FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Midland Radio Corporation/
  3. MMAGXT5000

MMAGXT500022 Channel GMRS/FRS Portable Transceiver

Midland Radio Corporation
22 Channel GMRS/FRS Portable Transceiver - FCC ID MMAGXT5000 - Midland Radio Corporation
Click to zoom

Application Details

Equipment Class
FRF - Part 95 Family Radio Face Held Transmitter
Date of Grant
Sep 09, 2010
Application Purpose
Original Equipment
Date of Application
Sep 09, 2010
Equipment Note
22 Channel GMRS/FRS Portable Transceiver
Frequency Range
462.55000000 - 462.72500000
Company
Midland Radio Corporation
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Model GXT5000 Series Page 3www.midlandradio.com TABLE OF CONTENTS3 Introduction4 Important Notice, FCC Licensing5 LCD Display6 Controls6 Battery Installation7 Installing the Belt Clip7 Charging the Battery Pack8 Low Battery Level Indicator8 Operating Your Radio9 - 15 External Speaker/Microphone Jack15 Troubleshooting Guide16 Use and Care16 Specifications and Frequency Charts17 - 18 Warranty Information19 MIDLAND Family Products20 Accessories21-22 Accessories Order Form23 Page 4www.midlandradio.com Welcome to the world of Midland electronics Congratulations on your purchase of a high quality MIDLAND product. Your 2-way radio represents the state-of-the-art in high-tech engineering. Designed for GMRS (General Mobile Radio Service) operation, this compact package is big in performance. It is a quality piece of electronic equipment, skillfully constructed with the finest components. The circuitry is all solid-state and mounted on a rugged printed circuit board. Your two-way radio is designed for reliable and trouble-free performance for years to come. Features - 22 GMRS/FRS Channel - 121 Privacy Codes (38 CTCSS / 83 DCS) - Waterproof IP67* Standard - VOX - Selectable Call Alert - Dual Watch - Time-Out Timer - Out-of-Range Alert - Monitor Function - Roger Beep Tone - Silent Operation - Keypad Lock - Channel Scan Function - SOS Siren - Power HI/LO Settings - Auto Squelch - Speaker / Microphone Jacks - Battery Meter / Battery Low Indicator * Ingress of water in harmful quantity shall not be possible when the enclosure is immersed in water (up to 1 m of submersion for 30 minutes) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions : (1) this device does not cause harmful interference, and (2) this radio must accept any interference that may cause undesired operation. To maintain compliance with FCC’s RF exposure guidelines, for body-worn operation, this radio has been tested and meets the FCC RF exposure guidelines when used with Midland Radio Corp. accessories supplied or designated for this product. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. (Tested with Headset Model: AVP-1) Model GXT5000 Series Page 5www.midlandradio.com IMPORTANT NOTICE, FCC LICENSE REQUIRED FOR GMRS OPERATION The GXT5000 Series operates on GMRS (General Mobile Radio Service) frequencies which require an FCC (Federal Communications Commission) license. You must be licensed prior to operating on channels 1 - 7 or 15 - 22, which comprise the GMRS channels of the GXT5000 Series. Serious penalties could result for unlicensed use of GMRS channels, in violation of FCC rules, as stipulated in the Communications Act's Sections 501 and 502 (amended). You will be issued a call sign by the FCC which should be used for station identification when operating the radio on GMRS channels. You should also cooperate by engaging in permissible transmissions only, avoiding channel interference with other GMRS users, and being prudent with the length of their transmission time. To obtain a license or ask questions about the license application, contact the FCC at 1-888-CALL FCC or go to the FCC's website: http://www .fcc.govand request form 605. Exposure To Radio Frequency Energy Your Midland radio is designed to comply with the following national and international standards and guidelines regarding exposure of human being to radio frequency electromagnetic energy: - United States Federal Communications Commission, Code of Federal Regulations: 47 CFR part 2 sub-part J - American National Standards Institute (ANSI)/Institute of Electrical & Electronic Engineers (IEEE) C95. 1-1992 - Institute of Electrical and Electronic Engineer (IEEE) C95. 1-1999 Edition - National Council on Radiation Protection and Measurements (NCRP) of the United States, Report 86, 1986 - International Commission on Non-lonizing Radiation Protection (ICNIRP) 1998 To control your exposure and ensure compliance with the general population or uncontrolled environment exposure limits, transmit no more than 50% of the time. The radio generates measurable RF energy exposure only when transmitting. Model GXT5000 Series IMPORTANT:Changes or modifications to this unit not expressly approved by MIDLAND RADIO CORP. could void your right to operate this unit. Your radio is set up to transmit a regulated signal on an assigned frequency. It is against the law to alter or adjust the settings inside the COMMUNICATOR to exceed those limitations. Any adjustment to your radio must be made by qualified technicians. Page 6www.midlandradio.com CONTROLS LCD DISPLA Y 1. BATTERY METER– Indicates the battery level. 2. SIGNAL STRENGTH METER – Indicates the transmit and receive signal strength. 3. DUAL WATCH ICON – Indicates the Dual Watch function is on. 4. KEY LOCK ICON – Indicates KEY LOCK mode is on. 5. CHANNEL NUMBER– Changes from 1~22 on GMRS/FRS band. 6. VOX ICON– Indicates when VOX mode is active. 7. CHANNEL SCAN ICON– Indicates when the Channel Scan function is on. 8. ROGER BEEP ICON– Indicates when the Roger Beep function is on. 9. CTCSS ICON– Indicates the radio is set with a CTCSS Privacy Code. 10. DCS ICON– Indicates the radio is set with a DCS Privacy Code. 11. PRIVACY CODE– Indicates Privacy Code selected by user (oF~38/oF~83). 12. TRANSMIT POWER LEVEL LO ICON– Indicates TX Power is at Lo setting. 13. ANTENNA 14. SOS Siren Button– Press and hold to turn on the Siren. 15. PTT Button– Press and hold to transmit voice communication. 16. MONITOR Button– Press and hold to enter MONITOR mode. 17. CALL Button– Press to send a CALL Alert signal. 18. SPEAKER– Built-in speaker. 19. POWER/VOLUME KNOB– Turn clockwise to turn the power on and increase the volume level. Turn counter-clockwise to decrease the volume level and turn the power off. 20. TRANSMIT (TX)/RECEIVE (RX) LED Indicator– Indicates RED when the radio is in TX mode. Indicates GREEN when the radio is receiving the correct Channel and Privacy C…

Text truncated - open the document above for the full version.

Cover Letter(s)

5900 Parretta Drive â—Ź KANSAS CITY, MISSOURI â—Ź 64120 TELEPHONE: (816) 241-8500 â—Ź FAX: (816) 241-5713 EMAIL: [email protected] WEBSITE: www.midlandradio.com FCC Confidential Authorization July 22, 2010 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: MMAGXT5000. In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Midland Radio Corporation. hereby requests long-term confidential treatment of information accompanying this application as outlined below: • Block Diagram • Schematics • Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely, David Kingsolver, Director of Engineering Midland Radio Corporation 5900 Parretta Drive Kansas City, MO 64120 (816) 241-8500 (ext 237)

External Photos

Midland Radio Corporation FCC ID: MMAGXT5000 Report Number: R1008022-95 Page 31 of 37 FCC Part 95 Test Report 12 EXHIBIT C - EUT Photographs 12.1 EUT Top View 1 12.2 EUT Top View 2 Midland Radio Corporation FCC ID: MMAGXT5000 Report Number: R1008022-95 Page 32 of 37 FCC Part 95 Test Report 12.3 EUT Bottom View 12.4 EUT Bottom View (Battery off) Midland Radio Corporation FCC ID: MMAGXT5000 Report Number: R1008022-95 Page 33 of 37 FCC Part 95 Test Report 12.5 EUT Side View 1 12.6 EUT Side View 2 Midland Radio Corporation FCC ID: MMAGXT5000 Report Number: R1008022-95 Page 34 of 37 FCC Part 95 Test Report 12.7 EUT Battery View 12.8 EUT Charger Top View Midland Radio Corporation FCC ID: MMAGXT5000 Report Number: R1008022-95 Page 35 of 37 FCC Part 95 Test Report 12.9 EUT Charger Bottom View 12.10 EUT AC Adapter View

Internal Photos

Midland Radio Corporation FCC ID: MMAGXT5000 Report Number: R1008022-95 Page 36 of 37 FCC Part 95 Test Report 12.11 EUT Interior PCB Top View 1 12.12 EUT Interior PCB Top View 2 Midland Radio Corporation FCC ID: MMAGXT5000 Report Number: R1008022-95 Page 37 of 37 FCC Part 95 Test Report 12.13 EUT Interior PCB Bottom View ***** END OF REPORT *****

RF Exposure Info

Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP*, NIST, or any agency of the Federal Government. * This report may contain data that are not covered by the NVLAP accreditation and are marked with an asterisk “*" (Rev.2) SAR EVALUATION REPORT For Midland Radio Corporation 5900 Parretta Drive, Kansas City, MO 64120, USA FCC ID: MMAGXT5000 Report Type: Original Report Product Type: GMRS/FRS Radio Test Engineer: Arthur Tie Report Number: R1008022-SAR Report Date: 2010-09-08 Reviewed By: Victor Zhang Test Engineer, RF Lead Prepared By: (84) Bay Area Compliance Laboratories Corp. (BACL) 1274 Anvilwood Avenue, Sunnyvale, CA 94089, USA Tel: (408) 732-9162 Fax: (408) 732 9164 Midland Radio Corporation FCC ID: MMAGXT5000 Report Number: R1008022-SAR SAR Evaluation Report Page 2 of 49 SAR Evaluation Results Rule Part(s): CFR 47 §2.1093 Test Procedure(s): FCC OET Bulletin 65 C; IEEE 1528-2003 Exposure Category: Occupational/Controlled Exposure Device Type: GMRS/FRS radio Modulation Type: FM TX Frequency Range: FRS: 462.5625~467.7125 MHz GMRS: 462.5625~462.7125 MHz 462.5500~462.7250 MHz Maximum Conducted Power Tested: 36.72 dBm Antenna Type(s) Tested: External Antenna Body-Worn Accessories: Belt Clip Face-Head Accessories: None Battery Type (s) Tested: 7.4 Vdc Rechargeable Li-On Battery Max. SAR Level(s) Measured: Body-Worn: 0.920 W/Kg (1g Body Tissue) Face-Hold: 0.705 W/Kg (1g Head Tissue) (with 50% duty cycle) This wireless device has been shown to be capable of compliance for localized specific absorption rate (SAR) for General Population/Uncontrolled Exposure limits specified in ANSI/IEEE Standards and has been tested in accordance with the measurement procedures specified in FCC OET 65 Supplement C. The results and statements contained in this report pertain only to the device(s) evaluated. EUT Photo Midland Radio Corporation FCC ID: MMAGXT5000 Report Number: R1008022-SAR SAR Evaluation Report Page 3 of 49 TABLE OF CONTENTS REFERENCE, STANDARDS AND GUILDELINES..................................................................................................... 5 SAR LIMITS......................................................................................................................................................................... 6 EUT DESCRIPTION......................................................................................................................................................... 7 FACILITIES AND ACCREDITATION .......................................................................................................................... 8 DESCRIPTION OF TEST SYSTEM ............................................................................................................................... 9 MEASUREMENT SYSTEM DIAGRAM.................................................................................................................................... 11 SYSTEM COMPONENTS....................................................................................................................................................... 12 DASY4 MEASUREMENT SERVER....................................................................................................................................... 12 DATA ACQUISITION ELECTRONICS..................................................................................................................................... 13 PROBES.............................................................................................................................................................................. 13 TESTING EQUIPMENT ................................................................................................................................................ 20 EQUIPMENTS LIST & CALIBRATION INFO........................................................................................................................... 20 SAR MEASUREMENT SYSTEM VERIFICATION................................................................................................... 21 SYSTEM ACCURACY VERIFICATION................................................................................................................................... 21 SAR MEASUREMENT RESULTS................................................................................................................................ 22 SAR TEST DATA................................................................................................................................................................ 22 APPENDIX A – MEASUREMENT UNCERTAINTY................................................................................................. 23 APPENDIX B – PROBE CALIBRATION CERTIFICATES...................................................................................... 24 APPENDIX C – DIPOLE CALIBRATION CERTIFICATES....................................................................................33 APPENDIX D - TEST SYSTEM VERIFICATIONS SCANS ..................................................................................... 38 LIQUID MEASUREMENT RESULT........................................................................................................................................ 38 APPENDIX E – EUT SCAN RESTLTS......................................................................................................................... 40 APPENDIX F – OUTPUT POWER MEASUREMENT .............................................................................................. 44 TEST BLOCK DIAGRAM AND PROCEDURE.......................................................................................................................... 44 TEST EQUIPMENT…

Text truncated - open the document above for the full version.

Test Report

Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP*, NIST, or any agency of the Federal Government. * This report may contain data that are not covered by the NVLAP accreditation and are marked with an asterisk “*” (Rev.2) FCC PART 95 TEST AND MEASUREMENT REPORT For Midland Radio Corporation 5900 Parretta Drive, Kansas City, MO 64120, USA Model: GXT5000 FCC ID: MMAGXT5000 Report Type: Original Report Product Type: FRS/GMRS Handheld 2-Way Radio Test Engineer: Jerry Huang Report Number: R1008022-95 Report Date: 2010-09-07 Reviewed By: Victor Zhang Test Engineer, RF Lead Prepared By: (84) Bay Area Compliance Laboratories Corp. (BACL) 1274 Anvilwood Avenue, Sunnyvale, CA 94089 Tel: (408) 732-9162 Fax: (408) 732 9164 Midland Radio Corporation FCC ID: MMAGXT5000 Report Number: R1008022-95 Page 2 of 37 FCC Part 95 Test Report TABLE OF CONTENTS 1. GENERAL INFORMATION............................................................................................................................... 5 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)........................................................................ 5 1.2 MECHANICAL DESCRIPTION........................................................................................................................... 5 1.3 OBJECTIVE...................................................................................................................................................... 5 1.4 RELATED SUBMITTAL(S)/GRANT(S) ............................................................................................................... 6 1.5 TEST METHODOLOGY..................................................................................................................................... 6 1.6 MEASUREMENT UNCERTAINTY...................................................................................................................... 6 1.7 TEST FACILITY............................................................................................................................................... 6 2 SYSTEM TEST CONFIGURATION ................................................................................................................. 7 2.1 JUSTIFICATION................................................................................................................................................ 7 2.2 EUT EXERCISE SOFTWARE............................................................................................................................. 7 2.3 SPECIAL EQUIPMENT...................................................................................................................................... 7 2.4 EQUIPMENT MODIFICATIONS.......................................................................................................................... 7 2.5 LOCAL SUPPORT EQUIPMENT LIST AND DETAILS........................................................................................... 7 2.6 INTERFACE PORTS AND CABLING................................................................................................................... 7 2.7 INTERNAL PCB ASSEMBLY LIST AND DETAILS.............................................................................................. 7 3 SUMMARY OF TEST RESULTS ...................................................................................................................... 8 4 FCC §2.1046 & §95.639 – RF OUTPUT POWER ............................................................................................. 9 4.1 APPLICABLE STANDARD................................................................................................................................. 9 4.2 TEST PROCEDURE AND BLOCK DIAGRAM....................................................................................................... 9 4.3 TEST EQUIPMENT LIST AND DETAILS............................................................................................................. 9 4.4 TEST ENVIRONMENTAL CONDITIONS.............................................................................................................. 9 4.5 TEST RESULTS.............................................................................................................................................. 10 5 FCC §2.1047 & §95.637 - MODULATION CHARACTERISTICS............................................................... 11 5.1 APPLICABLE STANDARD...............................................................................................................................11 5.2 TEST PROCEDURE AND BLOCK DIAGRAM..................................................................................................... 11 5.3 TEST EQUIPMENT LIST AND DETAILS........................................................................................................... 11 5.4 TEST ENVIRONMENTAL CONDITIONS............................................................................................................ 12 5.5 TEST RESULTS.............................................................................................................................................. 12 6 FCC §2.1049, §95.633 & §95.635 – OCCUPIED BANDWIDTH & EMISSION MASK ............................. 14 6.1 APPLICABLE STANDARDS............................................................................................................................. 14 6.2 TEST PROCEDURE AND BLOCK DIAGRAM..................................................................................................... 14 6.3 TEST EQUIPMENT LIST AND DETAILS........................................................................................................... 15 6.4 TEST ENVIRONME…

Text truncated - open the document above for the full version.

Test Setup Photos

Midland Radio Corporation FCC ID: MMAGXT5000 Report Number: R1008022-95 Page 29 of 37 FCC Part 95 Test Report 11 EXHIBIT B – Test Setup Photographs 11.1 Radiated Emissions below 1 GHz – Front View 11.2 Radiated Emissions below 1 GHz – Rear View Midland Radio Corporation FCC ID: MMAGXT5000 Report Number: R1008022-95 Page 30 of 37 FCC Part 95 Test Report 11.3 Radiated Emissions above 1 GHz – Front View 11.4 Radiated Emissions above 1 GHz – Rear View

Contact Information

Applicant

Butch Rittmann(Director of Operations)
[email protected]816 241-8500Fax: 816 241-5713

Test Firm

Bay Area Compliance LaboratoryJohn Chan
[email protected]408-732-9162Fax: 408-732-9164

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
395A462.55 MHz - 462.725 MHz3.972 W11K0F3E5 ppm
Confidentiality
Long Term
Grant Notes
Power Listed is ERP. This device is authorized to operate in the following radio services: FRS (Part 95B) or GMRS (Part 95A). There must be an informational insert inside the box (product package) or the User�s Manual must include information that clearly informs the consumer (buyer/owner) when the radio is transmitting on GMRS frequencies, that operation on GMRS frequencies requires an FCC license and such operation is subject to additional rules specified in 47 C.F.R. Part 95. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations. Hand held and Body-worn SAR compliance is limited to the specific antennas/belt-clips/holsters/accessories tested for this device. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device complies with OET Bulletin 65 for General Population use. The highest reported SAR levels are: Face-held: 0.705 W/Kg, Body-worn: 0.920 W/Kg with 50% Duty Cycle.

Other Applications from Midland Radio Corporation

Wireless Bluetooth Microphone - FCC ID MMAMXMC95 - Midland Radio Corporation
MMAMXMC95

Wireless Bluetooth Microphone

Jun 10, 2026

Equipment Class

JAB - Part 15 Class B Digital Device
GMRS Radio - FCC ID MMAMXT295 - Midland Radio Corporation
MMAMXT295

GMRS Radio

Jun 08, 2026

Equipment Class

TNF - Licensed Non-Broadcast Transmitter Held to Face
Transceiver - FCC ID MMACLIPTALK - Midland Radio Corporation
MMACLIPTALK

Transceiver

Apr 27, 2026

Equipment Class

DTS - Digital Transmission System
BUSINESS BAND TWO-WAY RADIO - FCC ID MMABR200S - Midland Radio Corporation
MMABR200S

BUSINESS BAND TWO-WAY RADIO

Jan 13, 2026

Equipment Class

TNF - Licensed Non-Broadcast Transmitter Held to Face
GMRS RADIO - FCC ID MMAGXT67 - Midland Radio Corporation
MMAGXT67

GMRS RADIO

Oct 29, 2023

Equipment Class

TNF - Licensed Non-Broadcast Transmitter Held to Face