FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Hunter Industries Inc/
  3. M3U-RPT

M3U-RPTRepeater

Hunter Industries Inc
Repeater - FCC ID M3U-RPT - Hunter Industries Inc
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 06, 2024
Application Purpose
Original Equipment
Date of Application
Aug 06, 2024
Equipment Note
Repeater
Frequency Range
914.96800000 - 921.00000000
Company
Hunter Industries Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗
↗
↗

ID Label/Location Info

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Repeater INSTALLATION GUIDE RPT, RPT-E Solar-Powered Wireless Repeater 2 Solar-Powered Wireless Hunter Repeater ES EN El Repetidor está diseñado para su instalación en exteriores con energía solar. Retransmite señales LoRa entre dispositivos inalámbricos Hunter para ampliar el alcance inalámbrico y superar obstáculos en las comunicaciones en la línea de mira (LOS). El Repetidor incluye un panel solar integrado, una batería recargable LiFePO (fosfato de hierro y litio) y un soporte de montaje universal. (Es posible que se necesiten accesorios de montaje adicionales; por ejemplo, abrazaderas de banda de acero inoxidable The Repeater is designed for outdoor, solar-powered installation. It relays LoRa ® Radio signals between Hunter wireless devices to extend wireless range and overcome obstacles to line-of-sight (LOS) communications. The Repeater includes a built-in solar panel, a rechargeable LiFePO (lithium iron phosphate) battery, and a universal mounting bracket. (Additional mounting hardware may be required; for example, stainless steel band clamps for pole mounting.) It does not require an external power supply, and there is no external wiring of any kind. Note: There is a maximum of one Repeater allowed per controller in the Wireless Valve Link System. SOLAR PANEL ANTENNA MOUNTING BRACKET 3 Solar-Powered Wireless Hunter Repeater FR Ce répéteur est conçu pour être installé à l'extérieur et alimenté par l'énergie solaire. Il relaie les signaux LoRa entre les appareils sans fil Hunter afin d'étendre la portée sans fil et de surmonter les problèmes d'obstacles dans les communications en visibilité directe. Le répéteur comprend un panneau solaire intégré, une batterie rechargeable LiFePO (phosphate au lithium en fer) et un support de fixation universel. (D'autres pièces de fixation supplémentaires peuvent être nécessaires, telles que des colliers de serrage en acier inoxydable pour le montage sur poteau.) Il ne nécessite pas d'alimentation externe et il n'y a pas de câblage externe d'aucune sorte. Remarque : un seul répétiteur est autorisé par programmateur dans le système Wireless Valve Link. para montaje en poste). No necesita una fuente de alimentación externa y no tiene ningún tipo de cableado externo. Nota: Se permite un máximo de un Repetidor por programador en el Sistema Wireless Valve Link. The LoRa ® Mark is a trademark of Semtech Corporation or its subsidiaries. 4 Location EN ES FR The Repeater should be placed in a sunny, outdoor location with the solar panel positioned to receive maximum sunlight. It communicates directly between the Wireless Valve Output Module (WVOM) in the controller and the linked devices in the field. The Repeater is most effective when it's at the highest practical elevation, with a reasonably clear line-of-sight to the controller and the devices to be connected. Not all devices will use the Repeater; if they can hear the controller directly, they will use that. Only the more distant devices will choose to use the Repeater. The antenna can be rotated and should be positioned as close to vertical as possible. The detent on the antenna is used to set the solar panel angle. When the antenna is positioned vertically, either up or down, the solar panel is at the optimum angle. El Repetidor debe colocarse en un lugar soleado y al aire libre, con el panel solar colocado de forma que reciba la máxima luz solar posible. Se comunica directamente entre el módulo Wireless Valve Output del programador y los dispositivos vinculados sobre el terreno. El Repetidor es más eficaz cuando se encunetra a la mayor elevación posible, con una línea de visión Le répéteur doit être placé à l'extérieur dans un endroit ensoleillé et le panneau solaire doit être positionné de manière à recevoir un maximum de lumière du soleil. Il communique directement entre le module de sortie d'électrovanne sans fil du programmateur et les appareils qui y sont connectés sur le terrain. Pour optimiser l'efficacité du répéteur, placez-le le plus haut possible, avec une ligne de visée raisonnablement dégagée entre lui et le programmateur et les appareils à connecter. Tous les appareils n'utilisent pas nécessairement le répétiteur ; s'ils peuvent directement recevoir les signaux du programmateur, ils ne passeront pas par le répétiteur. Seuls les appareils les plus éloignés choisissent d'utiliser le répétiteur. razonablemente clara hacia el programador y los dispositivos que se van a conectar. No todos los dispositivos utilizarán necesariamente el Repetidor; si pueden recibir señales directamente del programador, no pasarán por el Repetidor. Solo los dispositivos más alejados elegirán utilizar el Repetidor. La antena puede girarse y debe colocarse lo más vertical posible. El soporte de la antena se utiliza para ajustar el ángulo del panel solar. Cuando la antena esté en posición vertical, hacia arriba o hacia abajo, el panel solar estará en el ángulo óptimo. 5 Installation CONNECTOR RECEPTACLE DOOR SCREW BATTERY STORAGE RESET BUTTON SERIAL NUMBER LOCATION L'antenne peut être tournée et doit être positionnée le plus près possible de la verticale. Le cran situé sur l'antenne permet de régler l'angle du panneau solaire. Lorsque l'antenne est positionnée verticalement, vers le haut ou vers le bas, l'angle du panneau solaire est optimal. 6 Installation EN Open the battery compartment using a small screwdriver. Connect the battery using the small modular connector on the wires. Do not force the connector; only one way is valid. The LED will flash green when it's connected. Abra el compartimento de la batería con un destornillador pequeño. Conecte la batería utilizando el pequeño conector modular de los cables. No fuerce el conector; solo hay una forma válida. El LED parpadeará en verde cuando esté conectada. Ouvrez le compartiment de la batterie à l'aide d'un petit tournevis. Branchez la batterie à l'aide du petit connecteur modulaire situé sur les fils. Ne forcez pas sur le connecteur, il n'y a qu'un seul se…

Text truncated - open the document above for the full version.

Attestation Statements

HUNTER INDUSTRIES 1940 Diamond Street San Marcos, CA 92078 1 760-744-5240 Main 1 800-733-2823 Support 1 760-744-7461 Fax hunterindustries.com February 1, 2024 Federal Communications Commissions Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 RE: CFR 47 §2.911 (d)(7) Agent Designation Attestation FCC ID: M3U-WVL, M3URPT, and M3U-WVOM To Whom It May Concern: Hunter Industries Inc. (“the applicant”) as required by section §2.911(d)(7), will also serve as the agent for service of process for the above referenced FCC IDs. The applicant acknowledges that they will maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility under CFR 47 §2.929(c) to inform the FCC whenever the agent information changes. Satoshi Kuwahara Hunter Industries Inc. FCC FRN: 0011558756 1940 Diamond St, San Marcos, CA 92078 [email protected] Best Regards, Satoshi Kuwahara, Director Product Integrity Hunter Industries, Inc 1940 Diamond St, San Marcos, CA 92078

Attestation Statements

HUNTER INDUSTRIES 1940 Diamond Street San Marcos, CA 92078 1 760-744-5240 Main 1 800-733-2823 Support 1 760-744-7461 Fax hunterindustries.com February 1, 2024 Federal Communications Commissions Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 RE: CFR 47 §2.911 (d)(5) Attestation FCC ID: M3U-WVL, M3URPT, and M3U-WVOM Hunter Industries Inc. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Hunter Industries Inc. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment and is not an affiliate or subsidiary of an entity identified on the Covered List. Best Regards Satoshi Kuwahara Director Product Integrity Hunter Industries, Inc

Cover Letter(s)

HUNTER INDUSTRIES 1940 Diamond Street San Marcos, CA 92078 1 760-744-5240 Main 1 800-733-2823 Support 1 760-744-7461 Fax hunterindustries.com August 4, 2024 Attn: FCC Office of Engineering and Technology / UL Verification Services TCB Subject: Request for Confidentiality FCC ID: M3U-WVL, M3URPT and M3U-WVOM To Whom It May Concern: Pursuant to the provisions of Sections 0.457 and 0.459 of the Commission’s rules (47 CFR §§ 0.457, 0.459), we are requesting the Commission to withhold the following attachments as confidential document from public disclosure indefinitely. • Schematic Diagram • Block Diagram • Theory of Operation Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Best Regards, Satoshi Kuwahara, Director Product Integrity Hunter Industries, Inc

Cover Letter(s)

HUNTER INDUSTRIES 1940 Diamond Street San Marcos, CA 92078 1 760-744-5240 Main 1 800-733-2823 Support 1 760-744-7461 Fax hunterindustries.com January 5, 2024 UL LLC 12 Laboratory Dr. Research Triangle Park, NC 27709 USA To whom it may concern: I, the undersigned, hereby authorize UL LLC to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by UL LLC on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing UL LLC as our representative, we still recognize that we are responsible to: a) fulfill the requirements for the scope of certification requested, including implementing any appropriate changes requested by UL Verification Services Telecommunications Certification Body (TCB) and / or the FCC; b) supply any and all information needed for the evaluation of the products for which certification is sought; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) not use our product certification in such a manner as to bring the TCB or FCC into disrepute and to not make any statement regarding product certification which the TCB or FCC may consider misleading or unauthorized; e) discontinue use of all advertising matter that contains any reference thereto and complies with any and all actions required by the FCC upon suspension or cancellation of certification; f) use certification only to indicate that products are certified in conformity with specified standards; g) endeavor to ensure that no certificate or report or any part thereof is used in a misleading manner, and any copies of the grants/certificates shall be reproduced in their entirety; h) comply with the requirements of the TCB and FCC, including the use of marks and label information prescribed for the scope of certification, when making reference to product certification in communication media such as documents, brochure or advertisements; i) comply with the requirements for certification, supply any information needed for evaluation of products to be certified and, where applicable, make provision for the participation of observers; j) ensure that products marketed under the scope of the requested certification continue to comply with the certification requirements; k) provide a sample of a production unit for testing within 30 days of the request should this product be selected as part of either the TCB’s or the FCC’s market surveillance requirements; l) keep a record of all complaints relating to product’s compliance with requirements of relevant standard; make records available to UL or FCC when requested; take appropriate action with respect to such complaints and any deficiencies found in the product that affect compliance with requirements for certification; document the actions taken with respect to complaints and/or deficiencies; m) inform the TCB immediately of any changes that may affect its ability to comply with the certification requirements. This authorization is valid until further written notice from the applicant. Sincerely Yours, Satoshi Kuwahara, Director Product Integrity Hunter Industries, Inc.

RF Exposure Info

FCC Part 1 Subpart I FCC Part 2 Subpart J RSS 102 ISSUE 6 RF EXPOSURE REPORT FOR REPEATER MODEL NUMBER: RPT FCC ID: M3URPT IC: 2772A-RPT REPORT NUMBER: R14970733-E3 ISSUE DATE: 2024-07-16 Prepared for HUNTER INDUSTRIES 1940 DIAMOND STREET SAN MARCOS, CA 92078-5120, USA Prepared by UL LLC 12 LABORATORY DR. RESEARCH TRIANGLE PARK, NC 27709 USA TEL: (919) 549-1400 REPORT NO: R14970733-E3 DATE: 2024-07-16 FCC ID: M3URPT IC: 2772A-RPT Page 2 of 11 UL LLC FORM NO: 03-EM-F00858 12 Laboratory Dr., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. REVISION HISTORY Ver. Issue Date Revisions Revised By V1 2024-01-25 Initial Issue Brian T. Kiewra V2 2024-06-07 Updated Output Power and Antenna Gain Noah Bennett V3 2024-07-05 Updated Antenna Gain Noah Bennett V4 2024-07-16 Updated Output Power Noah Bennett REPORT NO: R14970733-E3 DATE: 2024-07-16 FCC ID: M3URPT IC: 2772A-RPT Page 3 of 11 UL LLC FORM NO: 03-EM-F00858 12 Laboratory Dr., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. TABLE OF CONTENTS REVISION HISTORY .............................................................................................................. 2 1. ATTESTATION OF TEST RESULTS ................................................................................ 4 2. TEST METHODOLOGY ................................................................................................... 5 3. REFERENCES ................................................................................................................. 5 4. FACILITIES AND ACCREDITATION ................................................................................ 5 5. DECISION RULES AND MEASUREMENT UNCERTAINTY ............................................. 6 5.1. METROLOGICAL TRACEABILITY............................................................................. 6 5.2. DECISION RULES .................................................................................................... 6 5.3. MEASUREMENT UNCERTAINTY ............................................................................. 6 6. MAXIMUM PERMISSIBLE EXPOSURE (LIMITS AND EQUATIONS) ............................... 7 6.1. FCC RULES .............................................................................................................. 7 6.2. ISED RULES ............................................................................................................. 8 6.3. EQUATIONS ............................................................................................................. 9 7. RF EXPOSURE RESULTS............................................................................................. 11 REPORT NO: R14970733-E3 DATE: 2024-07-16 FCC ID: M3URPT IC: 2772A-RPT Page 4 of 11 UL LLC FORM NO: 03-EM-F00858 12 Laboratory Dr., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. 1. ATTESTATION OF TEST RESULTS COMPANY NAME: Hunter Industries 1940 Diamond Street San Marcos, CA 92078-5120, USA EUT DESCRIPTION: Repeater MODEL: RPT SAMPLE RECEIPT DATE: 2021-08-27 DATE TESTED: 2021-09-13 APPLICABLE STANDARDS STANDARD TEST RESULTS FCC PART 1 SUBPART I & PART 2 SUBPART J Complies RSS 102 ISSUE 6 Complies UL LLC. tested the above equipment in accordance with the requirements set forth in the above standards. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. All samples tested were in good operating condition throughout the entire test program. Measurement Uncertainties are published for informational purposes only and were not taken into account unless noted otherwise. This document may not be altered or revised in any way unless done so by UL LLC. and all revisions are duly noted in the revisions section. Any alteration of this document not carried out by UL LLC. will constitute fraud and shall nullify the document. This report must not be used by the client to claim product certification, approval, or endorsement by A2LA, NIST, or any agency of the U.S. government. Approved & Released For UL LLC by: Prepared By: Michael Antola Brian T. Kiewra Staff Engineer Project Engineer CONSUMER TECHNOLOGY DIVISION CONSUMER TECHNOLOGY DIVISION UL LLC UL LLC REPORT NO: R14970733-E3 DATE: 2024-07-16 FCC ID: M3URPT IC: 2772A-RPT Page 5 of 11 UL LLC FORM NO: 03-EM-F00858 12 Laboratory Dr., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. 2. TEST METHODOLOGY All calculations were made in accordance with FCC Parts 1.1310, 2.1091, 2.1093, KDB 447498 D01 v06, KDB 447498 D03 V01, IEEE Std C95.1-2005, IEEE Std C95.3-2002, IC Safety Code 6 and RSS 102 Issue 5. 3. REFERENCES Output power and Antenna gain data is excerpted from product documentation provided by the applicant. 4. FACILITIES AND ACCREDITATION UL LLC is accredited by A2LA, certification #0751.06, for all testing performed within the scope of this report. Testing was performed at the locations noted below. Address ISED CABID ISED Company Number FCC Registration Building: 12 Laboratory Dr RTP, NC 27709, U.S.A US0067 2180C 703469 ☒ Building: 2800 Perimeter Park Dr Morrisville, NC 27560, U.S.A 27265 REPORT NO: R14970733-E3 DATE: 2024-07-16 FCC ID: M3URPT IC: 2772A-RPT Page 6 of 11 UL LLC FORM NO: 03-EM-F00858 12 Laboratory Dr., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. 5. DECISION RULES AND MEASUREMENT…

Text truncated - open the document above for the full version.

Test Report

This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions/General-Conditions-of-Services-NorthAm.aspx and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/terms-e-document.aspx. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated, the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained until the customer requests them to be shipped back or SGS contacts the customer for approval to return them. SGS North America, Inc. Test Report Report No.: 208845 Date: May 23, 2024 Page 1 of 13 SGS BOSS No.: 5183686 Manufacturer’s Name: Hunter Industries The following sample(s) was/were submitted and identified by/on-behalf of the client as a mobile terminal device. Product Name 902 MHz – 928 MHz Antenna Model Name 906900 Description The 902 – 928 MHz Antenna was tested alone, but is mounted inside the device models WVL and RPT Board S/N N/A Testing Start Date 05/15/2024 Testing End Date 05/15/2024 Test(s) Requested Passive Antenna Performance Signed for and on behalf of SGS North America, Inc. Sergio Garcia Fred Jeong __ Senior Engineer OTA Lab Manager General Conditions of Service for North America 1. General (a) Unless otherwise agreed in writing or except where they are at variance with (i) the regulations governing services performed on behalf of governments, government bodies or any other public entity or (ii) the mandatory provisions of local law, all offers or services and all resulting contractual relationship(s) between any of the affiliated companies of SGS North America Inc. or any of their agents (each a “Company”) and Client (the “Contractual Relationship(s)”) shall be governed by these general conditions of service (hereinafter the “General Conditions”). (b) The Company may perform services for persons or entities (private, public or governmental) issuing instructions (hereinafter, the “Client”). © Unless the Company receives prior written instructions to the contrary from Client, no other party is entitled to give instructions, particularly on the scope of the services or the delivery of reports or certificates resulting therefrom (the “Reports of Findings”). Client hereby irrevocably authorize the Company to deliver Reports of Findings to a third party where so instructed by Client or, at its discretion, where it implicitly follows from circumstances, trade custom, usage or practice. 2. Provision of Services (a) The Company will provide services using reasonable care and skill and in accordance with Client’s specific instructions as confirmed by the Company or, in the absence of such instructions: (1) the terms of any standard order form or standard specification sheet of the Company; and/or (2) any relevant trade custom, usage or practice; and/or (3) such methods as the Company shall consider appropriate on technical, operational and/or financial grounds. (b) Information stated in Reports of Findings is derived from the results of inspection or testing procedures carried out in accordance with the instructions of Client, and/or our assessment of such results on the basis of any technical standards, trade custom or practice, or other circumstances which should in our professional opinion be taken into account. © Reports of Findings issued further to the testing of samples contain the Company’s opinion on those samples only and do not express any opinion upon the lot from which the samples were drawn. (d) Should Client request that the Company witness any third party intervention, Client agrees that the Company’s sole responsibility is to be present at the time of the third party’s intervention and to forward the results, or confirm the occurrence, of the intervention. Client agrees that the Company is not responsible for the condition or calibration of apparatus, instruments and measuring devices used, the analysis methods applied, the qualifications, actions or omissions of third party personnel or the analysis results. © Reports of Findings issued by the Company will reflect the facts as recorded by it at the time of its intervention only and within the limits of the instructions received or, in the absence of such instructions, within the limits of the alternative parameters applied as provided for in clause 2(a). The Company is under no obligation to refer to, or report upon, any facts or circumstances which are outside the specific instructions received or alternative parameters applied. (f) The Company may delegate the performance of all or part of the services to an agent or subcontractor and Client uthorizat Company to disclose all information necessary for such performance to the agent or subcontractor. (g) Should Company receive documents reflecting engagements contracted between Client and third parties or third party documents, such as copies of sale contracts, letters of credit, bills of lading, etc., they are considered to be for information only, and do not extend or restrict the scope of the services or the obligations accepted by the Company. (h) Client acknowledges that the Com…

Text truncated - open the document above for the full version.

Test Report

TEST REPORT Report Number: R14970733-E1 Applicant : Hunter Industries 1940 Diamond St. San Marcos, CA 92078, United States Model : RPT FCC ID : M3URPT IC : 2772A-RPT EUT Description : Repeater Test Standard(s) : FCC 47 CFR PART 15 SUBPART C: 2023 ISED RSS-247 ISSUE 3: 2023 ISED RSS-GEN ISSUE 5 + A2:2021 Date Of Issue: 2024-07-05 Prepared by: UL LLC 12 Laboratory Dr. Research Triangle Park, NC 27709 U.S.A. TEL: (919) 549-1400 REPORT NO: R14970733-E1 DATE: 2024-07-0 5 FCC ID: M3URPT IC: 2772A-RPT Page 2 of 32 UL LLC 12 Laboratory Dr., RTP, NC 27709; USA TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC REPORT REVISION HISTORY Rev. Issue Date Revisions Revised By V1 2023-10-27 Initial Issue Charles Moody V2 2024-06-04 Updated Cal dates for Equipment ID: HI0092 Noah Bennett V3 2024-07-05 Updated Antenna Gain Noah Bennett REPORT NO: R14970733-E1 DATE: 2024-07-0 5 FCC ID: M3URPT IC: 2772A-RPT Page 3 of 32 UL LLC 12 Laboratory Dr., RTP, NC 27709; USA TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC TABLE OF CONTENTS REPORT REVISION HISTORY ..................................................................................................2 TABLE OF CONTENTS .............................................................................................................3 1. ATTESTATION OF TEST RESULTS ..................................................................................5 2. TEST RESULTS SUMMARY ...............................................................................................6 3. TEST METHODOLOGY ......................................................................................................6 4. FACILITIES AND ACCREDITATION ..................................................................................6 5. DECISION RULES AND MEASUREMENT UNCERTAINTY ...............................................7 5.1. METROLOGICAL TRACEABILITY ...............................................................................7 5.2. DECISION RULES ........................................................................................................7 5.3. MEASUREMENT UNCERTAINTY ................................................................................7 5.4. SAMPLE CALCULATION .............................................................................................7 6. EQUIPMENT UNDER TEST ................................................................................................8 6.1. EUT DESCRIPTION .....................................................................................................8 6.2. MAXIMUM OUTPUT POWER .......................................................................................8 6.3. DESCRIPTION OF AVAILABLE ANTENNAS ...............................................................8 6.4. SOFTWARE AND FIRMWARE .....................................................................................8 6.5. WORST-CASE CONFIGURATION AND MODE ...........................................................8 6.6. DESCRIPTION OF TEST SETUP .................................................................................9 7. MEASUREMENT METHOD...............................................................................................10 8. TEST AND MEASUREMENT EQUIPMENT ......................................................................11 9. ANTENNA PORT TEST RESULTS ...................................................................................13 9.1. ON TIME AND DUTY CYCLE .....................................................................................13 9.2. 99% BANDWIDTH ......................................................................................................14 9.2.1. LoRa ....................................................................................................................14 9.3. 6 dB BANDWIDTH ......................................................................................................15 9.3.1. LoRa ....................................................................................................................15 9.4. OUTPUT POWER .......................................................................................................16 9.4.1. LoRa ....................................................................................................................16 9.5. AVERAGE POWER ....................................................................................................17 9.5.1. LoRa ....................................................................................................................17 9.6. POWER SPECTRAL DENSITY ..................................................................................18 9.6.1. LoRa ....................................................................................................................18 REPORT NO: R14970733-E1 DATE: 2024-07-0 5 FCC ID: M3URPT IC: 2772A-RPT Page 4 of 32 UL LLC 12 Laboratory Dr., RTP, NC 27709; USA TEL: (919) 549-1400 This report shall not be reproduced except in full, without the writt…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Satoshi Kuwahara(Director, Product Integrity)
[email protected](760)304-7453Fax: 760-471-7599

Test Firm

UL LLCSteven Thompson
[email protected]919 549 1430

Technical Specifications

#Rule PartsFrequency RangePower Output
115C914.968 MHz - 921 MHz21.28 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other transmitter. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Hunter Industries Inc

M3URMLR

Remote

May 21, 2026

Equipment Class

DTS - Digital Transmission System
LoRa Radio Module - FCC ID M3UA2CLORA - Hunter Industries Inc
M3UA2CLORA

LoRa Radio Module

Apr 28, 2026

Equipment Class

DTS - Digital Transmission System
Wireless Valve Link - FCC ID M3U-WVL - Hunter Industries Inc
M3U-WVL

Wireless Valve Link

Aug 18, 2024

Equipment Class

DTS - Digital Transmission System
Quick plug-in controller - FCC ID M3U-WVOM - Hunter Industries Inc
M3U-WVOM

Quick plug-in controller

Aug 18, 2024

Equipment Class

DTS - Digital Transmission System
Bluetooth Hose Timer - FCC ID M3UBTT1 - Hunter Industries Inc
M3UBTT1

Bluetooth Hose Timer

Feb 25, 2021

Equipment Class

DTS - Digital Transmission System