FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Advantech Co Ltd/
  3. M82-POC127

M82-POC127Computer

Advantech Co Ltd
Computer - FCC ID M82-POC127 - Advantech Co Ltd
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Aug 09, 2015
Application Purpose
Original Equipment
Date of Application
Aug 06, 2015
Equipment Note
Computer
Frequency Range
5745.00000000 - 5825.00000000
Company
Advantech Co Ltd
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

POC127 Point of Care Terminal with Intel® Pineview-M N450 CPU and 12.1” VA LCD (Computer) The Instructions for the User The document combines text and illustrations, providing a comprehensive overview of the system. The information is presented as sequential steps of action, allowing the user to learn directly how to use the device. The text provides explanations and instructs the user step by- step in the practical use of the product, with short, clear instructions in easy-to-follow sequence. Definitions Warning! A WARNING statement provides important information about a poten-tially hazardous situation which, if not avoided, could result in death or serious injury. Caution! A CAUTION statement provides important information about a poten-tially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or in damage to the equipment or other property. Note! A NOTE provides additional information intended to avoid inconve-niences during operation. Safety Instructions 1. Strictly follow these Instructions for Use; please read these safety instructions carefully. 2. Please keep this User Manual for later reference; any use of the product requires full understanding and strict observation of all portions of these instruc-tions. Observe all WARNINGS and CAUTIONS as rendered throughout this manual and on labels on the equipment. 3. Repair of the device may only be carried out by trained service personnel. Advantech recommends that a service contract be obtained with Advantech Service and that all repairs also be carried out by them. Otherwise the correct functioning of the device may be compromised. Warning! Because of the danger of electric shock, never remove the cover of a device while it is in operation or connected to a power outlet. 4. If one of the following situations arises, have the equipment checked by service personnel: „ The power cord or plug isdmaged. „ Liquid has penetrated into the equipment. „ The equipment has been exposed to moisture. „ The equipment does not work well, or you cannot get it to work according to the user manual. „ The equipment has been dropped and damaged. „ The equipment has obvious signs of breakage. 5. Disconnect this equipment from any AC outlet before cleaning. Use a damp cloth. Do not use liquid or spray detergents for cleaning and keep this equip-ment away from humidity. Caution! To avoid short-circuiting and otherwise damaging the device, do not allow fluids to come in contact with the device. If fluids are accidentally spilled on the equipment, remove the affected unit from service as soon as possible and contact the service personnel to verify that patient safety is not compromised. 6. Put this equipment on a reliable surface during installation. Dropping it or letting it fall may cause damage. For plug-in equipment, the power outlet socket must be located near the equipment and must be easily accessible. Caution! To prevent overheating, do not cover the openings or place the device in direct sunlight or near radiant heaters. 7. Make sure the voltage of the power source is correct before connecting the equipment to the power outlet. Position the power cord so that people cannot step on it. Do not place anything over the power cord. If the equipment is not used for a long time, disconnect it from the power source to avoid damage by transient over voltage. Caution! Do not leave this equipment in an uncontrolled environment where the storage temperature is below -20° C (-4° F) or above 60° C (140° F). This may damage the equipment. 8. If your computer does not keep the correct time or the BIOS configuration has been reset to default, the battery may have no charge. Caution! Do not replace battery yourself. Please contact a qualified technician or your retailer. The computer is provided with a battery- powered, real-time clock circuit. There is a danger of explosion if battery is incorrectly replaced. Replace only with same or equivalent type recommended by the manufacturer. Discard used batteries according to the manufacturer’s instructions. Caution! The battery charging indicator is not included with this device. It will be added to the finished system assembly and be shown with the com- pleted system. 9. Improper installation of VESA mounting can result in serious personal injury! VESA mount installation should be operated by professional technician, please contact the service technician or your retailer if you need this service. The detail operating procedure is specified in Appendix A. 10. Classification: 1). Supply Class I s 2). No applied part 3). Continuous Operation 4). Not AP or APG category Warning! This device is not suitable for use in the presence of flammable anes-thetic mixture with air, oxygen, nitrous oxide, or for life support systems. 11. Environmental protection: follow national requirements to dispose of unit. 12. Maintenance: to properly maintain and clean the surfaces, use only the approved products or clean with a dry applicator. Caution! When servicing the device, always use replacement parts that are quali- fied to Advantech standards. Advantech Digital Healthcare cannot war- rant or endorse the safe performance of third-party replacement parts for use with our medical device. 13. Make sure the user does not allow contact between SIP/SOPs and the patient at the same time. 14. When networking with electrical devices, the operator is responsible for ensuring that the resulting system meets the requirements set forth by the following standards: – EN 60601-1 (IEC 60601-1) Medical electrical equipment Part 1: General requirements for safety – EN 60601-1-1 (IEC 60601-1-1) Medical electrical equipment Part 1-1: General requirements for safety Collateral standard: Safety requirements for Medical electrical systems – EN 60601-1-2 (IEC 60601-1-2) Medical electrical equipment Part 1-2: General requirements for safety Collateral standard: Electromagnetic compatibility; Requirements and test…

Text truncated - open the document above for the full version.

Cover Letter(s)

http:// www.smartant.com E-mail: [email protected] Embedded Antenna for 2400 – 2500 MHz & 5150 – 5875 MHz ADV05-22058B Electrical Specification Environmental & Mechanical Characteristics Aux. Antenna Frequency range 2400 MHz-2500 MHz 5150 MHz-5875 MHz Gain ≧-5 dBi VSWR 2.0 : 1 (max.) Power handling 2 W (cw) Impedance 50 Ohm Connector I-PEX Cable φ1.13 mm, Aux. antenna, Gary ,580 mm Temperature -10°C to +55°C Humidity 95% @ 55°C Weight 0.4 g Dimensions 31 x 22 x 4.5 mm Version 1 http:// www.smartant.com E-mail: [email protected] Product Drawing SmartAnt 2 0 ° ± 5 2.5±0.5 3 IPEX Cable Length is 580mm - Gray 1 Aux. Antenna 4 Double-Faced Tape 10*10mm 31±1 Double-Faced Tape Side 580±4 22±1 http:// www.smartant.com E-mail: [email protected] VSWR Aux. Antenna VSWR=2.0 VSWR=1.5 http:// www.smartant.com E-mail: [email protected] Material Approval - Reflector (1/1) http:// www.smartant.com E-mail: [email protected] Material Approval – Connector (1/1) http:// www.smartant.com E-mail: [email protected] Material Approval – Cable (1/1) http:// www.smartant.com E-mail: [email protected] Material Approval – Tape G4000 (1/2) http:// www.smartant.com E-mail: [email protected] Material Approval - Tape G4000 (2/2) http:// www.smartant.com E-mail: [email protected] Material Approval –PE Bag (1/1) http:// www.smartant.com E-mail: [email protected] Material Approval – CTN (1/2) http:// www.smartant.com E-mail: [email protected] Material Approval – CTN (2/2) 寰波科技股份有限公司 SmartAnt Telecom Co., Ltd Products Inspection Plan Form No.:P7-RD-011-020 Rev.:A 保存期限:至該產品量產停產後 1 年 Smartant P/N (型/料號): ADV05-22058B Inspection Date (日期): 04/10/2009 Doc No: PM09-034 Rev.: 1 Description(規格名稱): Assembly for ADV05-22058B Φ1.13 Gray Manufacturing (製造商) : N/A 1.Inspectiont Item : Dimension/Function (檢驗項目:尺寸/功能) Sample size(抽樣數): 1 Defect Inspection Record No CR MA MI Apparatus (檢驗儀器) Specification(規格)- Photo _1__ NO 1NO 2NO 3 NO 4NO 5 Judgment (判定) 1 580 ± 4 mm (576~584) 578 OK 2 31±1mm (30~32) 31.02 OK 1 V 游標卡尺/ 捲尺 3 22±1mm (21~23) 22.05 OK 2.Inspection Item : Appearance(檢驗項目:外觀) Apparatus : Visual (檢測 儀器:目視) Sample Size (抽樣數) : Defect Defect No CR MA MI Specification(規格)- Photo _2__ NG Q’ty No CR MAMI Specification(規格) - Photo ___ NG Q’ty 1 V 需與圖面吻合。 O 8 V 銅片/IPEX 表面允許刮傷、凹陷、 凸起、氧化。但手指紋不允許。 O 2 V 銅片表面不可有、剝落、龜裂、異色、 電鍍不良之現象。 O 9 V 目視不得有毛邊、毛邊須在 0.2mm 以下不允許,不得有傷人之毛邊。 O 3 V 不可有缺料、混料、錯料。 O 10 V IPEX Cable ---Gray O 4 V 不可外觀變形、成型不良。 O 11 V 銅片/IPEX 表面允許擦傷、磨傷。 O 5 V 外型尺寸不合規格。 O 12 V 銅片表面水紋痕、滴淚狀紋可允許。 O 6 V 銅片切斷面處允許生銹、銹斑、氧化。 O 14 V銅片表面不可有油漬、色漬、髒污。O 7 V 熱溶膠此為固定焊接點使用, 確定其 有無確實黏著於焊點。 O 15 V 銅片背面須貼付 Double-Faced Tape 10*10mm,但其外觀不作檢驗。 O 8 V 焊接處熱熔膠不列入外觀檢驗項目。 O 16 V包裝盒不作外觀檢驗。 O Description(說明): 1. 檢驗重點重要項目如上NO:1~16 。 點規卡依據中華民國品質學會發行版。(EFA QC-C0192). Photo_1_ Photo _2__ 1 First Issued(新建立) Rev Engineering Change Description Issue Approval Proposer: (申請人) Jimmy 04/09/’09 QA Approval: (QA核准) Clark 04/10’09 PM Approval: (PM核准) May 04/09/’09 Customer Confirmation: (客戶確認) Flow(作業流程): 1.申請人→QA檢驗判定核准→PM核淮→由PM編號及分發(放於網路上)歸檔 2.如需要客戶確認→提供給業務→客戶確認→PM分發(放於網路上)歸檔。 2 0 ° ± 5 2.5±0.5 3 IPEX Cable Length is 580mm - Gray 1 Aux. Antenna 4 Double-Faced Tape 10*10mm 31±1 Double-Faced Tape Side 580±4 22±1 熱熔膠不列入外觀檢驗 寰波科技股份有限公司 SmartAnt Telecom Co.,Ltd ADV05-22058B 2009/4/9 Environment-Related Substances Report SmartAnt P/N: Customer P/N: Ant 2.4/5G φ1.13 360/580MM(G)IPEX OF M1 Product Description: 寰波科技股份有限公司 SmartAnt Telecom Co.,Ltd. CdPbHgCr VIPBBs PBDEs Sheath / Gray N.DN.DN.DN.DN.DN.DCE/2007/A4663 Pass Sheath / Black N.DN.DN.DN.DN.DN.DCE/2008/B1636 Pass Outer Conductor N.DN.DN.DNegatuve--------CE/2008/B1640 Pass Insulation N.DN.DN.DN.DN.DN.DCE/2008/B1639 Pass Inner Conductor N.DN.DN.DNegatuve--------CE/2008/B1641 Pass Housing-Black N.D23N.DN.DN.DN.DCE/2008/31207 Pass Coetact N.D20N.DN.DN.DN.DCE/2008/31217 Pass Ground Contact N.D17N.DN.DN.DN.DCE/2008/31216 Pass 3 N.DN.DN.DNegatuveN.DN.DCE/2009/10355A Pass 4 N.D242N.DN.DN.DN.DCE/2008/32645 Pass 5 N.DN.DN.DN.DN.DN.DCE/2007/91193 Pass 裱面紙板 N.D20N.DN.DN.DN.D CE/2008/32428 Pass 瓦楞芯紙 N.D21N.DN.DN.DN.D CE/2008/32427 Pass 白膠 N.DN.DN.DN.DN.DN.D KE/2008/32592 CE/2008/22385 Pass 油墨 N.DN.DN.DN.DN.DN.D CE/2008/12889 CE/2008/77012 Pass 7 N.DN.DN.DN.DN.DN.DCE/2008/71425 Pass ND = Not Detected ; "---" = Not Conducted;Negative=Absence of Cr(VI)coating/surface layer PE Bag Packing PackingPacking Packing Carton & Box 6 Remarks: ENVIRONMENT-RELATED SUBSTANCES TO BE CONTROLLED-ADV05-22058B Ite m Pass / Fail Test Item(Cr6+,Hg,Pb,PBBs,PBBEs<1000ppm,Cd<100ppm) Report No. Double-Faced Tape SUS BEND PLANT I-PEX Connector 1 Antenna Components Ø1.13 Cable Black & Gray 2 Solder Wire

Cover Letter(s)

http:// www.smartant.com E-mail: [email protected] Embedded Antenna for 2400 – 2500 MHz & 5150 – 5875 MHz ADV05-22058A Electrical Specification Environmental & Mechanical Characteristics Main Antenna Frequency range 2400 MHz-2500 MHz 5150 MHz-5875 MHz Gain ≧-5 dBi VSWR 2.0 : 1 (max.) Power handling 2 W (cw) Impedance 50 Ohm Connector I-PEX Cable φ1.13 mm, Main antenna, Black ,360 mm Temperature -10°C to +55°C Humidity 95% @ 55°C Weight 0.3 g Dimensions 31 x 22 x 4.5 mm Version 1 http:// www.smartant.com E-mail: [email protected] Product Drawing SmartAnt 2 0 ° ± 5 2.5±0.5 2 IPEX Cable Length is 360mm - Black 1 Main antenna 4 Double-Faced Tape 10*10mm 31±1 360±4 Double-Faced Tape Side 22±1 http:// www.smartant.com E-mail: [email protected] VSWR Main Antenna VSWR=1.5 VSWR=2.0 http:// www.smartant.com E-mail: [email protected] Material Approval - Reflector (1/1) http:// www.smartant.com E-mail: [email protected] Material Approval – Connector (1/1) http:// www.smartant.com E-mail: [email protected] Material Approval – Cable (1/1) http:// www.smartant.com E-mail: [email protected] Material Approval – Tape G4000 (1/2) http:// www.smartant.com E-mail: [email protected] Material Approval - Tape G4000 (2/2) http:// www.smartant.com E-mail: [email protected] Material Approval –PE Bag (1/1) http:// www.smartant.com E-mail: [email protected] Material Approval – CTN (1/2) http:// www.smartant.com E-mail: [email protected] Material Approval – CTN (2/2) 寰波科技股份有限公司 SmartAnt Telecom Co., Ltd Products Inspection Plan Form No.:P7-RD-011-020 Rev.:A 保存期限:至該產品量產停產後 1 年 2 0 ° ± 5 2.5±0.5 2 IPEX Cable Length is 360mm - Black 1 Main antenna 4 Double-Faced Tape 10*10mm 31±1 360±4 Double-Faced Tape Side 22±1 Smartant P/N(型/料號): ADV05-22058A Inspection Date (日期): 04/10/2009 Doc No: PM09-033 Rev.: 1 Description(規格名稱): Assembly for ADV05-22058A Φ1.13 Black Manufacturing (製造商) : N/A 1.Inspectiont Item : Dimension/Function (檢驗項目:尺寸/功能) Sample size(抽樣數): 1 Defect Inspection Record No CR MA MI Apparatus (檢驗儀器) Specification(規格)- Photo __1_ NO 1NO 2NO 3 NO 4NO 5 Judgment (判定) 1 360 ± 4 mm (356~364) 358 OK 2 31±1mm (30~32) 31.01 OK 1 V 游標卡尺/ 捲尺 3 22±1mm (21~23) 22.02 OK 2.Inspection Item : Appearance(檢驗項目:外觀) Apparatus : Visual (檢測 儀器:目視) Sample Size (抽樣數) : Defect Defect No CR MA MI Specification(規格)- Photo __2_ NG Q’ty No CR MAMI Specification(規格) - Photo ___ NG Q’ty 1 V 需與圖面吻合。 9 V 銅片/IPEX 表面允許刮傷、凹陷、凸 起、氧化。但手指紋不允許。 2 V 銅片表面不可有、剝落、龜裂、異色、 電鍍不良之現象。 10 V 目視不得有毛邊、毛邊須在 0.2mm 以下不允許,不得有傷人之毛邊。 3 V 不可有缺料、混料、錯料。 11 V IPEX Cable ---Black 4 V 不可外觀變形、成型不良。 12 V 銅片/IPEX 表面允許擦傷、磨傷。 5 V 外型尺寸不合規格。 13 V 銅片表面水紋痕、滴淚狀紋可允許。 6 V 銅片切斷面處允許生銹、銹斑、氧化。 14 V銅片表面不可有油漬、色漬、髒污。 7 V 熱溶膠此為固定焊接點使用, 確定其 有無確實黏著於焊點。 15 V 銅片背面須貼付 Double-Faced Tape 10*10mm,但其外觀不作檢驗。 8 V 焊接處熱熔膠不列入外觀檢驗項目。 16 V包裝盒不作外觀檢驗。 Description(說明): 1. 檢驗重點重要項目如上NO:1~16 。 點規卡依據中華民國品質學會發行版。(EFA QC-C0192). Photo_1_ Photo _2_ 1 First Issued(新建立) Rev Engineering Change Description Issue Approval Proposer: (申請人) Jimmy 04/09/’09 QA Approval: (QA核准) Clark 04/10’09 PM Approval: (PM核准) May 04/10/’09 Customer Confirmation: (客戶確認) Flow(作業流程): 1.申請人→QA檢驗判定核准→PM核淮→由PM編號及分發(放於網路上)歸檔 2.如需要客戶確認→提供給業務→客戶確認→PM分發(放於網路上)歸檔。 熱熔膠不列入外觀檢驗 寰波科技股份有限公司 SmartAnt Telecom Co.,Ltd ADV05-22058A 2009/4/9 Environment-Related Substances Report SmartAnt P/N: Customer P/N: Ant 2.4/5G φ1.13 360/580MM(B)IPEX OF M1 Product Description: 寰波科技股份有限公司 SmartAnt Telecom Co.,Ltd. CdPbHgCr VIPBBs PBDEs Sheath / Gray N.DN.DN.DN.DN.DN.DCE/2007/A4663 Pass Sheath / Black N.DN.DN.DN.DN.DN.DCE/2008/B1636 Pass Outer Conductor N.DN.DN.DNegatuve--------CE/2008/B1640 Pass Insulation N.DN.DN.DN.DN.DN.DCE/2008/B1639 Pass Inner Conductor N.DN.DN.DNegatuve--------CE/2008/B1641 Pass Housing-Black N.D23N.DN.DN.DN.DCE/2008/31207 Pass Coetact N.D20N.DN.DN.DN.DCE/2008/31217 Pass Ground Contact N.D17N.DN.DN.DN.DCE/2008/31216 Pass 3 N.DN.DN.DNegatuveN.DN.DCE/2009/10355A Pass 4 N.D242N.DN.DN.DN.DCE/2008/32645 Pass 5 N.DN.DN.DN.DN.DN.DCE/2007/91193 Pass 裱面紙板 N.D20N.DN.DN.DN.D CE/2008/32428 Pass 瓦楞芯紙 N.D21N.DN.DN.DN.D CE/2008/32427 Pass 白膠 N.DN.DN.DN.DN.DN.D KE/2008/32592 CE/2008/22385 Pass 油墨 N.DN.DN.DN.DN.DN.D CE/2008/12889 CE/2008/77012 Pass 7 N.DN.DN.DN.DN.DN.DCE/2008/71425 Pass Double-Faced Tape SUS BEND PLANT I-PEX Connector 1 Antenna Components Ø1.13 Cable Black & Gray 2 Solder Wire ENVIRONMENT-RELATED SUBSTANCES TO BE CONTROLLED-ADV05-22058A Ite m Pass / Fail Test Item(Cr6+,Hg,Pb,PBBs,PBBEs<1000ppm,Cd<100ppm) Report No. ND = Not Detected ; "---" = Not Conducted;Negative=Absence of Cr(VI)coating/surface layer PE Bag Packing PackingPacking Packing Carton & Box 6 Remarks:

Cover Letter(s)

Sample Description : Style/Item No. : Sample Receiving Date : Testing Period : ============================================================================================ Test Result(s) : Test Report No. : CE/2008/B1636 Date : 2008/11/14 Page : 1 of 7 2008/11/07 TO 2008/11/14 Please refer to next page(s). SWCC SHOWA CABLE SYSTEMS CO., LTD. INTERCONNECTION UNIT NO. 4-1-1, MINAMI-HASHIMOTO, SAGAMIHARA-SHI, KANAGAWA, 229-1133, JAPAN 2008/11/07 *CE/2008/B1636* KHCX-32-SB-TA KHCX-32-SB-TA The following sample(s) was/were submitted and identified by/on behalf of the client as : SGS Taiwan Ltd. Chemical-Taipei 33 WuChyuan Road, Wuku Industrial Zone, Taipei County, Taiwan /33 t + 886 (02)2299 3279 f + 886 (02)2299 3237 www.sgs.com Member of the SGS Group (SGS SA) Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This test report cannot be reproduced, except in full, without prior written permission of the Company. This Test Report is issued by the Company under its General Conditions of Service printed overleaf or available on request and accessible at http://www.sgs.com/terms_and_conditions.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this Test Report is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Test Result(s) PART NAME NO.1 : Result No.1 Cadmium (Cd)mg/kg With reference to IEC 62321/2nd CDV (111/95/CDV). Determination of Cadmium by ICP-AES. 2n.d. Lead (Pb)mg/kg With reference to IEC 62321/2nd CDV (111/95/CDV). Determination of Lead by ICP-AES. 2n.d. Mercury (Hg)mg/kg With reference to IEC 62321/2nd CDV (111/95/CDV). Determination of Mercury by ICP-AES. 2n.d. Hexavalent Chromium Cr(VI) by alkaline extraction mg/kg With reference to IEC 62321/2nd CDV (111/95/CDV). Determination of Hexavalent Chromium for non- metallic samples by UV/Vis Spectrometry. 2n.d. Perfluorooctane sulfonates (PFOS) PFOS – Acid PFOS – Metal Salt PFOS – Amide mg/kg With reference to US EPA 3540C: 1996 method for PFOS Content. Analysis was performed by LC/MS. 10n.d. PFOAmg/kg With reference to US EPA 3540C: 1996 method for PFOA Content. Analysis was performed by LC/MS. 10n.d. Sum of PBBs -n.d. Monobromobiphenyl5n.d. Dibromobiphenyl5n.d. Tribromobiphenyl5n.d. Tetrabromobiphenyl5n.d. Pentabromobiphenyl5n.d. Hexabromobiphenyl5n.d. Heptabromobiphenyl5n.d. Octabromobiphenyl5n.d. Nonabromobiphenyl5n.d. Decabromobiphenyl5n.d. With reference to IEC 62321/2nd CDV (111/95/CDV). Determination of PBB and PBDE by GC/MS. MDL BLACK PLASTIC JACKET Test Item (s):UnitMethod Test Report No. : CE/2008/B1636 Date : 2008/11/14 Page : 2 of 7 SWCC SHOWA CABLE SYSTEMS CO., LTD. INTERCONNECTION UNIT*CE/2008/B1636* NO. 4-1-1, MINAMI-HASHIMOTO, SAGAMIHARA-SHI, KANAGAWA, 229-1133, JAPAN mg/kg SGS Taiwan Ltd. Chemical-Taipei 33 WuChyuan Road, Wuku Industrial Zone, Taipei County, Taiwan /33 t + 886 (02)2299 3279 f + 886 (02)2299 3237 www.sgs.com Member of the SGS Group (SGS SA) Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This test report cannot be reproduced, except in full, without prior written permission of the Company. This Test Report is issued by the Company under its General Conditions of Service printed overleaf or available on request and accessible at http://www.sgs.com/terms_and_conditions.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this Test Report is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Result No.1 Sum of PBDEs -n.d. Monobromodiphenyl ether5n.d. Dibromodiphenyl ether5n.d. Tribromodiphenyl ether5n.d. Tetrabromodiphenyl ether5n.d. Pentabromodiphenyl ether5n.d. Hexabromodiphenyl ether5n.d. Heptabromodiphenyl ether5n.d. Octabromodiphenyl ether5n.d. Nonabromodiphenyl ether5n.d. Decabromodiphenyl ether5n.d. PFOS Reference Information : Directive 2006/122/EC NoteΚ1. mg/kg = ppmΙ0.1wt% = 1000ppm 2. n.d. = Not Detected 3. MDL = Method Detection Limit 4. " - " = Not Regulated With reference to IEC 62321/2nd CDV (111/95/CDV). Determination of PBB and PBDE by GC/MS. NO. 4-1-1, MINAMI-HASHIMOTO, SAGAMIHARA-SHI, KANAGAWA, 229-1133, JAPAN (2) May not be placed on the market in semi-finished products or articles, or parts thereof, if the concentration of PFOS is equal to or higher than 0.1 % by mass calculated with reference to the mass of structurally or microstructurally distinct parts that contain PFOS or, for textiles or other coated materials, if the amount of PFOS is equal to or higher than1μg/m 2 of the coated material. (1) May not be placed on the market or used as a substance or constituent of preparations in a concentration equal to or higher than 0.005 % by mass. Test Item (s):UnitMethodMDL Test Report No. : CE/2008/B1636 Date : 2008/11/14 Page : 3 of 7 SWCC SHOWA CABLE SYSTEMS CO., LTD. INTERCONNECTION UNIT*CE/2008/B1636* mg/kg SGS Taiwan Ltd. Chemical-Taipei 33 WuChyuan Road, Wuku Industrial Zone, Tai…

Text truncated - open the document above for the full version.

Cover Letter(s)

The content of this PDF file is in accordance with the original issued reports for reference only. This Test Report cannot be reproduced, except in full, without prior written permission of the Company SGS TAIWAN LIMITED NO. 136-1, Wu Kung Road, WuKu Industrial Zone, Taipei county, Taiwan. t(886-2) 22993939 f(886-2) 2299-3237 www.sgs.com.tw . Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. The content of this PDF file is in accordance with the original issued reports for reference only. This Test Report cannot be reproduced, except in full, without prior written permission of the Company SGS TAIWAN LIMITED NO. 136-1, Wu Kung Road, WuKu Industrial Zone, Taipei county, Taiwan. t(886-2) 22993939 f(886-2) 2299-3237 www.sgs.com.tw . Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. Sample Description : Style/Item No. : Sample Receiving Date : Testing Period : ================================================================================== = Test Result(s) : I-PEX JP CO., LTD. 6-27-19 HARAMACHIDA MACHIDA-CITY TOKYO 194-0013 JAPAN The following sample(s) was/were submitted and identified by/on behalf of the client as : 2008/03/05 TO 2008/03/10 2008/03/05 MHF PLUG GROUND CONTACT 1846-0** Test Report No. : CE/2008/31216Date : 2008/03/10Page : 1 of 5 *CE/2008/31216* Please refer to next page(s). The content of this PDF file is in accordance with the original issued reports for reference only. This Test Report cannot be reproduced, except in full, without prior written permission of the Company SGS TAIWAN LIMITED NO. 136-1, Wu Kung Road, WuKu Industrial Zone, Taipei county, Taiwan. t(886-2) 22993939 f(886-2) 2299-3237 www.sgs.com.tw . Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. The content of this PDF file is in accordance with the original issued reports for reference only. This Test Report cannot be reproduced, except in full, without prior written permission of the Company SGS TAIWAN LIMITED NO. 136-1, Wu Kung Road, WuKu Industrial Zone, Taipei county, Taiwan. t(886-2) 22993939 f(886-2) 2299-3237 www.sgs.com.tw . Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. Test Result(s) PART NAME NO.1 : Result No.1 Cadmium (Cd)mg/kgWith reference to IEC 62321/2nd CDV (111/95/CDV). Determination of Cadmium by ICP-AES. 2n.d. Lead (Pb)mg/kgWith reference to IEC 62321/2nd CDV (111/95/CDV). Determination of Lead by ICP- AES. 217 Mercury (Hg)mg/kgWith reference to IEC 62321/2nd CDV (111/95/CDV). Determination of Mercury by ICP-AES. 2n.d. Hexavalent Chromium Cr(VI) by alkaline extraction mg/kgWith reference to IEC 62321/2nd CDV (111/95/CDV). Determination of Hexavalent Chromium by UV/Vis Spectrometry. 2n.d. Gold (Au)mg/kgWith reference to US EPA Method 3050B for Gold Content. Analysis was performed by ICP- AES. 22070 Nickel (Ni)mg/kgWith reference to US EPA Method 3050B for Nickel Content. Analysis was performed by ICP-AES. 220600 4. The sample(s) was/were analyzed on behalf of the applicant as mixing sample in one testing. The above result(s) was/were only given as the informality value. MethodMDLTest Item (s):Unit NoteΚ1. mg/kg = ppm 2. n.d. = Not Detected 3. MDL = Method Detection Limit GOLDEN COLORED METAL (INCLUDING THE PLATING LAYER) 6-27-19 HARAMACHIDA MACHIDA-CITY TOKYO 194-0013 JAPAN Test Report No. : CE/2008/31216Date : 2008/03/10Page : 2 of 5 I-PEX JP CO., LTD.*CE/2008/31216* The content of this PDF file is in accordance with the original issued reports for reference only. This Test Report cannot be reproduced, except in full, without prior written permission of the Company SGS TAIWAN LIMITED NO. 136-1, Wu Kung Road, WuKu Industrial Zone, Taipei county, Taiwan. t(886-2) 22993939 f(886-2) 2299-3237 www.sgs.com.tw . Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. The content of this PDF file is in accordance with the original issued reports for reference only. This Test Report cannot be reproduced, except in full, without prior written permission of the Company SGS TAIWAN LIMITED NO. 136-1, Wu Kung Road, WuKu Industrial Zone, Taipei county, Taiwan. t(886-2) 22993939 f(886-2) 2299-3237 www.sgs.com.tw . Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. Test Report I-PEX JP CO., LTD.*CE/2008/31216* 6-27-19 HARAMACHIDA MACHIDA-CITY TOKYO 194-0013 JAPAN No. : CE/2008/31216Date : 2008/03/10Page : 3 of 5 1) These samples were dissolved totally by pre-conditioning method according to below flow chart. ΰCr6+ test method excludedα 2) Name of the person who made measurement: Troy Chang 3) Name of the person in charge of measurement: Chenyu Kung Cr 6 Ѐ Sample MaterialDigestion Acid Steel, copper, aluminum, solderAqua regia, HNO 3 , HCl, HF, H 2 O 2 GlassHNO 3 /HF Gold, platinum, palladium, ceramicAqua regia SilverHNO 3 PlasticH 2 SO 4 , H 2 O 2 , HNO 3 , HCl OthersAny acid to total digestion PbΕCd Solution ICP-AES Acid digestion by suitable acid depended on different sample material (as below table) Filtration Residue 1) Alkali Fusion 2) HCl to dissolve Sample Measurement Cutting / Preparation Microwave digestion with HNO 3 /HCl/HF Heat to appropriate temperature to extract Cool, filter digestate through filter Add diphenyl-carbazide for color development measure the absorbance at 540 nm by UV-VIS Add appropriate amount of digestion reagent Hg The content of thi…

Text truncated - open the document above for the full version.

Cover Letter(s)

Sample Description : Style/Item No. : Sample Receiving Date : Testing Period : ============================================================================================ Test Result(s) : Test Report No. : CE/2008/B1636 Date : 2008/11/14 Page : 1 of 7 2008/11/07 TO 2008/11/14 Please refer to next page(s). SWCC SHOWA CABLE SYSTEMS CO., LTD. INTERCONNECTION UNIT NO. 4-1-1, MINAMI-HASHIMOTO, SAGAMIHARA-SHI, KANAGAWA, 229-1133, JAPAN 2008/11/07 *CE/2008/B1636* KHCX-32-SB-TA KHCX-32-SB-TA The following sample(s) was/were submitted and identified by/on behalf of the client as : SGS Taiwan Ltd. Chemical-Taipei 33 WuChyuan Road, Wuku Industrial Zone, Taipei County, Taiwan /33 t + 886 (02)2299 3279 f + 886 (02)2299 3237 www.sgs.com Member of the SGS Group (SGS SA) Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This test report cannot be reproduced, except in full, without prior written permission of the Company. This Test Report is issued by the Company under its General Conditions of Service printed overleaf or available on request and accessible at http://www.sgs.com/terms_and_conditions.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this Test Report is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Test Result(s) PART NAME NO.1 : Result No.1 Cadmium (Cd)mg/kg With reference to IEC 62321/2nd CDV (111/95/CDV). Determination of Cadmium by ICP-AES. 2n.d. Lead (Pb)mg/kg With reference to IEC 62321/2nd CDV (111/95/CDV). Determination of Lead by ICP-AES. 2n.d. Mercury (Hg)mg/kg With reference to IEC 62321/2nd CDV (111/95/CDV). Determination of Mercury by ICP-AES. 2n.d. Hexavalent Chromium Cr(VI) by alkaline extraction mg/kg With reference to IEC 62321/2nd CDV (111/95/CDV). Determination of Hexavalent Chromium for non- metallic samples by UV/Vis Spectrometry. 2n.d. Perfluorooctane sulfonates (PFOS) PFOS – Acid PFOS – Metal Salt PFOS – Amide mg/kg With reference to US EPA 3540C: 1996 method for PFOS Content. Analysis was performed by LC/MS. 10n.d. PFOAmg/kg With reference to US EPA 3540C: 1996 method for PFOA Content. Analysis was performed by LC/MS. 10n.d. Sum of PBBs -n.d. Monobromobiphenyl5n…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Lily Huang(Manager)
[email protected]886-2-77323399Fax: 886-2-2794-7334

Technical Contact

Compliance Certification Services Inc.Gloria Chang
[email protected]886-3-5921698

NO. 989-1 Wen Shan Rd., Shang Shan Village, · Taiwan

Non-Technical Contact

Compliance Certification Services Inc.Gloria Chang
[email protected]886-3-5921698

Test Firm

Compliance Certification Services Inc.Winnie Chen
[email protected]886-3-5921698Fax: 886-3-5921108

Technical Specifications

#Rule PartsFrequency RangePower Output
415E5.75 GHz - 5.83 GHz116.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40 MHz bandwidth modes.

Other Applications from Advantech Co Ltd

M82-AIW-172

Wi-Fi 7 AIW-172 module

Jul 27, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
M82-AIW-411

Wireless MCU with Integrated Wi-Fi 6 and BLE/802.15.4 module

Jun 22, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
COMPUTER - FCC ID M82-PWS872FL - Advantech Co Ltd
M82-PWS872FL

COMPUTER

Mar 13, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
M82-WISE6610V2

Gateway

Jun 24, 2024

Equipment Class

DTS - Digital Transmission System
10.1 inch Tablet PC - FCC ID M82-AIM78S6 - Advantech Co Ltd
M82-AIM78S6

10.1 inch Tablet PC

Jan 31, 2023

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter