LYHELN1V1Industrial WLAN Access Point

Siemens AG
Industrial WLAN Access Point - FCC ID LYHELN1V1 - Siemens AG
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Mar 31, 2014
Application Purpose
Original Equipment
Date of Application
Mar 24, 2014
Equipment Note
Industrial WLAN Access Point
Frequency Range
5180.00000000 - 5240.00000000
Company
Siemens AG
Country
Germany

Documents & Files

Select a file to view

Users Manual

โ†—

Attestation Statements

โ†—
โ†—
โ†—
โ†—

Cover Letter(s)

โ†—
โ†—

External Photos

โ†—

ID Label/Location Info

โ†—

Internal Photos

โ†—

RF Exposure Info

โ†—

Test Report

โ†—

Test Setup Photos

โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

SCALANCE W760/W720 ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ SIMATIC NET Industrial Wireless LAN SCALANCE W760/W720 Operating Instructions 07/2013 C79000-G89xx-C322-01 Information on the Internet 1 Introduction 2 Description 3 Mounting 4 Connection 5 Technical data 6 Approvals 7 Siemens AG Industry Sector Postfach 48 48 90026 NรœRNBERG GERMANY Order number: C79000-G89xx-C322-01 โ“… 07/2013 Technical data subject to change Copyright ยฉ Siemens AG 2013. All rights reserved Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance a re required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. Trademarks All names identified by ยฎ are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. SCALANCE W760/W720 Operating Instructions, 07/2013, C79000-G89xx-C322-01 3 Contents 1 Information on the Internet ...................................................................................................................... 5 2 Introduction ............................................................................................................................................. 7 2.1 Information on the Operating Instructions ...................................................................................... 7 2.2 Structure of the type designation ................................................................................................... 8 2.3 Security information ....................................................................................................................... 8 3 Description .............................................................................................................................................. 9 3.1 Components of the product ............................................................................................................ 9 3.2 LED display .................................................................................................................................... 9 3.3 Reset button ................................................................................................................................. 11 4 Mounting ............................................................................................................................................... 13 4.1 Access restriction due to high housing temperature .................................................................... 13 4.2 Installing on a DIN rail / removing ................................................................................................ 14 5 Connection ........................................................................................................................................... 17 5.1 Lightning protection, power supply and grounding ...................................................................... 17 5.2 Power supply ................................................................................................................................ 21 5.3 Ethernet ........................................................................................................................................ 22 5.4 Suitable cables for power supply and Ethernet ........................................................................... 23 5.5 Antenna connectors ..................................................................................................................... 24 5.6 Suitable antenna cables and antennas ...........................................โ€ฆ

Text truncated - open the document above for the full version.

Attestation Statements

American Certification Body Inc. 6731 Whittier Ave, Suite C110 McLean, VA22101 Date: 27.03.2014 FCC ID: LYHELN1V1 IC: 267AA-ELN1V1 Model Number: ELN-W1-RJ-E1 Frequency Band Capability Frequency Band MHz Modulation Method 2412-2462 802.11b 2412-2462 802.11g 2412-2462 802.11n, HT20 2422 802.11n, HT40 5180-5240 802.11a 5180-5240 802.11n, HT20 5190-5230 802.11n, HT40 5745-5825 802.11a 5745-5825 802.11n, HT20 5755-5795 802.11n, HT40 Strasskirchen, 27.03.2014 Thomas Ring Manager Certification CSA Group Bayern GmbH Ohmstr. 1-4 94342 Strasskirchen Germany

Cover Letter(s)

Request for Confidentiality Date: 20.02.2014 Subject: Confidentiality Request for: FCC ID: LYHELN1V1 IC: 267AA-ELN1V1 Pursuant to FCC 47 CRF 0.457(d) and 0.459 and IC RSP-100, Section 10, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term External Photos Short Term Permanent* 1 Internal Photos Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Parts List & Placement/BOM Short Term Permanent Tune-Up Procedure Short Term Permanent Schematics Short Term Test Setup Photos Short Term Permanent* Userโ€™s Manual *Note: ______(Insert Explanation as Necessary)______ Siemens AG has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of (0) days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify ACB in the event information regarding the product or the product is made available to the public. ACB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. NOTE for Industry Canada Applications: The applicant understands that until such time that IC distinguishes between Short Term and Permanent Confidentiality, either type of marked exhibit above will simply be marked Confidential when submitted to IC. Sincerely, By: Manager Certification Thomas Ring Title Name 1 - The asterisked items (*) require further justification before permanent confidentiality will be allowed. These also currently require review by the FCC under their Permit-But-Ask policy before the grant is issued and can delay completion of an application. Further justification should be added to the note above. One such example for a potted device would be: โ€œThe EUT is FULLY potted using a non-removable epoxy based material. Removal of potting material causes irreparable damage to internal circuitry. See photographs exhibits that outline the device before and after potting.โ€

External Photos

mikes-testingpartners gmbh File No. T36325-00, page 1 of 7 Ohmstrasse 2-4 ๏‚ž 94342 STRASSKIRCHEN ๏‚ž GERMANY Tel.: +49(0)9424-94810 ๏‚ž Fax: +49(0)9424-9481240 Rev. No. 1.2, 2013-04-04 EMI โˆ’ T E S T R E P O R T Attachment A to Test Report No. : T36325-00 19. February 2014 ______________________________________________________________________________________________ Date of issue Type / Model Name : SCALANCE W700 / ELN Product Description : Industrial WLAN access point Applicant : Siemens AG, Industrial Automation Division Address : Gleiwitzer Strasse 555 90475 NUERNBERG, GERMANY Manufacturer : Siemens AG, Automation & Drives Address : Oestliche Rheinbrueckenstrasse 50 76187 KARLSRUHE, GERMANY Licence holder : Siemens AG, Automation & Drives Address : Oestliche Rheinbrueckenstrasse 50 76187 KARLSRUHE, GERMANY The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permission of the test laboratory. mikes-testingpartners gmbh File No. T36325-00, page 2 of 7 Ohmstrasse 2-4 ๏‚ž 94342 STRASSKIRCHEN ๏‚ž GERMANY Tel.: +49(0)9424-94810 ๏‚ž Fax: +49(0)9424-9481240 Rev. No. 1.2, 2013-04-04 Contents 1 P h o t o d o c u m e n t a t i o n o f t h e E U T 3 1.1 External views: 3 1.2 Internal views 6 mikes-testingpartners gmbh File No. T36325-00, page 3 of 7 Ohmstrasse 2-4 ๏‚ž 94342 STRASSKIRCHEN ๏‚ž GERMANY Tel.: +49(0)9424-94810 ๏‚ž Fax: +49(0)9424-9481240 Rev. No. 1.2, 2013-04-04 1 P h o t o d o c u m e n t a t i o n o f t h e E U T 1.1 External views: Front view Rear view mikes-testingpartners gmbh File No. T36325-00, page 4 of 7 Ohmstrasse 2-4 ๏‚ž 94342 STRASSKIRCHEN ๏‚ž GERMANY Tel.: +49(0)9424-94810 ๏‚ž Fax: +49(0)9424-9481240 Rev. No. 1.2, 2013-04-04 mikes-testingpartners gmbh File No. T36325-00, page 5 of 7 Ohmstrasse 2-4 ๏‚ž 94342 STRASSKIRCHEN ๏‚ž GERMANY Tel.: +49(0)9424-94810 ๏‚ž Fax: +49(0)9424-9481240 Rev. No. 1.2, 2013-04-04

Internal Photos

mikes-testingpartners gmbh File No. T36325-00, page 1 of 7 Ohmstrasse 2-4 ๏‚ž 94342 STRASSKIRCHEN ๏‚ž GERMANY Tel.: +49(0)9424-94810 ๏‚ž Fax: +49(0)9424-9481240 Rev. No. 1.2, 2013-04-04 EMI โˆ’ T E S T R E P O R T Attachment A to Test Report No. : T36325-00 19. February 2014 ______________________________________________________________________________________________ Date of issue Type / Model Name : SCALANCE W700 / ELN Product Description : Industrial WLAN access point Applicant : Siemens AG, Industrial Automation Division Address : Gleiwitzer Strasse 555 90475 NUERNBERG, GERMANY Manufacturer : Siemens AG, Automation & Drives Address : Oestliche Rheinbrueckenstrasse 50 76187 KARLSRUHE, GERMANY Licence holder : Siemens AG, Automation & Drives Address : Oestliche Rheinbrueckenstrasse 50 76187 KARLSRUHE, GERMANY The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permission of the test laboratory. mikes-testingpartners gmbh File No. T36325-00, page 2 of 7 Ohmstrasse 2-4 ๏‚ž 94342 STRASSKIRCHEN ๏‚ž GERMANY Tel.: +49(0)9424-94810 ๏‚ž Fax: +49(0)9424-9481240 Rev. No. 1.2, 2013-04-04 Contents 1 P h o t o d o c u m e n t a t i o n o f t h e E U T 3 1.1 External views: 3 1.2 Internal views 6 mikes-testingpartners gmbh File No. T36325-00, page 6 of 7 Ohmstrasse 2-4 ๏‚ž 94342 STRASSKIRCHEN ๏‚ž GERMANY Tel.: +49(0)9424-94810 ๏‚ž Fax: +49(0)9424-9481240 Rev. No. 1.2, 2013-04-04 1.2 Internal views mikes-testingpartners gmbh File No. T36325-00, page 7 of 7 Ohmstrasse 2-4 ๏‚ž 94342 STRASSKIRCHEN ๏‚ž GERMANY Tel.: +49(0)9424-94810 ๏‚ž Fax: +49(0)9424-9481240 Rev. No. 1.2, 2013-04-04

RF Exposure Info

FCC ID: LYHELN1V1 IC: 267AA-ELN1V1 CSA Group Bayern GmbH File No. T36325-00-04HS, page 1 of 69 Ohmstrasse 1-4 ๏‚ž 94342 STRASSKIRCHEN ๏‚ž GERMANY Tel.:+49(0)9424-94810 ๏‚ž Fax:+49(0)9424-9481440 Rev. No. 3.0, 2014-01-31 EMI โˆ’ T E S T R E P O R T - FCC Part 15.407 and RSS210 - Test Report No. : T36325-00-04HS 25 March 2014 ______________________________________________________________________________________________ Date of issue Type / Model Name : SCALANCE W700 / ELN Product Description : Industrial WLAN access point Applicant : Siemens AG, Industrial Automation Division Address : Gleiwitzer Strasse 555 90475 NUERNBERG, GERMANY Manufacturer : Siemens AG, Automation & Drives Address : Oestliche Rheinbrueckenstrasse 50 76187 KARLSRUHE, GERMANY Licence holder : Siemens AG, Automation & Drives Address : Oestliche Rheinbrueckenstrasse 50 76187 KARLSRUHE, GERMANY Test Result according to the standards listed in clause 1 test standards: POSITIVE The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permission of the test laboratory. FCC ID: LYHELN1V1 IC: 267AA-ELN1V1 CSA Group Bayern GmbH File No. T36325-00-04HS, page 2 of 69 Ohmstrasse 1-4 ๏‚ž 94342 STRASSKIRCHEN ๏‚ž GERMANY Tel.:+49(0)9424-94810 ๏‚ž Fax:+49(0)9424-9481440 Rev. No. 3.0, 2014-01-31 Contents 1 T E S T S T A N D A R D S 3 2 S U M M A R Y 4 2.1 Test result summary 4 2.2 General remarks 5 2.3 Final assessment 7 3 E Q U I P M E N T U N D E R T E S T 8 3.1 Photo documentation of the EUT โ€“ Detailed photos see attachment A 8 3.2 Power supply system utilised 8 3.3 Short description of the equipment under test (EUT) 8 4 T E S T E N V I R O N M E N T 9 4.1 Address of the test laboratory 9 4.2 Environmental conditions 9 4.3 Statement of the measurement uncertainty 9 4.1 Measurement protocol for FCC and IC 10 4.2 Determination of worst case measurement conditions 10 5 T E S T C O N D I T I O N S A N D R E S U L T S 11 5.1 Conducted emissions 11 5.2 EBW and OBW 15 5.3 Maximum conducted output power 25 5.4 Peak power spectral density 29 5.5 Peak excursion 34 5.6 Undesirable emissions conducted 40 5.7 Undesirable emissions in restricted bands, conducted 48 5.9 Undesirable emissions, cabinet radiation 58 5.10 Frequency stability 62 5.11 Maximum permissible exposure (MPE) 65 5.12 Co-location and Co-transmission 67 5.13 Antenna application 67 6 U S E D T E S T E Q U I P M E N T A N D A C C E S S O R I E S 69 A t t a c h m e n t A a s s e p e r a t l y s u p p l e m e n t FCC ID: LYHELN1V1 IC: 267AA-ELN1V1 CSA Group Bayern GmbH File No. T36325-00-04HS, page 3 of 69 Ohmstrasse 1-4 ๏‚ž 94342 STRASSKIRCHEN ๏‚ž GERMANY Tel.:+49(0)9424-94810 ๏‚ž Fax:+49(0)9424-9481440 Rev. No. 3.0, 2014-01-31 1 T E S T S T A N D A R D S The tests were performed according to following standards: FCC Rules and Regulations Part 15, Subpart A - General (September, 2013) Part 15, Subpart A, Section 15.31 Measurement standards Part 15, Subpart A, Section 15.33 Frequency range of radiated measurements Part 15, Subpart A, Section 15.35 Measurement detector functions and bandwidths FCC Rules and Regulations Part 15, Subpart C - Intentional Radiators (September, 2013) Part 15, Subpart C, Section 15.203 Antenna requirement Part 15, Subpart C, Section 15.204 External radio frequency power amplifiers and antenna modifications Part 15, Subpart C, Section 15.205 Restricted bands of operation Part 15, Subpart C, Section 15.207 Conducted limits Part 15, Subpart C, Section 15.209 Radiated emission limits, general requirements FCC Rules and Regulations Part 15, Subpart E โ€“ Unlicensed National Information Infrastructure Devices (September, 2013) Part 15, Subpart E, Section 15.407 Operation within the bands 5.15 - 5.25 GHz, 5.25 - 5.35 GHz, 5.47 - 5.725 GHz and 5.725 - 5.825 GHz FCC Rules and Regulations Part 1, Subpart I - Procedures Implementing the National Environmental Policy Act of 1969 Part 1, Subpart I, Section 1.1310 Radiofrequency radiation exposure limits Part 1, Subpart 2, Section 2.1093 Radiofrequency radiation exposure evaluation: portable device OET Bulletin 65, 65A, 65B, 65C Edition 97-01, August 1997 โ€“ Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields. ET Docket No. 03-122, FCC 06-96 Released June 30, 2006, Memorandum Opinion and Order concerning DFS ANSI C63.4: 2009 Methods of Measurement of Radio-Noise Emissions from Low- Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz. ANSI C95.1: 2005 IEEE Standard for Safety Levels with respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz CISPR 16-4-2: 2003 Uncertainty in EMC measurement CISPR 22: 2005 Information technology equipment EN 55022: 2006 KDB 789033 D01 v01r03 Guidelines for compliance testing of UNII-Devices โ€“ Part 15, Subpart E, April 8, 2013. FCC ID: LYHELN1V1 IC: 267AA-ELN1V1 CSA Group Bayern GmbH File No. T36325-00-04HS, page 4 of 69 Ohmstrasse 1-4 ๏‚ž 94342 STRASSKIRCHEN ๏‚ž GERMANY Tel.:+49(0)9424-94810 ๏‚ž Fax:+49(0)9424-9481440 Rev. No. 3.0, 2014-01-31 2 S U M M A R Y 2.1 Test result summary Operating in the 5150 MHz - 5250 MHz: FCC Rule Part RSS Rule Part Description Result 15.207(a) RSS Gen, 7.2.4. AC power line conducted emissions passed 15.407(a) EBW 26 dB passed 15.407(a) RSS210, A9.2 Conducted output power and PSD passed 15.407(a)(6) Peak excursion passed 15.407(b) RSS210, A9.2 Undesirable emissions passed 15.205(a) RSS-Gen, 7.2.2 Emissions in restricted bands passed 15.407(g) RSS-Gen, 7.2.6 Frequency stability passed 15.407(f) RSS102, 2.5.2 Maximum permissible exposure (MPE) passed 15.407(h)(1) RSS210, A9.2 TPC not applicable 15.407(a) RSS210, A9.2 Antenna requirement passed OET Bulletin 65 RSS102, 3.2 Co-location, Co-transmission passed RSS210, A9.2 OBW 99 % passed The mentioned RSS Rule Parts in the above table are related to: RSS Gen, Issue 3, December 2010 RSS 210, Issue 8, December 2010 RSS 102, Issue 4, March 2010 FCC ID: LYHELN1V1 ICโ€ฆ

Text truncated - open the document above for the full version.

Test Report

FCC ID: LYHELN1V1 IC: 267AA-ELN1V1 CSA Group Bayern GmbH File No. T36325-00-04HS, page 1 of 72 Ohmstrasse 1-4 ๏‚ž 94342 STRASSKIRCHEN ๏‚ž GERMANY Tel.:+49(0)9424-94810 ๏‚ž Fax:+49(0)9424-9481440 Rev. No. 3.0, 2014-01-31 EMI โˆ’ T E S T R E P O R T - FCC Part 15.407 and RSS210 - Test Report No. : T36325-00-04HS 26 March 2014 ______________________________________________________________________________________________ Date of issue Type / Model Name : SCALANCE W700 / ELN Product Description : Industrial WLAN access point Applicant : Siemens AG, Industrial Automation Division Address : Gleiwitzer Strasse 555 90475 NUERNBERG, GERMANY Manufacturer : Siemens AG, Automation & Drives Address : Oestliche Rheinbrueckenstrasse 50 76187 KARLSRUHE, GERMANY Licence holder : Siemens AG, Automation & Drives Address : Oestliche Rheinbrueckenstrasse 50 76187 KARLSRUHE, GERMANY Test Result according to the standards listed in clause 1 test standards: POSITIVE The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permission of the test laboratory. FCC ID: LYHELN1V1 IC: 267AA-ELN1V1 CSA Group Bayern GmbH File No. T36325-00-04HS, page 2 of 72 Ohmstrasse 1-4 ๏‚ž 94342 STRASSKIRCHEN ๏‚ž GERMANY Tel.:+49(0)9424-94810 ๏‚ž Fax:+49(0)9424-9481440 Rev. No. 3.0, 2014-01-31 Contents 1 T E S T S T A N D A R D S 3 2 S U M M A R Y 4 2.1 Test result summary 4 2.2 General remarks 5 2.3 Final assessment 7 3 E Q U I P M E N T U N D E R T E S T 8 3.1 Photo documentation of the EUT โ€“ Detailed photos see attachment A 8 3.2 Power supply system utilised 8 3.3 Short description of the equipment under test (EUT) 8 4 T E S T E N V I R O N M E N T 9 4.1 Address of the test laboratory 9 4.2 Environmental conditions 9 4.3 Statement of the measurement uncertainty 9 4.1 Measurement protocol for FCC and IC 10 4.2 Determination of worst case measurement conditions 10 5 T E S T C O N D I T I O N S A N D R E S U L T S 11 5.1 Conducted emissions 11 5.2 EBW and OBW 15 5.3 Maximum conducted output power 25 5.4 Peak power spectral density 29 5.5 Peak excursion 34 5.6 Undesirable emissions conducted 40 5.7 Undesirable emissions in restricted bands, conducted 48 5.9 Undesirable emissions, cabinet radiation 58 5.10 Frequency stability 62 5.11 Maximum permissible exposure (MPE) 65 5.12 Co-location and Co-transmission 67 5.13 Antenna application 67 5.14 Band requirement 5150 โ€“ 5250 MHz 69 6 U S E D T E S T E Q U I P M E N T A N D A C C E S S O R I E S 72 A t t a c h m e n t A a s s e p e r a t l y s u p p l e m e n t FCC ID: LYHELN1V1 IC: 267AA-ELN1V1 CSA Group Bayern GmbH File No. T36325-00-04HS, page 3 of 72 Ohmstrasse 1-4 ๏‚ž 94342 STRASSKIRCHEN ๏‚ž GERMANY Tel.:+49(0)9424-94810 ๏‚ž Fax:+49(0)9424-9481440 Rev. No. 3.0, 2014-01-31 1 T E S T S T A N D A R D S The tests were performed according to following standards: FCC Rules and Regulations Part 15, Subpart A - General (September, 2013) Part 15, Subpart A, Section 15.31 Measurement standards Part 15, Subpart A, Section 15.33 Frequency range of radiated measurements Part 15, Subpart A, Section 15.35 Measurement detector functions and bandwidths FCC Rules and Regulations Part 15, Subpart C - Intentional Radiators (September, 2013) Part 15, Subpart C, Section 15.203 Antenna requirement Part 15, Subpart C, Section 15.204 External radio frequency power amplifiers and antenna modifications Part 15, Subpart C, Section 15.205 Restricted bands of operation Part 15, Subpart C, Section 15.207 Conducted limits Part 15, Subpart C, Section 15.209 Radiated emission limits, general requirements FCC Rules and Regulations Part 15, Subpart E โ€“ Unlicensed National Information Infrastructure Devices (September, 2013) Part 15, Subpart E, Section 15.407 Operation within the bands 5.15 - 5.25 GHz, 5.25 - 5.35 GHz, 5.47 - 5.725 GHz and 5.725 - 5.825 GHz FCC Rules and Regulations Part 1, Subpart I - Procedures Implementing the National Environmental Policy Act of 1969 Part 1, Subpart I, Section 1.1310 Radiofrequency radiation exposure limits Part 1, Subpart 2, Section 2.1093 Radiofrequency radiation exposure evaluation: portable device OET Bulletin 65, 65A, 65B, 65C Edition 97-01, August 1997 โ€“ Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields. ET Docket No. 03-122, FCC 06-96 Released June 30, 2006, Memorandum Opinion and Order concerning DFS ANSI C63.4: 2009 Methods of Measurement of Radio-Noise Emissions from Low- Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz. ANSI C95.1: 2005 IEEE Standard for Safety Levels with respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz CISPR 16-4-2: 2003 Uncertainty in EMC measurement CISPR 22: 2005 Information technology equipment EN 55022: 2006 KDB 789033 D01 v01r03 Guidelines for compliance testing of UNII-Devices โ€“ Part 15, Subpart E, April 8, 2013. FCC ID: LYHELN1V1 IC: 267AA-ELN1V1 CSA Group Bayern GmbH File No. T36325-00-04HS, page 4 of 72 Ohmstrasse 1-4 ๏‚ž 94342 STRASSKIRCHEN ๏‚ž GERMANY Tel.:+49(0)9424-94810 ๏‚ž Fax:+49(0)9424-9481440 Rev. No. 3.0, 2014-01-31 2 S U M M A R Y 2.1 Test result summary Operating in the 5150 MHz - 5250 MHz: FCC Rule Part RSS Rule Part Description Result 15.207(a) RSS Gen, 7.2.4. AC power line conducted emissions passed 15.407(a) EBW 26 dB passed 15.407(a) RSS210, A9.2 Conducted output power and PSD passed 15.407(a)(6) Peak excursion passed 15.407(b) RSS210, A9.2 Undesirable emissions passed 15.205(a) RSS-Gen, 7.2.2 Emissions in restricted bands passed 15.407(g) RSS-Gen, 7.2.6 Frequency stability passed 15.407(f) RSS102, 2.5.2 Maximum permissible exposure (MPE) passed 15.407(h)(1) RSS210, A9.2 TPC not applicable 15.407(a) RSS210, A9.2 Antenna requirement passed OET Bulletin 65 RSS102, 3.2 Co-location, Co-transmission passed RSS210, A9.2 OBW 99 % passed The mentioned RSS Rule Parts in the above table are related to: RSS Gen, Issue 3, December 2010 RSS 210, Issue 8, December 2010 RSS 102,โ€ฆ

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: LYHELN1V1 IC ID: 267AA-ELN1V1 CSA Group Bayern GmbH File No. T36325-00-04HS, page 11 of 69 Ohmstrasse 1-4 ๏‚ž 94342 STRASSKIRCHEN ๏‚ž GERMANY Tel.:+49(0)9424-94810 ๏‚ž Fax:+49(0)9424-9481440 Rev. No. 3.0, 2014-01-31 5 T E S T C O N D I T I O N S A N D R E S U L T S 5.1 Conducted emissions For test instruments and accessories used see section 6 Part A 4. 5.1.1 Description of the test location Test location: Shielded Room S2 5.1.2 Photo documentation of the test set-up 5.1.3 Applicable standard According to FCC Part 15C, Section 15.107(a) and Section 15.207(a): Except as shown in paragraphs (b) and (c) of this Section, for an intentional radiator that is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed the limits in the following table. Frequency of Emission (MHz) Conducted Limit (dBฮผV) Quasi-peak Average 0.15-0.5 66 to 56 * 56 to 46 * 0.5-5 56 46 5-30 60 50 * Decreases with the logarithm of the frequency FCC ID: LYHELN1V1 IC ID: 267AA-ELN1V1 CSA Group Bayern GmbH File No. T36325-00-04HS, page 15 of 69 Ohmstrasse 1-4 ๏‚ž 94342 STRASSKIRCHEN ๏‚ž GERMANY Tel.:+49(0)9424-94810 ๏‚ž Fax:+49(0)9424-9481440 Rev. No. 3.0, 2014-01-31 5.2 EBW and OBW For test instruments and accessories used see section 6 Part MB. 5.2.1 Description of the test location Test location: AREA 4 5.2.2 Photo documentation of the test set-up 5.2.3 Applicable standard According to FCC Part 15E, Section 15.407(i): The emission bandwidth shall be determined by measuring the width of the signal between two points, one below the carrier centre frequency and one above the carrier centre frequency, that are 26 dB down relative to the maximum of the modulated carrier. 5.2.4 Description of Measurement The bandwidth is measured conducted using a spectrum analyser and following the procedures according the OET 789033, item C. The spectrum analyser function โ€œn-dB-downโ€ is used to determine the 26 dB EBW. For the OBW the analyser function โ€œOBWโ€ is used to determine the bandwidth. The procedures according the OET 789033, item D are followed in this case. The measurement is done at the highest power setting P20. FCC ID: LYHELN1V1 IC ID: 267AA-ELN1V1 CSA Group Bayern GmbH File No. T36325-00-04HS, page 25 of 69 Ohmstrasse 1-4 ๏‚ž 94342 STRASSKIRCHEN ๏‚ž GERMANY Tel.:+49(0)9424-94810 ๏‚ž Fax:+49(0)9424-9481440 Rev. No. 3.0, 2014-01-31 5.3 Maximum conducted output power For test instruments and accessories used see section 6 Part CPC 3. 5.3.1 Description of the test location Test location: AREA 4 5.3.2 Photo documentation of the test set-up 5.3.3 Applicable standard According to FCC Part 15E, Section 15.407(a): The maximum conducted output power over the frequency band of operation shall not exceed the effective values. If transmitting antennas of directional gain are greater than 6 dBi are used, the maximum conducted output power shall be reduced by the amount in dB that the directional gain of the antenna exceeds 6 dBi. 5.3.4 Description of Measurement The output power is measured conducted using a spectrum analyser. The EUT has no constant duty cycle and may be smaller than 98% therefore the procedure according the OET 789033; item E g) Method SA-3 Alternative is followed. The EUT is set while measuring in TX continuous mode with a maximum duty cycle. The insertion loss of the measurement cable is taken into account with amplitude offset while measuring. The output power is integrated across the OBW 99 alternatively. Determination of the min VBW for AV-Measurement: Standardmin puls in TX continuous mode1/Tmin VBW (ms)(Hz) 801.11a2.0005001 kHz 801.11n, HT201.8505411 kHz 801.11n, HT400.45521983 kHz Transmission duration FCC ID: LYHELN1V1 IC ID: 267AA-ELN1V1 CSA Group Bayern GmbH File No. T36325-00-04HS, page 29 of 69 Ohmstrasse 1-4 ๏‚ž 94342 STRASSKIRCHEN ๏‚ž GERMANY Tel.:+49(0)9424-94810 ๏‚ž Fax:+49(0)9424-9481440 Rev. No. 3.0, 2014-01-31 5.4 Peak power spectral density For test instruments and accessories used see section 6 Part CPC 3. 5.4.1 Description of the test location Test location: AREA 4 5.4.2 Photo documentation of the test set-up 5.4.3 Applicable standard According to FCC Part 15E, Section 15.407(a): For the defined operating bands the peak power spectral density conducted from the intentional radiator to the antenna shall not be greater than the appropriate limit in any 1 MHz band during any time interval of continuous transmission. 5.4.4 Description of Measurement The bandwidth is measured conducted using a spectrum analyser and following the procedures according the OET 789033, item F. Since the method SA-3 alternative was used for channel power the spectrum analyser settings are the same as under item F)g). The marker function โ€œMarker to maxโ€ is used to set at peak power spectral density. For this MIMO transmitter the antenna chain 1 and chain 2 is measured and summed in linear terms over all antenna terminals of the multiple antenna systemโ€ฆ

Text truncated - open the document above for the full version.

Contact Information

Applicant

Malgorzata Janson(Dr.)
[email protected]+4972166720125Fax: +4972166720125

Technical Contact

CSA Group Bayern GmbHHermann Smetana
[email protected]4994249481250

Ohmstrasse 1-4 ยท Strasskirchen ยท Germany

Test Firm

CSA Group Bayern GmbHThomas Weise
[email protected]49-9424-9481-150Fax: 49-9424-9481-240

Technical Specifications

#Rule PartsFrequency RangePower Output
115E5.18 GHz - 5.24 GHz19.00 mW
Confidentiality
Long Term
Grant Notes
Power Output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This transmitter is restricted to indoor use only within the 5.15-5.25 GHz band. This device has a 20 MHz and 40 MHz bandwidth mode.

Other Applications from Siemens AG

LYHMRM85633M

SCALANCE MRM85633M

Aug 04, 2026

Equipment Class

CBD - Citizens Band Category A and B Devices
Vibration and temperature sensor - FCC ID LYH-MS200 - Siemens AG
LYH-MS200

Vibration and temperature sensor

May 10, 2023

Equipment Class

DTS - Digital Transmission System
MSAX-W1-RJ-E2 / MSAX-W1-RJ-E2-NO - FCC ID LYHMSAXV1 - Siemens AG
LYHMSAXV1

MSAX-W1-RJ-E2 / MSAX-W1-RJ-E2-NO

Apr 13, 2023

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
Industrial Wireless LAN Access Point Module - FCC ID LYHRAPACV1 - Siemens AG
LYHRAPACV1

Industrial Wireless LAN Access Point Module

Feb 20, 2020

Equipment Class

NII - Unlicensed National Information Infrastructure TX
WLAN N-Module - FCC ID LYHMPCIE1V1 - Siemens AG
LYHMPCIE1V1

WLAN N-Module

Jun 12, 2012

Equipment Class

NII - Unlicensed National Information Infrastructure TX