FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Sagem Wireless/
  3. M9HB2005BO

M9HB2005BOGSM 900/1800/1900 Mobile Phone with BT

Sagem Wireless
GSM 900/1800/1900 Mobile Phone with BT - FCC ID M9HB2005BO - Sagem Wireless
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Nov 27, 2005
Application Purpose
Original Equipment
Date of Application
Nov 27, 2005
Equipment Note
GSM 900/1800/1900 Mobile Phone with BT
Frequency Range
1850.20000000 - 1909.80000000
Company
Sagem Wireless
Country
France

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ENGLISH 250000000_my300X-301X-302X_lu_en.book Page 1 Mercredi, 23. novembre 2005 1:01 13 250000000_my300X-301X-302X_lu_en.book Page 2 Mercredi, 23. novembre 2005 12:55 12 3 You have just purchased a SAGEM phone, we congratulate you; it is recommended that you read this handbook carefully in order to use your phone efficiently and in the best conditions.Your phone can be used internationally in the various networks (GSM 900 MHz and DCS 1800 MHz (my300X model),GSM 900 MHz, DCS 1800 MHz or PCS 1900 MHz (my301X/my302X models)) depending on the roaming arrangements withyour operator.We remind you that this phone is approved to meet European standards.WARNINGDepending on the model, network configuration and associated subscription cards, certain functions may not be available.Ensure that your SIM card is a 3 V SIM type that is compatible with your phone. Inserting an incompatible card will be indicate d by a message when your phone is switched on. Contact your operator.Your phone is identified by its IMEI number. Write this number down, and do not keep it with your phone, because you maybe asked for it in the event of your phone being stolen, in order to prevent it from being used, even with a different SIM card . In order to display the IMEI on your phone's screen, type: *#06#.SAGEM™ is a trademark of SAFRAN.AT® is a registered trademark of Hayes Microcomputer Products Inc.Hayes® is a registered trademark of Hayes Microcomputer Products Inc.T9 is protected by one or more of the following US patents: 5,818,437,5,953,541, 5,187,480, 5,945,928, 6,011,554 and other patents are being applied for worldwide.Java™ and all Java™ based trademarks and logos are trademarks or registered trademarks of Sun Microsystems, Inc. in theU.S. and other countries.The WAP navigator and the softwares included are the exclusive property of Openwave. For this reason, it is forbidden tomodify, translate, disassemble or even decompile all or part of these softwares.© 2003 GAMELOFT® - All rights reserved - GAMELOFT® is a registered trademark of GAMELOFT S.A. - All rights reserved.Wellphone™ and SmartCom™ are registered trademarks owned by SmartCom SARL France. 250000000_my300X-301X-302X_lu_en.book Page 3 Mercredi, 23. novembre 2005 12:55 12 4 Conformance Document Conformance Document 250000000_my300X-301X-302X_lu_en.book Page 4 Mercredi, 23. novembre 2005 12:55 12 Safety Information for Wireless handled phones 5 Safety Information for Wireless handled phonesUse of your phone is subject to safety rules desi gned to protect the user and his or her environment. Exposure to Radio Frequency Signals- Your wireless handheld portable phone is a low power radio transmitter and receiver. When it is ON, it receives and alsosends out frequency (RF) signals. - In August, 1996, the Federal Communications Commissions (FCC) adopted RF exposure guidelines with safety levels forhandheld wireless phones. Those guidelines are consistent with the safety standards previously set by both U.S. and international standards bodies:ANSI C95.1 (1992) * NCPR Report 86 (1986) (*)ICNIRP (1996) (*). - Those standards were based on comprehensive and periodic evaluat ions of the relevant scientific literature. For example, over 120 scientists, engineers, and physicians from universities, government health agencies, and industry reviewed theavailable body of research to develop the ANSI Standard (C95.1). - The design of your phone complies with the FCC guidelines (and those standards). - For body worn operation, this phone has been tested and meets FCC RF exposure guidelines when used with anaccessory that contains no metal and that positions the handset a minimum of 2.5 cm from the body. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. Phone Operation- Normal position: hold the phone as you would any other phone with the upper zone (back of the LCD display) pointed upand over your shoulder. - Tips on efficient operation: for your phone to operate most efficiently: do not touch cover unnecessarily the top part of thephone with your hand. This would cover the integrated antenna and affect call quality and may cause the phone to operateat a higher power level than otherwise needed. *. American National Standards Institute; National Council on Radiation Protection and Measurements; International Commission and Non-Ionizing Radiation Protection. 250000000_my300X-301X-302X_lu_en.book Page 5 Mercredi, 23. novembre 2005 12:55 12 6 Safety Information for Wireless handled phones Driving- Check the laws and regulations on the use of wireless phones in the areas where you drive. Always obey them. Also, if using your phone while driving while driving please:• Give full attention of driving, driving safely is your first responsibility • Use hands-free operation, if available • Pull off the road and park before making or answering a call if driving conditions so require. Electronic Devices- Most modern electronic equipment is shielded from RF signals. However, certain electronic equipment may not beshielded against the RF signals from your wireless phone. - Some phone accessories allow to reduce the radiation inte rferences of the phone. Please contact your distributor. PacemakersThe Health Industry Manufacturers Association recommends that a minimum separation of six (6”) inches be maintainedbetween a handheld wireless phone and a pacemaker to avoid potential interference with the pacemaker. These recommendations are consistent with the independent research by and recommendations of Wireless Technology Research.Persons with pacemakers:- Should ALWAYS keep the phone more than six inches from their pacemaker when the phone is turned ON - Should not carry the phone in the breast pocket - Should use the ear opposite to the pacemaker to minimize the potential for interference - If you have any reason to suspect that interference is taking place, turn your phone OFF immediately. Hearing AidsSome digital wireless phones may interfere with so…

Text truncated - open the document above for the full version.

External Photos

CETECOM ICT Services GmbH UntertĂĽrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 4-1607-20-06/05 Date: 2005-08-23 Page 51 of 65 7 Annex C: External Photographs of the Equipment Photo 1: CETECOM ICT Services GmbH UntertĂĽrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 4-1607-20-06/05 Date: 2005-08-23 Page 52 of 65 Photo 2: CETECOM ICT Services GmbH UntertĂĽrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 4-1607-20-06/05 Date: 2005-08-23 Page 53 of 65 Photo 3: CETECOM ICT Services GmbH UntertĂĽrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 4-1607-20-06/05 Date: 2005-08-23 Page 54 of 65 Photo 4: CETECOM ICT Services GmbH UntertĂĽrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 4-1607-20-06/05 Date: 2005-08-23 Page 55 of 65 Photo 5:

ID Label/Location Info

TELEPHONIE MOBILE MOBILE PHONES Date : 12/09/05 Document Sagem Communication Reproduction et divulgation interdites 6/10 2. LABEL 2.1 LABEL LOCATION (ON ALL PRODUCTS) TELEPHONIE MOBILE MOBILE PHONES Date : 12/09/05 Document Sagem Communication Reproduction et divulgation interdites 8/10 2.2.2 Product B2005+ Outdoor Type of equipment : Triple Band GSM Mobile Phone (GSM900 / DCS1800 / PCS1900 MHz) GPRS : Class 10 Type designation : B2005+ Hardware Version : V0x Software Version : L 5,4G FCC ID : M9HB2005BO FCC Reg. Number : 0006-7315-09

Internal Photos

CETECOM ICT Services GmbH UntertĂĽrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 4-1607-20-06/05 Date: 2005-08-23 Page 56 of 65 8 Annex D: Internal Photographs of the Equipment Photo No.: 1 CETECOM ICT Services GmbH UntertĂĽrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 4-1607-20-06/05 Date: 2005-08-23 Page 57 of 65 Photo No.: 2 CETECOM ICT Services GmbH UntertĂĽrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 4-1607-20-06/05 Date: 2005-08-23 Page 58 of 65 Photo No.: 3 CETECOM ICT Services GmbH UntertĂĽrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 4-1607-20-06/05 Date: 2005-08-23 Page 59 of 65 Photo No.: 4 CETECOM ICT Services GmbH UntertĂĽrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 4-1607-20-06/05 Date: 2005-08-23 Page 60 of 65 Photo No.: 5 CETECOM ICT Services GmbH UntertĂĽrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 4-1607-20-06/05 Date: 2005-08-23 Page 61 of 65 Photo No.: 6 CETECOM ICT Services GmbH UntertĂĽrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 4-1607-20-06/05 Date: 2005-08-23 Page 62 of 65 Photo No.: 7 CETECOM ICT Services GmbH UntertĂĽrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 4-1607-20-06/05 Date: 2005-08-23 Page 63 of 65 Photo No.: 8 CETECOM ICT Services GmbH UntertĂĽrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 4-1607-20-06/05 Date: 2005-08-23 Page 64 of 65 Photo No.: 9 CETECOM ICT Services GmbH UntertĂĽrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 4-1607-20-06/05 Date: 2005-08-23 Page 65 of 65 Photo No.: 10

RF Exposure Info

CETECOM ICT Services GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken, Germany Phone: +49 (0) 681 598-0 Fax: -8475 SAR-Laboratory Phone: +49 (0) 681 598-8454 . As of 2005-09-23 Page 1 of 29 Accredited testing laboratory DAR registration number: DAT-P-176/94-D1 Federal Motor Transport Authority (KBA) DAR registration number: KBA-P 00070-97 Appendix to test report 4-1607-20-04/05-C Calibration data, Phantom certificate and detail information of the DASY4 System CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 4-1607-20-04/05-C As of 2005-09-23 Page 2 of 29 Table of Content 1 Calibration report “Probe ET3DV6” .................................................................................................................................... 3 2 Calibration report “1900 MHz System validation dipole .................................................................................................. 12 3 Calibration certificate of Data Aquisition Unit (DAE) ...................................................................................................... 21 4 Certificate of “SAM Twin Phantom V4.0/V4.0C” ........................................................................................................... 22 5 Application Note System Performance Check ................................................................................................................... 24 2005-09-23 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 4-1607-20-04/05-C As of 2005-09-23 Page 3 of 29 1 Calibration report “Probe ET3DV6” CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 4-1607-20-04/05-C As of 2005-09-23 Page 4 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 4-1607-20-04/05-C As of 2005-09-23 Page 5 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 4-1607-20-04/05-C As of 2005-09-23 Page 6 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 4-1607-20-04/05-C As of 2005-09-23 Page 7 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 4-1607-20-04/05-C As of 2005-09-23 Page 8 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 4-1607-20-04/05-C As of 2005-09-23 Page 9 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 4-1607-20-04/05-C As of 2005-09-23 Page 10 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 4-1607-20-04/05-C As of 2005-09-23 Page 11 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 4-1607-20-04/05-C As of 2005-09-23 Page 12 of 29 2 Calibration report “1900 MHz System validation dipole CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 4-1607-20-04/05-C As of 2005-09-23 Page 13 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 4-1607-20-04/05-C As of 2005-09-23 Page 14 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 4-1607-20-04/05-C As of 2005-09-23 Page 15 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 4-1607-20-04/05-C As of 2005-09-23 Page 16 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 4-1607-20-04/05-C As of 2005-09-23 Page 17 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 4-1607-20-04/05-C As of 2005-09-23 Page 18 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 4-1607-20-04/05-C As of 2005-09-23 Page 19 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 4-1607-20-04/05-C As of 2005-09-23 Page 20 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 4-1607-20-04/05-C As of 2005-09-23 Page 21 of 29 3 Calibration certificate of Data Aquisition Unit (DAE) CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 4-1607-20-04/05-C As of 2005-09-23 Page 22 of 29 4 Certificate of “SAM Twin Phantom V4.0/V4.0C” CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 4-1607-20-04/05-C As of 2005-09-23 Page 23 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 4-1607-20-04/05-C As of 2005-09-23 Page 24 of 29 5 Application Note System Performance Check 5.1.1.1 Purpose of system performance check The system performance check verifies that the system operates within its specifica-tions. System and operator errors can be detected and corrected. It is recommended that the system performance check is performed prior to any usage of the system in order to guarantee reproducible results. The measurement of the Specific Absorption Rate (SAR) is a complicated task and the result depends on the proper functioning of many components and the correct settings of many param-eters. Faulty results due to drift, failures or incorrect parameters might not be recognized, since they often look similar in distribution to the correct ones. The Dosimetric Assessment System DASY4 incorporates a system performance check procedure to test the proper functioning of the system. The system performance check uses normal SAR measurements in a simplified setup (the at section of the SAM Twin Phantom) with a well characterized source (a matched dipole at a specified distance). This setup was selected to give a high sensitivity to all parameters that might fail or vary over time (e.g., probe, liquid parameters, and software settings) and a low sensitivity to external effects inherent in the system (e.g., positioning uncertainty of the device holder). The system performance check does not replac…

Text truncated - open the document above for the full version.

RF Exposure Info

CETECOM ICT Services GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken, Germany Phone: +49 (0) 681 598-0 Fax: -8475 SAR-Laboratory Phone: +49 (0) 681 598-8454 . As of 2005-09-23 Page 1 of 60 Accredited testing laboratory DAR registration number: DAT-P-176/94-D1 Federal Motor Transport Authority (KBA) DAR registration number: KBA-P 00070-97 Test report no. : 4-1607-20-04/05-C Type identification : B2005+ Outdoor Test specification : IEEE P1528/D1.2 FCC-ID : M9HB2005BO Test specification : CETECOM ICT Services GmbH Test report no.: 4-1607-20-04/05-C As of 2005-09-23 Page 2 of 60 Table of Contents 1 General Information............................................................................................................................................................... 3 1.1 Notes ............................................................................................................................................................................... 3 1.1.1 Statement of Compliance ....................................................................................................................................... 3 1.2 Testing laboratory............................................................................................................................................................ 4 1.3 Details of applicant.......................................................................................................................................................... 4 1.4 Application details........................................................................................................................................................... 4 1.5 Test item .......................................................................................................................................................................... 5 1.6 Test specification(s) ........................................................................................................................................................ 6 1.6.1 RF exposure limits ................................................................................................................................................. 6 2 Technical test ......................................................................................................................................................................... 7 2.1 Summary of test results ................................................................................................................................................... 7 2.2 Test environment ............................................................................................................................................................. 7 2.3 Measurement and test set-up ........................................................................................................................................... 7 2.4 Measurement system ....................................................................................................................................................... 8 2.4.1 System Description ................................................................................................................................................ 8 2.4.2 Test environment ................................................................................................................................................... 9 2.4.3 Probe description ................................................................................................................................................... 9 2.4.4 Phantom description ............................................................................................................................................ 10 2.4.5 Device holder description .................................................................................................................................... 10 2.4.6 Scanning procedure.............................................................................................................................................. 11 2.4.7 Spatial Peak SAR Evaluation............................................................................................................................... 12 2.4.8 Data Storage and Evaluation................................................................................................................................ 13 2.4.9 Test equipment utilized........................................................................................................................................ 15 2.4.10 Tissue simulating liquids: dielectric properties.................................................................................................... 16 2.4.11 Tissue simulating liquids: parameters.................................................................................................................. 17 2.4.12 Measurement uncertainty evaluation for SAR test .............................................................................................. 18 2.4.13 Measurement uncertainty evaluation for system validation................................................................................. 19 2.4.14 System validation................................................................................................................................................. 20 2.4.15 Validation procedure............................................................................................................................................ 21 2.5 Test results (Head and Body SAR)................................................................................................................................ 22 2.5.1 Description of test procedures ............................................................................................................................. 22 2.6 Test results (conducted power measurement)...…

Text truncated - open the document above for the full version.

Test Report

CETECOM ICT Services GmbH UntertĂĽrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 4-1607-18-06/05 Date: 2005-08-18 Page 1 of 46 Recognized by the Federal Communications Commission Anechoic chamber registration no.: 90462 (FCC) Anechoic chamber registration no.: 3463 (IC) TCB ID: BE 0012 Accredited by the German Accreditation Council DAR–Registration Number DAT-P-176/94-D1 Independent ETSI compliance test house ETSI Accredited Bluetooth ® Test Facility (BQTF) Test report no. : 4-1607-18-06/05 Applicant : Sagem Communication Type : B2005+ Test Standard : FCC Part 24 RSS133 FCC ID : M9HB2005B Certification No. IC : --- CETECOM ICT Services GmbH UntertĂĽrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 4-1607-18-06/05 Date: 2005-08-18 Page 2 of 46 Table of contents 1 GENERAL INFORMATION ................................................................................................................................... 3 1.1. ADMINISTRATIVE DATA OF THE TEST FACILITY..................................................................................................... 3 1.1.1 Identification of the testing laboratory ......................................................................................................... 3 1.2. NOTES................................................................................................................................................................... 3 1.3 DETAILS OF APPLICANT......................................................................................................................................... 4 1.4 APPLICATION DETAILS.......................................................................................................................................... 4 1.5 TEST ITEM............................................................................................................................................................. 5 1.6 TEST SETUP........................................................................................................................................................... 6 1.7 TEST STANDARDS.................................................................................................................................................. 6 2 STATEMENT OF COMPLIANCE .......................................................................................................................... 7 2.1 SUMMARY OF MEASUREMENT RESULTS................................................................................................................ 7 2.1.1 PCS 1900 ...................................................................................................................................................... 7 3 MEASUREMENTS AND RESULTS ....................................................................................................................... 8 3.1 PART PCS 1900 ................................................................................................................................................... 8 3.1.1 RF Power Output .......................................................................................................................................... 8 3.1.2 Frequency Stability..................................................................................................................................... 12 3.1.3 Radiated Emissions..................................................................................................................................... 15 3.1.4 Receiver Radiated Emissions ...................................................................................................................... 25 3.1.6 Block Edge Compliance .............................................................................................................................. 33 3.1.7 Occupied Bandwidth................................................................................................................................... 36 4 USED TESTEQUIPMENT ...................................................................................................................................... 43 CETECOM ICT Services GmbH UntertĂĽrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 4-1607-18-06/05 Date: 2005-08-18 Page 3 of 46 1 General information 1.1. Administrative data of the test facility 1.1.1 Identification of the testing laboratory Company name: Cetecom ICT Services GmbH Address: UntertĂĽrkheimerstr. 6-10 D-66117 Saarbruecken Germany Laboratory accreditation: DAR-Registration No. DAT-P-176/94-D1 Bluetooth Qualification Test Facility (BQTF) Federal Communications Commission (FCC) Identification/Registration No : 90462 Responsible for testing laboratory: Gillmann D. / Hausknecht D. Phone: +49 681 598 0 Fax: +49 681 598 9075 email: [email protected] 1.2. Notes The test results of this test report relate exclusively to the test item specified in 1.5. The CETECOM ICT Services GmbH does not assume responsibility for any conclusions and generalizations drawn from the test results with regard to other specimens or samples of the type of the equipment represented by the test item. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of the CETECOM ICT Services GmbH. .......................................... / ........................................... Responsible for testing laboratory (Gillmann D. / Hausknecht D.) .......................................... / ........................................... Responsible for test report (Gillmann D. / Hausknecht D.) CETECOM ICT Services GmbH UntertĂĽrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49…

Text truncated - open the document above for the full version.

Test Report

CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 4-1607-20-06/05 Date: 2005-08-23 Page 1 of 35 Recognized by the Federal Communications Commission Anechoic chamber registration no.: 90462 (FCC) Anechoic chamber registration no.: 3463 (IC) TCB ID: BE 0012 Accredited by the German Accreditation Council DAR–Registration Number DAT-P-176/94-D1 Independent ETSI compliance test house ETSI Accredited Bluetooth ® Test Facility (BQTF) Test report No. : 4-1607-20-06/05 Applicant : Sagem Communication Type : B2005+ Outdoor Test Standard : FCC Part 24 RSS 133 FCC ID : M9HB2005BO Certification No. IC : --- CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report No.: 4-1607-20-06/05 Date: 2005-08-23 Page 2 of 35 Table of contents 1 GENERAL INFORMATION ................................................................................................................................... 3 1.1. ADMINISTRATIVE DATA OF THE TEST FACILITY..................................................................................................... 3 1.1.1 Identification of the testing laboratory ......................................................................................................... 3 1.2. NOTES................................................................................................................................................................... 3 1.3 DETAILS OF APPLICANT................................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Francois CHAMBON(GM)
[email protected]86-574-2796-0448Fax: 86-574-2796-0997

Test Firm

cetecom advanced GmbHGerald Schmidt
[email protected]49-681-598-0Fax: 49-681-598-8775

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
124E1.85 GHz - 1.91 GHz1.096 W300KGXW0.0282000000 ppm
Confidentiality
Long Term
Grant Notes
Power listed is EIRP. This filing is only applicable for GSM 1900 MHz and 2.4 GHz Bluetooth operations. This device contains 900/1800 MHz GSM functions that are not operational in U.S. Territories. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and which provide at least 25 mm separation between the device and the users body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. Highest reported SAR values are: Head: 0.808 W/kg, Body 0.534 W/kg

Other Applications from Sagem Wireless

COSY Phone 3G - FCC ID M9HCOSY3G - Sagem Wireless
M9HCOSY3G

COSY Phone 3G

Oct 13, 2010

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
COSY Phone 2G - FCC ID M9HCOSY2G - Sagem Wireless
M9HCOSY2G

COSY Phone 2G

Sep 06, 2010

Equipment Class

PCE - PCS Licensed Transmitter held to ear
Handheld Top Up Terminal - FCC ID M9HMOV001 - Sagem Wireless
M9HMOV001

Handheld Top Up Terminal

Aug 18, 2010

Equipment Class

PCT - PCS Licensed Transmitter worn on body
Mobile phone - FCC ID M9HPM1 - Sagem Wireless
M9HPM1

Mobile phone

Apr 26, 2010

Equipment Class

PCE - PCS Licensed Transmitter held to ear
Network Measurement Device - FCC ID M9HOT8X0RF - Sagem Wireless
M9HOT8X0RF

Network Measurement Device

Jan 31, 2010

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral