Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
JAPAN QUALITY ASSURANCE ORGANIZATION 21-25, KINUTA 1-CHOME, SETAGAYA-KU, TOKYO 157-8573 JAPAN PHONE (03) 3416-0111, TELEX 242-2531 JQA J FAX (03) 3416-9691 JQA APPLICATION NO.: 400-90545 Issue Date : December 8, 1999 Page 1 of 17 EMI TEST REPORT JQA APPLICATION NO. : 400-90545 Model No. : D01SB Type of Equipment : Remote Keyless Entry System (Receiver) Regulations Applied : CFR 47 FCC Rules and Regulations Part 15 FCC ID : MOZD01RB Applicant : TOKAI RIKA CO., LTD. Address : 260, Toyota 3-chome, Oguchi-cho, Niwa-gun, Aichi-ken 480-0195, Japan Manufacture : TOKAI RIKA CO., LTD. Address : 260, Toyota 3-chome, Oguchi-cho, Niwa-gun, Aichi-ken 480-0195, Japan Final Judgment : Passed TEST RESULTS IN THIS REPORT are obtained in use of equipment that is traceable to Electrotechnical Lab. of MITI Japan and Communications Research Lab. of MPT Japan. The test results only respond to the tested sample. It is not allowed to copy this report even partly without the allowance of the JQA EMC Engineering Dept. Testing Div. COPY JQA Application No. :400-90545 FCC ID : MOZD01RB Model No. :D01SB Issue Date :December 8, 1999 Standard :CFR 47 FCC Rules Part 15 Page 2 of 17 JQA QUALITY ASSURANCE ORGANIZATION TABLE OF CONTENTS Page 1 Documentation 1.1 Test Regulation 3 1.2 General Information 3 1.3 Test Condition 4 โ 6 1.4 EUT Modifications 7 1.5 Test results / Uncertainty 8 1.6 Summary 9 1.7 Test Configuration / Operation of EUT 10 1.8 EUT Arrangement (Drawings) 11 1.9 Preliminary Test and Test-setup (Drawings) 12 โ 14 1.10 EUT Arrangement (Photographs) 15 2 Test Data 2.1 AC Power Line Conducted Emission 0.45 MHz โ 30 MHz N/A 2.2 Radiated Emission (Electric Field)30 MHz โ 1000 MHz 16 โ 17 COPY JQA Application No. :400-90545 FCC ID : MOZD01RB Model No. :D01SB Issue Date :December 8, 1999 Standard :CFR 47 FCC Rules Part 15 Page 3 of 17 JQA QUALITY ASSURANCE ORGANIZATION 1 DOCUMENTATION 1.1 TEST REGULATION FCC Rules and Regulations Part 15 Subpart A and B (June 23, 1989) Superregenerative Receiver Test procedure : AC power line conducted emission and radiated emission tests were performed according to the procedures in ANSI C63.4-1992. 1.2 GENERAL INFORMATION 1.2.1 Test facility : 1) Test Facility located at EMC Engineering Dept. Testing Div. : No.2 and 3 Anechoic Chambers( 3 meters Site ) FCC filing No. : 31040/SIT 1300F2 2) EMC Engineering Dept. Testing Div. is recognized under the National Voluntary Laboratory accreditation Program for satisfactory compliance established in title 15, Part 285 Code of Federal Regulations. NVLAP Lab Code : 200189-0 (Effective through : June 30, 2000) 1.2.2 Description of the Equipment Under Test (EUT) : 1) Type of Equipment : Remote Keyless Entry System(Receiver) 2) Product Type : Production 3) Category : Low Power Communication Device Receiver 4) EUT Authorization : Certification 5) FCC ID : MOZD01RB 6) Trade Name : TOKAI RIKA 7) Model No. : D01SB 8) Tuning Frequency Range : 315 MHz 9) Highest Frequency Used in the EUT : 304.3 10) Serial No. : - 11) Date of Manufacture : - 12) Power Rating : DC 12V 13) EUT Grounding : None 1.2.3 Definitions for symbols used in this test report : x - indicates that the listed condition, standard or equipment is applicable for this report. - indicates that the listed condition, standard or equipment is not applicable for this report. COPY JQA Application No. :400-90545 FCC ID : MOZD01RB Model No. :D01SB Issue Date :December 8, 1999 Standard :CFR 47 FCC Rules Part 15 Page 4 of 17 JQA QUALITY ASSURANCE ORGANIZATION 1.3 TEST CONDITION 1.3.1 The measurement of the AC Power Line Conducted Emission - was performed in the following test site. x - was not applicable. Test location : Safety Testing Center EMC Engineering Dept. Testing Div. 21-25, Kinuta 1-chome, Setagaya-ku, Tokyo 157-8573, Japan - Shielded Enclosure - Anechoic Chamber No. 2 (portable Type) Used test instruments : Type Model No. Manufacturer Serial No. Last Cal. Interval - Field Strength Meter ESH-2 Rohde & Schwarz 880370/016 May 1999 1 Year - Field Strength Meter ESH-3 Rohde & Schwarz 881460/016 May 1999 1 Year - Field Strength Meter ESH-3 Rohde & Schwarz 881460/030 Nov 1999 1 Year - LISN KNW-407 Kyoritsu Electrical 8-833-6 Apr. 1999 1 Year - LISN KNW-407 Kyoritsu Electrical 8-855-2 Apr. 1999 1 Year - LISN KNW-407 Kyoritsu Electrical 8-757-1 Apr. 1999 1 Year - RF Cable 3D-2W Fujikura 155-21-005 Apr. 1999 1 Year - RF Cable 3D-2W Fujikura 155-21-006 Apr. 1999 1 Year COPY JQA Application No. :400-90545 FCC ID : MOZD01RB Model No. :D01SB Issue Date :December 8, 1999 Standard :CFR 47 FCC Rules Part 15 Page 5 of 17 JQA QUALITY ASSURANCE ORGANIZATION 1.3.2 The measurement of the Radiated Emission(30 MHz โ 1000 MHz) x - was performed in the following test site. - was not applicable. Test location : Safety Testing Center EMC Engineering Dept. Testing Div. 21-25, Kinuta 1-chome, Setagaya-ku, Tokyo 157-8573, Japan x - Anechoic Chamber No. 2 (3 meters) - Anechoic Chamber No. 3 (3 meters) Validation of Site Attenuation : 1) Last Confirmed Date :March, 1999 2) Interval :1 year Used test instruments : Type Model No. Manufacturer Serial No. Last Cal. Interval - Field Strength Meter ESV Rohde & Schwarz 872148/039 May 1999 1 Year - Field Strength Meter ESVP Rohde & Schwarz 879783/030 May 1999 1 Year x - Field Strength Meter ESVP Rohde & Schwarz 881478/004 May 1999 1 Year - Field Strength Meter ESVP Rohde & Schwarz 881478/005 May 1999 1 Year - Antenna KBA-511A Kyoritsu Electrical 0-201-13 Nov. 1999 1 Year x - Antenna KBA-511A Kyoritsu Electrical 0-170-1 Nov. 1999 1 Year - Antenna KBA-611 Kyoritsu Electrical 0-210-5 Nov. 1999 1 Year x - Antenna KBA-611 Kyoritsu Electrical 0-147-14 Nov. 1999 1 Year x - RF Cable 5D-2W Fujikura 155-21-001 Feb. 1999 1 Year - RF Cable 5D-2W Fujikura 155-21-002 Feb. 1999 1 Year COPY JQA Application No. :400-90545 FCC ID : MOZD01RB Model No. :D01SB Issue Date :December 8, 1999 Standard :CFR 47 FCC Rules Part 15 Page 6 of 17 JQA QUALITY ASSURANCE ORGANIZATION 1.3.3 The measurement oโฆ
Text truncated - open the document above for the full version.
JAPAN QUALITY ASSURANCE ORGANIZATION 21-25, KINUTA 1-CHOME, SETAGAYA-KU, TOKYO 157-8573 JAPAN PHONE (03) 3416-0111, TELEX 242-2531 JQA J FAX (03) 3416-9691 JQA APPLICATION NO.: 400-90545 Issue Date : December 8, 1999 Page 1 of 17 EMI TEST REPORT JQA APPLICATION NO. : 400-90545 Model No. : D01SB Type of Equipment : Remote Keyless Entry System (Receiver) Regulations Applied : CFR 47 FCC Rules and Regulations Part 15 FCC ID : MOZD01RB Applicant : TOKAI RIKA CO., LTD. Address : 260, Toyota 3-chome, Oguchi-cho, Niwa-gun, Aichi-ken 480-0195, Japan Manufacture : TOKAI RIKA CO., LTD. Address : 260, Toyota 3-chome, Oguchi-cho, Niwa-gun, Aichi-ken 480-0195, Japan Final Judgment : Passed TEST RESULTS IN THIS REPORT are obtained in use of equipment that is traceable to Electrotechnical Lab. of MITI Japan and Communications Research Lab. of MPT Japan. The test results only respond to the tested sample. It is not allowed to copy this report even partly without the allowance of the JQA EMC Engineering Dept. Testing Div. COPY JQA Application No. :400-90545 FCC ID : MOZD01RB Model No. :D01SB Issue Date :December 8, 1999 Standard :CFR 47 FCC Rules Part 15 Page 2 of 17 JQA QUALITY ASSURANCE ORGANIZATION TABLE OF CONTENTS Page 1 Documentation 1.1 Test Regulation 3 1.2 General Information 3 1.3 Test Condition 4 โ 6 1.4 EUT Modifications 7 1.5 Test results / Uncertainty 8 1.6 Summary 9 1.7 Test Configuration / Operation of EUT 10 1.8 EUT Arrangement (Drawings) 11 1.9 Preliminary Test and Test-setup (Drawings) 12 โ 14 1.10 EUT Arrangement (Photographs) 15 2 Test Data 2.1 AC Power Line Conducted Emission 0.45 MHz โ 30 MHz N/A 2.2 Radiated Emission (Electric Field)30 MHz โ 1000 MHz 16 โ 17 COPY JQA Application No. :400-90545 FCC ID : MOZD01RB Model No. :D01SB Issue Date :December 8, 1999 Standard :CFR 47 FCC Rules Part 15 Page 3 of 17 JQA QUALITY ASSURANCE ORGANIZATION 1 DOCUMENTATION 1.1 TEST REGULATION FCC Rules and Regulations Part 15 Subpart A and B (June 23, 1989) Superregenerative Receiver Test procedure : AC power line conducted emission and radiated emission tests were performed according to the procedures in ANSI C63.4-1992. 1.2 GENERAL INFORMATION 1.2.1 Test facility : 1) Test Facility located at EMC Engineering Dept. Testing Div. : No.2 and 3 Anechoic Chambers( 3 meters Site ) FCC filing No. : 31040/SIT 1300F2 2) EMC Engineering Dept. Testing Div. is recognized under the National Voluntary Laboratory accreditation Program for satisfactory compliance established in title 15, Part 285 Code of Federal Regulations. NVLAP Lab Code : 200189-0 (Effective through : June 30, 2000) 1.2.2 Description of the Equipment Under Test (EUT) : 1) Type of Equipment : Remote Keyless Entry System(Receiver) 2) Product Type : Production 3) Category : Low Power Communication Device Receiver 4) EUT Authorization : Certification 5) FCC ID : MOZD01RB 6) Trade Name : TOKAI RIKA 7) Model No. : D01SB 8) Tuning Frequency Range : 315 MHz 9) Highest Frequency Used in the EUT : 304.3 10) Serial No. : - 11) Date of Manufacture : - 12) Power Rating : DC 12V 13) EUT Grounding : None 1.2.3 Definitions for symbols used in this test report : x - indicates that the listed condition, standard or equipment is applicable for this report. - indicates that the listed condition, standard or equipment is not applicable for this report. COPY JQA Application No. :400-90545 FCC ID : MOZD01RB Model No. :D01SB Issue Date :December 8, 1999 Standard :CFR 47 FCC Rules Part 15 Page 4 of 17 JQA QUALITY ASSURANCE ORGANIZATION 1.3 TEST CONDITION 1.3.1 The measurement of the AC Power Line Conducted Emission - was performed in the following test site. x - was not applicable. Test location : Safety Testing Center EMC Engineering Dept. Testing Div. 21-25, Kinuta 1-chome, Setagaya-ku, Tokyo 157-8573, Japan - Shielded Enclosure - Anechoic Chamber No. 2 (portable Type) Used test instruments : Type Model No. Manufacturer Serial No. Last Cal. Interval - Field Strength Meter ESH-2 Rohde & Schwarz 880370/016 May 1999 1 Year - Field Strength Meter ESH-3 Rohde & Schwarz 881460/016 May 1999 1 Year - Field Strength Meter ESH-3 Rohde & Schwarz 881460/030 Nov 1999 1 Year - LISN KNW-407 Kyoritsu Electrical 8-833-6 Apr. 1999 1 Year - LISN KNW-407 Kyoritsu Electrical 8-855-2 Apr. 1999 1 Year - LISN KNW-407 Kyoritsu Electrical 8-757-1 Apr. 1999 1 Year - RF Cable 3D-2W Fujikura 155-21-005 Apr. 1999 1 Year - RF Cable 3D-2W Fujikura 155-21-006 Apr. 1999 1 Year COPY JQA Application No. :400-90545 FCC ID : MOZD01RB Model No. :D01SB Issue Date :December 8, 1999 Standard :CFR 47 FCC Rules Part 15 Page 5 of 17 JQA QUALITY ASSURANCE ORGANIZATION 1.3.2 The measurement of the Radiated Emission(30 MHz โ 1000 MHz) x - was performed in the following test site. - was not applicable. Test location : Safety Testing Center EMC Engineering Dept. Testing Div. 21-25, Kinuta 1-chome, Setagaya-ku, Tokyo 157-8573, Japan x - Anechoic Chamber No. 2 (3 meters) - Anechoic Chamber No. 3 (3 meters) Validation of Site Attenuation : 1) Last Confirmed Date :March, 1999 2) Interval :1 year Used test instruments : Type Model No. Manufacturer Serial No. Last Cal. Interval - Field Strength Meter ESV Rohde & Schwarz 872148/039 May 1999 1 Year - Field Strength Meter ESVP Rohde & Schwarz 879783/030 May 1999 1 Year x - Field Strength Meter ESVP Rohde & Schwarz 881478/004 May 1999 1 Year - Field Strength Meter ESVP Rohde & Schwarz 881478/005 May 1999 1 Year - Antenna KBA-511A Kyoritsu Electrical 0-201-13 Nov. 1999 1 Year x - Antenna KBA-511A Kyoritsu Electrical 0-170-1 Nov. 1999 1 Year - Antenna KBA-611 Kyoritsu Electrical 0-210-5 Nov. 1999 1 Year x - Antenna KBA-611 Kyoritsu Electrical 0-147-14 Nov. 1999 1 Year x - RF Cable 5D-2W Fujikura 155-21-001 Feb. 1999 1 Year - RF Cable 5D-2W Fujikura 155-21-002 Feb. 1999 1 Year COPY JQA Application No. :400-90545 FCC ID : MOZD01RB Model No. :D01SB Issue Date :December 8, 1999 Standard :CFR 47 FCC Rules Part 15 Page 6 of 17 JQA QUALITY ASSURANCE ORGANIZATION 1.3.3 The measurement oโฆ
Text truncated - open the document above for the full version.
21-25, Kinuta 1-chome, Setagaya-ku ยท Tokyo ยท Japan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | 315 MHz - 315 MHz | - |
RKE Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Receiver
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
RKE Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Smart Key Box
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
RECEIVER
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter