
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Page 1 Part Number: 3E2513 | EdiƟ on 10 November 2012 ATTENTION: This equipment contains components that can be damaged by electrostaƟ c discharge. Ensure both you and the equipment are earthed before beginning any servicing. The Gallagher T11 Reader The Gallagher T11 Reader is a smart card proximity reader. It can be installed as either an entry reader or exit reader. It can be mounted on a verƟ cal, rectangular 50 mm x 75 mm (2” x 3”) fl ush box with mounƟ ng holes spaced at a nominal 85 mm (3.25”). The Mifare reader reads: Mifare DESFire EV1, Mifare Plus and Mifare Classic cards. The MulƟ Tech reader reads: Mifare DESFire EV1, Mifare Plus, Mifare Classic and 125 kHz cards. The reader sends informaƟ on to the Gallagher Controller and acts upon informaƟ on sent from the Gallagher Controller. The reader itself does not make any access decisions. The Gallagher T11 Reader uses the “Cardax IV Reader” communicaƟ ons protocol to communicate with the Gallagher Controller. Note: A French translaƟ on of this document can be downloaded from the Gallagher Support Site: hƩ p://support.gallagher.co IMPORTANT: Gallagher T11 MulƟ Tech readers only: Using dual technology 125/Mifare cards with Gallagher T11 MulƟ Tech readers may cause both card technologies to be read, resulƟ ng in double card badges and unusual reader feedback. Gallagher strongly recommends against using dual technology 125/Mifare cards with Gallagher MulƟ Tech readers for sites running pre-Command Centre v7.00 soŌ ware (due for release 2nd half, 2011). From Command Centre v7.00, a site may specify which technology a MulƟ Tech reader should read off a dual technology card. InstallaƟ on Note Gallagher T11 Reader Page 2 Gallagher T11 Reader EdiƟ on 10 | Part Number: 3E2513 November 2012 InstallaƟ on Note Before you begin Shipment Contents Check the shipment contains the following items: • 1 x Gallagher T11 Reader facia assembly • 1 x Gallagher T11 Reader base • 1 x M3 Torx Post Security screw • 2 x 6-32 UNC Phillips drive fi xing screws • 4 x 25 mm No.6 self tapping, pan head, Phillips drive fi xing screws • 4 x 40 mm No.6 self tapping, pan head, Phillips drive fi xing screws Power Supply The Gallagher T11 Reader is designed to operate over a supply voltage range of 9 - 16 Vdc measured at the reader terminals. The operaƟ ng current draw is dependant on the supply voltage at the reader. For the Mifare reader at 12 Vdc the current draw is 90 mA (standby). During card read, beeper and LED acƟ vity, the current will momentarily reach 125 mA (peak). For the MulƟ Tech reader at 12 Vdc the current draw is 90 mA (standby) and will momentarily reach 140 mA (peak). The power source should be linear or a good quality switched-mode power supply. The performance of the reader may be aff ected by a low quality, noisy power supply. Cabling The Gallagher T11 Reader requires a minimum cable size of 4 core 24 AWG (0.2 mm 2 ) stranded security cable. This cable allows the transmission of data (2 wires) and power (2 wires). When using a single cable to carry both power supply and data, both the power supply voltage drop and data requirements must be considered. Although the reader is specifi ed to operate at 9 Vdc, for good engineering design it is recommended that the voltage at the reader should be approximately 12 Vdc. Examples of approved cables for connecƟ ng a single Gallagher T11 Reader to a Controller and power supply, showing maximum cable lengths for each type of cable and the associated circuits are: Manufacturer referenceCable format* Combined power and data in a single cable Data only in a single cable CAT5E4 twisted pair Each 2 x 0.2 mm 2 (24 AWG) 100 m (330 Ō )300 m (1000 Ō ) SEC4724 x 0.2 mm 2 Not twisted pairs (24 AWG) 100 m (330 Ō )250 m (800 Ō ) SEC41424 x 0.4 mm 2 Not twisted pairs (21 AWG) 150 m (500 Ō )150 m (500 Ō ) BELDEN 87232 twisted pair Each 2 x 0.4 mm 2 (22 AWG) 100 m (330 Ō )150 m (500 Ō ) BELDEN 98422 twisted pair Each 2 x 0.2 mm 2 (24 AWG) 100 m (330 Ō )200 m (650 Ō ) Page 3 Gallagher T11 Reader InstallaƟ on Note Part Number: 3E2513 | EdiƟ on 10 November 2012 * The matching of wire sizes to equivalent wire gauges are only approximate. Grounding shielded cable may reduce the obtainable cable length by 25% to 30%. Distance between Proximity Readers The distance separaƟ ng any two proximity readers must not be less than 200 mm (8 inches) in all direcƟ ons. 200 mm When mounƟ ng a proximity reader on an internal wall, check that any reader fi xed to the other side of the wall is not less than 200 mm (8 inches) away. 200 mm InstallaƟ on The Gallagher T11 Reader is designed to be mounted on verƟ cally orientated electrical fl ush (gang) boxes, or any solid fl at surface. However installaƟ on on metal surfaces, parƟ cularly those with a large surface area will reduce read range. The extent to which the range is reduced will depend upon the type of metal used. The recommended mounƟ ng height for the reader is 1.1 m (3.6 Ō ) from the fl oor level to the centre of the reader device. However this may vary in some countries and you should check local regulaƟ ons for variaƟ ons to this height. 1. Ensure the building cable has been run out through the fl ush box. If you are not mounƟ ng to a fl ush box, use the drill template at the back of this installaƟ on note as a guide, to drill all fi ve holes. Drill the 13 mm (1/2 inch) diameter centre hole (this is the centre hole for which the building cable will exit the mounƟ ng surface) and the four fi xing holes. 2. Run the building cabling through the reader base. 3. Secure the base to the fl ush box using the two 6-32 UNC screws provided. It is important the base of the reader is fl ush with and Ɵ ght against the mounƟ ng surface. Page 4 Gallagher T11 Reader EdiƟ on 10 | Part Number: 3E2513 November 2012 InstallaƟ on Note If you are not mounƟ ng to a fl ush box, secure the base to the mounƟ ng surface using the four fi xing screws provided. Base 6-32 UNC screw Building cable 6-32 UNC screw 4.…
Text truncated - open the document above for the full version.
Page 1 Part Number: 3E2512 | EdiƟ on 11 November 2012 The Gallagher T12 Reader The Gallagher T12 Reader is a smart card proximity reader. It can be installed as either an entry reader or exit reader. It can be mounted on a BS 4662 BriƟ sh Standard square fl ush box. The Mifare reader reads: Mifare DESFire EV1, Mifare Plus and Mifare Classic cards. The MulƟ Tech reader reads: Mifare DESFire EV1, Mifare Plus, Mifare Classic and 125 kHz cards. The reader sends informaƟ on to the Gallagher Controller and acts upon informaƟ on sent from the Gallagher Controller. The reader itself does not make any access decisions. The Gallagher T12 Reader uses the “Cardax IV Reader” communicaƟ ons protocol to communicate with the Gallagher Controller. Note: A French translaƟ on of this document can be downloaded from the Gallagher Support Site: hƩ p://support.gallagher.co IMPORTANT: Gallagher T12 MulƟ Tech readers only: Using dual technology 125/Mifare cards with Gallagher T12 MulƟ Tech readers may cause both card technologies to be read, resulƟ ng in double card badges and unusual reader feedback. Gallagher strongly recommends against using dual technology 125/Mifare cards with Gallagher MulƟ Tech readers for sites running pre-Command Centre v7.00 soŌ ware (due for release 2nd half, 2011). From Command Centre v7.00, a site may specify which technology a MulƟ Tech reader should read off a dual technology card. InstallaƟ on Note Gallagher T12 Reader ATTENTION: This equipment contains components that can be damaged by electrostaƟ c discharge. Ensure both you and the equipment are earthed before beginning any servicing. Page 2 Gallagher T12 Reader EdiƟ on 11 | Part Number: 3E2512 November 2012 InstallaƟ on Note Before you begin Shipment Contents Check the shipment contains the following items: • 1 x Gallagher T12 Reader facia assembly • 1 x Gallagher T12 Reader base • 1 x M3 Torx Post Security screw • 2 x M3.5 Phillips drive fi xing screws • 4 x 25 mm No.6 self tapping, pan head, Phillips drive fi xing screws • 4 x 40 mm No.6 self tapping, pan head, Phillips drive fi xing screws Power Supply The Gallagher T12 Reader is designed to operate over a supply voltage range of 9 - 16 Vdc measured at the reader terminals. The operaƟ ng current draw is dependant on the supply voltage at the reader. For the Mifare reader at 12 Vdc the current draw is 90 mA (standby). During card read, beeper and LED acƟ vity, the current will momentarily reach 125 mA (peak). For the MulƟ Tech reader at 12 Vdc the current draw is 90 mA (standby) and will momentarily reach 140 mA (peak). The power source should be linear or a good quality switched-mode power supply. The performance of the reader may be aff ected by a low quality, noisy power supply. Cabling The Gallagher T12 Reader requires a minimum cable size of 4 core 24 AWG (0.2 mm 2 ) stranded security cable. This cable allows the transmission of data (2 wires) and power (2 wires). When using a single cable to carry both power supply and data, both the power supply voltage drop and data requirements must be considered. Although the reader is specifi ed to operate at 9 Vdc, for good engineering design it is recommended that the voltage at the reader should be approximately 12 Vdc. Examples of approved cables for connecƟ ng a single Gallagher T12 Reader to a Controller and power supply, showing maximum cable lengths for each type of cable and the associated circuits are: Manufacturer referenceCable format* Combined power and data in a single cable Data only in a single cable CAT5E4 twisted pair Each 2 x 0.2 mm 2 (24 AWG) 100 m (330 Ō )300 m (1000 Ō ) SEC4724 x 0.2 mm 2 Not twisted pairs (24 AWG) 100 m (330 Ō )250 m (800 Ō ) SEC41424 x 0.4 mm 2 Not twisted pairs (21 AWG) 150 m (500 Ō )150 m (500 Ō ) BELDEN 87232 twisted pair Each 2 x 0.4 mm 2 (22 AWG) 100 m (330 Ō )150 m (500 Ō ) BELDEN 98422 twisted pair Each 2 x 0.2 mm 2 (24 AWG) 100 m (330 Ō )200 m (650 Ō ) Page 3 Gallagher T12 Reader InstallaƟ on Note Part Number: 3E2512 | EdiƟ on 11 November 2012 * The matching of wire sizes to equivalent wire gauges are only approximate. Grounding shielded cable may reduce the obtainable cable length by 25% to 30%. Distance between Proximity Readers The distance separaƟ ng any two proximity readers must not be less than 200 mm (8 inches) in all direcƟ ons. 200 mm When mounƟ ng a proximity reader on an internal wall, check that any reader fi xed to the other side of the wall is not less than 200 mm (8 inches) away. 200 mm InstallaƟ on The Gallagher T12 Reader is designed to be mounted on a standard BriƟ sh electrical fl ush box, or any solid fl at surface. However installaƟ on on metal surfaces, parƟ cularly those with a large surface area will reduce read range. The extent to which the range is reduced will depend upon the type of metal used. The recommended mounƟ ng height for the reader is 1.1 m (3.6 Ō ) from the fl oor level to the centre of the reader device. However this may vary in some countries and you should check local regulaƟ ons for variaƟ ons to this height. 1. Ensure the building cable has been run out through the fl ush box. If you are not mounƟ ng to a fl ush box, use the drill template at the back of this installaƟ on note as a guide, to drill all fi ve holes. Drill the 13 mm (1/2 inch) diameter centre hole (this is the centre hole for which the building cable will exit the mounƟ ng surface) and the four fi xing holes. 2. Run the building cabling through the reader base. 3. Secure the base to the fl ush box using the two M3.5 screws provided. It is important the base of the reader is fl ush with and Ɵ ght against the mounƟ ng surface. Page 4 Gallagher T12 Reader EdiƟ on 11 | Part Number: 3E2512 November 2012 InstallaƟ on Note If you are not mounƟ ng to a fl ush box, secure the base to the mounƟ ng surface using the four fi xing screws provided. Base Building cable M3.5 screw M3.5 screw 4. Connect the reader tail extending from the facia assembly to the building cable. Connect the wi…
Text truncated - open the document above for the full version.
Gallagher Group Ltd 181 Kahikatea Drive Private Bag 3026 Hamilton, New Zealand Tel: +64-7-838-9800 Fax: +64-7-838-9801 Email: [email protected] www.gallaghergroup.co.nz Companies Gallagher Group Ltd – NZ Sunplas Engineering (82) Ltd – NZ Gallagher Security (int) Ltd – NZ Gallagher Power Fence (SA) Pty – Sth Africa Gallagher Security (UK) Ltd – UK Gallagher Security (USA) Inc – USA Franklin Machinery – New Zealand PEC Pumps PEC Fuel Pumps Ltd Cardax (International) Ltd Gallagher Finance & Management Ltd Gallagher IT Solutions Ltd Reach Global Ltd Associate Companies Gallagher Europe Veldman & Djikstra Gallagher Australia Pty Ltd – Australia Gallagher Insultimber – Australia Gallagher Power Fence Inc – USA Gallagher Power Fencing Systems Inc – Canada Gallagher Power Fence (IRL) Ltd – Ireland Ibex Gallagher – India A/S Poda Hegn – Denmark NZ Producciones S.A – Argentina International Scales Pty Ltd - Australia August 12, 2010 To Whom It May Concern: I hereby appoint Menardo Lazaro to sign letters and applications for any filings with regulatory agencies on our behalf, and to receive and exchange data between our company, the agents company and the agency in connection with certification for any products that our company owns or manufactures. Sincerely, Tony Smith Technical Development Manager Gallagher Group Ltd.
GALLAGHER GROUP LIMITED 181 Kahikatea Drive, Hamilton 3206, New Zealand. Private Bag 3026, Hamilton 3240, New Zealand. TEL +64 7 838 9800 FAX +64 7 838 9801 EMAIL [email protected] www.gallagher.co Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 October 16, 2012 TO WHOM IT MAY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, Gallagher Group Ltd requests confidentiality for the following products: FCC ID Number Product Title/Model M5VC30044X T11 Multi Tech Reader and T12 Multi Tech Reader For the product stated above, we request that the following information be held confidential: 1) Electrical Schematics of the Circuitry 2) Block Diagram 3) Operational Description No other items submitted as part of the equipment authorization filing process are deemed confidential. The above exhibits contain Gallagher Group Ltd trade secrets and proprietary information that could be of benefit to our competitors regarding the design of our Prox Readers. This material is not customarily available to the general public and we request that it be withheld from public inspection. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Menardo Lazaro Compliance Engineer
____________________________________________________________________________________________________________________________________________________________________________ Page 1 of 25 Test Report No 120712.1c 23rd November 2012 This report may not be reproduced except in full. EMC Technologies (NZ) Ltd PO Box 68-307 Newton, Auckland Phone 09 360 0862 Fax 09 360 0861 E-Mail Address: [email protected] Web Site: www.emctech.com.au TEST REPORT Gallagher T11 Multi-Tech Proximity Card Reader tested to 47 Code of Federal Regulations Part 15 - Radio Frequency Devices Subpart C – Intentional Radiators Section 15.225 Operation within the band 13.110 -14.010 MHz for Gallagher Group Ltd This Test Report is issued with the authority of: ________________________________________ Andrew Cutler- General Manager ____________________________________________________________________________________________________________________________________________________________________________ Page 2 of 25 Test Report No 120712.1c 23rd November 2012 This report may not be reproduced except in full. Table of Contents 1. STATEMENT OF COMPLIANCE 3 2. RESULTS SUMMARY 3 3. INTRODUCTION 4 4. CLIENT INFORMATION 4 5. DESCRIPTION OF TEST SAMPLE 4 6. SETUPS AND PROCEDURES 5 7. TEST EQUIPMENT USED 19 8. ACCREDITATIONS 19 9. PHOTOGRAPHS 20 ____________________________________________________________________________________________________________________________________________________________________________ Page 3 of 25 Test Report No 120712.1c 23rd November 2012 This report may not be reproduced except in full. 1. STATEMENT OF COMPLIANCE The Gallagher T11 Multi-Tech Proximity Card Reader complies with FCC Part 15 Subpart C Section 15.225 as an Intentional Radiator when the methods as described in ANSI C63.4 - 2003 are applied. 2. RESULTS SUMMARY The results from testing are summarised in the following table: Clause Parameter Result 15.201 Equipment authorisation requirement Certification required. 15.203 Antenna requirement Complies. Antennas internal to the device. 15.204 External PA and antenna modifications Not applicable. No external devices. 15.205 Restricted bands of operation Complies. Device transmits on 13.560 MHz with an occupied bandwidth of 442.5 kHz and it transmits on 125 kHz with an occupied bandwidth of 875 Hz 15.207 Conducted limits Complies. 15.209 Radiated emission limits - Emissions < 30 MHz Complies with a 32.7 dB margin at 125 kHz. 15.209 Radiated emission limits – Emissions > 30 MHz Complies with a 5.2 dB margin at 253.973 MHz (Horizontal). 15.225 Radiated emission limits - Fundamental Complies with a 46.8 dB margin at 13.560 MHz. 15.225 Frequency stability Complies ____________________________________________________________________________________________________________________________________________________________________________ Page 4 of 25 Test Report No 120712.1c 23rd November 2012 This report may not be reproduced except in full. 3. INTRODUCTION This report describes the tests and measurements performed for the purpose of determining compliance with the specification. The client selected the test sample. This report relates only to the sample tested. This report replaces report 120712.1b of 13 th November 2012 to further update the photographs and IDs. Measurement uncertainties with statistical confidence intervals of 95% are shown below test results. Both Class A and Class B uncertainties have been accounted for, as well as influence uncertainties where appropriate. 4. CLIENT INFORMATION Company Name Gallagher Group Ltd Address Kahikatea Drive City Hamilton Country New Zealand Contact Mr Brian Rose 5. DESCRIPTION OF TEST SAMPLE Brand Name Gallagher Model Number T11 Product Multi-Tech Proximity Card Reader Manufacturer Gallagher Group Ltd Country of Origin New Zealand Serial Number 1228107067 + 1226307275 FCC ID M5VC30044X IC ID 7369A-C30024X ____________________________________________________________________________________________________________________________________________________________________________ Page 5 of 25 Test Report No 120712.1c 23rd November 2012 This report may not be reproduced except in full. 6. SETUPS AND PROCEDURES Standard The sample was tested in accordance with 47 CFR Part 15 Subpart C. Methods and Procedures The measurement methods and procedures as described in ANSI C63.4 - 2003 were used. Section 15.201: Equipment authorisation requirement Certification as detailed in Subpart J of Part 2 is required for this device. Section 15.203: Antenna requirement This device has internal antennas for the 125 kHz and 13.560 MHz transmitters. Result: Complies. Section 15.204: External radio frequency power amplifiers and antenna modifications It is not possible to attach an external power amplifier to this transmitter. Result: Complies. ____________________________________________________________________________________________________________________________________________________________________________ Page 6 of 25 Test Report No 120712.1c 23rd November 2012 This report may not be reproduced except in full. Section 15.205: Restricted bands of operation The transmitter transmits on 125.000 kHz and 13.560 MHz. This device would therefore fall between the restricted bands of 90 – 110 kHz and 495 – 505 kHz into the band of 13.110 – 14.010 MHz that is covered by Section 15.225. 125 kHz modulation bandwidth = 875 Hz The plot below shows that the device has an occupied bandwidth of 1.082 MHz when measured using a resolution bandwidth of 50 kHz (1% of the 6 MHz span) and with a video bandwidth of 200 kHz that is approximately 3 times the resolution bandwidth. ____________________________________________________________________________________________________________________________________________________________________________ Page 7 of 25 Test Report No 120712.1c 23rd November 2012 This report may not be reproduced except in full. The 99% power bandwidth was then measured…
Text truncated - open the document above for the full version.
____________________________________________________________________________________________________________________________________________________________________________ Page 1 of 25 Test Report No 120712.1c 23rd November 2012 This report may not be reproduced except in full. EMC Technologies (NZ) Ltd PO Box 68-307 Newton, Auckland Phone 09 360 0862 Fax 09 360 0861 E-Mail Address: [email protected] Web Site: www.emctech.com.au TEST REPORT Gallagher T11 Multi-Tech Proximity Card Reader tested to 47 Code of Federal Regulations Part 15 - Radio Frequency Devices Subpart C – Intentional Radiators Section 15.225 Operation within the band 13.110 -14.010 MHz for Gallagher Group Ltd This Test Report is issued with the authority of: ________________________________________ Andrew Cutler- General Manager ____________________________________________________________________________________________________________________________________________________________________________ Page 2 of 25 Test Report No 120712.1c 23rd November 2012 This report may not be reproduced except in full. Table of Contents 1. STATEMENT OF COMPLIANCE 3 2. RESULTS SUMMARY 3 3. INTRODUCTION 4 4. CLIENT INFORMATION 4 5. DESCRIPTION OF TEST SAMPLE 4 6. SETUPS AND PROCEDURES 5 7. TEST EQUIPMENT USED 19 8. ACCREDITATIONS 19 9. PHOTOGRAPHS 20 ____________________________________________________________________________________________________________________________________________________________________________ Page 3 of 25 Test Report No 120712.1c 23rd November 2012 This report may not be reproduced except in full. 1. STATEMENT OF COMPLIANCE The Gallagher T11 Multi-Tech Proximity Card Reader complies with FCC Part 15 Subpart C Section 15.225 as an Intentional Radiator when the methods as described in ANSI C63.4 - 2003 are applied. 2. RESULTS SUMMARY The results from testing are summarised in the following table: Clause Parameter Result 15.201 Equipment authorisation requirement Certification required. 15.203 Antenna requirement Complies. Antennas internal to the device. 15.204 External PA and antenna modifications Not applicable. No external devices. 15.205 Restricted bands of operation Complies. Device transmits on 13.560 MHz with an occupied bandwidth of 442.5 kHz and it transmits on 125 kHz with an occupied bandwidth of 875 Hz 15.207 Conducted limits Complies. 15.209 Radiated emission limits - Emissions < 30 MHz Complies with a 32.7 dB margin at 125 kHz. 15.209 Radiated emission limits – Emissions > 30 MHz Complies with a 5.2 dB margin at 253.973 MHz (Horizontal). 15.225 Radiated emission limits - Fundamental Complies with a 46.8 dB margin at 13.560 MHz. 15.225 Frequency stability Complies ____________________________________________________________________________________________________________________________________________________________________________ Page 4 of 25 Test Report No 120712.1c 23rd November 2012 This report may not be reproduced except in full. 3. INTRODUCTION This report describes the tests and measurements performed for the purpose of determining compliance with the specification. The client selected the test sample. This report relates only to the sample tested. This report replaces report 120712.1b of 13 th November 2012 to further update the photographs and IDs. Measurement uncertainties with statistical confidence intervals of 95% are shown below test results. Both Class A and Class B uncertainties have been accounted for, as well as influence uncertainties where appropriate. 4. CLIENT INFORMATION Company Name Gallagher Group Ltd Address Kahikatea Drive City Hamilton Country New Zealand Contact Mr Brian Rose 5. DESCRIPTION OF TEST SAMPLE Brand Name Gallagher Model Number T11 Product Multi-Tech Proximity Card Reader Manufacturer Gallagher Group Ltd Country of Origin New Zealand Serial Number 1228107067 + 1226307275 FCC ID M5VC30044X IC ID 7369A-C30024X ____________________________________________________________________________________________________________________________________________________________________________ Page 5 of 25 Test Report No 120712.1c 23rd November 2012 This report may not be reproduced except in full. 6. SETUPS AND PROCEDURES Standard The sample was tested in accordance with 47 CFR Part 15 Subpart C. Methods and Procedures The measurement methods and procedures as described in ANSI C63.4 - 2003 were used. Section 15.201: Equipment authorisation requirement Certification as detailed in Subpart J of Part 2 is required for this device. Section 15.203: Antenna requirement This device has internal antennas for the 125 kHz and 13.560 MHz transmitters. Result: Complies. Section 15.204: External radio frequency power amplifiers and antenna modifications It is not possible to attach an external power amplifier to this transmitter. Result: Complies. ____________________________________________________________________________________________________________________________________________________________________________ Page 6 of 25 Test Report No 120712.1c 23rd November 2012 This report may not be reproduced except in full. Section 15.205: Restricted bands of operation The transmitter transmits on 125.000 kHz and 13.560 MHz. This device would therefore fall between the restricted bands of 90 – 110 kHz and 495 – 505 kHz into the band of 13.110 – 14.010 MHz that is covered by Section 15.225. 125 kHz modulation bandwidth = 875 Hz The plot below shows that the device has an occupied bandwidth of 1.082 MHz when measured using a resolution bandwidth of 50 kHz (1% of the 6 MHz span) and with a video bandwidth of 200 kHz that is approximately 3 times the resolution bandwidth. ____________________________________________________________________________________________________________________________________________________________________________ Page 7 of 25 Test Report No 120712.1c 23rd November 2012 This report may not be reproduced except in full. The 99% power bandwidth was then measured…
Text truncated - open the document above for the full version.
181 Kahikatea Drive · Melville · New Zealand
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 13.56 MHz - 13.56 MHz | - |

Handheld EID Tag Reader HR0
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Prox Readers T10 Mifare
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Prox Readers T15 Mifare
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Prox Readers T21 PIV
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Prox Readers T30
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified