
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Parts 3 Connection to Computer 4 The range of control Angle 5 Installing Monitor Driver 6 Name and Function of Front 8 Power Management Feature 10 Adjusting OSD 11 Standard Signal Table 17 Specification 18 Troubleshooting 19 Warning 21 Table of Contents INFORMATION TO USER : This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to Part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmfulinterference in a residential installation.This equipment generates, uses and canradiate radio frequency energy and,if not installed and used in accordance withthe instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particularinstallation; if this equipment does cause harmful interference to radio ortelevision reception, which can be determined by determined by turning theequipment off and on, the user is encouraged to try to correct the interference byone or more of the fllowing measures: 1. Reorient/Relocate the receiving antenna.2. Increase the separation between the equipment and receiver.3. Connect the equipment into an outlet on a circuit difference from that to which the receiver is connected. 4. Consult the dealer or an experienced radio/TV technician for help. Shielded interface cable has to be used to ensure product compliance. CAUTION : Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user's authority to operate the equipment 3 2 Parts LCD Monitor Place the monitor to face the user and then adjust the monitor angle.Take a break (for about 10 minutes) at every hour during the work with monitor. Refer to the following figure to take the correct posture. about 50cm Look down the monitor below the horizon. Relax shoulders and arms, and sit back on the chair. Adjust the monitor to prevent reflection. Adjust the monitor stand to acquire required angle. Keep feet flat on the ground. Maintain the arms horizontally and place hands softly on the keyboard. Good Posture Guide 12V-DC Adapter (Option) User's Manual / Warranty Card Signal Cable AC Power Cable Installation Diskette For use only with power supplyM ANUFACTURER : AcBel MODEL : API-208-98010M ANUFACTURER : MODEL : PSCV45114AM ANUFACTURER : MODEL : U048-S012035HAM ANUFACTURER : MODEL : LS-42S Option Basic 5 4 Connection to Signal Source 1. Use 220 V or 110 V. (Free Voltage)2. Connect monitor and Signal Source via Signal cable3. Power on the monitor and computer.4. Connection is finished. Basic General For Macintosh Adapter for Macintosh (Optional)Refer to the table on the rear side ofthe optional Macintosh adapter andadjust DIP switch by the resolution. T he range of control Angle Power Adapter Form Power Stand Form Option Forward 4 Default Backward 31 Forward 4 Default Backward 31 Port For 12V DC Cable From adapter or Stand. Port For Signal Cable From Signal Source. Port For AC Power Cable < Power source connection > < SIgnal cable connection> 7 6 Click 'Finish'. Click 'Next>'. Click 'Advanced..'. Click 'Next>'. Click 'Monitor'. Click 'Change..'. Click 'Display a list of all...'.Click 'Next>'. Click 'Have Disk..'. Select the driver and click 'OK'. Click 'Next>'. 3. Select "Exit" if the monitor model is changed, and then reboot the Windows. Installing Monitor Driver 1. Insert the Diskette to the Floppy Diskette driver. 2. Double-click "Install.exe". 3. Select the model and click "OK" button.4. Select inf file, and then click "OK" button.5. Click "Exit" button to close the installation. Automatic Installation Manual Installation 1. Insert the Diskette to the Floppy Diskette driver.2. Click 'My Computer' and follow the procedure below. Click 'Control Panel'. Click 'Display'. Click 'Settings'. Run (Click) "Install" at Floppy driver and select the model name to set theoptimum display in Window 95, 98 or 2000. Use the Driver provided. 9 8 , +/ -/ Power button Power button is located in the lower center of the Front Bezel.You can push the button to turn on/off the power. Power Indicating LED If the green LED around the power switch turns into blinking, it indicates the monitor is in power saving mode. On Screen Display (OSD) Function Button OSD buttons on the front of bezel perform the following functions. MENU : Press the button to display menus. If you press this button when OSD is displayed, you can switch display to the previous menu and exit menu. SELECT/ AUTO : Press this button, when OSD is displayed, to select the menu.. When OSD is not displayed, you can perform automatic setting.. POWER : Power button. : By pressing these button when OSD is displayed, you can move cursor into the menus which you want. After the SELECT button, you can change gauge level or select sub menus. When OSD is not displayed, you can adjust brightness and contrast. Functions Name and Function of Front Front panel SELECT/ AUTO BUTTON MENU BUTTON POWER BUTTON +/ BUTTON - / BUTTON 11 10 Horizontal Position Adjusting OSD Brightness Contrast MENU 1. Press the Menu button.2. Use to move Brightness ICON. 3. Use SELECT button to select it.4. Use to adjust the brightness. 5. Press SELECT button to exit.6. Press MENU button to finish adjusting OSD. SELECT MENU SELECT MENU SELECT 1. Press the Menu button.2. Use to move Contrast ICON. 3. Use SELECT button to select it.4. Use to adjust the contrast. 5. Press SELECT button to exit.6. Press MENU button to finish adjusting OSD. 1. Press the Menu button.2. Use to move H-Position ICON. 3. Use SELECT button to select it.4. Use to adjust display left or right. 5. Press SELECT button to exit.6. Press MENU button to finish adjusting OSD. No image is displayed with Green blinking. Monitor is in power saving mode.Use mouse or keyboard to release power saving mode. No image is displayed without LED on. Power cable plug must be pulled out.Check the power plug on monitor and on the wall. "Out of range" displayeβ¦
Text truncated - open the document above for the full version.
7 8 MHz
March 21, 2002 Hansol Electronics Inc. 27-29, Hanchun-ri, Ducksan-myun, Jinchon-kun, Chungbuk, 365-840, Korea Tel: 82-43-530-8500 Fax: 82-43-536-8105 Hansol Electronics Inc. FCC ID : MSAB15BF-A Dear Mr. Mike, We, Hansol Electronics Inc. have made the following change to the subject device as below; 1) R101 and R 103 were removed in main board. 2) R102 changed to 100 ohm from 22 ohm in main board. 3) C101 changed to 5 pF from 10 pF in main board. Sincerely, S. P. Yang / Hansol Electronics Inc.
CERTiTEK Standards Laboratory Co., Ltd. 386-1, Ho-Dong, Yongin-City, Kyungki-Do, Korea 449-100 Tel: +82-31-339-9970 Fax: +82-31-339-9855 http://www.certitek.com/ Test Report No.: CTK02-F048 Date: May 8. 2002 Page 1 of 1 This Report shall not be reproduced except in full without the written approval of CERTiTEK Form No.: CTK-FF1.1 CERTiTEK EUT External Photographs
CERTiTEK Standards Laboratory Co., Ltd. 386-1, Ho-Dong, Yongin-City, Kyungki-Do, Korea 449-100 Tel: +82-31-339-9970 Fax: +82-31-339-9855 http://www.certitek.com/ Test Report No.: CTK02-F048 Date: May 8. 2002 Page 1 of 1 This Report shall not be reproduced except in full without the written approval of CERTiTEK Form No.: CTK-FF1.1 CERTiTEK Photographs related to Label
CERTiTEK Standards Laboratory Co., Ltd. 386-1, Ho-Dong, Yongin-City, Kyungki-Do, Korea 449-100 Tel: +82-31-339-9970 Fax: +82-31-339-9855 http://www.certitek.com/ Test Report No.: CTK02-F048 Date: May 8. 2002 Page 1 of 1 This Report shall not be reproduced except in full without the written approval of CERTiTEK Form No.: CTK-FF1.1 CERTiTEK EUT Internal Photographs CERTiTEK Standards Laboratory Co., Ltd. 386-1, Ho-Dong, Yongin-City, Kyungki-Do, Korea 449-100 Tel: +82-31-339-9970 Fax: +82-31-339-9855 http://www.certitek.com/ Test Report No.: CTK02-F048 Date: May 8. 2002 Page 2 of 2 This Report shall not be reproduced except in full without the written approval of CERTiTEK Form No.: CTK-FF1.1 CERTiTEK PCB CERTiTEK Standards Laboratory Co., Ltd. 386-1, Ho-Dong, Yongin-City, Kyungki-Do, Korea 449-100 Tel: +82-31-339-9970 Fax: +82-31-339-9855 http://www.certitek.com/ Test Report No.: CTK02-F048 Date: May 8. 2002 Page 3 of 3 This Report shall not be reproduced except in full without the written approval of CERTiTEK Form No.: CTK-FF1.1 CERTiTEK CERTiTEK Standards Laboratory Co., Ltd. 386-1, Ho-Dong, Yongin-City, Kyungki-Do, Korea 449-100 Tel: +82-31-339-9970 Fax: +82-31-339-9855 http://www.certitek.com/ Test Report No.: CTK02-F048 Date: May 8. 2002 Page 4 of 4 This Report shall not be reproduced except in full without the written approval of CERTiTEK Form No.: CTK-FF1.1 CERTiTEK - With Green C & C (GH027B) CERTiTEK Standards Laboratory Co., Ltd. 386-1, Ho-Dong, Yongin-City, Kyungki-Do, Korea 449-100 Tel: +82-31-339-9970 Fax: +82-31-339-9855 http://www.certitek.com/ Test Report No.: CTK02-F048 Date: May 8. 2002 Page 5 of 5 This Report shall not be reproduced except in full without the written approval of CERTiTEK Form No.: CTK-FF1.1 CERTiTEK - With DONG IL TECHNOLOGY Ltd (MGP161) CERTiTEK Standards Laboratory Co., Ltd. 386-1, Ho-Dong, Yongin-City, Kyungki-Do, Korea 449-100 Tel: +82-31-339-9970 Fax: +82-31-339-9855 http://www.certitek.com/ Test Report No.: CTK02-F048 Date: May 8. 2002 Page 6 of 6 This Report shall not be reproduced except in full without the written approval of CERTiTEK Form No.: CTK-FF1.1 CERTiTEK - With Feelux (FLI-15401)
CERTiTEK Standards Laboratory Co., Ltd. 386-1, Ho-Dong, Yongin-City, Kyungki-Do, Korea 449-100 Tel: +82-31-339-9970 Fax: +82-31-339-9855 http://www.certitek.com/ Test Report No.: CTK02-F048 Date: May 8. 2002 Page 1 of 1 This Report shall not be reproduced except in full without the written approval of CERTiTEK Form No.: CTK-FF1.1 CERTiTEK EMC TEST REPORT For FCC Test Report No. : CTK02-F048 Date of Issue : May 8. 2002 Model/Type No: : B15BF Kind of Product : LCD MONITOR Applicant : Hansol Electronics Inc. Applicant Address : 27-29, Hanchon-Ri, Ducksan-Myun, Jinchon-Gun, Chungbuk, 365-840, Korea Manufacturer : Hansol Electronics Inc. Manufacturer Address : 27-29, Hanchon-Ri, Ducksan-Myun, Jinchon-Gun, Chungbuk, 365-840, Korea Contact Person : Sun-Pil Yang Telephone : +82-43-530-8503 Received Date : April 8. 2002 Test period : Start: April 29. 2002 End: April 29. 2002 Test Results : In Compliance Not in Compliance The test results presented in this report relate only to the object tested. CERTiTEK Standards Laboratory Co., Ltd. is accredited by Korea Laboratory Accreditation Scheme (KOLAS) which signed the International Laboratory Accreditation Cooperation (ILAC) Mutual Recognition Arrangement (MRA) for the above test item(s) and test method(s). Tested by Reviewed by Michael Jang EMC Test Engineer James Hong EMC Technical Manager Date: May 8. 2002 Date: May 8. 2002 CERTiTEK Standards Laboratory Co., Ltd. 386-1, Ho-Dong, Yongin-City, Kyungki-Do, Korea 449-100 Tel: +82-31-339-9970 Fax: +82-31-339-9855 http://www.certitek.com/ Test Report No.: CTK02-F048 Date: May 8. 2002 Page 2 of 2 This Report shall not be reproduced except in full without the written approval of CERTiTEK Form No.: CTK-FF1.1 CERTiTEK REPORT REVISION HISTORY Date Revision Page No May 8. 2002 (CTK02-F048) Issued All This report shall not be reproduced except in full, without the written approval of CERTiTEK Standards Laboratory Co., Ltd. This document may be altered or revised by CERTiTEK Standards Laboratory Co., Ltd. personnel only, and shall be noted in the revision section of the document. Any alteration of this document not carried out by CERTiTEK Standards Laboratory Co., Ltd. will constitute fraud and shall nullify the document. CERTiTEK Standards Laboratory Co., Ltd. 386-1, Ho-Dong, Yongin-City, Kyungki-Do, Korea 449-100 Tel: +82-31-339-9970 Fax: +82-31-339-9855 http://www.certitek.com/ Test Report No.: CTK02-F048 Date: May 8. 2002 Page 3 of 3 This Report shall not be reproduced except in full without the written approval of CERTiTEK Form No.: CTK-FF1.1 CERTiTEK TABLE OF CONTENTS 1.0 General Product Description....................................................................................... 4 1.1 Model Differences..................................................................................................... 4 1.2 Device Modifications ................................................................................................. 4 1.3 EUT Configuration(s) ................................................................................................ 5 1.4 Test Software........................................................................................................... 5 1.5 EUT Operating Mode(s) ............................................................................................. 5 1.6 Calibration Details of Equipment Used for Measurement ................................................ 6 1.7 Test Facility ............................................................................................................. 6 1.8 Measurement Procedure............................................................................................ 6 1.9 Laboratory Accreditations and Listings ........................................................................ 7 2.0 Emissions Test Regulations ........................................................................................ 8 2.1 Conducted Voltage Emissions..................................................................................... 9 2.2 Radiated Electric Field Emissions .............................................................................. 10 Configurations ............................................................................................................. 11 APPENDIX A - TEST DATA ............................................................................................. 12 Conducted Voltage Emissions (Quasi-Peak reading) .................................................... 12 Radiated Electric Field Emissions (Quasi-Peak reading) ............................................... 18 CERTiTEK Standards Laboratory Co., Ltd. 386-1, Ho-Dong, Yongin-City, Kyungki-Do, Korea 449-100 Tel: +82-31-339-9970 Fax: +82-31-339-9855 http://www.certitek.com/ Test Report No.: CTK02-F048 Date: May 8. 2002 Page 4 of 4 This Report shall not be reproduced except in full without the written approval of CERTiTEK Form No.: CTK-FF1.1 CERTiTEK 1.0 General Product Description This equipment use three invertors as below; Mfr.: Green C & C, Model: GH027B Mfr.: DONG IL TECHNOLOGY Ltd., Model: MGP161 Mfr.: Feelux, Model: FLI-15401 1.0.1 Tested Equipment Unless otherwise indicated, all tests were conducted on Model B15BF. Tests performed on Model were considered to be representative of Model(s) . 1.0.2 Equipment Size, Mobility and Identification Dimensions: 358 by 128 by 346 mm in Mobility: Hand-Held Table-top Floor-standing Serial No.: Not Applicable 1.0.3 Electrical Ratings Input: 100-240 V ac, 50/60 Hz Output: Not applicable 1.0.4 Test Voltage & Frequency Unless indicated otherwise on the individual data sheet or test results, the test voltage and frequency was as indicated below. Voltage: 120V Frequency: 60Hz 1.0.5 Clock & Other Frequencies Utilized 78MHz 1.1 Model Differences Not applicable 1.2 Device Modifications The following modifications were necessary for compliance: 1) R101 and R 103 were removed in main board. 2) R102 changed to 100 ohm frβ¦
Text truncated - open the document above for the full version.
CERTiTEK Standards Laboratory Co., Ltd. 386-1, Ho-Dong, Yongin-City, Kyungki-Do, Korea 449-100 Tel: +82-31-339-9970 Fax: +82-31-339-9855 http://www.certitek.com/ Test Report No.: CTK02-F048 Date: May 8. 2002 Page 1 of 1 This Report shall not be reproduced except in full without the written approval of CERTiTEK Form No.: CTK-FF1.1 CERTiTEK APPENDIX B - Test Setup Photos and Configuration Conducted Voltage Emissions CERTiTEK Standards Laboratory Co., Ltd. 386-1, Ho-Dong, Yongin-City, Kyungki-Do, Korea 449-100 Tel: +82-31-339-9970 Fax: +82-31-339-9855 http://www.certitek.com/ Test Report No.: CTK02-F048 Date: May 8. 2002 Page 2 of 2 This Report shall not be reproduced except in full without the written approval of CERTiTEK Form No.: CTK-FF1.1 CERTiTEK Radiated Electric Field Emissions
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |

15" CCTV MONITOR
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
19" CCTV MONITOR
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
17" CCTV MONITOR
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
17" CRT MONITER
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
17" LCD MONITER
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral