FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Sagem Wireless/
  3. M9H95A03AG2

M9H95A03AG2GSM Dual Band 850/1900 MHz Mobile Phone

Sagem Wireless
GSM Dual Band 850/1900 MHz Mobile Phone - FCC ID M9H95A03AG2 - Sagem Wireless
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
May 10, 2004
Application Purpose
Original Equipment
Date of Application
May 10, 2004
Equipment Note
GSM Dual Band 850/1900 MHz Mobile Phone
Frequency Range
824.20000000 - 848.80000000
Company
Sagem Wireless
Country
France

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 You have just bought a mobile phone and we congratulate you on your choice. Your phone will allow you to use different international networks (GSM 850 MHz and PCS 1900 MHz) depending on the roaming agreements between the operators. We would like to remind you that this phone is approved to European standards. To get the most out of using your phone, we recommend that you read this manual carefully and keep it handy for future reference if needed. WARNING According to the configuration of the networks and associated subscriptions, certain functions may not be available (usually indicated by *). Make sure your SIM card is compatible with your phone. If an incompatible SIM card is inserted, a message will be displayed when switching on your phone. For further information, contact your Operator. The SAGEM logo and trademark are the property of SAGEM SA. AT is a registered trademark of Hayes Microcomputer products Inc. Hayes is a registered trademark of Hayes Microcomputer Products Inc. T9™ Text Input is a registered trademark of ©Tegic Communications Inc. T9 is licensed under one or more of the following U.S. Patents: 5,818,437, 5,953,541, 5,187,480, 5,945,928, 6,011,554 and additional patents are pending worldwide. Compatibility of your SIM card Your phone is compatible with SIM 3V cards only. myX-1a twin PCS_en_00.pmd23/06/2004, 10:501 2 Conformance Document SAGEM SA declare under its sole responsibility that the product Dual Band GSM/PCS Type A2003 conforms to the requirements of the following EEC directives: EEC Directive1999/5/CE SafetyEN 60950: 2000 EMCEN 301 489-1 EN 301 489-7 Low voltage directive73/23/CEE Network3GPP TS 51.010-1 with GCF-CC v3.12.1 included TBR 19 Edition 5 TBR 20 Edition 3 EN 301511 v7.0.1 HealthEN 50360 EN 50361 FCC Conformance Document FCC Part 24 NetworkNAPRD03 v2.9.1 HealthDraft IEEE Std P1528/D1.2 myX-1a twin PCS_en_00.pmd23/06/2004, 10:502 3 Use of your phone is subject to safety rules designed to protect the user and his or her environment. Exposure to Radio Frequency Signals •Your wireless handheld portable phone is a low power radio transmitter and receiver. When it is ON, it receives and also sends out frequency (RF) signals. •In August, 1996, the Federal Communications Commissions (FCC) adopted RF exposure guidelines with safety levels for handheld wireless phones. Those guidelines are consistent with the safety standards previously set by both U.S. and international standards bodies: ANSI C95.1 (1992)* NCPR Report 86 (1986)* ICNIRP (1996)* (*) American National Standards Institute; National Council on Radiation Protection and Measurements; International Commission and Non-Ionizing Radiation Protection. •Those standards were based on comprehensive and periodic evaluations of the relevant scientific literature. For example, over 120 scientists, engineers, and physicians from universities, government health agencies, and industry reviewed the available body of research to develop the ANSI Standard (C95.1). •The design of your phone complies with the FCC guidelines (and those standards). Safety Information for Wireless handled phones myX-1a twin PCS_en_00.pmd23/06/2004, 10:503 4 •For body worn operation, this phone has been tested and meets FCC RF exposure guidelines when used with an accessory that contains no metal and that positions the handset a minimum of 1.5 cm from the body. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. Phone Operation •Normal position: hold the phone as you would any other phone with the upper zone (back of the LCD display) pointed up and over your shoulder. •Tips on efficient operation: for your phone to operate most efficiently: do not touch cover unnecessarily the top part of the phone with your hand. This would cover the integrated antenna and affect call quality and may cause the phone to operate at a higher power level than otherwise needed. Driving •Check the laws and regulations on the use of wireless telephones in the areas where you drive. Always obey them. Also, if using your phone while driving while driving please: - Give full attention of driving, driving safely is your first responsibility - Use hands-free operation, if available - Pull off the road and park before making or answering a call if driving conditions so require. Safety Information for Wireless handled phones myX-1a twin PCS_en_00.pmd23/06/2004, 10:504 5 Electronic Devices •Most modern electronic equipment is shielded from RF signals. However, certain electronic equipment may not be shielded against the RF signals from your wireless phone. •Some phone accessories allow to reduce the radiation interferences of the phone. Please contact your distributor. Pacemakers The Health Industry Manufacturers Association recommends that a minimum separation of six (6”) inches be maintained between a handheld wireless phone and a pacemaker to avoid potential interference with the pacemaker. These recommendations are consistent with the independent research by and recommendations of Wireless Technology Research. Persons with pacemakers: •Should ALWAYS keep the phone more than six inches from their pacemaker when the phone is turned ON •Should not carry the phone in the breast pocket •Should use the ear opposite to the pacemaker to minimize the potential for interference •If you have any reason to suspect that interference is taking place, turn your phone OFF immediately. Safety Information for Wireless handled phones myX-1a twin PCS_en_00.pmd23/06/2004, 10:505 6 Hearing Aids Some digital wireless phones may interfere with some hearing aids. In the event of such interference, you may want to consult your service provider. Other Medical Devices If you use any other personal medical device, consult the manufacturer of your device to determine if they are adequately shielded from external RF energy. Your physician may be able to assist you in obtaining this information. Turn your phone OFF in health care facilities when any regulations…

Text truncated - open the document above for the full version.

External Photos

CETECOM ICT Services GmbH Test report No..: 4-1220-06-04/04Date: 2004.03.08Page 114 (120) Photographs of Equipment Photo No.: 06

ID Label/Location Info

s e Centre de Saint Christophe - DTM TELEPHONIE MOBILE MOBILE PHONES Ref : SCT TMO A2003 SPEC 54 A Date : 13/04/04 Document E Reproduction et divulgation interdites 9/18 2.1.2 Label description

Internal Photos

CETECOM ICT Services GmbH Test report No..: 4-1220-06-04/04Date: 2004.03.08Page 115 (120) Photographs of Equipment Photo No.: 07 CETECOM ICT Services GmbH Test report No..: 4-1220-06-04/04Date: 2004.03.08Page 116 (120) Photographs of Equipment Photo No.: 08 CETECOM ICT Services GmbH Test report No..: 4-1220-06-04/04Date: 2004.03.08Page 117 (120) Photographs of Equipment Photo No.: 09 CETECOM ICT Services GmbH Test report No..: 4-1220-06-04/04Date: 2004.03.08Page 118 (120) Photographs of Equipment Photo No.: 10 CETECOM ICT Services GmbH Test report No..: 4-1220-06-04/04Date: 2004.03.08Page 119 (120) Photographs of Equipment Photo No.: 11 CETECOM ICT Services GmbH Test report No..: 4-1220-06-04/04Date: 2004.03.08Page 120 (120) Photographs of Equipment Photo No.: 12

RF Exposure Info

CETECOM ICT Services GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken, Germany Phone: +49 (0) 681 598-0 Fax: -8475 SAR-Laboratory Phone: +49 (0) 681 598-8454 . As of March 29, 2004 Page 1 of 42 Accredited testing laboratory DAR registration number: TTI-P-G 166/98 Federal Motor Transport Authority (KBA) DAR registration number: KBA-P 00070-97 Appendix to the Report 4-1220-06-02/04 Calibration Data, Phantom Certificate and detail Information of the DASY 4 System CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 2 of 42 Table of Content 1. Calibration report “Probe ET3DV6” ......................................................................................................................................3 2. Calibration report “1900 MHz System validation dipole”...................................................................................................14 3. Calibration report “900 MHz System validation dipole” ....................................................................................................24 4. Calibration certificate of Data Aquisition Unit (DAE) .........................................................................................................34 5. Certificate of Conformity “SAM Twin Phantom V4.0/V4.0C” ...........................................................................................35 6. Application Note Validation and system Check ...................................................................................................................37 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 3 of 42 1. Calibration report “Probe ET3DV6” CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 4 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 5 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 6 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 7 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 8 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 9 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 10 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 11 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 12 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 13 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 14 of 42 2. Calibration report “1900 MHz System validation dipole” CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 15 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 16 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 17 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 18 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 19 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 20 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 21 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 22 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 23 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 24 of 42 3. Calibration report “900 MHz System validation dipole” CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 25 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 26 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 27 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 28 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 29 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 30 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 31 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 32 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 33 of 42 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1220-06-02/04 As of March 29, 2004 Page 34 of 42 4. Calibration certificate of Data Aquisition Unit (DAE) CETECOM ICT Ser…

Text truncated - open the document above for the full version.

RF Exposure Info

CETECOM ICT Services GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken, Germany Phone: +49 (0) 681 598-0 Fax: -8475 SAR-Laboratory Phone: +49 (0) 681 598-8454 . As of March 30, 2004 Page 1 of 68 Accredited testing laboratory DAR registration number: TTI-P-G 081/94-D0 Federal Motor Transport Authority (KBA) DAR registration number: KBA-P 00070-97 Test report no. : 4-1220-06-02/04 Type identification : A2003agR2 (myX-1ag) Test specification : IEEE P1528/D1.2 FCC-ID : M9H95A03AG2 Test specification : CETECOM ICT Services GmbH Test report no.: 4-1220-06-02/04 As of March 30, 2004 Page 2 of 68 Table of Contents 1 General Information ...............................................................................................................................................................3 1.1 Notes ................................................................................................................................................................................3 1.1.1 Statement of Compliance........................................................................................................................................3 1.2 Testing laboratory ............................................................................................................................................................4 1.3 Details of applicant ..........................................................................................................................................................4 1.4 Application details ...........................................................................................................................................................4 1.5 Test item...........................................................................................................................................................................5 1.6 Test specification(s) .........................................................................................................................................................6 1.6.1 RF exposure limits ..................................................................................................................................................6 2 Technical test..........................................................................................................................................................................7 2.1 Summary of test results ....................................................................................................................................................7 2.2 Test environment..............................................................................................................................................................7 2.3 Measurement and test set-up ............................................................................................................................................7 2.4 Measurement system ........................................................................................................................................................8 2.4.1 System Description .................................................................................................................................................8 2.4.2 Test environment ....................................................................................................................................................9 2.4.3 Probe description ....................................................................................................................................................9 2.4.4 Phantom description .............................................................................................................................................10 2.4.5 Device holder description .....................................................................................................................................10 2.4.6 Scanning procedure ..............................................................................................................................................11 2.4.7 Spatial Peak SAR Evaluation ...............................................................................................................................12 2.4.8 Data Storage and Evaluation ................................................................................................................................13 2.4.9 Test equipment utilized.........................................................................................................................................15 2.4.10 Tissue simulating liquids : dielectric properties ...................................................................................................16 2.4.11 Tissue simulating liquids : parameters..................................................................................................................17 2.4.12 Measurement uncertainty evaluation for SAR test ...............................................................................................18 2.4.13 Measurement uncertainty evaluation for system validation..................................................................................19 2.4.14 System validation .................................................................................................................................................20 2.4.15 Validation procedure ............................................................................................................................................21 2.5 Test results (Head and Body SAR) ................................................................................................................................22 2.5.1 Description of test procedures ..............................................................................................................................23 2.6 Test results (conducted power measure…

Text truncated - open the document above for the full version.

Test Report

CETECOM ICT Services GmbH Radio Satellite Communication Untertürkheimer Straße 6-10 . D-66117 Saarbrücken Telefon: +49 (0)681 598-0 Telefax: - 9075 Test report No.: 4-1220-06-04/04 This test report consists of 120 pagesPage 1 (120) BLUETOOTH TM is a trademark owned by Bluetooth SIG, Inc. and licensed to CETECOM Recognized by the Federal Communications Commission Anechoic chamber registration no.: 90462 (FCC) Anechoic chamber registration no.: 3463 (IC) TCB ID: DE 0001 Accredited by the German Accreditation Council DAR–Registration Number TTI–P–G 081/94-D0 Independent ETSI compliance test house ETSI Accredited Bluetooth™ Test Facility (BQTF) Test report no.: 4-1220-06-04/04 Applicant:Sagem TypeA 2003agR2 FCC Part 24 / 22 / 15 FCC ID:M9H95A03AG2 CETECOM ICT Services GmbH Test report No..: 4-1220-06-04/04Date: 2004.03.08Page 2 (120) Table of Contents 1 General information 1.1 Notes 1.2 Testing laboratory 1.3 Details of applicant 1.4 Application details 1.5 Test item 1.6 Test standards 2 Technical test 2.1 Summary of test results 2.2 Test report CETECOM ICT Services GmbH Test report No..: 4-1220-06-04/04Date: 2004.03.08Page 3 (120) 1 General information 1.1 Notes The test results of this test report relate exclusively to the test item specified in 1.5. The CETECOM ICT Services GmbH does not assume responsibility for any conclusions and generalizations drawn from the test results with regard to other specimens or samples of the type of the equipment represented by the test item. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of the CETECOM ICT Services GmbH. 1.2Testing laboratory CETECOM ICT Services GmbH Untertürkheimer Straße 6 - 10 66117 Saarbrücken Germany Telephone: + 49 681 598 - 9100 Telefax : + 49 681 598 - 9075 E-mail: [email protected] Internet: www.cetecom-ict.de Accredited testing laboratory The test laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025. DAR registration number: TTI-P-G-081/94-D0 Listed by: Federal Communications Commission (FCC) Identification/Registration No : 90462 Accredited Bluetooth TM Test Facility (BQTF) BLUETOOTH TM is a trademark owned by Bluetooth SIG, Inc. and licensed to CETECOM 1.3Details of applicant Name : Sagem SA Street : 2-4, rue du Petit Albi City : 95800 Cergy Saint – Christophe Country : France Telephone : + 33 1 34 25 37 37 Telefax : + 33 1 34 25 74 16 Contact : Jean Marquet Telephone : + 33 1 34 25 37 37 e-mail: [email protected] 1.4 Application details Date of test : 2004-03-03 to 2004-03-05 CETECOM ICT Services GmbH Test report No..: 4-1220-06-04/04Date: 2004.03.08Page 4 (120) 1.5 Test item Type of equipment :GSM/Dual band mobile phone 850/1900 Type designation:A2003agR2 (myX-1ag twin) Manufacturer:applicant Street: City: Country: Serial numbers: Additional information: : Frequency:1850.2 – 1909.8 MHz and 824.2 – 848.8 MHz Type of modulation:300KGXW / 200KQ7W Number of channels :300 (PCS1900) and 125 (PCS850) Antenna:Integral antenna Power supply (normal):3,9 V DC Li-Polymer Battery Power supply (extreme):3.55 V to 3.90 V Output power GSM 850:cond.: 33.4 dBm Peak, ERP: 24.4 dBm (Burst); EIRP: 26.55 dBm (Burst) Output power GSM 1900 :cond : 29.8 dBm Peak, ERP: 25.95 dBm (Burst); EIRP: 28.1 dBm (Burst) Type of equipment:Temperature range : -30°C - +60°C FCC – ID:M9H95A03AG2 Hardware:V0x Software:J3, FK Test set up Mobile; S/N: 2242394395; IMEI: 351816950006209 Mobile; S/N: 2242394385; IMEI: 351816950006217 Mobile; S/N: 2242394402; IMEI: 351816950006190 Headset (Deluxe Pedestrian Kit) S/N: 188133803 USB Data Cable; S/N:251214324 Cigar Light Charger: S/N: 188187794 Multi Countries AC/DC Adapter; S/N 188218106 CE AC/DC Adapter; S/N: 187849535 US AC/DC Adapter; S/N: 185982340 1.6Test standards: FCC Part 24, 22 FCC Part 15 CETECOM ICT Services GmbH Test report No..: 4-1220-06-04/04Date: 2004.03.08Page 5 (120) 2 Technical test For Part 24/22 we use the substitution method ( TIA/EIA 603). All measurements in this report were performed in GSM circuit - switched mode in both bands 850 and 1900 MHz. The handset does not offer GPRS or multislot service. Remarks: Test setup: The radiated measurements were performed with an AC/DC charging unit No deviations from the technical specification(s) were ascertained in the course of the tests performed. FINAL VERDICT: PASS Technical responsibility for area of testing : 2004-03-08RSC 8431 Gillmann DateSectionNameSignature Technical responsibility for area of testing : 2004-03-08RSC8412Hausknecht D. DateSectionNameSignature CETECOM ICT Services GmbH Test report No..: 4-1220-06-04/04Date: 2004.03.08Page 6 (120) TEST REPORT REFERENCE LIST OF MEASUREMENTS PARAMETER TO BE MEASURED PAGE PART PCS 1900 POWER OUTPUT SUBCLAUSE § 24.2327 FREQUENCY STABILITY SUBCLAUSE § 24.23510 AFC FREQ ERROR VS. VOLTAGE11 AFC FREQ ERROR VS. TEMPERATURE11 EMISSIONS LIMITS SUBCLAUSE §24.23813 RECEIVER SPURIOUS RADIATION SUBCLAUSE § 15.10924 CONDUCTED SPURIOUS EMISSIONS36 BLOCK EDGE COMPLIANCE FOR BLOCK A AND C45 OCCUPIED BANDWIDTH SUBCLAUSE §2.98947 CONDUCTED EMISSIONS SUBCLAUSE § 15.107/20748 PART PCS 850 POWER OUTPUT SUBCLAUSE § 22.91354 FREQUENCY STABILITY SUBCLAUSE § 22.35557 AFC FREQ ERROR VS. VOLTAGE63 AFC FREQ ERROR VS. TEMPERATURE64 EMISSIONS LIMITS SUBCLAUSE §22.91760 RECEIVER SPURIOUS RADIATION SUBCLAUSE § 15.10971 CONDUCTED SPURIOUS EMISSIONS75 BLOCK EDGE REQUIREMENTS84 OCCUPIED BANDWIDTH SUBCLAUSE §2.98986 EMISSION LIMITATIONS FOR CELLULAR SUBCLAUSE §22.917(F)92 RADIATED EMISSIONS SUBCLAUSE § 15.209101 CONDUCTED EMISSIONS SUBCLAUSE § 15.107/207104 ADDITIONAL MEASUREMENT WITH ACCORIESES ACC. SUCLAUSE § 15.205101 TEST EQUIPMENT AND ANCILLARIES USED FOR TESTS107 TEST SITE AND PHOTOS OF EQUIPMENT 109 CETECOM ICT Services GmbH Test report No..: 4-1220-06-04/04Date: 2004.03.08Page 7 (120) REFERENCE NUMBER(S) OF TEST EQUIPMENT USED (for reference numbers see test equipment listing) 64 PART PCS 1900 PO…

Text truncated - open the document above for the full version.

Test Setup Photos

CETECOM ICT Services GmbH Test report No..: 4-1220-06-04/04Date: 2004.03.08Page 109 (120) Test site Photo No.: 01 CETECOM ICT Services GmbH Test report No..: 4-1220-06-04/04Date: 2004.03.08Page 110 (120) Test site Photo No.: 02 CETECOM ICT Services GmbH Test report No..: 4-1220-06-04/04Date: 2004.03.08Page 111 (120) Test site Photo No.: 03 CETECOM ICT Services GmbH Test report No..: 4-1220-06-04/04Date: 2004.03.08Page 112 (120) Test site Photo No.: 04 CETECOM ICT Services GmbH Test report No..: 4-1220-06-04/04Date: 2004.03.08Page 113 (120) Test site Photo No.: 05

Contact Information

Applicant

Francois CHAMBON(GM)
[email protected]86-574-2796-0448Fax: 86-574-2796-0997

Test Firm

Cetecom ICT Services GmbHRalf Hoehn
[email protected]49-681-598-8455Fax: 49-681-598-8475

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
222H824.2 MHz - 848.8 MHz275.00 mW300KGXW0.022 ppm
Confidentiality
Long Term
Grant Notes
Power listed is ERP for part 22 and EIRP for part 24. This filing is only applicable for GSM 850/1900 operations. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic and a minimum distance of 15 mm to the body. End-users must be provided with the appropriate information for satisfying RF exposure compliance. Highest reported SAR values are: Part 24 - Head: 0.587 W/kg, Body: 0.379 W/kg; Part 22 - Head: 0.571 W/kg, Body: 0.767 W/kg

Other Applications from Sagem Wireless

COSY Phone 3G - FCC ID M9HCOSY3G - Sagem Wireless
M9HCOSY3G

COSY Phone 3G

Oct 13, 2010

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
COSY Phone 2G - FCC ID M9HCOSY2G - Sagem Wireless
M9HCOSY2G

COSY Phone 2G

Sep 06, 2010

Equipment Class

PCE - PCS Licensed Transmitter held to ear
Handheld Top Up Terminal - FCC ID M9HMOV001 - Sagem Wireless
M9HMOV001

Handheld Top Up Terminal

Aug 18, 2010

Equipment Class

PCT - PCS Licensed Transmitter worn on body
Mobile phone - FCC ID M9HPM1 - Sagem Wireless
M9HPM1

Mobile phone

Apr 26, 2010

Equipment Class

PCE - PCS Licensed Transmitter held to ear
Network Measurement Device - FCC ID M9HOT8X0RF - Sagem Wireless
M9HOT8X0RF

Network Measurement Device

Jan 31, 2010

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral