Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Immobilizer MDL RI-21BTY
Amplifier MDL RI-21BTY Amplifier MDL RI-21BTY
JAPAN QUALITY ASSURANCE ORGANIZATION 2096, OHHATA, TSURU-SHI, YAMANASHI 402-0045, JAPAN PHONE (0554) 43-5517, FAX (0554) 43-6316 JQA APPLICATION NO.: 441-20249 Issue Date :July 8, 2002 Page 1 of 25 EMI TEST REPORT JQA APPLICATION NO. : 441-20249 Model No. : RI-21BTY Type of Equipment : Immobilizer System Regulations Applied : CFR 47 FCC Rules and Regulations Part 15 FCC ID : MOZRI-21BTY Applicant : TOKAI RIKA CO., LTD. Address : 260, Toyota 3-chome, Oguchi-cho, Niwa-gun, Aichi-ken 480-0195, Japan Manufacture : TOKAI RIKA CO., LTD. Address : 260, Toyota 3-chome, Oguchi-cho, Niwa-gun, Aichi-ken 480-0195, Japan Received date of EUT : June 28, 2002 Final Judgment : Passed TEST RESULTS IN THIS REPORT are obtained in use of equipment that is traceable to National Institute of Advanced Industrial Science and Technology (AIST) of Japan and Communication Research Laboratory (CRL) of Japan. The test results only responds to the tested sample. THIS REPORT should not be reproduced, except in full, without the approval of the JQA SAFETY & EMC CENTER EMC ENGINEERING DEPT. TSURU EMC BRANCH. JQA Application No. :441-20249 FCC ID :MOZRI-21BTY Model No. :RI-21BTY Issue Date :July 8, 2002 Standard :CFR 47 FCC Rules Part 15 Page 2 of 25 JAPAN QUALITY ASSURANCE ORGANIZATION TABLE OF CONTENTS Page 1 Documentation 1.1 Test Regulation 3 1.2 General Information 3 1.3 Test Condition 4 – 8 1.4 EUT Modifications / Deviation from Standard 9 1.5 Test results 10 1.6 Summary 11 1.7 Test Configuration / Operation of EUT 12 1.8 EUT Arrangement(Drawing) 13 1.9 Preliminary Test and Test-setup (Drawings) 14 – 19 1.10 EUT Arrangement (Photographs) 20 2 Test Data 2.1 AC Power Line Conducted Emission 0.45 MHz – 30 MHz N / A 2.2 Radiated Emission (Electric Field)9 kHz – 30 MHz 21 – 22 2.3 Radiated Emission (Electric Field)30 MHz – 1000 MHz 23 – 24 2.4 Radiated Emission (Electric Field) Above 1 GHz N / A 2.5 Frequency Stability N / A 2.6 Occupied Bandwidth N / A JQA Application No. :441-20249 FCC ID :MOZRI-21BTY Model No. :RI-21BTY Issue Date :July 8, 2002 Standard :CFR 47 FCC Rules Part 15 Page 3 of 25 JAPAN QUALITY ASSURANCE ORGANIZATION 1 DOCUMENTATION 1.1 TEST REGULATION FCC Rules and Regulations Part 15 Subpart A and C (June 23, 1989) Intentional Radiators Test procedure : AC power line conducted emission, radiated emission, frequency stability and occupied bandwidth tests were performed according to the procedures in ANSI C63.4-1992. 1.2 GENERAL INFORMATION 1.2.1 Test facility : 1) Test Facility located at JQA SAFETY & EMC CENTER EMC ENGINEERING DEPT. TSURU EMC BRANCH: Open Site No.1, No.2, An Anechoic Chamber (3 m and 10 m, on common plane)and a Shielded Room FCC Registration Number:90728 (Date of Listing : April 2,2002 2) JQA SAFETY & EMC CENTER EMC ENGINEERING DEPT. TSURU EMC BRANCH is recognized under the National Voluntary Laboratory Accreditation Program for satisfactory compliance established in title 15, Part 285 Code of Federal Regulations. NVLAP Lab Code : 200192-0 (Effective through : June 30, 2003) 1.2.2 Description of the Equipment Under Test (EUT) : 1) Type of Equipment : Immobilizer System 2) Product Type : Production 3) Category : Low Power Communication Device Transmitter 4) EUT Authorization : Certification 5) FCC ID : MOZRI-21BTY 6) Trade Name : - 7) Model No. : RI-21BTY 8) Operating Frequency Range : 134.2 kHz 9) Highest Frequency Used in the EUT : 134.2 kHz 10) Serial No. : - 11) Date of Manufacture : - 12) Power Rating : 12.0 VDC 13) EUT Grounding : None 1.2.3 Definitions for symbols used in this test report : x - indicates that the listed condition, standard or equipment is applicable for this report. - indicates that the listed condition, standard or equipment is not applicable for this report. JQA Application No. :441-20249 FCC ID :MOZRI-21BTY Model No. :RI-21BTY Issue Date :July 8, 2002 Standard :CFR 47 FCC Rules Part 15 Page 4 of 25 JAPAN QUALITY ASSURANCE ORGANIZATION 1.3 TEST CONDITION 1.3.1 The measurement of the AC Power Line Conducted Emission - was performed in the following test site. x - was not applicable. Test location : Safety Testing Center EMC Engineering Dept. Tsuru EMC Branch 2096 Ohhata, Tanbozawa, Tsuru-shi Yamanashi-ken 402-0045, JAPAN - Shielded Room No.1 - Shielded Room No.2 - Anechoic Chamber - Open Site No.1 - Open Site No.2 Used test instruments : Type Model No. Manufacturer Serial No. Last Cal. Interval - Test Receiver ESI7 Rohde & Schwarz 100059 Oct. 2001 1 Year - Test Receiver ESH-3 Rohde & Schwarz 881460/016 May. 2002 1 Year - LISN(for Peripheral) KNW-407 Kyoritsu Electrical 8-833-5 Aug. 2001 1 Year - LISN(for EUT) KNW-407 Kyoritsu Electrical 8-680-14 Aug. 2001 1 Year - LISN KNW-407 Kyoritsu Electrical 7-757-1 Jun. 2002 1 Year - LISN KNW-243C Kyoritsu Electrical 8-692-5 Aug. 2001 1 Year - LISN KNW-243C Kyoritsu Electrical 8-831-2 Jun. 2002 1 Year - LISN KNW-243C Kyoritsu Electrical 8-831-3 Jun. 2002 1 Year - LISN KNW-243C Kyoritsu Electrical 8-831-4 Jun. 2002 1 Year - RF Cable 3D-2W Fujikura No.1 May. 2001 1 Year - RF Cable 3D-2W Fujikura No.2 May. 2001 1 Year - RF Cable 3D-2W Fujikura No.3 May. 2001 1 Year - 50ohm Termination - TDC 15406501E1 Feb. 2001 1 Year - 50ohm Termination - - 15406502E1 Feb. 2001 1 Year JQA Application No. :441-20249 FCC ID :MOZRI-21BTY Model No. :RI-21BTY Issue Date :July 8, 2002 Standard :CFR 47 FCC Rules Part 15 Page 5 of 25 JAPAN QUALITY ASSURANCE ORGANIZATION 1.3.2 The measurement of the Radiated Emission(9 kHz – 30 MHz) x - was performed in the following test site. - was not applicable. Test location : Safety Testing Center EMC Engineering Dept. Tsuru EMC Branch 2096 Ohhata, Tsuru-shi, Yamanashi-ken 402-0045, JAPAN x - Open Site No. 1 (3, 10 or 30 meters) - Open Site No. 2 (3 or 10 meters) - Anechoic Chamber(3 or 10 meters) Validation of Site Attenuation : 1) Last Confirmed Date : N/A 2) Interval : N/A Used test instruments : Type Model No. Manufacturer Serial No. Last Cal. Interval x - Test Receiver ESI7 Rohde & Schwarz 100059 Oct. 2001 1…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.1342 MHz - 0.1342 MHz | - |
RKE Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Receiver
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
RKE Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Smart Key Box
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
RECEIVER
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter