Re: Certification for Siemens Transmitter Model/PN(s): 15294306, 15294307, 15294310, 15294311, 15803427, 15803428, 15780256, and 15780253 FCC ID: M3N5WY7777A IC: 267F-5WY7777A USER'S MANUAL INFORMATION (PRELIMI)ARY) The User's Manual is in preparation. The following material will be contained in the manual: FCC ID:M3N5WY7777A IC: 267F-5WY7777A This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. WARNING: Changes or modifications not expressively approved by the party responsible for compliance could void the user's authority to operate the equipment. The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were met.
RF Radio Signal LF Radio Signal ATIC37 FULLTDK5xxxF Buttons Input RDATA RFON XCLK_PULL XCLK Battery Crystal RF Antenna on the PCB RF_POWER Power Amplifier Output IN1IN2 IN3 LF Inductive antennas 315 MHz 125 kHz 9.844 MHz
Re: Certification for Siemens Transmitter FCC ID: M3N5WY7777A IC: 267F-5WY7777A REQUEST FOR CONFIDENTIALITY Pursuant to 47 CRF 0.457(d) and 0.459, Siemens requests that a part of the subject application be held confidential. TypeofConfidentialityRequestedExhibit Short Term Permanent (1) ID Label & Location Short Term Permanent (3) External Photos Short Term Permanent (4) Block Diagram Short Term Permanent (5) Schematics Short Term Permanent (7) Test Setup Photos Short Term Permanent (8) User’s Manual Short Term Permanent (9) Internal Photos Short Term Permanent (10) Parts List & Placement Short Term Permanent (11) RF Exposure Short Term Permanent (12) Description of Operation Siemens has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. PermanentConfidentiality: Siemens requests the exhibits listed above as permanently confidential be permanently withheld from public review. ShortTermConfidentiality: Siemens requests the exhibits selected above as short term confidential be withheld from public view for a period of 45 days from the date of the Grant of Equipment Authorization and prior to marketing. If there are any questions regarding this request, please contact me at the above address or call 734-483-4211, fax 734-647-2106 or e-mail [email protected]. Sincerely, Valdis V. Liepa, Research Scientist University of Michigan April 23, 2007 Re: Certification for Siemens Transmitter Model/PN(s): 15294306, 15294307, 15294310, 15294311, 15803427, 15803428, 15780256, and 15780253 FCC ID: M3N5WY7777A IC: 267F-5WY7777A STATEMENT OF MODIFICATIONS There were no modifications made to the DUT by this test laboratory. (Also see Section 3.1 of the attached Test Report). _____________________ Valdis V. Liepa Research Scientist Re: Certification for Siemens Transmitter Model/PN(s): 15294306, 15294307, 15294310, 15294311, 15803427, 15803428, 15780256, and 15780253 FCC ID: M3N5WY7777A IC: 267F-5WY7777A GENERAL PRODUCT INFORMATION The device, for which certification is pursued, has been designed by: Siemens VDO Automotive 4685 Investment Drive Troy, MI 48098 Contact: Charlie Muma [email protected] Tel: (248) 763-6783 Fax: (248) 764-7183 It will be manufactured by: Siemens VDO Automotive 4685 Investment Drive Troy, MI 48098 Contact: Charlie Muma [email protected] Tel: (248) 763-6783 Fax: (248) 764-7183 Canadian Contact: Siemens Automotive Ltd. 2775 St. Etienne Boulevard Windsor ,ON N8W 5B1 Contact: Kurt Van Drus [email protected] Tel: (519)974-5400 Fax:(519)974-5401 Re: Certification for Siemens Transmitter Model/PN(s): 15294306, 15294307, 15294310, 15294311, 15803427, 15803428, 15780256, and 15780253 FCC ID: M3N5WY7777A IC: 267F-5WY7777A POWER OF ATTORNEY A letter granting Valdis V. Liepa the Power of Attorney is on file and can be provided when so requested.
RSS-102 Annex A – RF Technical Brief Cover Sheet Application and Agreement Form for Industry Canada Certification Services APPLICANT & ADDRESS: Siemens VDO Automotive 4685 Investment Drive Troy, MI 48098 LEGAL STATUS: Corporation, LLC CONTACT NAME: Charlie Muma EMAIL ADDRESS: [email protected] TELEPHONE NO.: (248) 763-6783 FACSIMILE NO.: (248) 764-7183 MANUFACTURER & ADDRESS: Siemens VDO Automotive 4685 Investment Drive Troy, MI 48098 CONTACT NAME: Charlie Muma EMAIL ADDRESS: [email protected] TELEPHONE NO.: (248) 763-6783 FACSIMILE NO.: (248) 764-7183 CANADIAN REPRESENTATIVE & ADDRESS: Siemens Automotive Ltd. 2775 St. Etienne Boulevard Windsor ,ON N8W 5B1 CONTACT NAME: Kurt Van Drus EMAIL ADDRESS: [email protected] TELEPHONE NO.: (519)974-5400 FACSIMILE NO.: (519)974-5401 CERTIFICATION NUMBER consisting of COMPANY NUMBER AND UPN NUMBER: 267F-5WY7777A MODEL / PART NUMBER(S): 15294306, 15294307, 15294310, 15294311, 15803427, 15803428, 15780256, 15780253 SPECIFICATION STANDARD: RSP-100 / 102 / 210 / GEN and Issue No.: 6, September 2005 TYPE OF SERVICE: NEW FAMILY AGREEMENT: THE APPLICANT AGREES TO: (i) Accept responsibility for all ATCB charges arising from this application; (ii) Meet all requirements in accordance with Radio Standards Procedure 100 and other applicable procedures; (iii) Warrant that the test results submitted are a true representation of the characteristics of the radio equipment type for which certification is requested; (iv) Inform ATCB of any changes to the information submitted NAME AND TITLE OF APPLICANT (PLEASE PRINT OR TYPE): Dr. Valdis V. Liepa, Research Scientist SIGNATURE OF APPLICANT: DATE: 4/23/2007 Note: This form must be completed and provided with the submission COMPANY NUMBER OF APPLICANT: 267F MODEL / PART NUMBER(S): 15294306, 15294307, 15294310, 15294311, 15803427, 15803428, 15780256, 15780253 TYPE OF EQUIPMENT (Refer to List on Following Pages): Low Power Transmitter MANUFACTURER: Siemens VDO Automotive TESTED TO RADIO STANDARD SPECIFICATIONS (RSS) NO.: 210, GEN, 102 OPEN AREA TEST SITE INDUSTRY CANADA NUMBER: 2057 NAME OF TESTING LAB: ADDRESS OF TESTING LAB: University of Michigan / EECS 3228 EECS Building 1301 Beal Avenue Ann Arbor, Michigan 48109- 2122 USA TEST REPORT NUMBER(S) AND DATE: 415031-354 LIST OF ACCESSORIES WITH WHICH THE DEVICE WAS TESTED: None LIST OF OPERATIONAL FEATURES: Transmitter FREQUENCY RANGE (fixed frequency or from - to -): 315 MHz R.F. POWER IN WATTS (conducted/ERP/EIRP): Type: Min: Max: Stepped (Y/N): Step Value: FIELD STRENGTH (at what distance): 74.6 dBuV/m @ 3m, 315 MHz GAIN OF ANTENNAS CERTIFIED WITH THIS DEVICE: Integral OCCUPIED BANDWIDTH (99% BW): 148 kHz TYPE(S) OF MODULATION: AM, FSK EMISSION DESIGNATOR (See TRC-43 for detail): 148kL1D TRANSMITTER SPURIOUS (worst case): 39.5 dBuV/m @ 3m, 630 MHz RECEIVER SPURIOUS (worst case): ATTESTATION: I declare that the testing was performed or supervised by me; that the test measurements were made in accordance with the above- mentioned Industry Canada standard(s); and that the equipment identified in this application has been subjected to all the applicable test conditions specified in the Industry Canada standards and all of the requirements of the standard have been met. Signature: Date: 4/23/2007 NAME AND TITLE (Please print or type): Dr. Valdis V. Liepa, Research Scientist Note 1: This form must be completed and provided with the submission Note 2: This form must accompanied by an attestation letter from the applicant. Note 3: If agent is used, this form must also be accompanied by an agent authorization from the applicant. ATTESTATION: I attest: a) that when SAR or RF Exposure Evaluation testing is required and has been performed, that the information provided in Annex A is correct; b) that a Technical Brief was prepared and the information it contains is correct; that the device evaluation was performed or supervised by me; that applicable measurement methods and evaluation methodologies have been followed and that the device meets the SAR and/or RF exposure limits of RSS-102. Signature: Date: 4/23/2007 NAME (Please print or type): Dr. Valdis V. Liepa TITLE (Please print or type): Research Scientist COMPANY (Please print or type): University of Michigan / EECS Note 1: To obtain approval under this Standard, each application for certification shall be accompanied by the duly completed RF technical brief cover sheet (see Annex A) and a properly signed declaration of compliance (see Annex B). However, if the device in question meets the exemption from routine evaluation limits of Sections 2.5.1 or 2.5.2, only a properly signed declaration of compliance (Annex B) shall be submitted. Note 2: Although submission of the RF exposure technical brief is not required for certification, it shall be made available upon request, for as long as the device model is marketed in Canada. Note 3: In cases of exemption according to RSS-102, the information contained in the RF exposure technical brief may be limited to information that demonstrates how the e.i.r.p. or output power was derived. American Telecommunications Certification Body Inc. 6731 Whittier Ave, McLean, VA 22101 SECTION I - ALL ITEMS IN THIS SECTION MUST BE COMPLETED 1. Applicant’s complete, legal business name Siemens VDO Automotive FRN Number 0006725386 Engineer: 2. Applicant’s mailing address (Line 1) 4685 Investment Drive Troy, MI 48098 Examiner: 3. FCC ID: (b) Equipment Product Code (a) Grantee Code (14 characters maximum) M 3 ) 5WY7777A 4. Name, Title and Mail Stop, if any, of person at the applicant’s address to receive grant, or for contact: (See instructions) Charlie Muma 5. (a) Telephone No. (Area/Country/City Code, No. and Ext.) (b) FAX No. (Area/Country/City Code and No.) (248) 763-6783 (248) 764-7183 (c) Internet e-mail address: [email protected] SECTION II – CONTACT INFORMATION 1.(a) Instead of Applicant, original Grant shall be mailed to: Firm Name, Number, street, City,…
Text truncated - open the document above for the full version.
GM/S: 15294306 FCC ID: M3N5WY7777A IC: 267F-5WY7777A Trade Name
General Description The Corporate Fob system consists of a RF transmitter integrated into the key and a RF receiver mounted within the control unit. The transmitter is used to transmit information to the receiver for locking, unlocking, opening the trunk, starting the vehicle, and Panic function. RF messages can be transmitted by one of two means. The keypad on the key can be used for locking, unlocking, unlocking the trunk, panic, and remote start (5 button version). Lifting the door handle or pushing the start button in the vehicle will generate a LF field, which the key will respond to with a RF transmission to unlock or start the vehicle. Power Supply The transmitter is power by a single 3V CR2032 lithium battery. Buttons There are up to five buttons on the key, which are used for RKE lock, unlock, trunk, panic, and remote start. Variants There are six variants of the 215/245/295 keys. These variants are described under the device ID section. All variants are electronically identical. The differences are in the packaging. There is a four button housing, and a five button housing as well as two types of emblems. There are also two types of labels (laser etch) which help the customer differentiate between key #1 and key #2.
University of Michigan Radiation Laboratory FCC Part 15, IC RSS210/Gen Test Report %o. 415031354 Page1of19 TheUniversityofMichigan RadiationLaboratory 3228EECSBuilding AnnArbor,MI48109(2122 Tel:(734)764(0500 MeasuredRadioFrequencyEmissions From SiemensTransmitter Model(s):15294306,15294307,15294310, 15294311,15803427,15803428, 15780256,and15780253 ReportNo.415031(354 April23,2007 Copyright©2007 For: SiemensVDOAutomotive 4685InvestmentDrive Troy,MI48098 Contact: CharlesMuma Tel:(248)763(6783 Fax:(248)764(7183 PO:Verbal Testssupervisedby: Measurementsmadeby: ValdisV.Liepa Reportapprovedby:_____________________ ValdisV.Liepa TestReportPreparedby: JosephD.Brunett ResearchScientist Summary TestsforcompliancewithFCCRegulationsPart15,SubpartC,andIndustryCanadaRSS(210/GEN, wereperformedonSiemensmodel(s)15294306,15294307,15294310,15294311,15803427,15803428, 15780256,15780253.ThisdeviceissubjecttotheRulesandRegulationsasaTransmitter. IntestingcompletedonJanuary29,2007,thedevicetestedintheworstcasemettheallowed FCCspecificationsforradiatedemissionsby1.1dB(seep.6). Besidesharmonics,therewereno othersignificantspuriousemissionsfound.Theconductedemissiontestsdonotapply,sincethe deviceispoweredbya3VDCbattery. University of Michigan Radiation Laboratory FCC Part 15, IC RSS210/Gen Test Report %o. 415031354 Page2of19 1.Introduction Siemensmodels15294306,15294307,15294310,15294311,15803427,15803428,15780256,15780253 weretestedforcompliancewithFCCRegulations,Part15,adoptedunderDocket87(389,April18,1989 assubsequentlyamended,andwithIndustryCanadaRSS(210/Gen,Issue6,September2005.Thetests wereperformedattheUniversityofMichiganRadiationLaboratoryWillowRunTestRangefollowing theproceduresdescribedinANSIC63.4(2003"MethodsofMeasurementofRadio(NoiseEmissions fromLow(VoltageElectricalandElectronicEquipmentintheRangeof9kHzto40GHz".TheSite descriptionandattenuationcharacteristicsoftheOpenAreaTesSiteareonfilewithFCCLaboratory, Columbia,Maryland(FCCReg.No:91050)andwithIndustryCanada,Ottawa,ON(FileRef.No:IC 2057). 2.TestProcedureandEquipmentUsed ThepertinenttestequipmentcommonlyusedinourfacilityformeasurementsislistedinTable2.1 below.Themiddlecolumnidentifiesthespecificequipmentusedinthesetests. Table2.1TestEquipment. TestInstrumentEqpt.UsedManufacturer/Model SpectrumAnalyzer(0.1(1500MHz)Hewlett(Packard,182T/8558B SpectrumAnalyzer(9kHz(22GHz)XHewlett(Packard8593ASN:3107A01358 SpectrumAnalyzer(9kHz(26GHz)XHewlett(Packard8593E,SN:3412A01131 SpectrumAnalyzer(9kHz(26GHz)Hewlett(Packard8563E,SN:3310A01174 SpectrumAnalyzer(9kHz(40GHz)Hewlett(Packard8564E,SN:3745A01031 PowerMeterHewlett(Packard,432A PowerMeterAnritsu,ML4803A/MP HarmonicMixer(26(40GHz)Hewlett(Packard11970A,SN:3003A08327 HarmonicMixer(40(60GHz)Hewlett(Packard11970U,SN:2332A00500 HarmonicMixer(75(110GHz)Hewlett(Packard11970W,SN:2521A00179 HarmonicMixer(140(220GHz)PacificMillimeterProd.,GMA,SN:26 S(BandStd.GainHornS/A,ModelSGH(2.6 C(BandStd.GainHornUniversityofMichigan,NRLdesign XN(BandStd.GainHornUniversityofMichigan,NRLdesign X(BandStd.GainHornS/A,Model12(8.2 X(bandhorn(8.2(12.4GHz)Narda640 X(bandhorn(8.2(12.4GHz)ScientificAtlanta,12(8.2,SN:730 K(bandhorn(18(26.5GHz)FXR,Inc.,K638KF Ka(bandhorn(26.5(40GHz)FXR,Inc.,U638A U(bandhorn(40(60GHz)CustomMicrowave,HO19 W(bandhorn(75(110GHz)CustomMicrowave,HO10 G(bandhorn(140(220GHz)CustomMicrowave,HO5R BiconeAntenna(30(250MHz)XUniversityofMichigan,RLBC(1 BiconeAntenna(200(1000MHz)XUniversityofMichigan,RLBC(2 DipoleAntennaSet(30(1000MHz)XUniversityofMichigan,RLDP(1,(2,(3 DipoleAntennaSet(30(1000MHz)EMCO2131C,SN:992 ActiveRodAntenna(30Hz(50MHz)EMCO3301B,SN:3223 ActiveLoopAntenna(30Hz(50MHz)EMCO6502,SN:2855 Ridge(hornAntenna(300(5000MHz)XUniversityofMichigan Amplifier(5(1000MHz)XAvantak,A11(1,A25(1S Amplifier(5(4500MHz)XAvantak Amplifier(4.5(13GHz)Avantek,AFT(12665 Amplifier(6(16GHz)Trek Amplifier(16(26GHz)Avantek LISNBoxUniversityofMichigan SignalGeneratorHewlett(Packard8657B University of Michigan Radiation Laboratory FCC Part 15, IC RSS210/Gen Test Report %o. 415031354 Page 3 of 19 3.DeviceUnderTest 3.1Identification The DUT is a 315 MHz transmitter, 1.5 x 0.25 x 1 inches in size. The DUT transmits ASK and FSK data and its carrier is PLL generated, sourced from a 9.844 MHz reference crystal. The antenna is a trace on the PCB. The DUT was designed and manufactured by Siemens VDO Automotive, 4685 Investment Drive, Troy, MI 48098. It is identified as: Siemens Transmitter Model(s): 15294306, 15294307, 15294310, 15294311, 15803427, 15803428, 15780256, 15780253 FCC ID: M3N5WY7777A IC: 267F-5WY7777A 3.2ModesofOperation The device is capable of transmitting 3 different modulations at two different peak power levels. The highest peak power (HP) setting utilizes a greater duty cycle. The normal peak power (NP) setting contains a transmission with greater on time. Remote Start (RS) and Remote Keyless Entry (RKE) modes are software programmed to transmit either a 2.84 kb/s ASK or 9.6 kb/s ASK when actuated by button press (depending on DUT model). Some models of the device can be remotely actuated via encoded LF (125 kHz) interrogation, transmitting 9.6 kb/s ASK modulation or a 9.6 kb/s FSK modulation. Note: The DUT is manually activated (both for button press and LF, as the user must lift the door…
Text truncated - open the document above for the full version.
1301 Beal Ave. · Ann Arbor · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 315 MHz - 315 MHz | - |

LF Transmitter
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
KeyFob
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
RCKF2B
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
FCA WL/WS PASE System MY 2021
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Car Key
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver