Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Siemens AG Digital Industries; Management: Cedrik Neike Process Automation; Management: Axel Lorenz Oestliche Rheinbrueckenstr. 50 76187 Karlsruhe GERMANY Tel.: +49 721 667 0 Fax: +49 721 667 21146 www.siemens.com Siemens Aktiengesellschaft: Chairman of the Supervisory Board: Jim Hagemann Snabe; Managing Board: Roland Busch, Chairman, President and Chief Executive Officer; Veronika Bienert, Peter Koerte, Cedrik Neike, Matthias Rebellius, Ralf P. Thomas, Judith Wiese Registered offices: Berlin and Munich, Germany; Commercial registries: Berlin-Charlottenburg, HRB 12300, Munich, HRB 6684 WEEE-Reg.-No. DE 23691322 SCF V12 Page 1 of 2 _ Siemens AG, DI PA DCP R&D 2, Oestliche Rheinbrueckenstr. 50, 76187 Karlsruhe, GERMANY Restricted use Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Name Dr. Malgorzata Janson Department DI PA DCP R&D 1 Telephone +49 (721) 6672-0125 E-mail [email protected] Date 2026-03-04 FCC Attestation Letter Covered Equipment Ladies and gentlemen, Attestation Section 2.911(d)(5)(i) and Section 2.911(d)(5)(ii) (KDB 986446 D01 Covered Equipment) Section 2.911(d)(5)(i) Siemens AG (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Section 2.911(d)(5)(ii) Siemens AG (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Type of Equipment subject to FCC Certification: Industrial 5G Radio Unit - SCALANCE MRM85633M FCC ID: LYHMRM85633M If you have any questions, please feel free to contact me. Letter of 2026-03-04 to Federal Communications Commission Restricted use SCF V12 Page 2 of 2 _ Sincerely yours, For Siemens Aktiengesellschaft Karlsruhe Mar. 04. 2026 Place of issue Date of issue Nina Pawlowska, i.V. Martin Ober, i.V. Name Signature Name Signature Head of Quality Management, DI PA DCP QM Vice President R&D, DI PA DCP R&D Function Function Person who is registered at FCC for the Grantee Code Malgorzata Janson Name Signature R&D Engineer, DI PA DCP R&D 1 Function Notice: Compliance with legal and internal regulations is an integral part of all business processes at Siemens. Possible violations can be reported to us at any time via our reporting channels at www.siemens.com/tell-us.
Siemens AG Digital Industries; Management: Cedrik Neike Process Automation; Management: Axel Lorenz Oestliche Rheinbrueckenstr. 50 76187 Karlsruhe GERMANY Tel.: +49 721 667 0 Fax: +49 721 667 21146 www.siemens.com Siemens Aktiengesellschaft: Chairman of the Supervisory Board: Jim Hagemann Snabe; Managing Board: Roland Busch, Chairman, President and Chief Executive Officer; Veronika Bienert, Peter Koerte, Cedrik Neike, Matthias Rebellius, Ralf P. Thomas, Judith Wiese Registered offices: Berlin and Munich, Germany; Commercial registries: Berlin-Charlottenburg, HRB 12300, Munich, HRB 6684 WEEE-Reg.-No. DE 23691322 SCF V12 Page 1 of 2 _ Siemens AG, DI PA DCP R&D 2, Oestliche Rheinbrueckenstr. 50, 76187 Karlsruhe, GERMANY Restricted use Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Name Dr. Malgorzata Janson Department DI PA DCP R&D 1 Telephone +49 (721) 6672-0125 E-mail [email protected] Date 2026-03-04 FCC Attestation Letter US Agent Ladies and gentlemen, Attestation Certification designating a U.S. Agent for Service of Process Section 2.911(d)(7) (KDB 986446 D01 Covered Equipment) Siemens AG (“the applicant”) as required by section 2.911(d)(7), designate below contact located in the United States for purposes of acting as the applicant’s agent for service of process. The applicant also accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. The US Agent confirms by the signature, that he has accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant as noted below. Type of Equipment subject to FCC Certification: Industrial 5G Radio Unit - SCALANCE MRM85633M FCC ID: LYHMRM85633M Sincerely yours, For Siemens Aktiengesellschaft Letter of 2026-03-04 to Federal Communications Commission Restricted use SCF V12 Page 2 of 2 _ Karlsruhe Mar. 04. 2026 Place of issue Date of issue Nina Pawlowska, i.V. Martin Ober, i.V. Name Signature Name Signature Head of Quality Management, DI PA DCP QM Vice President R&D, DI PA DCP R&D Function Function Person who is registered at FCC for the Grantee Code Applicant/Grantee FRN: 0014620876 Malgorzata Janson Name Signature R&D Engineer, DI PA DCP R&D 1, Siemens Function Oestliche Rheinbrueckenstraße 50ª, 76185 Karlsruhe, Germany Adress +49 (721) 6672-0125 Office Tel. [email protected] E-Mail US Agent for Service of Process ☒ FRN: 0037520764 ☐ no FRN – no other business with FCC except US Agent for service of process Zakaria Benbedda Name Signature Business Development Professional, DI S AM DM-PA PSE NAM, Siemens Function 2060 Detwiler Rd. Harleysville, PA NY 19438 United States of America Adress +1 2154213989 Office Tel. [email protected] E-Mail Notice: Compliance with legal and internal regulations is an integral part of all business processes at Siemens. Possible violations can be reported to us at any time via our reporting channels at www.siemens.com/tell-us.
Letter of to Our reference Siemens AG Digital Industries; Management: Cedrik Neike Process Automation; Management: Axel Lorenz Oestliche Rheinbrueckenstr. 50 76187 Karlsruhe Germany Tel.: +49 721 667 0 Fax: +49 721 667 21146 www.siemens.com Siemens Aktiengesellschaft: Chairman of the Supervisory Board: Jim Hagemann Snabe; Managing Board: Roland Busch, Chairman, President and Chief Executive Officer; Veronika Bienert, Peter Koerte, Cedrik Neike, Matthias Rebellius, Ralf P. Thomas, Judith Wiese Registered offices: Berlin and Munich, Germany; Commercial registries: Berlin-Charlottenburg, HRB 12300, Munich, HRB 6684 WEEE-Reg.-No. DE 23691322 SCF V12 Page 1 of 2 _ Siemens AG, DI PA DCP R&D 1, Oestliche Rheinbrueckenstr. 50, 76187 Karlsruhe Name Dr. Malgorzata Janson Department DI PA DCP R&D 1 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Telephone +49 (721) 6672-0125 E-mail [email protected] Date Apr. 15. 2026 Confidentiality Request for FCC ID: LYHMRM85633M Pursuant to CFR 47 sections 0.457 and 0.459, we respectfully request confidential treatment of the exhibits accompanying this application according to the table below: Type of Confidentiality Requested Exhibit Short Term Long Term Block Diagram Short Term External Photos Short Term Long Term *** Internal Photos Short Term Long Term Operational Description/Theory of Operation Short Term Long Term Part List Short Term Long Term Tune-Up Procedure Short Term Long Term Schematics Short Term Test Setup Photos Short Term Long Term *** User’s Manual **Automatically held Long Term Confidential *** Long Term confidentiality may be requested in accordance with FCC KDB 726920 The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: To avoid premature release of sensitive information prior to marketing or release of the product to the public, the applicant requests the following documents contained in this certification application be temporarily withheld from public disclosure for an initial period of 45 or 180 days; or for a specified date of not to exceed 180 days from the Grant Date Letter of Apr. 15. 2026 SCF V12 Page 2 of 2 _ The applicant understands that disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely yours, For Siemens Aktiengesellschaft Karlsruhe Apr. 15. 2026 Place of issue Date of issue Nina Pawlowska, i.V. Martin Ober, i.V. Name Signature Name Signature Head of Quality Management, DI PA DCP QM Vice President R&D, DI PA DCP R&D Function Function Person who is registered at FCC for the Grantee Code Malgorzata Janson Name Signature R&D Engineer, DI PA DCP R&D 1 Function
Test Laboratory: 7layers GmbH Borsigstrasse 11 40880 Ratingen Germany Note: The following test results relate only to the devices specified in this document. This report shall not be reproduced in parts without the written approval of the test laboratory. 7layers GmbH Geschäftsführer/ Borsigstraße 11 Managing Directors: Registergericht/registered: a Bureau Veritas 40880 Ratingen, Germany Martina Kerbl Düsseldorf HRB 75554 Group Company T +49 (0) 2102 749 0 Bernhard Retka USt-Id.-Nr./VAT-No. DE203159652 F +49 (0) 2102 749 350 Steuer-Nr./TAX-No. 147/5869/0385 www.7layers.com Commerzbank AG Account No. 303 016 000 Bank Code 300 400 00 IBAN DE81 3004 0000 0303 0160 00 Swift Code COBADEFF FCC RF Exposure Assessment on SCALANCE MRM85633M FCC ID: LYHMRM85633M Report Reference: MDE_SIEM_2518_MPE_01_REV01 TEST REPORT REFERENCE: MDE_SIEM_2518_MPE_01_REV01 Page 2 of 12 Contents 1 Applied Standards .................................................................................................... 3 2 Summary ................................................................................................................ 4 3 Revision History ....................................................................................................... 5 4 Administrative Data .................................................................................................. 6 4.1 Testing Laboratory ........................................................................................... 6 4.2 Project Data .................................................................................................... 6 4.3 Applicant Data ................................................................................................. 6 4.4 Manufacturer Data ........................................................................................... 6 5 Test object Data ...................................................................................................... 7 6 Assessment ............................................................................................................. 8 6.1 Assessment method and technologies of assessment ............................................ 8 6.2 Single RF Source exemption limits ...................................................................... 9 6.3 Multiple RF Source exemption limits ................................................................. 10 6.4 Calculation .................................................................................................... 12 TEST REPORT REFERENCE: MDE_SIEM_2518_MPE_01_REV01 Page 3 of 12 1 Applied Standards Type of Authorization Certification for an Intentional Radiator Applicable FCC Rules Prepared in accordance with the requirements of FCC Rules and Regulations as listed in 47 CFR Ch.1 Parts 1 and 2 (10-1-23 Edition). The following subparts are applicable to the results in this test report. Part 1, Subpart I Practice and Procedure, Procedures Implementing the National Environmental Policy Act of 1969 § 1.1307: Actions that may have a significant environmental effect, for which Environmental Assessments (EAs) must be prepared. Part 2, Subpart J Equipment Authorization Procedures, Certification § 2.1091: Radiofrequency radiation exposure evaluation: mobile devices. § 2.1093: Radiofrequency radiation exposure evaluation: portable devices. The following KDB is applied: KDB 447498 D04, v01: Interim General RF Exposure Guidance RF Exposure Procedures and Equipment Authorization Policies for Mobile and Portable Devices TEST REPORT REFERENCE: MDE_SIEM_2518_MPE_01_REV01 Page 4 of 12 2 Summary This RF-exposure evaluation according to the – in chapter 1 - mentioned rule parts and KDB shows, that the worst-case RF exposure values of the assessed radio technologies and bands are below the exemption limits of the mentioned rule parts. The following exemption rule part(s) were selected: ☐ 1-mW Test Exemption, § 1.1307(b)(3)(i)(A) 447498 D04 Interim General RF Exposure Guidance v01, 2.1.2 Per § 1.1307(b)(3)(i)(A), a single RF source is exempt RF device (from the requirement to show data demonstrating compliance to RF exposure limits, as previously mentioned) if the available maximum time-averaged power is no more than 1 mW, regardless of separation distance. This exemption applies to all operating configurations and exposure conditions, for the frequency range 100 kHz to 100 GHz, regardless of fixed, mobile, or portable device exposure conditions. This is a standalone exemption, and it cannot be applied in conjunction with any other test exemption. ☒ MPE based test exemption, § 1.1307(b)(3)(i)(C) 447498 D04 Interim General RF Exposure Guidance v01, 2.1.4 An alternative to the SAR-based exemption is provided in § 1.1307(b)(3)(i)(C), for a much wider frequency range, from 300 kHz to 100 GHz, applicable for separation distances greater or equal to λ/2π, where λ is the free-space operating wavelength in meters. The MPE-based test exemption condition is in terms of ERP, defined as the product of the maximum antenna gain and the delivered maximum time- averaged power.10 For this case, a RF source is an RF exempt device if its ERP (watts) is no more than a frequency-dependent value, as detailed tabular form in Appendix B. These limits have been derived based on the basic specifications on Maximum Permissible Exposure (MPE) considered for the FCC rules in § 1.1310(e)(1). ☐ SAR based test exemption, § 1.1307(b)(3)(i)(B) 447498 D04 Interim General RF Exposure Guidance v01, 2.1.3 A more comprehensive exemption, considering a variable power threshold that depends on both the separation distance and power, is provided in § 1.1307(b)(3)(i)(B). This exemption is applicable to the frequency range between 300 MHz and 6 GHz, with test separation distances between 0.5 cm and 40 cm, and for all RF sources in fixed, mobile, and portable device exposure conditions. Accordingly, a RF source is considered an RF exempt device if its available maximum time-aver…
Text truncated - open the document above for the full version.
© Siemens AG 2023. All rights reserved 8 C79000-G8976-C709-01, 08/2023 SIMATIC NET Industrial Wireless LAN Antenna ANT897-5FF for LTE / 5G Compact Operating Instructions Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. 1 Introduction Scope of validity of the operating instructions These compact operating instructions apply to the ANT897-5FF antenna. Product Article number ANT897-5FF 6GK5897-5FF00-0AA0 Purpose The ANT897-5FF antenna is a directional antenna with four antenna ports and weak directivity for indoor and outdoor use in private LTE and 5G mobile networks. Antenna ANT897-5FF for LTE / 5G C79000-G8976-C709-01, 08/2023 9 Scope of delivery The following components are supplied with the antenna: • One ANT897-5FF antenna with four N-Connect female connectors • One angle bracket • One fastening plate • One U-bolt for mast mounting • One set of screws consisting of: – 2 x M6x12 screws – 2 x M6 nuts – 2 x spring lock washers – 4 washers • An information sheet Please check that the consignment you have received is complete. If the consignment is incomplete, contact your supplier or your local Siemens office. Cybersecurity notes In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions constitute one element of such a concept. For more information about industrial security, please visit Industrial Security (https://www.siemens.com/industrialsecurity ) Recycling and disposal The products are low in pollutants, can be recycled and meet the requirements of the WEEE directive 2012/19/EU for the disposal of electrical and electronic equipment. Do not dispose of the products at public disposal sites. For environmentally friendly recycling and the disposal of your old device contact a certified disposal company for electronic scrap or your Siemens contact (Product return (https://support.industry.siemens.com/cs/ww/en/view/109479891 )). Note the different national regulations. 2 Safety information WARNING To avoid injury and damage, note the instructions in the operating instructions before commissioning. WARNING Danger due to lightning strikes Antennas installed outdoors must be within the area covered by a lightning protection system. • Make sure that all conducting systems entering from outdoors can be protected by a lightning protection potential equalization system. • When implementing your lightning protection concept, make sure you adhere to the VDE 0182 or IEC 62305 standard. NOTICE Improper use The device (and its components) may only be used for the application described in the catalog or the operating instructions. Combinations with devices or components of other manufacturers are permitted it they have been approved by Siemens. Correct and safe operation of the device is guaranteed only when it is transported, stored, set up, installed, used and maintained according to the recommendations. Antenna ANT897-5FF for LTE / 5G 10 C79000-G8976-C709-01, 08/2023 3 Mounting The antenna is suitable for mounting on a mast or rail with a diameter of 20–50 mm. The angle bracket allows the antenna to be tilted by up to 30°. Note Observe polarization of the antenna On the back of the antenna there is a sticker with the positions of the elements and the ports "Port 1", "Port 2", "Port 3" and "Port 4". In a standard alignment of the antenna, element 1 is at the top. With this alignment, elements 1 and 3 are horizontally polarized and elements 2 and 4 are vertically polarized. The antenna has a nominal horizontal and vertical radiating angle of approx. 60 degrees. Note Antenna power To avoid impairing proper operation, you should not mount the antenna close to overhead or high-voltage power lines. Keep a distance of at least 300 mm between the antenna and nearby metal objects and surfaces. Proceed as follows to mount the antenna: 1. Remove any oil, grease and ot…
Text truncated - open the document above for the full version.
© Siemens 2023 - 2025. All rights reserved 12 C79000-G8974-C688-03, 11/2025 SIMATIC NET Industrial Wireless LAN Antenna ANT897-5PN for LTE / 5G and IWLAN (Wi-Fi 6/7) Compact Operating Instructions Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified persons are those who, because of their training and experience, are familiar with the installation, assembly, commissioning, operation, decommissioning and disassembly of the product and can recognize risks and avoid possible hazards. Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the application described in the catalog and the associated usage information. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. 1 Introduction Scope of validity of the operating instructions These compact operating instructions apply to the ANT897-5PN antenna. Product Article number ANT897-5PN 6GK5897-5PN00-0AA0 Purpose The ANT897-5PN antenna is an omnidirectional antenna with four antenna ports for use in 5G/4G/3G/2G networks and IWLAN in the frequency range from 2300 to 7200 MHz indoors and outdoors. Antenna ANT897-5PN for LTE / 5G and IWLAN (Wi-Fi 6/7) C79000-G8974-C688-03, 11/2025 13 Scope of delivery The following components are supplied with the antenna: • An ANT897-5PN antenna with four integrated cables with N-Connector female • An information sheet Please check that the consignment you have received is complete. If the consignment is incomplete, contact your supplier or your local Siemens office. Accessories The following product can be purchased as optional accessory. Product Article number Mounting kit for mast and wall mounting 6GK5898-8HC00-0AA1 Security information In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions constitute one element of such a concept. For more information about industrial security, please visit Industrial Security (https://www.siemens.com/industrialsecurity) Recycling and disposal The products are low in pollutants, can be recycled and meet the requirements of the WEEE directive 2012/19/EU for the disposal of electrical and electronic equipment. Do not dispose of the products at public disposal sites. For environmentally friendly recycling and the disposal of your old device contact a certified disposal company for electronic scrap or your Siemens contact (Product return (https://support.industry.siemens.com/cs/ww/en/view/109479891)). Note the different national regulations. 2 Safety information WARNING To avoid injury and damage, note the instructions in the operating instructions before commissioning. WARNING Danger due to lightning strikes Antennas installed outdoors must be within the area covered by a lightning protection system. • Make sure that all conducting systems entering from outdoors can be protected by a lightning protection potential equalization system. • When implementing your lightning protection concept, make sure you adhere to the VDE 0182 or IEC 62305 standard. NOTICE Improper use The device (and its components) may only be used for the application described in the catalog or the operating instructions. Combinations with devices or components of other manufacturers are permitted it they have been approved by Siemens. Correct and safe operation of the device is guaranteed only when it is transported, stored, set up, installed, used and maintained according to the recommendations. Antenna ANT897-5PN for LTE / 5G and IWLAN (Wi-Fi 6/7) 14 C79000-G8974-C688-03, 11/2025 3 Mounting Note Degree of protection The degree of protection IP69K applies to the front side of the antenna and requires that no substances or gases can enter via the antenna port on the rear. The mounting surface must be level and mechanically stable so that the gasket of the antenna can fulfill its function. Note Antenna power To avoid impairing proper operation, do not mount the antenna close to overhead or high-voltage power lines. Also keep a distance of at least 300 mm, in the direction of radiation if possible, between the antenna and nearby metal objects and surfaces. For mounting with bracket: Attach the bracket so that the side with the mounting holes faces away from the antenna. 3.1 Mounting on a flat surface The antenna is suitable for mou…
Text truncated - open the document above for the full version.
Test Laboratory: 7layers GmbH Borsigstrasse 11 40880 Ratingen Germany Note: The following test results relate only to the devices specified in this document. This report shall not be reproduced in parts without the written approval of the test laboratory. 7layers GmbH Geschäftsführer/ Borsigstraße 11 Managing Directors: Registergericht/registered: a Bureau Veritas 40880 Ratingen, Germany Jörg-Timm Kilisch Düsseldorf HRB 75554 Group Company T +49 (0) 2102 749 0 Bernhard Retka USt-Id.-Nr./VAT-No. DE203159652 F +49 (0) 2102 749 350 Steuer-Nr./TAX-No. 147/5869/0385 www.7layers.com Commerzbank AG Account No. 303 016 000 Bank Code 300 400 00 IBAN DE81 3004 0000 0303 0160 00 Swift Code COBADEFF FCC Measurement/Technical Report on SCALANCE MRM85633M FCC ID: LYHMRM85633M Test Report Reference: MDE_SIEM_2518_FCC_02_rev1 TEST REPORT REFERENCE: MDE_SIEM_2518_FCC_02_rev1 Page 2 of 230 Table of Contents 1 Applied Standards and Test Summary 3 1.1 Applied Standards 3 1.2 FCC MEASUREMENT REQUIREMENTS Table 4 1.3 Measurement Summary 5 2 Revision History / Signatures 8 3 Administrative Data 9 3.1 Testing Laboratory 9 3.2 Project Data 9 3.3 Applicant Data 9 3.4 Manufacturer Data 9 4 Test object Data 10 4.1 General EUT Description 10 4.2 EUT Main components 11 4.3 Ancillary Equipment 12 4.4 Auxiliary Equipment 12 4.5 EUT Setups 12 4.6 Operating Modes / Test Channels 13 4.7 Product labelling 13 5 Test Results 14 5.1 RF Output Power 14 5.2 Maximum Power Spectral Density 53 5.3 Peak to Average Ratio 64 5.4 Spurious emissions at antenna terminals 72 5.5 Field strength of spurious radiation 96 5.6 Emission and occupied bandwidth 121 5.7 Band edge compliance 134 5.8 Frequency stability 208 6 Test Equipment 218 6.1 Test Equipment Hardware 218 6.2 Test Equipment Software 221 7 Antenna Factors, Cable Loss and Sample Calculations 222 7.1 LISN R&S ESH3-Z5 (150 kHz – 30 MHz) 222 7.2 Antenna R&S HFH2-Z2 (9 kHz – 30 MHz) 223 7.3 Antenna R&S HL562 (30 MHz – 1 GHz) 224 7.4 Antenna R&S HF907 (1 GHz – 18 GHz) 225 7.5 Antenna EMCO 3160-09 (18 GHz – 26.5 GHz) 226 7.6 Antenna EMCO 3160-10 (26.5 GHz – 40 GHz) 227 8 Measurement Uncertainties 228 9 Photo Report 230 TEST REPORT REFERENCE: MDE_SIEM_2518_FCC_02_rev1 Page 3 of 230 1 APPLIED STANDARDS AND TEST SUMMARY 1.1 APPLIED STANDARDS Type of Authorization Certification for a cellular device. Applicable FCC Rules Prepared in accordance with the requirements of FCC Rules and Regulations as listed in 47 CFR Ch.1 Parts 96, (08/28/2025). The following subparts are applicable to the results in this test report. Part 2, Subpart J - Equipment Authorization Procedures, Certification Part 96, Subpart E – Technical Rules § 96.41 – General radio requirements The tests were selected and performed with reference to: • FCC Public Notice 971168 applying “Measurement guidance for certification of licensed digital transmitters” 971168 D01 v02r02,2014-10-17 • FCC Public Notice 662911 applying “Emission Testing of Transmitters with Multiple Outputs in the Same Band” 662911 D01 v02r01,2013-10-31 • FCC Public Notice 940660 applying “Certification and Test Procedures for Citizens B…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 96 | 3.56 GHz - 3.69 GHz | 2.138 W | 9M59W7D | 0.00848ppm |
| 2 | 96 | 3.56 GHz - 3.69 GHz | 2.138 W | 19M8W7D | 0.00848ppm |

Vibration and temperature sensor
Equipment Class
DTS - Digital Transmission System
MSAX-W1-RJ-E2 / MSAX-W1-RJ-E2-NO
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
Industrial Wireless LAN Access Point Module
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Industrial WLAN Access Point
Equipment Class
NII - Unlicensed National Information Infrastructure TX
WLAN N-Module
Equipment Class
NII - Unlicensed National Information Infrastructure TX