N5GHF5Inductive Tag Reader

Brooks Automation Inc.
Inductive Tag Reader - FCC ID N5GHF5 - Brooks Automation Inc.
Click to zoom

Application Details

Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Date of Grant
Mar 09, 2006
Application Purpose
Original Equipment
Date of Application
Mar 09, 2006
Equipment Note
Inductive Tag Reader
Frequency Range
13.56000000 - 13.56000000
Company
Brooks Automation Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User Manual HF5x Transponder Reade r (Serial/SECSII) 2 HF5x Transponder Reader (SECS1-Protocol), Release 1.4 ID060003 Rev 01-2006 Printed in Germany Subject to modifications © 2006 BROOKS Automation (Germany) GmbH RFID Division Gartenstrasse 19 D-95490 Mistelgau Germany Tel: +49 9279 991 910 Fax: +49 9279 991 900 E-mail: [email protected] 3 HF5x Transponder Reader (SECS1-Protocol), Release 1.4 TABLE OF CONTENTS 1 INTRODUCTION 6 1.1 About this Device ..................................................................6 1.2 About this Manual .................................................................7 2 SAFETY INSTRUCTIONS 8 2.1 Symbols and Types Used in this Manual ................................9 2.2 General Safety Instructions ..................................................10 2.3 ESD Instructions..................................................................11 2.4 Proper Use...........................................................................11 2.5 Qualified Personnel .............................................................12 2.6 Declaration of Conformity ...................................................13 2.6.1 USA – Federal Communications Commission (FCC) .....13 2.6.2 Europe – CE Conformity ...............................................14 3 PRODUCT DESCRIPTION 17 3.1 Indicating and Operating Elements.......................................17 3.2 Inside View .........................................................................18 3.3 Description ..........................................................................19 3.4 Labeling Information ...........................................................20 3.5 Technical Data.....................................................................20 3.5.1 Transponder Reader ......................................................20 3.5.2 Power Supply and Current Input ....................................21 3.6 Contents of Delivery ............................................................21 3.7 Warranty and Liability .........................................................21 4 INSTALLATION 22 4.1 Installation Environment ......................................................22 4.2 Qualified Installation Personnel ...........................................23 4.3 Unpacking ...........................................................................23 4.3.1 Disposal of Packing Material .........................................23 4.4 Mounting the Transponder Reader .......................................23 4.4.1 Dimensions for Planning ...............................................24 4.5 Installing the Antenna ..........................................................25 4.5.1 Positioning ....................................................................25 4.5.2 Available Antenna Types...............................................25 4.5.3 Dimensions for Planning ...............................................26 4.6 Connecting the Transponder Reader .....................................27 4.6.1 Antenna ........................................................................27 4.7 Power Connection................................................................27 4.8 Terminal Connection ...........................................................28 4.9 External Input and Output (optional) ....................................28 4.10 Starting Up ..........................................................................29 4 HF5x Transponder Reader (SECS1-Protocol), Release 1.4 4.10.1 Required Operating Conditions......................................29 4.10.2 Parameter of Serial Interface .........................................29 5 OPERATION 30 5.1 Operating Personnel.............................................................30 5.2 Introduction .........................................................................30 5.3 SECS-1 Implementation.......................................................31 5.3.1 Character Structure........................................................31 5.3.2 Block Transfer Protocol.................................................31 5.4 SECS-2 Implementation.......................................................35 5.4.1 Introduction...................................................................35 5.4.2 Data Items .....................................................................36 5.4.3 Message set ...................................................................37 Data Item Dictionary ...............................................................39 5.5 SEMI E99 ............................................................................60 5.5.1 Introduction...................................................................60 5.5.2 State Models .................................................................60 5.5.3 Valid Services per State.................................................63 5.6 Message Details ...................................................................64 5.6.1 Equipment status ...........................................................64 5.6.2 Equipment Control ........................................................66 5.6.3 System Errors................................................................68 5.6.4 Subsystem Control and Data ..........................................69 5.7 SECS-1 MESSAGE EXAMPLES .........................................84 6 SERVICE AND ERROR HANDLING 115 6.1 General.............................................................................. 115 6.2 Qualified Error Handling Personnel ................................... 115 6.3 Safety Instructions ............................................................. 116 6.4 Errors Indicated by the LEDs ............................................. 116 6.4.1 Power LED Not Illuminated ........................................ 116 6.5 Reader Does Not Respond or Transmit or Cannot be Controlled by the Host ...................................................... 117 6.6 Reset .....…

Text truncated - open the document above for the full version.

Cover Letter(s)

27 January 2006

Cover Letter(s)

Request for Confidentiality in accordance with 47 CFR 0.459 Date: 31 January 2006 PHOENIX TEST-LAB GmbH Kˆnigswinkel 10 D32825 Blomberg Germany RE: Certification Application FCC ID: N5GHF5 Please be advised that the following information is to be held confidential on behalf of Brooks Automation (Germany) GmbH: • Schematics • Parts Lists • Block Diagram • Technical Description The application contains technical information which Brooks Automation (Germany) GmbH deems to be trade secrets and proprietary. If made public, the information might be used to the disadvantage of the applicant in the market place. Thank you for your attention to this matter.

External Photos

FCC ID: N5GHF5 FCC ID: N5GHF5 FCC ID: N5GHF5 FCC ID: N5GHF5 FCC ID: N5GHF5 FCC ID: N5GHF5

ID Label/Location Info

FCC ID: N5GHF5

Internal Photos

FCC ID: N5GHF5 FCC ID: N5GHF5 FCC ID: N5GHF5 FCC ID: N5GHF5

Test Report

Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Note: The test data of this report is related only to the individual item which has been tested. This report shall not be reproduced except in full extent without the written approval of the testing laboratory. Test Report No. 50831-060012 (Edition 2) Page 1 of 42 Pages Straubing, 07 March 2006 T E S T - R E P O R T No. 50831-060012 (Edition 2) for HF5X Inductive Tag Reader Applicant: Brooks Automation (Germany) GmbH Test Specifications: FCC Code of Federal Regulations, CFR 47, Part 15, Sections 15.205, 15.207, 15.215 and 15.225 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50831-060012 (Edition 2) Page 2 of 42 Pages Table of Contents 1 Description of the Equipment Under Test (EUT) ........................................................ 3 2 Administrative Data..................................................................................................... 4 3 Identification of the Test Laboratory ........................................................................... 5 4 Summary .................................................................................................................... 6 5 Operation Mode and Configuration of EUT................................................................. 7 6 Measurement Procedures........................................................................................... 9 6.1 Bandwidth Measurements .................................................................................... 9 6.2 Conducted AC Powerline Emission .................................................................... 10 6.3 Radiated Emission Measurement 9 kHz to 30 MHz ........................................... 12 6.4 Radiated Emission in Fully or Semi Anechoic Room.......................................... 14 6.5 Radiated Emission at Open Field Test Site........................................................ 16 6.6 Carrier Frequency Stability ................................................................................. 17 7 Photographs Taken During Testing .......................................................................... 19 8 Test Results .............................................................................................................. 26 8.1 Occupied Bandwidth........................................................................................... 27 8.2 Bandwidth of the Emission ................................................................................. 30 8.3 Designation of Emissions ................................................................................... 32 8.4 Conducted Powerline Emission Measurement 150 kHz to 30 MHz................... 33 8.5 Spectrum Mask................................................................................................... 34 8.6 Radiated Emission Measurement 9 kHz to 30 MHz .......................................... 36 8.7 Radiated Emission Measurement 30 MHz to 1 GHz ......................................... 37 8.8 Carrier Frequency Stability ................................................................................. 38 9 Referenced Regulations ........................................................................................... 41 10 Charts taken during testing ....................................................................................... 42 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50831-060012 (Edition 2) Page 3 of 42 Pages 1 Description of the Equipment Under Test (EUT) General data of EUT Type designation 1 : HF5X Parts 2 : Serial number(s): 0001 Manufacturer: Brooks Automation (Germany) GmbH Type of equipment: Inductive Tag Reader Version: as received FCC ID: Additional parts/accessories: Technical data of EUT Application frequency range: 13.553 - 13.567 MHz Frequency range: 13.553 - 13.567 MHz Operating frequency: 13.56 MHz Type of modulation: ASK Pulse train: --- Pulse width: --- Number of RF-channels: 1 Channel spacing: --- Designation of emissions 3 : 10K0A1D Type of antenna: External Loop Antennas Size/length of antenna: 187 x 145 mm Connection of antenna: detachable not detachable Type of power supply: DC supply Specifications for power supply: nominal voltage: 24.0 V minimum voltage: 20.4 V maximum voltage: 27.6 V 1 Type designation of the system if EUT consists of more than one part. 2 Type designations of the parts of the system, if applicable. 3 Also known as "Class of Emission". Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50831-060012 (Edition 2) Page 4 of 42 Pages 2 Administrative Data Application details Applicant (full address): Brooks Automation (Germany) GmbH Gartenstrafle 19 D-95490 Mistelgau Contact person: Mr. Lothar D ̧ngfelder Contract identification: --- Receipt of EUT: 13 January 2006 Date(s) of test: January 2006 Note(s): --- Report details Report number: 50831-060012 Edition: 2 Issue date: 18 January 2006 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50831-060012 (Edition 2) Page 5 of 42 Pages 3 Identification of the Test Laboratory Details of the Test Laboratory Company name: Senton GmbH EMI/EMC Test Center Address: Aeussere Fruehlingstrasse 45 D-94315 Straubing Germany Laboratory accreditation: DAR-Registration No. DAT-P-171/94-02 FCC test site registration number 90926 Industry Canada test site registration: IC 3050 Contact person: Mr. Johann Roidt Phone: (+49) (0)9421 5522-0 Fax: (+49) (0)9421 5522-99 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50831-060012 (Edition 2) Page 6 of 42 Pages 4 Summary Summary of test results The tested sample complies with the requirements set forth in the Code of Federal Regulations CFR 47, Part 15, Sections 15.205, 15.207, 15.215 and 15.225 of the Federal Communication Commission (FCC). Personnel involved in this report Laboratory Manager: Mr. Johann Roidt Responsible for testing: Mr.…

Text truncated - open the document above for the full version.

Test Setup Photos

Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50831-060012 (Edition 1) Page 20 of 42 Pages Test setup for conducted AC powerline emission measurement Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50831-060012 (Edition 1) Page 21 of 42 Pages Test setup for radiated emission measurement 9 kHz ñ 30 MHz Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50831-060012 (Edition 1) Page 22 of 42 Pages Test setup for radiated emission measurement 9 kHz ñ 30 MHz - continued - Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50831-060012 (Edition 1) Page 23 of 42 Pages Test setup for radiated emission measurement (fully anechoic room) Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50831-060012 (Edition 1) Page 24 of 42 Pages Test setup for radiated emission measurement (open field test site) Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50831-060012 (Edition 1) Page 25 of 42 Pages Test setup for radiated emission measurement (open field test site) - continued -

Contact Information

Applicant

Michael Krolak(Member of the Technical Staff)
[email protected]510-661-5090Fax: 978-262-2500

Technical Contact

Senton GmbHJohann Roidt
[email protected]+49 9421 55220

Aeussere Fruehlingstrasse · Straubing · Germany

Test Firm

TUV SUD Product Service GmbH PS-EMC-STRRainer Heller
[email protected]49-09421-5522-20Fax: 49-09421-5522-99

Technical Specifications

#Rule PartsFrequency RangePower OutputTolerance
115C13.56 MHz - 13.56 MHz-0.0100000000 %
Confidentiality
Long Term

Other Applications from Brooks Automation Inc.

RFID Reader - FCC ID N5GLF40C - Brooks Automation Inc.
N5GLF40C

RFID Reader

Oct 13, 2014

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
RFID Reader - FCC ID N5GLF60C - Brooks Automation Inc.
N5GLF60C

RFID Reader

Jul 09, 2013

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
RFID UHF Reader - FCC ID N5GUF80 - Brooks Automation Inc.
N5GUF80

RFID UHF Reader

Jul 01, 2012

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
RFID UHF Reader - FCC ID N5GUF70 - Brooks Automation Inc.
N5GUF70

RFID UHF Reader

May 30, 2012

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Inductive Tag Reader - FCC ID N5GCFC - Brooks Automation Inc.
N5GCFC

Inductive Tag Reader

Jan 13, 2005

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz