranty coverage, return the Product to FreeWave upon receiving a Return Material Authorization (RMA). In no event will FreeWave Technologies, Inc., its suppliers, or its licensors be liable for any damages arising from the use of or inability to use this Product. This includes business interruption, loss of business information, or other loss which may arise from the use of this Product. OEM customer’s warranty periods can vary. Warranty Policy willnot applyin the following circumstances: 1. If Product repair, adjustments, or parts replacements are required due to accident, neglect, or undue physical, electrical, or electromagnetic stress. 2. If Product is used outside of FreeWave specifications as stated in the Product's data sheet. 3. If Product has been modified, repaired, or altered by Customer unless FreeWave specifically authorized such alterations in each instance in writing. This includes the addition of conformal coating. Special Rate Replacement Option A special rate replacement option is offered to non-warranty returns or upgrades. The option to purchase the replacement unit at this special rate is only valid for that RMA. The special replacement rate option expires if not exercised within 30 days of final disposition of RMA. FreeWave Technologies, Inc. 5395 Pearl Parkway, Suite 100 Boulder, CO 80301 303.381.9200 Toll Free: 1.866.923.6168 Fax: 303.786.9948 Copyright © 2015 by FreeWave Technologies, Inc. All rights reserved. www.freewave.com Page 2 of 38LUM0073AA Rev Aug-2015 This document is the property of FreeWave Technologies, Inc. and contains proprietary information owned by FreeWave®. This document cannot be reproduced in whole or in part by any means without written permission from FreeWave Technologies, Inc. WP201AccessPoint:UserManual WP201® Return Material Authorization (RMA) Policy and Procedures This policy describes the responsibilities and procedures of the Customer and FreeWave when aWP201® device return is required. When a request for aWP201® device replacement has been validated by FreeWave’s Customer Support, FreeWave’s policy for processing the device returned due to a fault is to replace the device with a new or refurbished device upon receipt of the reported faulty product. Important!: This policy means that a failure analysis on the returned device will NOT be performed and reported to customers. Note: This RMA policy is subject to change without notice. Detailed information about the FreeWave RMA policy can be found atwww.freewave.com. FreeWave Responsibilities A failedWP201® product is inventoried at FreeWave. If FreeWave experiences a high degree of failures or a trend, FreeWave will perform a root-cause analysis and take appropriate corrective action(s). In-Warranty Replacement Procedure 1. Customer contacts FreeWave Customer Support to report the non-functioningWP201® device. 2. FreeWave Customer Support: a. Validates that a device replacement is the appropriate action. b. Issues a FreeWave RMA number. 3. The Customer pays the shipping costs to return theWP201® device to FreeWave. 4. FreeWave sends a new or refurbishedWP201® device to the Customer. Important!: Any visual or external damage noted on returned units may void the warranty. This will be communicated back to the customer and a Purchase Order (PO) will be requested from the customer for product replacement. Out-of-WarrantyWP201Replacement This procedure describes the Customer and FreeWave Customer Support responsibilities for replacing an out- of-warrantyWP201device. Procedure 1. Customer contacts FreeWave Customer Support to report the non-functioningWP201® device. 2. FreeWave Customer Support: a. Validates that the device is out of warranty and if replacement is the appropriate action. b. Requests a PO number from the Customer (to bill the replacementWP201® device and shipping). c. Issues a FreeWave RMA number and advises the Customer to return the device to FreeWave. 3. FreeWave: a. Bills the Customer for the replacementWP201® device and shipping. b. Sends a new or refurbishedWP201® device to the Customer. Export Notification FreeWave Technologies, Inc. products may be subject to control by the Export Administration Regulations (EAR) and/or the International Traffic in Arms Regulations (ITAR). Export, re-export, or transfer of these products without required authorization from the U.S. Department of Commerce, Bureau of Industry and Security, or the U.S. Department of State, Directorate of Defense Trade Controls, as applicable, is prohibited. Any party exporting, re-exporting, or transferring FreeWave products is responsible for LUM0073AA Rev Aug-2015Page 3 of 38 This document is the property of FreeWave Technologies, Inc. and contains proprietary information owned by FreeWave®. This document cannot be reproduced in whole or in part by any means without written permission from FreeWave Technologies, Inc. obtaining all necessary U.S. government authorizations required to ensure compliance with these and other applicable U.S. laws. Consult with your legal counsel for further guidance. FCC Notifications This device complies with Part …

Text truncated - open the document above for the full version.

Users Manual

PartNumber:LUM0073AA Revision:Sep-2015 WP201AccessPoint UserManual SafetyInformation Theproductsdescribedinthismanualcanfailinavarietyofmodesduetomisuse,age,ormalfunction.Systems withtheseproductsmustbedesignedtopreventpersonalinjuryandpropertydamageduringproductoperation andintheeventofproductfailure. Warning!DonotremoveorinserttheEthernetordiagnosticscablewhilecircuitisliveunless theareaisknowntobefreeofignitionconcentrationsofflammablegassesorvapors. Warranty FreeWaveTechnologies,Inc.warrantsyourFreeWave®WirelessDataRadioagainstdefectsinmaterialsand manufacturingforaperiodofoneyearfromthedateofshipment,dependingonmodelnumber.Intheeventofa Productfailureduetomaterialsorworkmanship,FreeWavewill,atitsdiscretion,repairorreplacetheProduct. ForevaluationofWarrantycoverage,returntheProducttoFreeWaveuponreceivingaReturnMaterial Authorization(RMA). InnoeventwillFreeWaveTechnologies,Inc.,itssuppliers,oritslicensorsbeliableforanydamagesarisingfrom theuseoforinabilitytousethisProduct.Thisincludesbusinessinterruption,lossofbusinessinformation,or otherlosswhichmayarisefromtheuseofthisProduct.OEMcustomer’swarrantyperiodscanvary. WarrantyPolicywillnotapplyinthefollowingcircumstances: 1.IfProductrepair,adjustments,orpartsreplacementsarerequiredduetoaccident,neglect,orundue physical,electrical,orelectromagneticstress. 2.IfProductisusedoutsideofFreeWavespecificationsasstatedintheProduct'sdatasheet. 3.IfProducthasbeenmodified,repaired,oralteredbyCustomerunlessFreeWavespecificallyauthorized suchalterationsineachinstanceinwriting.Thisincludestheadditionofconformalcoating. SpecialRateReplacementOption Aspecialratereplacementoptionisofferedtonon-warrantyreturnsorupgrades.Theoptiontopurchasethe replacementunitatthisspecialrateisonlyvalidforthatRMA.Thespecialreplacementrateoptionexpiresifnot exercisedwithin30daysoffinaldispositionofRMA. FreeWaveTechnologies,Inc. 5395PearlParkway,Suite100 Boulder,CO80301 303.381.9200 TollFree:1.866.923.6168 Fax:303.786.9948 Copyright©2015byFreeWaveTechnologies,Inc. Allrightsreserved. www.freewave.com Page2of285LUM0073AARevSep-2015 ThisdocumentisthepropertyofFreeWaveTechnologies,Inc.andcontainsproprietaryinformationownedby FreeWave®.Thisdocumentcannotbereproducedinwholeorinpartbyanymeanswithoutwrittenpermissionfrom FreeWaveTechnologies,Inc. WP201AccessPoint:UserManual WP201®ReturnMaterialAuthorization(RMA)PolicyandProcedures ThispolicydescribestheresponsibilitiesandproceduresoftheCustomerandFreeWavewhenaWP201® devicereturnisrequired. WhenarequestforaWP201®devicereplacementhasbeenvalidatedbyFreeWave’sCustomerSupport, FreeWave’spolicyforprocessingthedevicereturnedduetoafaultistoreplacethedevicewithanewor refurbisheddeviceuponreceiptofthereportedfaultyproduct. Important!:ThispolicymeansthatafailureanalysisonthereturneddevicewillNOTbeperformedand reportedtocustomers. Note:ThisRMApolicyissubjecttochangewithoutnotice. DetailedinformationabouttheFreeWaveRMApolicycanbefoundatwww.freewave.com. FreeWaveResponsibilities AfailedWP201®productisinventoriedatFreeWave.IfFreeWaveexperiencesahighdegreeoffailuresora trend,FreeWavewillperformaroot-causeanalysisandtakeappropriatecorrectiveaction(s). In-WarrantyReplacementProcedure 1.CustomercontactsFreeWaveCustomerSupporttoreportthenon-functioningWP201®device. 2.FreeWaveCustomerSupport: a.Validatesthatadevicereplacementistheappropriateaction. b.IssuesaFreeWaveRMAnumber. 3.TheCustomerpaystheshippingcoststoreturntheWP201®devicetoFreeWave. 4.FreeWavesendsaneworrefurbishedWP201®devicetotheCustomer. Important!:Anyvisualorexternaldamagenotedonreturnedunitsmayvoidthewarranty. ThiswillbecommunicatedbacktothecustomerandaPurchaseOrder(PO)willberequestedfromthe customerforproductreplacement. Out-of-WarrantyWP201Replacement ThisproceduredescribestheCustomerandFreeWaveCustomerSupportresponsibilitiesforreplacinganout- of-warrantyWP201device. Procedure 1.CustomercontactsFreeWaveCustomerSupporttoreportthenon-functioningWP201®device. 2.FreeWaveCustomerSupport: a.Validatesthatthedeviceisoutofwarrantyandifreplacementistheappropriateaction. b.RequestsaPOnumberfromtheCustomer(tobillthereplacementWP201®deviceandshipping). c.IssuesaFreeWaveRMAnumberandadvisestheCustomertoreturnthedevicetoFreeWave. 3.FreeWave: a.BillstheCustomerforthereplacementWP201®deviceandshipping. b.SendsaneworrefurbishedWP201®devicetotheCustomer. LUM0073AARevSep-2015Page3of285 ThisdocumentisthepropertyofFreeWaveTechnologies,Inc.andcontainsproprietaryinformationownedby FreeWave®.Thisdocumentcannotbereproducedinwholeorinpartbyanymeanswithoutwrittenpermissionfrom FreeWaveTechnologies,Inc. ExportNotification FreeWaveTechnologies,Inc.productsmaybesubjecttocontrolbytheExportAdministrationRegulations (EAR)and/ortheInternationalTrafficinArmsRegulations(ITAR).Export,re-export,ortransferofthese productswithoutrequiredauthorizationfromtheU.S.DepartmentofCommerce,BureauofIndustryand Security,ortheU.S.DepartmentofState,DirectorateofDefenseTradeControls,asapplicable,is prohibited.Anypartyexporting,re-exporting,ortransferringFreeWaveproductsisresponsiblefor obtainingallnecessaryU.S.governmentauthorizationsrequiredtoensurecompliancewiththeseandother applicableU.S.laws.Consultwithyourlegalcounselforfurtherguidance. FCCNotifications ThisdevicecomplieswithPart15oftheFCCrules.Operationissubjecttothefollowingtwoconditions:1)This devicemaynotcauseharmfulinterferenceand2)thisdevicemustacceptanyinterferencereceived,including interferencethatmaycauseundesiredoperation. ThecontentofthisguidecoversFreeWaveTechnologies,Inc.modelssoldunderFCCID:KNYPRW5000AA. AllmodelssoldundertheFCCID(s)listedabovemustbeinstalledprofessionally.Anychangesormodifications notexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidtheuser'sauthoritytooperatethis equipment. Thisradiomustnotbeco-locatedoroperatinginconjunctionwithanyotherantennaorradio.Operationsinthe 5.15-5.25GHzbandarerestrictedtoindoorusageonly. FCCNEMAInstallationandLabel Whereapplicable,themodelsdescribedinthisguidemustbeinstalledinaNEMAenclosure.Whenany FreeWaveTechnologies,…

Text truncated - open the document above for the full version.

Attestation Statements

FreeWave Technologies, Inc. 5395 Pearl Pkwy Ste 100, Boulder, CO 80301, U.S.A. PROFESSIONAL INSTALLATION ATTESTATION Date: 2015-10-14 FCC 10: KNYPRW5000AA IC ID: IC: 2329B-PRW5000AA To Whom It May Concern: Please be advised that due to the unique Market and function targeted by this product, this product will need special trained professional in configuring and installing the product. We hereby declare that the product will be distributed through controlled distribution channel which has special trained professional to install this product and will not be sold directly to the general public through retail store. Thank you for your attention. Sincerely yours, Dean Busch Sr. Compliance Engineer TEL: 303 962-7879 FAX: 303 786-9948 E-Mail: [email protected]

Cover Letter(s)

FreeWave Technologies, Inc. 5395 Pearl Pkwy Ste 100, Boulder, CO 80301, U.S.A. Date: 2015-1 0-06 FCC ID: KNYPRW5000AA AUTHORIZATION LETTER To whom it may concern: We, the undersigned, hereby authorize Andrea Hsia I Senior Specialist of Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch (BV CPS Taoyuan) of Taiwan to act on our behalf in all manners relating to FCC application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Andrea Hsia I Senior Specialist of BV CPS Taoyuan on our behalf shall have the same effect as acts of our own. If you have any questions regarding the authorization, please don't hesitate to contact us. Sincerely yours, Dean Busch Sr. Compliance Engineer TEL: 303 962-7879 FAX: 303 786-9948 E-Mail: [email protected]

External Photos

Page 1 CONSTRUCTION PHOTOS OF EUT Page 2 Page 3 Page 4 Page 5 Page 6

ID Label/Location Info

Label location

Internal Photos

Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16

RF Exposure Info

Report No.: SA150716C07E Page No. 1 / 5 Report Format Version: 6.1.1 Reference No.: 150904C09 RF Exposure Report Report No.: SA150716C07E FCC ID: KNYPRW5000AA Test Model: WP201 Received Date: Aug. 27, 2015 Test Date: Sep. 04 ~ Sep. 18, 2015 Issued Date: Oct. 02, 2015 Applicant: FreeWave Technologies, Inc. Address: 5395 Pearl Pkwy Ste 100, Boulder, CO 80301, U.S.A. Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan, R.O.C. Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City 33383, TAIWAN (R.O.C.) This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Report No.: SA150716C07E Page No. 2 / 5 Report Format Version: 6.1.1 Reference No.: 150904C09 Table of Contents Release Control Record .................................................................................................................................. 3 1 Certificate of Conformity ...................................................................................................................... 4 2 RF Exposure .......................................................................................................................................... 5 2.1 Limits for Maximum Permissible Exposure (MPE) .............................................................................. 5 2.2 MPE Calculation Formula ................................................................................................................... 5 2.3 Classification ....................................................................................................................................... 5 3 Calculation Result Of Maximum Conducted Power .......................................................................... 5 Report No.: SA150716C07E Page No. 3 / 5 Report Format Version: 6.1.1 Reference No.: 150904C09 Release Control Record Issue No. Description Date Issued SA150716C07E Original release Oct. 02, 2015 Report No.: SA150716C07E Page No. 4 / 5 Report Format Version: 6.1.1 Reference No.: 150904C09 1 Certificate of Conformity Product: Wireless 802.11ac/b/g/n access point Brand: Freewave Test Model: WP201 Sample Status: Engineering Sample Applicant: FreeWave Technologies, Inc. Test Date: Sep. 04 ~ Sep. 18, 2015 Standards: FCC Part 2 (Section 2.1091) KDB 447498 D03 IEEE C95.1 The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report. Prepared by : , Date:Oct. 02, 2015 Celine Chou / Specialist Approved by : , Date:Oct. 02, 2015 Ken Liu / Senior Manager Report No.: SA150716C07E Page No. 5 / 5 Report Format Version: 6.1.1 Reference No.: 150904C09 2 RF Exposure 2.1 Limits for Maximum Permissible Exposure (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Average Time (minutes) Limits For General Population / Uncontrolled Exposure 300-1500 ... ... F/1500 30 1500-100,000 ... ... 1.0 30 F = Frequency in MHz 2.2 MPE Calculation Formula Pd = (Pout*G) / (4*pi*r 2 ) where Pd = power density in mW/cm 2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm 2.3 Classification The antenna of this product, under normal use condition, is at least 21cm away from the body of the user. So, this device is classified as Mobile Device. 3 Calculation Result Of Maximum Conducted Power Frequency Band (MHz) Max Power (dBm) Antenna Gain (dBi) Distance (cm) Power Density (mW/cm 2 ) Limit (mW/cm 2 ) 2412-2462 24.71 10.18 21 0.556 1 5180-5240 23.13 2.44 21 0.065 1 5745-5825 22.40 10.80 21 0.377 1 Note: 2412 ~ 2462MHz: Directional gain = 5.41dBi + 10log(3) = 10.18dBi 5180 ~ 5240MHz: Directional gain = -2.33dBi + 10log(3) = 2.44dBi 5745 ~ 5825MHz: Directional gain = 6.03dBi + 10log(3) = 10.80dBi CONCULSION: Both of the WLAN 2.4G & WLAN 5G can transmit simultaneously, the formula of calculated the MPE is: CPD1 / LPD1 + CPD2 / LPD2 + ......etc. < 1 CPD = Calculation power density LPD = Limit of power density WLAN 2.4G + WLAN 5.0G = 0.556 + 0.377 = 0.933 Therefore, the maximum calculation of this situation is 0.933, which is less than the “1” limit. ---END---

Test Report

Report No.: RF150716C07E Page No. 1 / 60 Report Format Version: 6.1.1 Reference No.: 150827C23, 150904C09 FCC Test Report Report No.: RF150716C07E FCC ID: KNYPRW5000AA Test Model: WP201 Received Date: Aug. 27, 2015 Test Date: Sep. 04 ~ Sep. 18, 2015 Issued Date: Oct. 02, 2015 Applicant: FreeWave Technologies, Inc. Address: 5395 Pearl Pkwy Ste 100, Boulder, CO 80301, U.S.A. Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan, R.O.C. Lab Address: No.19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City 33383, TAIWAN (R.O.C.) This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Report No.: RF150716C07E Page No. 2 / 60 Report Format Version: 6.1.1 Reference No.: 150827C23, 150904C09 Table of Contents Release Control Record .................................................................................................................................. 4 1 Certificate of Conformity ...................................................................................................................... 5 2 Summary of Test Results ..................................................................................................................... 6 2.1 Measurement Uncertainty ................................................................................................................... 6 2.2 Modification Record ............................................................................................................................ 6 3 General Information .............................................................................................................................. 7 3.1 General Description of EUT ................................................................................................................ 7 3.2 Description of Test Modes ................................................................................................................... 8 3.2.1 Test Mode Applicability and Tested Channel Detail ............................................................................. 9 3.3 Duty Cycle of Test Signal ................................................................................................................... 11 3.4 Description of Support Units ............................................................................................................. 12 3.4.1 Configuration of System under Test .................................................................................................. 12 3.5 General Description of Applied Standards ........................................................................................ 13 4 Test Types and Results ...................................................................................................................... 14 4.1 Radiated Emission and Bandedge Measurement ............................................................................. 14 4.1.1 Limits of Radiated Emission and Bandedge Measurement .............................................................. 14 4.1.2 Test Instruments ................................................................................................................................ 15 4.1.3 Test Procedures ................................................................................................................................. 16 4.1.4 Deviation from Test Standard ............................................................................................................ 16 4.1.5 Test Set Up ........................................................................................................................................ 17 4.1.6 EUT Operating Conditions ................................................................................................................. 17 4.1.7 Test Results ....................................................................................................................................... 18 4.2 Conducted Emission Measurement .................................................................................................. 31 4.2.1 Limits of Conducted Emission Measurement .................................................................................... 31 4.2.2 Test Instruments ................................................................................................................................ 31 4.2.3 Test Procedures ................................................................................................................................. 32 4.2.4 Dev…

Text truncated - open the document above for the full version.

Test Setup Photos

1 PHOTOGRAPHS OF THE TEST CONFIGURATION Conducted Emission Test 2 Radiated Emissions below 1 GHz Test 3 Radiated Emissions above 1 GHz Test

Contact Information

Applicant

Richard Reisbick(VP Engineering)
[email protected]303-981-5017Fax: 303-786-8393

Test Firm

Bureau Veritas CPS (H.K.) Ltd., Taoyuan BranchRichard Chen
[email protected]+886-3-260-0884Fax: +886-3-211-5834

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz296.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is maximum combined conducted. Professional installation required. Device operates with specific antennas in MIMO configurations as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 21 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20 and 40 MHz bandwidth modes.

Other Applications from FreeWave Technologies Inc.

LR455C - FCC ID KNYLRS455C - FreeWave Technologies Inc.
KNYLRS455C

LR455C

Oct 01, 2023

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
FHSS 902 - 928 MHz ISM band radio - FCC ID KNYMM3 - FreeWave Technologies Inc.
KNYMM3

FHSS 902 - 928 MHz ISM band radio

Aug 25, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
435-470 MHz Licensed Band Transceiver, - FCC ID KNYLRS455A - FreeWave Technologies Inc.
KNYLRS455A

435-470 MHz Licensed Band Transceiver,

Aug 04, 2020

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
MM2 - FCC ID KNYAMM0921TT - FreeWave Technologies Inc.
KNYAMM0921TT

MM2

Jan 14, 2014

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
GXM-T14, GXM-T24 - FCC ID KNYAMI0032AT - FreeWave Technologies Inc.
KNYAMI0032AT

GXM-T14, GXM-T24

Dec 12, 2013

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter