Rhein Tech Laboratories, Inc. Client: Hunter Engineering Company 360 Herndon Parkway Model: 45-1443 Suite 1400 Standards: FCC 15.247/IC RSS-210 Herndon, VA 20170 ID’s: LS3-45-1443/2938A-451443 http://www.rheintech.com Report #: 2013040 Page 42 of 53 Appendix M: Manual Please refer to the following pages. ©2013 Copyright Hunter Engineering Company Form 3850-T, 02-13 Supersedes Form 3850-T, 03-11 WinAlign ® Alignment Software Operation Manual Ve r s i o n 14 .1 CONTENTS 3 Contents 1. Getting Started ..............................................................15 1.1 General Introduction...................................................................15 References.......................................................................15 1.2 System Requirements .................................................................16 1.3 For Your Safety - Hazard Definitions ......................................................16 IMPORTANT SAFETY INSTRUCTIONS................................................16 Precautions for Systems Equipped with HFSS, XF and XF2 Cordless Sensors ..................17 Specific Precautions/Power Source....................................................18 North America..............................................................18 Other Regions..............................................................18 FUSING: ..................................................................18 EQUIPMENT SERVICE:......................................................18 PROVISIONS FOR LIFTING AND CARRYING:....................................18 Equipment Specifications............................................................18 Atmospherics...............................................................18 Explanation of Symbols .............................................................18 1.4 What’s New in WinAlign® 14.1...........................................................19 Support for 64-bit Windows ..........................................................19 Begin Alignment or QuickCheck from Logo Screen........................................19 Support for New Accessories While Performing QuickCheck................................19 Alignment Job Counter..............................................................19 1.5 Operating the Console.................................................................19 Turning Console Power On ..........................................................19 Turning Console Power Off ..........................................................19 Using the Softkeys .................................................................19 Alignment Procedure Bar............................................................21 Using the VirtualView® Adjustment Feature .............................................21 VirtualView® Angle Selector .........................................................22 SoundGuide® Tone Feedback System .................................................24 AlignGuide® Training Feature ........................................................24 Resetting the Program..............................................................25 Just-In-Time Training Video Instructions ................................................25 Video Library (WA200 Only) .........................................................25 Using the Screen Saver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 1.6 Using the Remote Control ..............................................................26 Sensor Compensation Display Using the Remote Control (Camera Sensors Only) ...............27 Measure Caster Display Using the Remote Control........................................27 Alignment Values Display Using the Remote Control ......................................27 Selection of Alignment Values to Display Using the Remote Control ..........................27 Identification of Values Displayed and Bar Graphs Using the Remote Control...................29 Examples of Alignment Displays Using the Remote Control.................................30 Recording Measurements Using the Remote Control (Plus Model Only) .......................31 Display of Measurements Using the Remote Control - Value Displays . . . . . . . . . . . . . . . . . . . . . . . . . 32 Remote Control Indicators ...........................................................33 Storing Measurement Values Using the Remote Control....................................33 Tire Temperature Readings Using the Remote Control.....................................34 Tire Pressure Readings Using the Remote Control........................................35 Tire Tread Depth Using the Remote Control .............................................35 Measuring Frame Angle Using the Remote Control........................................36 Reviewing and Editing Stored Values Using the Remote Control .............................36 Remote Control Summary / Transmit Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Ride Height Using the Remote Control .................................................37 Using the Standard Remote Control ...................................................37 1.7 Example Alignment Jobs ...............................................................38 Example Alignment with AutoVIN™ and ExpressAlign® with Camera Based Sensors ............38 Example Alignment with AutoVIN™ and ExpressAlign® Adjustment with Conventional Sensors ....38 4 CONTENTS 2. Basic Operation Information ....................................................41 2.1 Sensors and Targets...................................................................41 TD Target™ Alignment Reflectors and Quickgrip™ Adaptors ................................41 TD Target™ Alignment Reflectors...............................................41 Vehicle Corner..............................................................…
Text truncated - open the document above for the full version.
Rhein Tech Laboratories, Inc. Client: Hunter Engineering Company 360 Herndon Parkway Model: 45-1443 Suite 1400 Standards: FCC 15.247/IC RSS-210 Herndon, VA 20170 ID’s: LS3-45-1443/2938A-451443 http://www.rheintech.com Report #: 2013040 Page 31 of 53 Appendix C: FCC Confidentiality Request Letter Please refer to the following page.
Rhein Tech Laboratories, Inc. Client: Hunter Engineering Company 360 Herndon Parkway Model: 45-1443 Suite 1400 Standards: FCC 15.247/IC RSS-210 Herndon, VA 20170 ID’s: LS3-45-1443/2938A-451443 http://www.rheintech.com Report #: 2013040 Page 47 of 53 Appendix O: External Photographs Photograph 8: PCB Front with Shield Rhein Tech Laboratories, Inc. Client: Hunter Engineering Company 360 Herndon Parkway Model: 45-1443 Suite 1400 Standards: FCC 15.247/IC RSS-210 Herndon, VA 20170 ID’s: LS3-45-1443/2938A-451443 http://www.rheintech.com Report #: 2013040 Page 48 of 53 Photograph 9: PCB Front without Shield Rhein Tech Laboratories, Inc. Client: Hunter Engineering Company 360 Herndon Parkway Model: 45-1443 Suite 1400 Standards: FCC 15.247/IC RSS-210 Herndon, VA 20170 ID’s: LS3-45-1443/2938A-451443 http://www.rheintech.com Report #: 2013040 Page 49 of 53 Photograph 10: PCB Back Rhein Tech Laboratories, Inc. Client: Hunter Engineering Company 360 Herndon Parkway Model: 45-1443 Suite 1400 Standards: FCC 15.247/IC RSS-210 Herndon, VA 20170 ID’s: LS3-45-1443/2938A-451443 http://www.rheintech.com Report #: 2013040 Page 50 of 53 Photograph 11: Sample Host
Rhein Tech Laboratories, Inc. Client: Hunter Engineering Company 360 Herndon Parkway Model: 45-1443 Suite 1400 Standards: FCC 15.247/IC RSS-210 Herndon, VA 20170 ID’s: LS3-45-1443/2938A-451443 http://www.rheintech.com Report #: 2013040 Page 37 of 53 Appendix I: Label and Label Location Photograph 1: ID Label & Location Rhein Tech Laboratories, Inc. Client: Hunter Engineering Company 360 Herndon Parkway Model: 45-1443 Suite 1400 Standards: FCC 15.247/IC RSS-210 Herndon, VA 20170 ID’s: LS3-45-1443/2938A-451443 http://www.rheintech.com Report #: 2013040 Page 38 of 53 Photograph 2: “Contains FCC ID:.....” Label Sample Photograph 3: “Contains FCC ID:....” Label Location on Back of Sample Host
Rhein Tech Laboratories, Inc. Client: Hunter Engineering Company 360 Herndon Parkway Model: 45-1443 Suite 1400 Standards: FCC 15.247/IC RSS-210 Herndon, VA 20170 ID’s: LS3-45-1443/2938A-451443 http://www.rheintech.com Report #: 2013040 Page 51 of 53 Appendix P: Internal Photographs Photograph 12: PCB Front with Shield Rhein Tech Laboratories, Inc. Client: Hunter Engineering Company 360 Herndon Parkway Model: 45-1443 Suite 1400 Standards: FCC 15.247/IC RSS-210 Herndon, VA 20170 ID’s: LS3-45-1443/2938A-451443 http://www.rheintech.com Report #: 2013040 Page 52 of 53 Photograph 13: PCB Front without Shield Rhein Tech Laboratories, Inc. Client: Hunter Engineering Company 360 Herndon Parkway Model: 45-1443 Suite 1400 Standards: FCC 15.247/IC RSS-210 Herndon, VA 20170 ID’s: LS3-45-1443/2938A-451443 http://www.rheintech.com Report #: 2013040 Page 53 of 53 Photograph 14: PCB Back
Rhein Tech Laboratories, Inc. Client: Hunter Engineering Company 360 Herndon Parkway Model: 45-1443 Suite 1400 Standards: FCC 15.247/IC RSS-210 Herndon, VA 20170 ID’s: LS3-45-1443/2938A-451443 http://www.rheintech.com Report #: 2013040 Page 29 of 53 Appendix A: FCC Part 1.1307, 1.1310, 2.1091, 2.1093; IC RSS-Gen: RF Exposure No RF Exposure Evaluation Required if power is below the following threshold: Tunable Range f(GHz) Low f(GHz) High Center of Tunable Band (GHz) 60/f SAR Limitation (mW) 2.405 2.480 2.443 24.6 Maximum measured transmitter power: Pout Conducted (mW) Maximum Antenna Gain (numeric) Pout EIRP (mW) 2.0 2.1 4.2 Threshold at which no RF exposure evaluation is 24.6 mW. Maximum TX Power is 2.1 mW conducted and 4.4mW EIRP. Conclusion: No RF exposure evaluation is required since the maximum Transmitter Pout (both conducted and EIRP) is below the FCC threshold.
Engineering Solutions & Electromagnetic Compatibility Services 360 Herndon Pkwy | Suite 1400 | Herndon | Virginia 20170 Phone: 703.689.0368 | Fax: 703.689.2056 | www.rheintech.com Certification Application Report for Full Modular Approval FCC Part 15.247 & Industry Canada RSS-210 Test Lab: Rhein Tech Laboratories, Inc. Tel: 703-689-0368 360 Herndon Parkway Fax: 703-689-2056 Suite 1400 www.rheintech.com Herndon, VA 20170 E-Mail: [email protected] Applicant: Hunter Engineering Co. Tel: 314-731-3020 11250 Hunter Drive Fax: 314-731-9932 Bridgeton, MO 63044-2391 Contact: Jim McClenahan FCC ID/ IC LS3-45-1443 2938A-451443 Test Report Date April 12, 2013 Platform N/A RTL Work Order # 2013040 Model 45-1443 RTL Quote # QRTL13-040A American National Standard Institute ANSI C63.4-2003: Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz FCC Classification DTS – Part 15 Digital Transmission System FCC Rule Part(s)/Guidance FCC Rules Part 15.247: Operation within the bands 920-928 MHz, 2400- 2483.5 MHz and 5725-5850 MHz Direct Sequence System 2012 Industry Canada RSS-210 Issue 8: Low Power License-Exempt Communications Devices Industry Canada RSS-Gen Issue 5: General Requirements and Information for the Certification of Radio Apparatus Digital Interface Information Digital Interface was found to be compliant Frequency Range (MHz) Output Power (W)* Frequency Tolerance Emission Designator 2405 – 2480 0.002 N/A 1M50FXD * power is peak conducted I, the undersigned, hereby declare that the equipment tested and referenced in this report conforms to the identified standard(s) as described in this test report. No modifications were made to the equipment during testing in order to achieve compliance with these standards. Furthermore, there was no deviation from, additions to, or exclusions from, the applicable parts of FCC Part 2, FCC Part 15, Industry Canada RSS-210, RSS-Gen, and ANSI C63.4. Signature: Date: April 12, 2013 Typed/Printed Name: Desmond A. Fraser Position: President This report may not be reproduced, except in full, without the written approval of Rhein Tech Laboratories, Inc. and Hunter Engineering Company. The test results relate only to the item(s) tested. These tests are accredited and meet the requirements of ISO/IEC 17025 as verified by ANSI-ASQ National Accreditation Board/ACLASS. Refer to certificate and scope of accreditation AT-1445. Rhein Tech Laboratories, Inc. Client: Hunter Engineering Company 360 Herndon Parkway Model: 45-1443 Suite 1400 Standards: FCC 15.247/IC RSS-210 Herndon, VA 20170 ID’s: LS3-45-1443/2938A-451443 http://www.rheintech.com Report #: 2013040 Page 2 of 53 Table of Contents 1 General Information ............................................................................................................................... 5 1.1 Scope ............................................................................................................................................ 5 1.2 Description of EUT ........................................................................................................................ 5 1.3 Test Facility ................................................................................................................................... 5 1.4 Related Submittal(s)/Grant(s) ....................................................................................................... 5 1.5 Modifications ................................................................................................................................. 5 2 Test Information ..................................................................................................................................... 6 2.1 Description of Test Modes ............................................................................................................ 6 2.2 Exercising the EUT ....................................................................................................................... 6 2.3 Test Result Summary .................................................................................................................... 6 2.4 Test System Details ...................................................................................................................... 7 2.5 Configuration of Tested System .................................................................................................... 7 3 Peak Output Power - 15.247(b)(3); RSS-Gen ....................................................................................... 8 3.1 Power Output Test Procedure ....................................................................................................... 8 3.2 Power Output Test Data ................................................................................................................ 8 4 Compliance with the Band Edge – FCC 15.247(d); RSS-Gen .............................................................. 9 4.1 Band Edge Test Procedure ........................................................................................................... 9 4.2 Band Edge Test Results ............................................................................................................. 10 4.2.1 Calculation of Lower Band Edge ............................................................................................. 10 4.2.2 Lower Band Edge – Conducted Delta Plot ............................................................................. 10 4.2.3 Calculation of Upper Band Edge ............................................................................................. 11 4.2.4 Upper Band Edge – Conducted Delta Plot ............................................................................. 11 5 Antenna Conducted Spurious Emissions - 15.247(d); RSS-Gen ........................................................ 13 5.1 Antenna Conducted Spurious Emissions Test Procedu…
Text truncated - open the document above for the full version.
Rhein Tech Laboratories, Inc. Client: Hunter Engineering Company 360 Herndon Parkway Model: 45-1443 Suite 1400 Standards: FCC 15.247/IC RSS-210 Herndon, VA 20170 ID’s: LS3-45-1443/2938A-451443 http://www.rheintech.com Report #: 2013040 Page 43 of 53 Appendix N: Test Photographs Photograph 4: Radiated Emissions Testing – Front View Rhein Tech Laboratories, Inc. Client: Hunter Engineering Company 360 Herndon Parkway Model: 45-1443 Suite 1400 Standards: FCC 15.247/IC RSS-210 Herndon, VA 20170 ID’s: LS3-45-1443/2938A-451443 http://www.rheintech.com Report #: 2013040 Page 44 of 53 Photograph 5: Radiated Emissions Testing – Back View Rhein Tech Laboratories, Inc. Client: Hunter Engineering Company 360 Herndon Parkway Model: 45-1443 Suite 1400 Standards: FCC 15.247/IC RSS-210 Herndon, VA 20170 ID’s: LS3-45-1443/2938A-451443 http://www.rheintech.com Report #: 2013040 Page 45 of 53 Photograph 6: AC Conducted Emissions Testing – Front View Rhein Tech Laboratories, Inc. Client: Hunter Engineering Company 360 Herndon Parkway Model: 45-1443 Suite 1400 Standards: FCC 15.247/IC RSS-210 Herndon, VA 20170 ID’s: LS3-45-1443/2938A-451443 http://www.rheintech.com Report #: 2013040 Page 46 of 53 Photograph 7: AC Conducted Emissions Testing – Back View
360 Herndon Parkway · Herndon, Virginia · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 2.00 mW |

Hunter Model 146-59-1, Alignment Console RF Remote Control
Equipment Class
DTS - Digital Transmission System
XF3 2.4 GHz Radio Module
Equipment Class
DTS - Digital Transmission System
XF-II Wireless
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx VerifiedDXX - Part 15 Low Power Communication Device Transmitter
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter