Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
RFM182 / RFM182W Instruction Manual How to operate your fixture Step 1: Set both light fixtures (transmitter and twin Par receiver) to the same house code by turning the dial on the bottom of the sensor head and the bottom of the receiver to the same number. There are 16 different selections Step 2: Move slide switch on bottom of sensor head to “TEST”. Set sensitivity knob to medium (halfway). Step 3: Turn on power to both fixtures. Step 4: Aim sensor head toward desired detection area. Make sure sensor head is positioned with the control switches facing towards the ground and at a 15º down angle. Step 5: Walk across the detection zone at the farthest distance you wish your detector to detect motion. Adjust sensitivity until you get desired results. Step 6: Move slide switch to 4 MIN or 12 MIN (AUTO mode). At dusk your lights will operate in the AUTO setting. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Under Part 15 of the FCC Rules, any changes or modifications to the motion detector described in this instruction sheet that are not expressly approved by Cooper Lighting could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Warning: FCC Regulations state that any unauthorized changes or modifications to this equipment not expressly approved by the manufacturer could void the user's authorization to operate this equipment. How to select your desired feature Mode of Operation Slide switch position How to set power switch Auto Setting (motion activated) Light fixture with motion sensor detects motion and sends an ON signal to receiver. Lights should turn off after 4 or 12 minutes after all motion stops. The transmitter contains a daylight sensor, which only allows lights to come on at night. 4 MIN Or 12 MIN Keep the power on to both fixtures Dusk to Dawn Setting (activated only at night) Lights should stay on from dusk to dawn and then reset to the auto setting next dawn. 4 MIN Or 12 MIN Turn power on and off twice within 3 seconds. Standard Floodlight Setting Lights should stay on continuously both day and night (must be reset manually). TEST Turn power on and off twice within 3 seconds. TEST Setting Lights should turn on when the remote sensor detects motion, both day and night. Lights should turn off after 8 seconds after all motion has stopped. TEST Keep the power on to both fixtures
Voltage regulation 120V 60Hz to DC 24V& 5V Cooper Lighting MODULE: T180AC (Motion detector with RF transmitter) SUBJECT:Block diagram 5V 24V Lamp Load TEST 4 Min Auto 12Min Auto MODE SELECTION SWITCH PIR CONTROL CIRCUIT (PT2621A) 12.8-19.2 Khz CDS SENSOR PIR SENSOR ENCODE CONTROL CIRCUIT TX SEND CIRCUIT 315Mhz Sensitivity Adjust Relay driving CIRCUIT House code Selection 1 to 16
Response to TCB Findings Q: Please explain how the duty-cycle was determined Response: The manufacturer indicated that the maximum worst case scenario would be if the transmitters were made to transmit all "1" 's which would only allow for a maximum 50% duty cycle. Therefore the transmitter was continuously transmitting 1’s during the testing. Q: Please provide external pictures of the transmitter. Response: Supplied.
FCC ID: NCG-T180DC IC: XXXXXXX This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation Cooper Lighting, Peachtree City, GA Made in China XXT180DCXX XXX-XXXX FCC ID: NCG-T180AC IC: XXXXXXX This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation Cooper Lighting, Peachtree City, GA Made in China XXT180DCXX Input: 120 VAC 60Hz, Amps 2.5 XXX-XXXX Outdoor Use Only Suitable for Wet Locations
Theory of Operation Module : T180AC Description: AC power motion sensing transmitter with PAR lamp fixture. T180AC, is a motion sensing transmitter light fixture. It is powered by 120VAC, 60 HZ and can be wall mount or eve mount and is rated for outdoor use only. The module consists of a passive infra-red motion detector, control circuit, relay to switch on the PAR fixture connected to the transmitter, encoder and 315 MHz SAW resonator and utilizes a 22 AWG wire antenna, 245mm in length. The detector has 4 modes of operation: test, auto-4 minutes, auto-12 minutes and manual override; and one sensitivity adjustment for motion detection and one house code selection. The detector also has a built-in photo sensor with dual functions; first is to disable motion detection in auto mode or manual override mode during the day. Secondly, switch the fixture out of manual override at a higher light level. During test mode, if motion is detected, it will turn on its PAR fixture and also send an encoded RF signal, “ON “ command, with carrier frequency of 315MHz to the receiver. The internal timer will time out in 8 seconds after motion ceased. It will then turn off its PAR fixture and send an encoded RF signal,” OFF” command to the receiver. Auto 4 minutes and Auto 12 minutes work the same as test mode except the photo circuit will disable motion detection during the day and the internal timer is either 4 minutes or 12 minutes, depending on the settings, instead of 8 seconds in the test mode. Manual override. During Auto-4 and Auto-12 at night, cutting power off-on-off-on within 2 seconds to the transmitter fixture will force the fixture engaged into manual override mode. The PAR fixture will turn on and stay on until the photo sensing circuit has detected a higher level of ambient light or the same power interruption off-on-off-on occurred in the input. However, the same power interruption off-on-off-on within 3 seconds in test mode will keep the fixture stay on no matter what the day light level is. The transmitter will send “ON” command and “OFF” command to the receiver based on the status of the PAR lamp fixture.
RF Emissions Test Report To Determine Compliance With: FCC, Part 15 Rules and Regulations Model number: T180AC July 23, 2003 Manufacturer: Cooper Lighting 1121 Highway 74 South Peachtree City, GA 30269 EMC Testing Laboratories, Inc. authorizes the above company to reproduce this report provided it is reproduced in its entirety EMC Testing Lab. (770) 781-9228 Test report no. 03-146A2 Page 2 of 2 2 2 2 Contents Section General Information ....................................................................... 1 Test Summary.................................................................................. 2 Standard Reference ........................................................................ 3 Test Method ......................................................................... 4 Radiated Out of Band Emissions Measurements ........................... 5 Fundamental Frequency Radiated Emissions Measurements ........ 6 Conducted Emissions Measurements .............................................. 7 Occupied Bandwidth Measurements .............................................. 8 Voltage Variation ......................................................... 9 EMC Testing Lab. (770) 781-9228 Test report no. 03-146A2 Page 3 of 2 2 2 2 Section 1 General Information Manufacturer: Cooper Lighting 1121 Highway 74 South Peachtree City, GA 30269 Manufacturer representative: Mr. Wai-Shing Ko Equipment covered by this report: Model no.: T180AC Options covered by this report: None Equipment serial no. Prototype Test specifications: To determine compliance with: FCC, Part 15.231, Subpart C Rules and Regulations, Class B Test report number: 03-146A2 Test commenced: May 16, 2003 Test completed: July 23, 2003 Test engineer: Edward Barnes Test Facility: The test facility used to perform these tests is on file with the FCC under registration number 637500 and located at: EMC Testing Laboratories, Inc. 2210 Justin Trail Alpharetta, GA 30004 EMC Testing Lab. (770) 781-9228 Test report no. 03-146A2 Page 4 of 2 2 2 2 Section 2 Test report summary sheet 1 of 2 Summary: Tests Results FCC, Part 15, Class B, Radiated emissions: Pass FCC, Part 15, Class B, Conducted emissions: Pass 1- The product(s) covered by this report was found to comply with the limits indicated in paragraphs 15.109 Subpart B and 15.231, Part 15, Subpart C of the FCC Rules and Regulations. 2- The minimum margin of compliance using peak measurement compared against average limits, was –2.1 dBμv/m at 944.8 Mhz with the antenna in the vertical polarization followed by –2.8 dBμv/m at 944.8 Mhz with the antenna in the horizontal polarization. Product description: The product(s) covered by this report consisted of a power operated transmitter, intended for use with lighting equipment. The transmitter is an intentional radiator operating at 315MHz and transmits when a motion detector detects motion. The transmitter cannot transmit again until no motion is detected from 4 to 12 minutes. After the 4 to 12 minute timer has expired the transmitter is then ready to detect motion again. The transmit duration is 2 seconds maximum (on time). For the purpose of testing, the unit was set to a 51.25% duty cycle. The equipment utilizes a maximum 2 second pulse that occurs at a maximum frequency of once every 4 minutes in normal operation. The enclosure is constructed of plastic in the shape of a semicircle with a 3cm radius and 5cm height and encloses the following components judged as critical: 1. A main board, part no. SMH100-2V8. 2. A transmitter board, part no. SMH100-11V1. 3. A house code board, part no. SMH100-1V3. 4. An encoder board, part no. SMH100-3E EMC Testing Lab. (770) 781-9228 Test report no. 03-146A2 Page 5 of 2 2 2 2 Test report summary sheet 2 of 2 Test configuration: The equipment under test was set-up and configured as specified by the manufacturer. 1- The EUT was connected to the following support peripherals. A) None 2- The EUT was connected to the following cables. A) None Test operation: For all measurements, the equipment under test was and caused to function in a continuous mode of operation for maximum electrical activity as specified by the manufacturer. Specifically, the EUT was put in a 51.25% duty cycle when powered on. Modifications: The following modifications were required to comply with the indicated limits: 1- None Conclusion: With the above indicated modifications, the product(s) covered by this report has been tested and found to comply with the limits indicated in paragraph 15.231 table (b)of the FCC, Part 15, Subpart C Rules and Regulations and all subsequent limits indicated therein for a class B device. Tested by: Reviewed by: Edward Barnes Gene J. Bailey RF Engineer Engineering Manager EMC Testing Laboratories, Inc. EMC Testing Laboratories, Inc. July 23, 2003 July 23, 2003 EMC Testing Lab. (770) 781-9228 Test report no. 03-146A2 Page 6 of 2 2 2 2 Section 2 cont... This page intentionally left blank. (Reserved for future use) EMC Testing Lab. (770) 781-9228 Test report no. 03-146A2 Page 7 of 2 2 2 2 Section 3 STANDARD REFERENCE The following primary standards were used for this test: 1) ANSI C63.4-1992: Method of Measurements of Radio-Noise Emissions from Low- Voltage Electrical and Electronic Equipment in the 9 Khz to 40 Ghz. 2) US Code of Federal Regulations (CFR) 1998: Title 47, Part 15, Radio Frequency Devices, Subpart C, Intentional Radiators. EMC Testing Lab. (770) 781-9228 Test report no. 03-146A2 Page 8 of 2 2 2 2 Section 4 TEST METHOD INTRODUCTION: The product(s) covered by this report were subjected to electromagnetic interference emissions measurements to determine compliance with the FCC, Part 15 requirements. Radiated emissions were measured in accordance with Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 Khz to 40 Ghz, C63.4. MEASUREMENT CALCULATIONS: Radiated Emissions : For radiated emissions measurements, the signal attenuation due t…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 315 MHz - 315 MHz | - |

Motion Detector
Equipment Class
FDS - Part 15 Field Disturbance Sensor
2.4GHz PIR Activated Lighting Camera System
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
PIR Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Lighting Controller
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Electronic Ballast
Equipment Class
8CC - Part 18 Consumer Device