
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
From: Mike Kuo Sent: Friday, January 11, 2002 12:11 PM To: '[email protected]' Cc: Scott Wang Subject: FW: Tokai Rika Co., Ltd., FCC ID:MOZRI-20BTY, Assessment No:AN02T1741 Dear Kyozo: Thank you very much in selecting Compliance Certification Services as your TCB for Grant of Equipment Authorization. I have done the reviews for above TCB application with the following questions. Best Regards ========================= Mike Kuo Compliance Certification Services 561F Monterey Road Morgan Hill CA 95037 Telephone number:408-463-0885 EXT:105 Fax number :408-463-0888 E-Mail:[email protected] -----Original Message----- From: CERTADM Sent: Friday, January 11, 2002 12:07 PM To: '[email protected]' Subject: Tokai Rika Co., Ltd., FCC ID:MOZRI-20BTY, Assessment No:AN02T1741 Notice_content ------------- Question #1: Request for Confidentiality: Seven documents are listed in the letter. There are no document titled Product Description and construction Drawing. In addition, it is FCC policy not to grant the request for confidentiality on the following documents: Test Reports Picture ( External and Internal Photos ) User Manual ( if this is to be considered as Product Description ). Please revise your letter by deleting product description, construction drawing, test reports and pictures. Question #2: Page 22 of 25 of test report : EUT was measured at distance of 10 meter with average detector and calcuated the distance correction factor to compare with field strength limits @ 300 meter. In accordance with 15.209 (e) and 15.35 (b) of FCC rules, when the limits are based on measurements employing average detector, peak limits also applied. Please provide peak readings for frequency range between 110- 490 kHz. Best Regards Mike Kuo / TCB Certifier The items indicated above must be submitted before processing can continue on the above referenced application. Failure to provide the requested information within 60 days of the original e-mail date may result in application dismissal and forfeiture of the filing fee. Also, please note that partial responses increase processing time and should not be submitted. Any questions about the content of this correspondence should be directed to the e-mail address listed below the name of the sender.
Immobilizer MDL RI-20BTY
Amplifier MDL RI-20BTY Amplifier MDL RI-20BTY
JAPAN QUALITY ASSURANCE ORGANIZATION 2096, OHHATA, TSURU-SHI, YAMANASHI 402-0045, JAPAN PHONE (0554) 43-5517, FAX (0554) 43-6316 JQA APPLICATION NO.: 441-10859 Issue Date :January 7, 2002 Page 1 of 25 EMI TEST REPORT JQA APPLICATION NO. : 441-10859 Model No. : RI-20BTY Type of Equipment : Immobilizer System Regulations Applied : CFR 47 FCC Rules and Regulations Part 15 FCC ID : MOZRI-20BTY Applicant : TOKAI RIKA CO., LTD. Address : 260, Toyota 3-chome, Oguchi-cho, Niwa-gun, Aichi-ken 480-0195, Japan Manufacture : TOKAI RIKA CO., LTD. Address : 260, Toyota 3-chome, Oguchi-cho, Niwa-gun, Aichi-ken 480-0195, Japan Received date of EUT : December 11, 2001 Final Judgment : Passed TEST RESULTS IN THIS REPORT are obtained in use of equipment that is traceable to National Institute of Advanced Industrial Science and Technology (AIST) of Japan and Communication Research Laboratory (CRL) of Japan. The test results only responds to the tested sample. THIS REPORT should not be reproduced, except in full, without the approval of the JQA SAFETY & EMC CENTER EMC ENGINEERING DEPT. TSURU EMC BRANCH. JQA Application No. :441-10859 FCC ID :MOZRI-20BTY Model No. :RI-20BTY Issue Date :January 7, 2002 Standard :CFR 47 FCC Rules Part 15 Page 2 of 25 JAPAN QUALITY ASSURANCE ORGANIZATION TABLE OF CONTENTS Page 1 Documentation 1.1 Test Regulation 3 1.2 General Information 3 1.3 Test Condition 4 – 8 1.4 EUT Modifications / Deviation from Standard 9 1.5 Test results 10 1.6 Summary 11 1.7 Test Configuration / Operation of EUT 12 1.8 EUT Arrangement(Drawing) 13 1.9 Preliminary Test and Test-setup (Drawings) 14 – 19 1.10 EUT Arrangement (Photographs) 20 2 Test Data 2.1 AC Power Line Conducted Emission 0.45 MHz – 30 MHz N / A 2.2 Radiated Emission (Electric Field)9 kHz – 30 MHz 21 – 22 2.3 Radiated Emission (Electric Field)30 MHz – 1000 MHz 23 – 24 2.4 Radiated Emission (Electric Field) Above 1 GHz N / A 2.5 Frequency Stability N / A 2.6 Occupied Bandwidth N / A JQA Application No. :441-10859 FCC ID :MOZRI-20BTY Model No. :RI-20BTY Issue Date :January 7, 2002 Standard :CFR 47 FCC Rules Part 15 Page 3 of 25 JAPAN QUALITY ASSURANCE ORGANIZATION 1 DOCUMENTATION 1.1 TEST REGULATION FCC Rules and Regulations Part 15 Subpart A and C (June 23, 1989) Intentional Radiators Test procedure : AC power line conducted emission, radiated emission, frequency stability and occupied bandwidth tests were performed according to the procedures in ANSI C63.4-1992. 1.2 GENERAL INFORMATION 1.2.1 Test facility : 1) Test Facility located at JQA SAFETY & EMC CENTER EMC ENGINEERING DEPT. TSURU EMC BRANCH: Open Site No.1, No.2, An Anechoic Chamber (3 m and 10 m, on common plane)and a Shielded Room Date of Listing : March 30,1999 2) JQA SAFETY & EMC CENTER EMC ENGINEERING DEPT. TSURU EMC BRANCH is recognized under the National Voluntary Laboratory Accreditation Program for satisfactory compliance established in title 15, Part 285 Code of Federal Regulations. NVLAP Lab Code : 200192-0 (Effective through : June 30, 2002) 1.2.2 Description of the Equipment Under Test (EUT) : 1) Type of Equipment : Immobilizer System 2) Product Type : Production 3) Category : Low Power Communication Device Transmitter 4) EUT Authorization : Certification 5) FCC ID : MOZRI-20BTY 6) Trade Name : - 7) Model No. : RI-20BTY 8) Operating Frequency Range : 134.2 kHz 9) Highest Frequency Used in the EUT : 134.2 kHz 10) Serial No. : - 11) Date of Manufacture : - 12) Power Rating : 12.0 VDC 13) EUT Grounding : None 1.2.3 Definitions for symbols used in this test report : x - indicates that the listed condition, standard or equipment is applicable for this report. - indicates that the listed condition, standard or equipment is not applicable for this report. JQA Application No. :441-10859 FCC ID :MOZRI-20BTY Model No. :RI-20BTY Issue Date :January 7, 2002 Standard :CFR 47 FCC Rules Part 15 Page 4 of 25 JAPAN QUALITY ASSURANCE ORGANIZATION 1.3 TEST CONDITION 1.3.1 The measurement of the AC Power Line Conducted Emission - was performed in the following test site. x - was not applicable. Test location : Safety Testing Center EMC Engineering Dept. Tsuru EMC Branch 2096 Ohhata, Tanbozawa, Tsuru-shi Yamanashi-ken 402-0045, JAPAN - Shielded Room No.1 - Shielded Room No.2 - Anechoic Chamber - Open Site No.1 - Open Site No.2 Used test instruments : Type Model No. Manufacturer Serial No. Last Cal. Interval - Test Receiver ESI7 Rohde & Schwarz 100059 Oct. 2001 1 Year - Test Receiver ESH-3 Rohde & Schwarz 881460/016 May. 2001 1 Year - LISN(for Peripheral) KNW-407 Kyoritsu Electrical 8-833-5 May. 2001 1 Year - LISN(for EUT) KNW-407 Kyoritsu Electrical 8-680-14 May. 2001 1 Year - LISN KNW-243C Kyoritsu Electrical 8-831-1 May. 2001 1 Year - LISN KNW-243C Kyoritsu Electrical 8-831-2 May. 2001 1 Year - LISN KNW-243C Kyoritsu Electrical 8-831-3 May. 2001 1 Year - LISN KNW-243C Kyoritsu Electrical 8-831-4 May. 2001 1 Year - LISN ESH 2-Z5 Rohde & Schwarz 879341/007 May. 2001 1 Year - RF Cable 3D-2W Fujikura No.1 May. 2001 1 Year - RF Cable 3D-2W Fujikura No.2 May. 2001 1 Year - RF Cable 3D-2W Fujikura No.3 May. 2001 1 Year - 50ohm Termination - TDC 15406501E1 Feb. 2001 1 Year - 50ohm Termination - - 15406502E1 Feb. 2001 1 Year JQA Application No. :441-10859 FCC ID :MOZRI-20BTY Model No. :RI-20BTY Issue Date :January 7, 2002 Standard :CFR 47 FCC Rules Part 15 Page 5 of 25 JAPAN QUALITY ASSURANCE ORGANIZATION 1.3.2 The measurement of the Radiated Emission(9 kHz – 30 MHz) x - was performed in the following test site. - was not applicable. Test location : Safety Testing Center EMC Engineering Dept. Tsuru EMC Branch 2096 Ohhata, Tsuru-shi, Yamanashi-ken 402-0045, JAPAN x - Open Site No. 1 (3, 10 or 30 meters) - Open Site No. 2 (3, 10 or 30 meters) - Anechoic Chamber(3 or 10 meters) Validation of Site Attenuation : 1) Last Confirmed Date : N/A 2) Interval : N/A Used test instruments : Type Model No. Manufacturer Serial No. Last Cal. Interval x - Test Receiver ESI7 Rohde & Schwarz 100059 Oct. 2001 1 Year -…
Text truncated - open the document above for the full version.
JQA Application No. :441-10859 FCC ID :MOZRI-20BTY Model No. :RI-20BTY Issue Date :January 7, 2002 Standard :CFR 47 FCC Rules Part 15 Page 22 of 25 JAPAN QUALITY ASSURANCE ORGANIZATION The distance of measurements was reduced to 10 meters. Date : December 17, 2001 Temp.: 22 °C Humi.: 22 % Operating Frequency : 134.2 kHz Distance of Measurement : 10 meters Frequency Meter Reading Field Strength (MHz) (dBμV/m) (dBμV/m) Fundamental 0.134 39.3 39.3(Average) 0.134 46.2 46.2(Peak) Harmonic Frequency 0.268 < 33.2 < 33.2(Average) 0.268 < 39.4 < 39.4(Peak) 0.402 < 31.4 < 31.4(Average) 0.402 < 36.6 < 36.6(Peak) 0.536 < 30.1 < 30.1 0.670 < 29.0 < 29.0 0.804 < 28.1 < 28.1 0.938 < 27.3 < 27.3 1.072 < 27.0 < 27.0 1.206 < 27.0 < 27.0 1.340 < 27.0 < 27.0 Note: 1. Meter reading value shows field strength, because the value includes antenna factor. 2. The symbol of “<” means “or less”. 3. Measuring Instrument Setting: Frequency Range : 110 kHz to 490 kHz Detector Function : Average/Peak, IF Band width : 10 kHz Frequency Range : 536.8 kHz to 1345 kHz Detector Function : CISPR Quasi-peak Peak, IF Band width : 9 kHz For fundamental, the measured field strength was extrapolated to distance 300 meters, using the formula that field strength varies as the inverse distance square(40 dB per decade of distance). Calculation : Average: 39.3 dBμV/m – 20log 10 ((300/10) 2 )= 39.3 – 59.1 = -19.8 dBμV/m at 300 meters Limits for fundamental(§15.209(a)) = 20log 10 (2400/134.0) = 25.1 dBμV/m Peak: 46.2 dBμV/m – 20log 10 ((300/10) 2 )= 46.2 – 59.1 = -12.9 dBμV/m at 300 meters Limits for fundamental(§15.209(a)) = 20log 10 (2400/134.0)+20 = 45.1 dBμV/m Tested by : Yuichi Fukumoto Testing Engineer
JQA Application No. :441-10859 FCC ID :MOZRI-20BTY Model No. :RI-20BTY Issue Date :January 7, 2002 Standard :CFR 47 FCC Rules Part 15 Page 20 of 25 JAPAN QUALITY ASSURANCE ORGANIZATION 1.10 TEST ARRANGEMENT (PHOTOGRAPHS) PHOTOGRAPHS OF EUT CONFIGURATION FOR RADIATED EMISSIONS MEASUREMENT Photograph present configuration with maximum emission - Front View – - Rear View –
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.1342 MHz - 0.1342 MHz | - |
RKE Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Receiver
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
RKE Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Smart Key Box
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
RECEIVER
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter