Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
27 February, 2001 USERS GUIDE for the SELECTAMP CDMA 800 CHANNELIZED AMPLIFIER MANUAL NO. AE04B-A0279 REVISION -- The information set forth in this document and all rights in and to inventions disclosed herein, and patents which might be granted thereon disclosing, employing or covering the materials, methods, techniques or apparatus described herein are the exclusive property of Andrew Corporation. This document is an operation and maintenance manual. No disclosure or reproduction of the information or drawings shall be made of any other purpose without the prior written consent of Andrew. Use of the information contained herein to fabricate or assemble any item in whole or in part is expressly prohibited. These goods are subject to U.S. Department of State, International Traffic in Arms Regulations, 22 CFR 120-130. This transmitter is intended for use at fixed base station sites only, and is not to be marketed for mobile use. As such, under Section 1.1307 of the FCC Rules, the transmitter is not currently subject to the Commission’s environmental rules pertaining to the routine evaluation for RF exposure prior to equipment authorization. 2601 Telecom Parkway Richardson, Texas 75082-3521 Phone: 972-952-9700 Fax: 972-952-0019 AE04B-A0279 Rev. -- LIST OF EFFECTIVE PAGES Document use is restricted to that described on cover i LIST OF EFFECTIVE PAGES Dates of issue for original and changed pages are: Original...................O.................21 June 2000 TOTAL NUMBER OF PAGES IN THIS PUBLICATION IS __, CONSISTING OF THE FOLLOWING: Page Change No. (O = Original Page) Title Page O List of Effective Pages (i) O Safety Summary (ii) O Table of Contents (iii - iv) O Chapter 1 (1-1 thru 1-5) O Chapter 2 (2-1) O Chapter 3 (3-1 thru 3-3) O Chapter 4 (4-1) O Appendix A (A-1 thru A-5) O Appendix B (B-1 thru B-15) O Appendix C (C-1 thru C-15) O Appendix D (D-1 thru D-2) O AE04B-A0279 Rev. -- SAFETY SUMMARY Document use is restricted to that described on cover ii SAFETY SUMMARY High voltage is used in the operation of this equipment. Death on contact may result if personnel fail to observe the following safety precautions: Do not be misled by the term "Low Voltage." Potentials as low as 50 volts may cause death under adverse conditions. Do not crush, puncture, disassemble, or otherwise mutilate batteries. Leaking batteries can cause serious damage to equipment and injury to personnel. Do not remove covers or access plates on the equipment unless you are authorized to do so. Do not work on electronic equipment unless there is another person nearby who is familiar with the operation of the equipment and is trained in administering first aid. Whenever possible, disconnect the equipment from the power source before beginning maintenance. To prevent electrical shock or damage to the equipment, do not operate it until you thoroughly understand the operation and function of all controls, indicators, and connectors. Turn off all power to the equipment before replacing any fuses. FIRST AID In case of electrical shock: Do not try to pull or grab the individual. If possible, turn off the electrical power. If you cannot turn off the electrical power, pull, push, or lift the person to safety using a dry wooden pole, a dry rope, or some other insulating material. Send for help as soon as possible. After the injured person is no longer in contact with the source of electrical shock, move the person a short distance away and immediately administer first aid and artificial resuscitation as required. AE04B-A0279 Rev. -- TABLE OF CONTENTS Document use is restricted to that described on cover iii TABLE OF CONTENTS CHAPTER 1 DESCRIPTION..............................................................................................................1-1 1.1 OVERVIEW.............................................................................................................................1-1 1.2 ELECTRICAL SPECIFICATIONS.............................................................................................1-1 1.3 MECHANICAL SPECIFICATIONS............................................................................................1-2 1.4 ENVIRONMENTAL SPECIFICATIONS....................................................................................1-2 1.5 TECHNICAL ASSISTANCE ....................................................................................................1-2 CHAPTER 2 OPERATIONAL OVERVIEW.........................................................................................2-1 2.1 OVERVIEW.............................................................................................................................2-1 2.2 RF DISTRIBUTION..................................................................................................................2-1 2.3 POWER DISTRIBUTION.........................................................................................................2-1 2.4 CONTROL DISTRIBUTION......................................................................................................2-1 CHAPTER 3 FUNCTIONAL DESCRIPTION.......................................................................................3-1 3.1 OVERVIEW.............................................................................................................................3-1 3.2 FUNCTIONAL DESCRIPTION.................................................................................................3-1 3.2.1 Diplexer........................................................................................................................3-1 3.2.2 LNA/Attenuator............................................................................................................3-1 3.2.3 Channelizer..................................................................................................................3-1 3.2.3.1 Downconverter........................................................................…
Text truncated - open the document above for the full version.
FCC ID: KUWSELA-800CHZ Request for Confidentiality In accordance with 47 C.F.R. Section 0.459, we, Andrew Corporation, hereby request confidentiality for the block diagram, schematic and product description presented for certification. In support of the Request for Confidentiality, the following is stated: Enclosed within this application is technical information, which we (Andrew Corporation) deem to be trade secrets and proprietary to this product. If made public, the information could and might be used to our disadvantage. To assist in assuring that we (Andrew Corporation) receive the full value of our product and protect its competitive posture, we respectfully request this grant of confidentiality. _________________ Marvin D. Black Andrew Corporation Program Manager
2.1033 (c )(9) TUNE-UP PROCEDURE There are no tune-up procedures for the SelectAmp CDMA 800 Channalized Amplifer.
2601 Telecom Parkway · Richardson, Texas · United States
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 2 | 22 | 824 MHz - 849 MHz | 8 W | G9W | Amp |

EOCell Transceiver System
Equipment Class
DTS - Digital Transmission System
Downlink Booster
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Bi-Directional Amplifier
Equipment Class
AMP - Amplifier
Repeater
Equipment Class
AMP - Amplifier
Repeater
Equipment Class
AMP - Amplifier