FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Hunter Industries Inc/
  3. M3UBTT1

M3UBTT1Bluetooth Hose Timer

Hunter Industries Inc
Bluetooth Hose Timer - FCC ID M3UBTT1 - Hunter Industries Inc
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Feb 25, 2021
Application Purpose
Original Equipment
Date of Application
Feb 25, 2021
Equipment Note
Bluetooth Hose Timer
Frequency Range
2402.00000000 - 2480.00000000
Company
Hunter Industries Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗
↗

Internal Photos

↗
↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Cycling Mode Programming Cycling mode allows the Run Time to repeat continually after the scheduled interval (Soak Time) from a Start Time to an End Time. 1. Under schedule, select the Pencil icon for the desired zone number. 2. Select the Cycling Mode option. 3. Water Days: Select the desired water days. Save and Confirm. 4. Start Times: Set START TIME 1 and optional START TIME 2. Save and Confirm. 5. End Times: Set END TIME 1 and optional END TIME 2. Save and Confirm. 6. Run Time: Set the desired RUN TIME from 1 second to 24 hours. Save and Confirm. 7. Soak Time: Set optional SOAK TIME, the time between each Run Time interval, from 1 second to 24 hours. Save and Confirm. Manual Watering • For manual watering, press Schedule , press the Play button, select a zone or Run All. Enter a runtime up to 360 minutes and press Run. • Set Custom Push-Button Manual Run Time: In controller settings under zones, select a zone. Select Manual Run Time and set run time from 1 to 60 minutes. Save and confirm. Additional Settings • Renaming your BTT: Press More , select controller, select controller and serial number and enter a name in Nickname section. Save and Confirm. • Press More , select the controller and enter a 4 digit passcode in the Create Passcode section. To disable, press Disable Passcode. Save and confirm. • Changing the Language: Press More , select App Settings, then Language. Select the desired language. Save and Confirm. • Suspend Watering: Press More . Select controller/serial number. Under advanced settings, select suspend watering. Set from 1-99 days. Save. • Zone Off Mode: Press More , select the controller/serial number. Select the desired zone to turn off. Toggle slider to turn off watering. Troubleshooting ProblemSolution Controller not appearing in scan list Loses connection Can’t connect or app errors Move closer than 32' (10 m) of controller. Verify battery strength and cycle the batteries. Uninstall and reinstall Hunter BTT app. Accept permissions: “Location Tracking” or manually enable permissions in smartphone settings. Reboot smartphone. Reset phone network settings. Reconnect controller. Manual button press not responding Replace the batteries (two AA alkaline batteries). App indicates watering, but none is occurring Turn on water supply. Repeat manual watering within the app or on controller. Automatic irrigation does not start at start time Verify controller is programmed for automatic watering; correct Start Times, Run Time and Watering Days. Controller waters more than one time Eliminate controller start times as needed. Correct the Soak Time in Cycling mode. Incorrect passcodeRemove and replace batteries. Go back to the app and connect. Equipment Protection • Water pressure requirements: Make sure your water pressure is 7-116 PSI (0.5-8 bar/50-800 kPa). • Make sure water is clean and particle-free. • Maximum inlet water temperature: 100°F (38°C) • Operating temperature: 41°F to 140°F (5°C to 60°C) • Protect against freezing: Do not allow water to freeze in the tap timer or in any connected hose. • Chemicals: Do not use the tap timer with or to dispense any chemicals of any kind. • Do not open: The tap timer requires no maintenance and contains no user-serviceable parts. • Periodic inspection of connections is recommended to prevent water leaks. • Approvals: IPX6 FRANÇAIS Veuillez lire et conserver toutes les instructions de sécurité et d’utilisation. Pour plus d’informations, rendez-vous à l’adresse hunterindustries.com/BTT. Instructions de sécurité importantes 1. N’utilisez que les accessoires indiqués par le fabricant. 2. Si nécessaire, utilisez un purgeur pour empêcher tout refoulement vers l’alimentation en eau. 3. Lorsque cela est demandé, utilisez un régulateur de pression pour contrôler le débit de l’eau. (Modèle PRLG203FH3MH pour (1,4 bar/138 kPa), PRLG253FH3MH pour (1,7 bar/172 kPa), PRLG303FH3MH pour (2 bar/207 kPa), PRLG403FH3MH pour (2,8 bar/276 kPa)) Conexión al suministro de agua Instrucciones para BTT-101/201: 1. Conecte el programador solamente a una toma de agua estándar con rosca para manguera de ¾" (19 mm). Desenrosque el adaptador gris para usar la opción de toma BSP de 1" (25 mm). 2. Apriete manualmente hasta ajustar. 3. Conecte una manguera de ¾" (19 mm), el adaptador de goteo (n.º BTT-LOC) o el adaptador rápido (incluido) a la salida BTT. 4. Apriete manualmente hasta ajustar. Descargue la aplicación para móvil 1. Descargue la aplicación gratuita Hunter BTT a un smartphone en la App Store para dispositivos iOS® o en Google Play™ Store dispositivos Android™. 2. Colóquese a menos de 32' (10 m) del programador. 3. Active el Bluetooth en el smartphone. 4. Presione el botón BUSCAR y seleccione el dispositivo Hunter BTT. DEUTSCH Lesen Sie die Sicherheits- und Gebrauchsanweisungen und bewahren Sie diese auf. Weitere Informationen finden Sie auf hunterindustries.com/BTT. Wichtige Sicherheitshinweise 1. Verwenden Sie ausschließlich Erweiterungen/Zubehörteile, die den Angaben des Herstellers entsprechen. 2. Für den Schutz des Trinkwassers vor Rückfließen sind geeignete Sicherungsarmaturen vorgeschrieben. 3. Wenn erforderlich, kann der Wasserdurchsatz mit einem Druckregler reguliert werden. (Modellnr. PRLG203FH3MH für (1,4 Bar/138 kPa), PRLG253FH3MH für (1,7 Bar/ 172 kPa), PRLG303FH3MH für (2 Bar/207 kPa), PRLG403FH3MH für (2,8 Bar/276 kPa)) Warnhinweise und Vorsichtsmaßnahmen • Nehmen Sie KEINE unerlaubten Veränderungen an diesem Produkt vor. • Halten Sie das Produkt von Feuer und Hitzequellen fern. • Setzen Sie Geräte mit Batterien keiner starken Hitze aus (z. B. durch Lagerung in direktem Sonnenlicht, Feuer, o.ä.). • Die Produktkennzeichnung befindet sich auf der Rückseite. • Batterien nur mit demselben oder einem gleichwertigen Batterietyp tauschen. Leere Batterien bitte gemäß den Bestimmungen entsorgen. • Verwenden Sie nicht gleichzeitig alte und neue Batterien bzw. Batterien unterschiedlichen Typs oder Fabrikats. Anklemmen der Batterien 1. Drücken S…

Text truncated - open the document above for the full version.

Users Manual

BATTERY-POWERED CONTROLLERS Visit hunterindustries.com RESIDENTIAL & COMMERCIAL IRRIGATION | Built on Innovation ® 117 BT T-10 0 Inlet diameter: 3/4" Outlet diameter: 3/4" Height: 5" Width: 4 9/ 10" Depth: 2 2/ 5" BT T-20 0 Inlet diameter: 3/4" Outlet diameter: 3/4" Height: 6 1/ 5" Width: 5 3/ 10" Depth: 3" BTT-LOC (optional) Inlet diameter: 3/4" Outlet diameter: 16-18 mm dripline Height: 23/4" Width: 11/4" Pressure Regulator (optional) Inlet diameter: 3/4" Outlet diameter: 3/4" Height: 3" Width: 1 1/ 2" KEY BENEFITS • Number of zones: - 1 or 2 • Battery-operated tap timer with Bluetooth ® control • 1 smartphone manages an unlimited number of controllers • 1-second to 24-hour run time with 4 start times for maximum programming flexibility • Cycling mode repeats continuously within user-defined water windows, perfect for drip systems or germinating seeds • Suspend irrigation up to 99 days during the off-season, perfect for seasonal markets • Manual push-button operation for quick operation without a smartphone • Automatic water shutoff after 1 hour prevents water waste • Blinking LED low-battery alert indicates battery replacement • Secure passcode protection prevents unauthorized schedule changes • Alkaline batteries included for quicker installation OPERATING SPECIFICATIONS • Two 1.5V AA alkaline batteries (included) • BTT-100 flow rate: 5 to 17 GPM (60 to 1,000 GPH) • BTT-200 flow rate: 4 to 15 GPM (48 to 900 GPH) • Recommended pressure: 7 to 116 PSI • Approvals: Plastic IPX6, Bluetooth 4.2 BLE, UL, cUL, FCC, CE, RCM • Warranty period: 2 years APP SPECIFICATIONS • iOS ® 9.0 or above • Android ™ 4.4 or above • Maximum communication distance: 32' BTT BTT ModelDescription BTT-1001-zone Bluetooth Tap Timer, 3/4" hose thread BTT-2002-zone Bluetooth Tap Timer, 3/4" hose thread BTT-LOCBTT adapter for 16-18 mm dripline PRESSURE REGULATOR ModelDescription PRLG203FH3MH20 PSI pressure regulator, ¾" hose thread PRLG253FH3MH25 PSI pressure regulator, ¾" hose thread PRLG303FH3MH30 PSI pressure regulator, ¾" hose thread PRLG403FH3MH40 PSI pressure regulator, ¾" hose thread Take advantage of smartphone-controlled, above-ground irrigation for easier access to the hose tap. The Bluetooth ® word mark and logos are registered trademarks owned by Bluetooth SIG Inc. and any use of such marks by Hunter Industries is under license. iOS is a trademark or registered trademark of Cisco in the U.S. and other countries and is used under license. Android is a trademark of Google LLC. V BTT Table of Contents: BTT Cross References: BTT

Cover Letter(s)

Page 1 of 1 December 15, 2020 RE: Explanation of BTT1 Model Similarities Model numbers covered by this letter: BTT-100 is identical to BTT-101 except for the thread type employed, as shown in the table below. As products are identical in every other way, all testing un-related to the thread type conducted on one model is representative of the other. Please contact me with any questions. Best Regards, Satoshi Kuwahara, Director Product Integrity Hunter Industries, Inc. [email protected] Brand Model Number Hunter BTT-100, BTT-101 Model Thread Type BTT-100 NPT BTT-101 BSP HUNTER INDUSTRIES 1940 Diamond Street San Marcos, CA 92078 1 760-744-5240 Main 1 800-733-2823 Support 1 760-744-7461 Fax hunterindustries.com

Cover Letter(s)

November 30, 2020 UL Verification Services Inc. 47173 Benicia Street Fremont, CA 94538, USA To whom it may concern: I, the undersigned, hereby authorize UL Verification Services Inc. to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by UL Verification Services Inc. on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing UL Verification Services Inc. as our representative, we still recognize that we are responsible to: a) fulfill the requirements for the scope of certification requested, including implementing any appropriate changes requested by UL Verification Services Telecommunications Certification Body (TCB) and / or the FCC; b) supply any and all information needed for the evaluation of the products for which certification is sought; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) not use our product certification in such a manner as to bring the TCB or FCC into disrepute and to not make any statement regarding product certification which the TCB or FCC may consider misleading or unauthorized; e) discontinue use of all advertising matter that contains any reference thereto and complies with any and all actions required by the FCC upon suspension or cancellation of certification; f) use certification only to indicate that products are certified in conformity with specified standards; g) endeavor to ensure that no certificate or report or any part thereof is used in a misleading manner, and any copies of the grants/certificates shall be reproduced in their entirety; h) comply with the requirements of the TCB and FCC, including the use of marks and label information prescribed for the scope of certification, when making reference to product certification in communication media such as documents, brochure or advertisements; HUNTER INDUSTRIES 1940 Diamond Street San Marcos, CA 92078 1 760-744-5240 Main 1 800-733-2823 Support 1 760-744-7461 Fax hunterindustries.com i) comply with the requirements for certification, supply any information needed for evaluation of products to be certified and, where applicable, make provision for the participation of observers; j) ensure that products marketed under the scope of the requested certification continue to comply with the certification requirements; k) provide a sample of a production unit for testing within 30 days of the request should this product be selected as part of either the TCB’s or the FCC’s market surveillance requirements; l) keep a record of all complaints relating to product’s compliance with requirements of relevant standard; make records available to UL or FCC when requested; take appropriate action with respect to such complaints and any deficiencies found in the product that affect compliance with requirements for certification; document the actions taken with respect to complaints and/or deficiencies; m) inform the TCB immediately of any changes that may affect its ability to comply with the certification requirements. This authorization is valid until further written notice from the applicant. Sincerely Yours, Satoshi Kuwahara, Director Product Integrity Hunter Industries, Inc.

Cover Letter(s)

December 07, 2020 Attn: FCC Office of Engineering and Technology / UL Verification Services TCB Subject: Request for Confidentiality FCC ID: M3UBTT1 To Whom It May Concern: Pursuant to the provisions of Sections 0.457 and 0.459 of the Commission’s rules (47 CFR §§ 0.457, 0.459), we are requesting the Commission to withhold the following attachments as confidential document from public disclosure indefinitely. • Schematic Diagram • Block Diagram • Theory of Operation • Antenna Specification Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant short-term confidentiality request on the following attachments until 180 days after the grant date: • External Photos • Internal Photos • Test Setup Photos • User Manual It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Best Regards Satoshi Kuwahara, Director Product Integrity Hunter Industries, Inc HUNTER INDUSTRIES 1940 Diamond Street San Marcos, CA 92078 1 760-744-5240 Main 1 800-733-2823 Support 1 760-744-7461 Fax hunterindustries.com

External Photos

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. Page: 1 of 4 Page 1 of 4 External Photos Applicant: Ningbo Yilin Aguatech Co., ltd. Address of Applicant: NO. 158, Duantang West Road, Ningbo China Equipment Under Test (EUT): Product Name: Water Timer Model No.: BTT-10X SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. Page: 2 of 4 Page 2 of 4 SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. Page: 3 of 4 Page 3 of 4 SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. Page: 4 of 4 Page 4 of 4 End

ID Label/Location Info

Hunter Industries, Inc. Rev. 1 12/9/2020 BTT10x Labels BTT 10x with label location

ID Label/Location Info

FCC ID: M3UBTT1 IC ID: 2772A-BTT1

ID Label/Location Info

FCC ID: M3UBTT1 IC ID: 2772A-BTT1

Internal Photos

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. Page: 3 of 5 Page 3 of 5

Internal Photos

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. Page: 1 of 5 Page 1 of 5 Internal Photos Applicant: Ningbo Yilin Aguatech Co., ltd. Address of Applicant: NO. 158, Duantang West Road, Ningbo China Equipment Under Test (EUT): Product Name: Water Timer Model No.: BTT-10X SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. Page: 2 of 5 Page 2 of 5 SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. Page: 3 of 5 Page 3 of 5 SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. Page: 4 of 5 Page 4 of 5 SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. Page: 5 of 5 Page 5 of 5 End

RF Exposure Info

NVLAP LAB CODE 200246-0 FCC Part 1 Subpart I FCC Part 2 Subpart J RSS 102 ISSUE 5 RF EXPOSURE REPORT FOR BLUETOOTH TAP TIMER MODEL NUMBER: BT-100/101 FCC ID: M3UBTT1 IC: 2772A-BTT1 REPORT NUMBER: R13156676-E1 ISSUE DATE: 2020-11-06 Prepared for HUNTER INDUSTRIES 1940 DIAMOND STREET SAN MARCOS, CA 92078-5120, USA Prepared by UL LLC 12 LABORATORY DR. RESEARCH TRIANGLE PARK, NC 27709 USA TEL: (919) 549-1400 REPORT NO: R13156676-E1 DATE: 2020-11-06 FCC ID: M3UBTT1 IC: 2772A-BTT1 Page 2 of 10 UL LLC FORM NO: 03-EM-F00858 12 Laboratory Dr., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. REVISION HISTORY Ver. Issue Date Revisions Revised By 1 2020-11-06 Initial Issue Brian T. Kiewra REPORT NO: R13156676-E1 DATE: 2020-11-06 FCC ID: M3UBTT1 IC: 2772A-BTT1 Page 3 of 10 UL LLC FORM NO: 03-EM-F00858 12 Laboratory Dr., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. TABLE OF CONTENTS REVISION HISTORY ..................................................................................................................2 TABLE OF CONTENTS .............................................................................................................3 1. ATTESTATION OF TEST RESULTS ..................................................................................4 2. TEST METHODOLOGY ......................................................................................................5 3. REFERENCES ....................................................................................................................5 4. FACILITIES AND ACCREDITATION ..................................................................................5 5. DECISION RULES AND MEASUREMENT UNCERTAINTY ...............................................5 5.1. METROLOGICAL TRACEABILITY ...............................................................................5 5.2. DECISION RULES ........................................................................................................5 6. MAXIMUM PERMISSIBLE EXPOSURE (LIMITS AND EQUATIONS) ................................6 6.1. FCC RULES .................................................................................................................6 6.2. ISED RULES ................................................................................................................7 6.3. EQUATIONS .................................................................................................................8 7. RF EXPOSURE RESULTS ................................................................................................10 END OF TEST REPORT ..........................................................................................................10 REPORT NO: R13156676-E1 DATE: 2020-11-06 FCC ID: M3UBTT1 IC: 2772A-BTT1 Page 4 of 10 UL LLC FORM NO: 03-EM-F00858 12 Laboratory Dr., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. 1. ATTESTATION OF TEST RESULTS COMPANY NAME: Hunter Industries 1940 Diamond Street San Marcos, CA 92078-5120, USA EUT DESCRIPTION: Bluetooth Tap Timer MODEL: BT-100/101 SERIAL NUMBER: Non-Serialized APPLICABLE STANDARDS STANDARD TEST RESULTS FCC PART 1 SUBPART I & PART 2 SUBPART J Complies RSS 102 ISSUE 5 Complies UL LLC. tested the above equipment in accordance with the requirements set forth in the above standards. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. All samples tested were in good operating condition throughout the entire test program. Measurement Uncertainties are published for informational purposes only and were not taken into account unless noted otherwise. This document may not be altered or revised in any way unless done so by UL LLC. and all revisions are duly noted in the revisions section. Any alteration of this document not carried out by UL LLC. will constitute fraud and shall nullify the document. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. government. Approved & Released For UL LLC By: Prepared By: Jeffrey Moser Brian T. Kiewra Operations Manager Project Engineer Consumer Technology Division Consumer Technology Division UL LLC UL LLC REPORT NO: R13156676-E1 DATE: 2020-11-06 FCC ID: M3UBTT1 IC: 2772A-BTT1 Page 5 of 10 UL LLC FORM NO: 03-EM-F00858 12 Laboratory Dr., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. 2. TEST METHODOLOGY All calculations were made in accordance with FCC Parts 1.1310, 2.1091, 2.1093, KDB 447498 D01 v06, KDB 447498 D03 V01, IEEE Std C95.1-2005, IEEE Std C95.3-2002, IC Safety Code 6 and RSS 102 Issue 5. 3. REFERENCES All measurements were made as documented in test report UL LLC Document R13156676-E2 for operation in the 2.4 GHz band. Output power, Duty cycle and Antenna gain data is excerpted from product documentation provided by the applicant. 4. FACILITIES AND ACCREDITATION The test sites and measurement facilities used to collect data are located at 12 Laboratory Dr., Research Triangle Park, NC 27709, USA and 2800 Perimeter Park Dr., Suite B, Morrisville, NC 27560, USA. UL LLC (RTP) is accredited by NVLAP, Laboratory Code 200246-0. 5. DECISION RULES AND MEASUREMENT UNCERTAINTY 5.1. METROLOGICAL TRACEABILITY All test and measuring equipment utilized to perform the tests documented in this report are calibrated on a regular …

Text truncated - open the document above for the full version.

Test Report

NVLAP Lab code: 200246-0 TEST REPORT Report Number. : R13156676-E2 Applicant : Hunter Industries 1940 Diamond Street San Marcos, CA 92078-5120 USA Model : BTT-100 / BTT-101 FCC ID : M3UBTT1 IC : 2772A-BTT1 EUT Description : Bluetooth Tap Timer Test Standard(s) : FCC 47 CFR PART 15 SUBPART C ISED RSS-247 ISSUE 2 ISED RSS-GEN ISSUE 5 + AMD 1 Date Of Issue: 2020-12-09 Prepared by: UL LLC 12 Laboratory Dr. Research Triangle Park, NC 27709 U.S.A. TEL: (919) 549-1400 REPORT NO: R13156676-E2 DATE: 2020-12-0 9 FCC ID: M3UBTT1 IC: 2772A-BTT1 Page 2 of 43 UL LLC 12 Laboratory Dr., RTP, NC 27709; USA TEL:(919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC REPORT REVISION HISTORY Rev. Issue Date Revisions Revised By 1 10/29/2020 Initial Issue Mike Antola 2 12/9/2020 Update to Sections 6.1, 9.4 and 9.5 Mike Antola REPORT NO: R13156676-E2 DATE: 2020-12-0 9 FCC ID: M3UBTT1 IC: 2772A-BTT1 Page 3 of 43 UL LLC 12 Laboratory Dr., RTP, NC 27709; USA TEL:(919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC TABLE OF CONTENTS REPORT REVISION HISTORY ..................................................................................................2 TABLE OF CONTENTS .............................................................................................................3 1. ATTESTATION OF TEST RESULTS ..................................................................................5 2. TEST RESULTS SUMMARY ...............................................................................................6 3. TEST METHODOLOGY ......................................................................................................7 4. FACILITIES AND ACCREDITATION ..................................................................................7 5. DECISION RULES AND MEASUREMENT UNCERTAINTY ...............................................8 5.1. METROLOGICAL TRACEABILITY ...............................................................................8 5.2. DECISION RULES ........................................................................................................8 5.3. MEASUREMENT UNCERTAINTY ................................................................................8 5.4. SAMPLE CALCULATION .............................................................................................8 6. EQUIPMENT UNDER TEST ................................................................................................9 6.1. EUT DESCRIPTION .....................................................................................................9 6.2. MAXIMUM OUTPUT POWER .......................................................................................9 6.3. DESCRIPTION OF AVAILABLE ANTENNAS ...............................................................9 6.4. SOFTWARE AND FIRMWARE .....................................................................................9 6.5. WORST-CASE CONFIGURATION AND MODE ...........................................................9 6.6. DESCRIPTION OF TEST SETUP ...............................................................................10 7. MEASUREMENT METHOD...............................................................................................11 8. TEST AND MEASUREMENT EQUIPMENT ......................................................................12 9. ANTENNA PORT TEST RESULTS ...................................................................................14 9.1. ON TIME AND DUTY CYCLE .....................................................................................14 9.2. 99% BANDWIDTH ......................................................................................................15 9.2.1. BLE (1Mbps) ........................................................................................................16 9.3. 6 dB BANDWIDTH ......................................................................................................17 9.3.1. BLE (1Mbps) ........................................................................................................18 9.4. OUTPUT POWER .......................................................................................................19 9.4.1. BLE (1Mbps) ........................................................................................................19 9.5. AVERAGE POWER ....................................................................................................20 9.5.1. BLE (1Mbps) ........................................................................................................20 9.6. POWER SPECTRAL DENSITY ..................................................................................21 9.6.1. BLE (1Mbps) ........................................................................................................22 REPORT NO: R13156676-E2 DATE: 2020-12-0 9 FCC ID: M3UBTT1 IC: 2772A-BTT1 Page 4 of 43 UL LLC 12 Laboratory Dr., RTP, NC 27709; USA TEL:(919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC 9.7. CONDUCTED SPURIOUS EMISSIONS .....................................................................23 9.7.1. BLE (1Mbps) ........................................................................................................24 10. RADIATED TEST RESULTS .........................................................................................25 10.1. LIMITS AND PROCEDURE.....................................................................................25 10.2. TRANSMITTER ABOVE 1 GHz ...............................................................................27 10.2.1. BLE (1Mbps) ....................................................................................................27 10.3. WORST CASE BELOW 30MHZ ..............................................................................37 10.4. WORST CASE BELOW 1 GHZ ................…

Text truncated - open the document above for the full version.

Test Setup Photos

NVLAP Lab code: 200246-0 PHOTOS EXHIBIT Report Number: R13156676-EP1 Applicant : Hunter Industries 1940 Diamond Street San Marcos, CA 92078-5120 USA Model : BTT-100/101 Contains FCC ID : M3UBTT1 Contains IC : 2772A-BTT1 EUT Description : Water Timer Test Standard(s) : FCC 47 CFR PART 15 SUBPART C ISED RSS-247 ISSUE 2 ISED RSS-GEN ISSUE 5 + AMD 1 Date Of Issue: 2020-11-06 Prepared by: UL LLC 12 Laboratory Dr. Research Triangle Park, NC 27709 U.S.A. TEL: (919) 549-1400 REPORT NO: R13156676-EP1 DATE: 2020-11-06 CONTAINS FCC ID: M3UBTT1 CONTAINS IC: 2772A-BTT1 Page 2 of 11 UL LLC 12 Laboratory Dr., RTP, NC 27709, USA TEL:(919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. REPORT REVISION HISTORY Rev. Issue Date Revisions Revised By 1 2020-11-06 Initial Issue Mike Antola REPORT NO: R13156676-EP1 DATE: 2020-11-06 CONTAINS FCC ID: M3UBTT1 CONTAINS IC: 2772A-BTT1 Page 3 of 11 UL LLC 12 Laboratory Dr., RTP, NC 27709, USA TEL:(919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. TABLE OF CONTENTS REPORT REVISION HISTORY ..................................................................................................2 TABLE OF CONTENTS .............................................................................................................3 1. SETUP DIAGRAMS ............................................................................................................4 2. SETUP PHOTOS .................................................................................................................5 REPORT NO: R13156676-EP1 DATE: 2020-11-06 CONTAINS FCC ID: M3UBTT1 CONTAINS IC: 2772A-BTT1 Page 4 of 11 UL LLC 12 Laboratory Dr., RTP, NC 27709, USA TEL:(919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. 1. SETUP DIAGRAMS EUT INTERFACE MODULE LAPTOP REPORT NO: R13156676-EP1 DATE: 2020-11…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Satoshi Kuwahara(Director, Product Integrity)
[email protected](760)304-7453Fax: 760-471-7599

Technical Contact

UL Verification ServicesSol Kuwatani
[email protected]5103194263

47173 Benicia Street · Fremont, California · United States

Test Firm

UL LLCSteven Thompson
[email protected]919 549 1430

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.30 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other transmitter. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Hunter Industries Inc

M3URMLR

Remote

May 21, 2026

Equipment Class

DTS - Digital Transmission System
LoRa Radio Module - FCC ID M3UA2CLORA - Hunter Industries Inc
M3UA2CLORA

LoRa Radio Module

Apr 28, 2026

Equipment Class

DTS - Digital Transmission System
Wireless Valve Link - FCC ID M3U-WVL - Hunter Industries Inc
M3U-WVL

Wireless Valve Link

Aug 18, 2024

Equipment Class

DTS - Digital Transmission System
Quick plug-in controller - FCC ID M3U-WVOM - Hunter Industries Inc
M3U-WVOM

Quick plug-in controller

Aug 18, 2024

Equipment Class

DTS - Digital Transmission System
Repeater - FCC ID M3U-RPT - Hunter Industries Inc
M3U-RPT

Repeater

Aug 06, 2024

Equipment Class

DTS - Digital Transmission System