CETECOM ICT Services GmbH Test report no..: 4-0902-19-04/03Issue Date: 2003-10-15Page 85 (91) PHOTOGRAPH OF THE EQUIPMENT AC/DC adapter “187849535” CETECOM ICT Services GmbH Test report no.: 4-0902-19-03/03-B As of October 17, 2003Page 37 of 66 Picture no. 2 DUT - front view CETECOM ICT Services GmbH Test report no.: 4-0902-19-03/03-B As of October 17, 2003Page 38 of 66 Picture no. 3 DUT - side view CETECOM ICT Services GmbH Test report no.: 4-0902-19-03/03-B As of October 17, 2003Page 39 of 66 Picture no. 4 DUT - rear view CETECOM ICT Services GmbH Test report no..: 4-0902-19-04/03Issue Date: 2003-10-15Page 87 (91) PHOTOGRAPH OF THE EQUIPMENT AC/DC adapter “185982340” CETECOM ICT Services GmbH Test report no..: 4-0902-19-04/03Issue Date: 2003-10-15Page 88 (91) PHOTOGRAPH OF THE EQUIPMENT Data Cable CETECOM ICT Services GmbH Test report no..: 4-0902-19-04/03Issue Date: 2003-10-15Page 89 (91) PHOTOGRAPH OF THE EQUIPMENT Cigar Lighter adapter “188187794” CETECOM ICT Services GmbH Test report no..: 4-0902-19-04/03Issue Date: 2003-10-15Page 90 (91) PHOTOGRAPH OF THE EQUIPMENT Head-Set “238125170” CETECOM ICT Services GmbH Test report no..: 4-0902-19-04/03Issue Date: 2003-10-15Page 91 (91) PHOTOGRAPH OF THE EQUIPMENT Car Kit “A17-BA10-01: 187012435”
CETECOM ICT Services GmbH Test report no..: 4-0902-19-04/03Issue Date: 2003-10-15Page 81 (91) PHOTOGRAPH OF THE EQUIPMENT
CETECOM ICT Services GmbH Test report no..: 4-0902-19-04/03Issue Date: 2003-10-15Page 82 (91) PHOTOGRAPH OF THE EQUIPMENT CETECOM ICT Services GmbH Test report no..: 4-0902-19-04/03Issue Date: 2003-10-15Page 83 (91) PHOTOGRAPH OF THE EQUIPMENT CETECOM ICT Services GmbH Test report no..: 4-0902-19-04/03Issue Date: 2003-10-15Page 84 (91) PHOTOGRAPH OF THE EQUIPMENT
CETECOM ICT Services GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken, GermanyPhone: +49 (0) 681 598-0Fax: -8475 SAR-Laboratory Phone: +49 (0) 681 598-8454 . As of October 20, 2003Page 1 of 32 Accredited testing laboratory DAR registration number: TTI-P-G 166/98 Federal Motor Transport Authority (KBA) DAR registration number: KBA-P 00070-97 Appendix to the Report 4-0902-19-03/03-B Calibration Data, Phantom Certificate and detail Information of the DASY4 System Test specification : CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0902-19-03/03-B As of October 20, 2003Page 2 of 32 Table of Content 1Calibration report “Probe ET3DV6”.............................................................................................................................................3 2Calibration report “1900 MHz System validation dipole”.......................................................................................................14 3Calibration certificate of Data Aquisition Unit (DAE)..............................................................................................................24 4Certificate of Conformity “SAM Twin Phantom V4.0/V4.0C”................................................................................................25 5Application Note System Performance Check...........................................................................................................................27 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0902-19-03/03-B As of October 20, 2003Page 3 of 32 1 Calibration report “Probe ET3DV6” CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0902-19-03/03-B As of October 20, 2003Page 4 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0902-19-03/03-B As of October 20, 2003Page 5 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0902-19-03/03-B As of October 20, 2003Page 6 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0902-19-03/03-B As of October 20, 2003Page 7 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0902-19-03/03-B As of October 20, 2003Page 8 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0902-19-03/03-B As of October 20, 2003Page 9 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0902-19-03/03-B As of October 20, 2003Page 10 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0902-19-03/03-B As of October 20, 2003Page 11 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0902-19-03/03-B As of October 20, 2003Page 12 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0902-19-03/03-B As of October 20, 2003Page 13 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0902-19-03/03-B As of October 20, 2003Page 14 of 32 2 Calibration report “1900 MHz System validation dipole” CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0902-19-03/03-B As of October 20, 2003Page 15 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0902-19-03/03-B As of October 20, 2003Page 16 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0902-19-03/03-B As of October 20, 2003Page 17 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0902-19-03/03-B As of October 20, 2003Page 18 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0902-19-03/03-B As of October 20, 2003Page 19 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0902-19-03/03-B As of October 20, 2003Page 20 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0902-19-03/03-B As of October 20, 2003Page 21 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0902-19-03/03-B As of October 20, 2003Page 22 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0902-19-03/03-B As of October 20, 2003Page 23 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0902-19-03/03-B As of October 20, 2003Page 24 of 32 3 Calibration certificate of Data Aquisition Unit (DAE) CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0902-19-03/03-B As of October 20, 2003Page 25 of 32 4 Certificate of Conformity “SAM Twin Phantom V4.0/V4.0C” CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0902-19-03/03-B As of October 20, 2003Page 26 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0902-19-03/03-B As of October 20, 2003Page 27 of 32 5 Application Note System Performance Check 5.1.1.1 Purpose of system performance check The system performance check verifies that the system operates within its specifica-tions. System and operator errors can be detected and corrected. It is recommended that the system performance check is performed prior to any usage of the system in order to guarantee reproducible results. The measurement of the Specific Absorption Rate (SAR) is a complicated task and the result depends on the proper functioning of many components and the correct settings of many param-eters. Faulty results due to drift, failures or incorrect parameters might not be recognized, since they often look similar in distribution to the correct ones. The Dosimetric Assessment System DASY4 incorporates a system performance check procedure to test the proper functioning of the system. The system performance check uses normal SAR measurements in a simplified setup (the at section of the SAM Twin Phantom) with…
Text truncated - open the document above for the full version.
CETECOM ICT Services GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken, Germany Phone: +49 (0) 681 598-0 Fax: -8475 SAR-Laboratory Phone: +49 (0) 681 598-8454 . As of October 17, 2003 Page 1 of 67 Accredited testing laboratory DAR registration number: TTI-P-G 166/98 Federal Motor Transport Authority (KBA) DAR registration number: KBA-P 00070-97 Test report no. : 4-0902-19-03/03-B Type identification : myX-1p (A2003p) Test specification : IEEE P1528/D1.2 FCC-ID : M9H95A2003P Test specification : CETECOM ICT Services GmbH Test report no.: 4-0902-19-03/03-B As of October 17, 2003 Page 2 of 67 Table of Contents 1 General Information ...............................................................................................................................................................3 1.1 Notes...............................................................................................................................................................................3 1.1.1 Statement of Compliance........................................................................................................................................3 1.2 Testing laboratory...........................................................................................................................................................4 1.3 Details of applicant .........................................................................................................................................................4 1.4 Application details ..........................................................................................................................................................4 1.5 Test item .........................................................................................................................................................................5 1.6 Test specification(s)........................................................................................................................................................6 1.6.1 RF exposure limits ..................................................................................................................................................6 2 Technical test..........................................................................................................................................................................7 2.1 Summary of test results ..................................................................................................................................................7 2.2 Test environment ............................................................................................................................................................7 2.3 Measurement and test set-up ..........................................................................................................................................7 2.4 Measurement system ......................................................................................................................................................8 2.4.1 System Description .................................................................................................................................................8 2.4.2 Test environment ....................................................................................................................................................9 2.4.3 Probe description ....................................................................................................................................................9 2.4.4 Phantom description .............................................................................................................................................10 2.4.5 Device holder description .....................................................................................................................................10 2.4.6 Scanning procedure ..............................................................................................................................................11 2.4.7 Spatial Peak SAR Evaluation ...............................................................................................................................12 2.4.8 Data Storage and Evaluation ................................................................................................................................13 2.4.9 Test equipment utilized.........................................................................................................................................15 2.4.10 Tissue simulating liquids : dielectric properties ...................................................................................................16 2.4.11 Tissue simulating liquids : parameters..................................................................................................................17 2.4.12 Measurement uncertainty evaluation for SAR test ...............................................................................................18 2.4.13 Measurement uncertainty evaluation for system validation..................................................................................19 2.4.14 System validation .................................................................................................................................................20 2.4.15 Validation procedure ............................................................................................................................................21 2.5 Test results (Head and Body SAR)...............................................................................................................................22 2.5.1 Description of test procedures ..............................................................................................................................22 2.6 Test results (conducted power measurement) ...........…
Text truncated - open the document above for the full version.
CETECOM ICT Services GmbH Radio Satellite Communication Untertürkheimer Straße 6-10 . D-66117 SaarbrückenTelefon: +49 (0)681 598-9100Telefax: -9075 RSC14Issued test report consists of 91 pagesPage 1 (91) BLUETOOTH TM is a trademark owned by Bluetooth SIG, Inc. and licensed to CETECOM Recognized by the Federal Communications Commission Anechoic chamber registration no.: 90462 (FCC) Anechoic chamber registration no.: 3463 (IC) TCB ID: DE 0001 Accredited by the German Accreditation Council DAR–Registration Number TTI–P–G 166/98 Independent ETSI compliance test house ETSI Accredited Bluetooth™ Test Facility (BQTF) Test report no.: 4-0902-19-04/03 FCC Part 24/15 A2003P FCC ID: M9H95A2003P CETECOM – ICT Services GmbH Untertürkheimerstr. 6-10 66117 Saarbrücken, Germany Telephone: + 49 (0) 681 / 598-0 Fax: + 49 (0) 681 / 598-9075 CETECOM ICT Services GmbH Test report no..: 4-0902-19-04/03Issue Date: 2003-12-01Page 2 (91) Table of Contents 1 General information 1.1 Notes 1.2 Testing laboratory 1.2 Details of applicant 1.4 Application details 1.5 Test item 1.6 Test standards 2 Technical test 2.1 Summary of test results 2.2 Test report CETECOM ICT Services GmbH Test report no..: 4-0902-19-04/03Issue Date: 2003-12-01Page 3 (91) 1 General information 1.1 Notes The test results of this test report relate exclusively to the test item specified in 1.5. The CETECOM ICT Services GmbH does not assume responsibility for any conclusions and generalizations drawn from the test results with regard to other specimens or samples of the type of the equipment represented by the test item. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of the CETECOM ICT Services GmbH. 1.2Testing laboratory CETECOM ICT Services GmbH Untertürkheimer Straße 6 - 10 66117 Saarbrücken Germany Telefone: + 49 681 598 - 9100 Telefax : + 49 681 598 - 9075 E-mail: [email protected] Internet: www.cetecom-ict.de Accredited testing laboratory The test laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025. DAR registration number: TTI-P-G-166/98 Listed by: Federal Communications Commission (FCC) Identification/Registration No : 90462 Accredited Bluetooth TM Test Facility (BQTF) BLUETOOTH TM is a trademark owned by Bluetooth SIG, Inc. and licensed to CETECOM CETECOM ICT Services GmbH Test report no..: 4-0902-19-04/03Issue Date: 2003-12-01Page 4 (91) 1.3Details of applicant Name : SAGEM SA Street : 2-4, rue du Petit Albi City : F-95800 Cergy Saint-Christophe Country : France Telephone : +33 1 30 73 37 37 Telefax : +33 1 34 25 74 16 Contact : Mr. Jean Marquet Telephone : +33 1 30 73 37 37 e-mail: [email protected] 1.4Application details Date of receipt of application : 2003-08-14 Date of receipt of test item : 2003-08-14 Date of test : 2003-10-06 to 2003-10-07 1.5Test item Type of equipment : Dual Band GSM/PCS Mobile Phone (GSM900 / PCS 1900) Type designation:A2003P Manufacturer:- applicant - Street: City: Country: Serial numbers:IMEI : 352328000000892 Additional information : Frequency:1850.2 – 1909.8 MHz Type of modulation:300KGXW Number of channels :300 (PCS1900) Antenna:Integral antenna Power supply:3,8V DC Li-ion Battery Output power PCS 1900:cond : 30.66 dBm Peak , ERP: 26.21 dBm (Burst); EIRP: 28.31 dBm (Burst) Type of equipment:Temperature range : -30°C - +60°C FCC – ID:M9H95A2003P Hardware:V0x Software:J-3,FB 1.6Test standards: FCC Part 24 FCC Part 15 CETECOM ICT Services GmbH Test report no..: 4-0902-19-04/03Issue Date: 2003-12-01Page 5 (91) 2 Technical test For Part 24 we use the substitution method ( TIA/EIA 603). All measurements in this report are done in GSM mode. Remarks: Test setups : Radiated measurements: 1.) Mobile with AC/DC adapter “187849535” and Data Cable Conducted measurements: 2.) Mobile with AC/DC adapter “188055939” (not for use in U.S.A.) 3.) Mobile with AC/DC adapter “185982340” 4.) Mobile with AC/DC adapter “187849535” and Data Cable Part15: 5.) Mobile with AC/DC adapter “187849535” and Data Cable 6.) Mobile with AC/DC adapter “188055939” (not for use in U.S.A.) 7.) Mobile with AC/DC adapter “185982340” 8.) Mobile with Cigar Lighter adapter “188187794” 9.) Mobile with Headset “238125170” 10.) Mobile with Car Kit “A17-BA10-01: 187012435” No deviations from the technical specification(s) were ascertained in the course of the tests performed. FINAL VERDICT: PASS Technical responsibility for area of testing : 2003-10-15RSC 8414 Ames H. DateSectionNameSignature Technical responsibility for area of testing : 2003-10-15RSC8412Hausknecht D. DateSectionNameSignature CETECOM ICT Services GmbH Test report no..: 4-0902-19-04/03Issue Date: 2003-12-01Page 6 (91) 2.2Test report TEST REPORT Test report no. : 4-0902-19-04/03 CETECOM ICT Services GmbH Test report no..: 4-0902-19-04/03Issue Date: 2003-12-01Page 7 (91) TEST REPORT REFERENCE LIST OF MEASUREMENTS PARAMETER TO BE MEASURED PAGE Part PCS 1900 POWER OUTPUT SUBCLAUSE § 24.2328 FREQUENCY STABILITY SUBCLAUSE § 24.23510 AFC FREQ ERROR vs. VOLTAGE11 AFC FREQ ERROR vs. TEMPERATURE11 EMISSIONS LIMITS §24.23813 CONDUCTED SPURIOUS EMISSIONS22 BLOCK EDGE COMPLIANCE FOR BLOCK A AND C29 OCCUPIED BANDWIDTH §2.98931 CONDUCTED EMISSIONS § 15.107/20738 TEST EQUIPMENT AND ANCILLARIES USED FOR TESTS75 PICTURES77 CETECOM ICT Services GmbH Test report no..: 4-0902-19-04/03Issue Date: 2003-12-01Page 8 (91) REFERENCE NUMBER(S) OF TEST EQUIPMENT USED (for reference numbers see test equipment listing) 64 POWER OUTPUT SUBCLAUSE § 24.232 Summary: This paragraph contains both average , peak output powers and EIRP measurements for the mobile station. In all cases, the peak output power is within the required mask (this mask is specified in the JTC standards, TIA PN3389 Vol. 1 Chap 7, and is no FCC requirement). Method of Measurements: The mobile was set up for the max. output power with pseudo random data modulation. The power was measured with R&S Signal Analyzer FSIQ …
Text truncated - open the document above for the full version.
CETECOM ICT Services GmbH Test report no..: 4-0902-19-04/03Issue Date: 2003-10-15Page 77 (91) PICTURES Radiated Emissions CETECOM ICT Services GmbH Test report no..: 4-0902-19-04/03Issue Date: 2003-10-15Page 78 (91) Test site CETECOM ICT Services GmbH Test report no..: 4-0902-19-04/03Issue Date: 2003-10-15Page 79 (91) conducted measurements
2, rue du Petit Albi · CERGY PONTOISE CEDEX · France
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 24E | 1.85 GHz - 1.91 GHz | 678.00 mW | 300KGXW | 0.0117000000 ppm |

COSY Phone 3G
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
COSY Phone 2G
Equipment Class
PCE - PCS Licensed Transmitter held to ear
Handheld Top Up Terminal
Equipment Class
PCT - PCS Licensed Transmitter worn on body
Mobile phone
Equipment Class
PCE - PCS Licensed Transmitter held to ear
Network Measurement Device
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral