Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Reader ISOMAX IV OPERATION MANUAL Jmj/27Sept2004 Preliminary OPERATION MANUAL RID)))))((( R ISO MAX IV The RID)))))(((® ISO MAX IV is a portable, high-performance Radio Frequency Tag reader. It is designed to read RID)))))(((® and other Tags. This manual describes the use of the Portable Reader ISO MAX IV. The RID)))))(((® ISO MAX IV reader and the RID)))))(((® Tags, are according to ISO Standard 11784/11785 and are DATA products. The RID)))))(((® ISO MAX IV reader and the RID)))))(((® Tags are distributed in the UK by Bayer PLC under the Trademark “Tracer Animal Coder”. RID)))))(((® is an internationally registered Trademark 1 Reader ISOMAX IV OPERATION MANUAL Jmj/27Sept2004 Preliminary I N D E X _________________________________________________________________ 1. Description 2. Operation 2.1. Reading a code 2.1.1. Power ON 2.1.2. Reading a transponder 2.1.3. Code saved to memory 2.1.4. Code read and send to the computer 2.1.5. Transfer of codes to the PC 3. Managing the menu. How to enter into the menu window 3.1.1. Memory functions menu window 3.1.2. Browsing the memory 3.1.3. Clear memory 3.1.4. Set the memory ON / OFF 3.1.5. Select the features memory hit and selected hit 3.1.6. Serial Dump (Download/Upload) the code memorized into a computer 3.2.1. Clock adjust 4. Connection to an Host or PC 4.1. Real time communication 4.2. Download the saved code from the ISOMAX IV and an host. 5. Battery 5.1. Battery indicator 5.2. Recharging the battery 6. Care of your reader 7. Specifications 8. USB installation Appendix: Do you have problems in identifying an animal ? 2 Reader ISOMAX IV OPERATION MANUAL Jmj/27Sept2004 Preliminary 1. Description USB or RS232 communication Accumulator charger plug Menu buttons Power ON & Start Reading button Antenna Display Fig. 1: Outline of the ISO MAX IV reader 3 Reader ISOMAX IV OPERATION MANUAL Jmj/27Sept2004 Preliminary 2. Operation Although the ISO MAX IV was designed for easy use we recommend that you read this manual carefully in order to be familiar with all its useful features. 2.1. Reading a code with ISO MAX IV: 2.1.1. Power ON Make sure that the charger is not connected to the reader. Pass your hand through the handle and use your thumb to push the start button in the top left corner of the panel. Start Fig. 2 The display shows the following window : Battery level Firmware version mem : OFF Fig. 3 This message indicates that the reader is functioning correctly and is ready to read a transponder (tag). “A.x”. informs about the firmware version and is of no importance to the user. Check that the battery level is not empty (the indicator must not be entirely clear). Check if the code memory is enabled or disabled by looking at the tool bar on the bottom of the screen. Mem: OFF Indicates that the transponder codes read will not be saved in the reader memory. 4 Reader ISOMAX IV OPERATION MANUAL Jmj/27Sept2004 Preliminary Mem: ON Indicates that any transponder read will be saved in the memory. The capacity off the memory is 2000 codes with date and time saved with the code number. See chapter 3.1.1. memory functions menu window for more information. 2.1.2. Reading a transponder In order to read, press the start button again. The display will show the following: Fig. 4 *reading* means that your reader is searching for a transponder (tag). According to a specific analysis the reader scans through the different tag types. Place the ISO MAX IV near the tag to be read. If an ISO transponder has been read the display will show the following: Fig. 5 This display indicates that a transponder (tag ) ISO 171784/5 FDX-B or HDX-B with the country code “Austria” and the identification code number ”040” (country code) “ 098101065557” has been found. 5 Reader ISOMAX IV OPERATION MANUAL Jmj/27Sept2004 Preliminary If other code FDX-A are read the display will show the type or category of this transponder. IDI: 7 012 345 97F Fig. 6 Type displayed are: - IDI for Destron, Avid, PETRAC and similar - TVN for Trovan, AEG, and similar If no transponder has been found, the display will show the following (“Tag not found”): Fig. 7 The code will be displayed for about 90 seconds, then the ISO MAX IV will switch off automatically in order to save battery life. Note: If the display indicates NO ANIMAL CODE: This means that the transponder was read and has the same structure code as the ISO 11785 but is not an animal transponder. (Animal bit not set). To avoid number coincidence the ISOMAX IV will not accept to show the number. Please contact Datamars SA for more information. 2.1.3. Code saved to memory If the mem is OFF the code will not be memorized. In order to memorize the code switch mem to ON. Please see chapter 3.1.1. memory functions menu window for more information. When the memory is full (max. 2000 codes) the display will show: “Memory full” and no more reading will be allowed. It is possible to read more code by (unloading) clearing the memory or by disabling the memory (mem: OFF). 2.1.4. Code read and send to the computer All code read are send to the communication line USB or RS232. Please refer to chapter @@@@@ for more information. 6 Reader ISOMAX IV OPERATION MANUAL Jmj/27Sept2004 Preliminary 2.1.5. Transfer of codes to the PC All the code saved in the memory can be send to the computer by a button the ISOMAX IV menu. Please refer to chapter 3.1.6. SERIAL DUMP. All code read are sent to the communication link instantaneously. Please refer to chapter 4.1. Real time communication for more information. 7 Reader ISOMAX IV OPERATION MANUAL Jmj/27Sept2004 Preliminary 3. Managing the menu. How to enter into the menu window Power on the reader by pushing the start button. (Please ref. To chapter 2.1.1). Push the round button to enter into the menu. Left button Menu button (ENTER) Fig. 8 Down button The display will show the menu window: Fig. 9 Note: If the button menu is pushed and no action is done the main the ISOMAX IV will switch to the main window after a few seconds. …
Text truncated - open the document above for the full version.
FCC ID: NDXISOMAXIV Company: DATAMARS SA Address: Via ai prati, CH-6930 bedano-Lugano Responsible Person: Mauro Di Domenico Product: ISOMAX IV Type Designation: z1. We declare that the above named model was supplied with the maximum configuration to the accredited test laboratory. z2. We authorize the accredited test laboratory MIKES BABT PRODUCT SERVICE GmbH, Ohmstraße 2-3, 94342 Straßkirchen, Germany to act on our behalf on all approval and notification matters concerning the above named model, especially for testings, applications, approval and notification procedures. Nevertheless we keep the responsiblity regarding certification and notification matters. We declare that the accredited testlab MIKES BABT PS GmbH is allowed to forward all information related to the approval project to the applied notified body ,spectrum management authorities and agents. Bedano, 06 October 2004 Mauro Di Domenico R&D Engineer RF - Identification Technology Datamars SA via ai Prati CH-6930 Bedano-Lugano Switzerland Phone+41 91 935 73 80 Fax +41 91 945 03 30 www.datamars.com Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 29 th September 2004 Dear Sir or Madam: We, Datamars SA, via ai Prati, CH-6930 Bedano-Lugano, hereby authorize MIKES BABT Product Service GmbH, Ohmstrasse 2-4, 94342 Strasskirchen, Germany to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by MIKES BABT Product Service GmbH on our behalf shall have the same affect as acts of our own. This authorization is valid until further written notice from Datamars SA Sincerely, Mauro Di Domenico R&DEngineer DATAMARSSA Tel: 004191-9357380 Fax: 004191-9450330
FCC ID: NDXISOMAXIV File No. T25258-00-00AA, page 5 of 26 MIKES BABT Product Service GmbH x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 Rev. No. 9.3 3 EQUIPMENT UNDER TEST 3.1 Photo documentation of the EuT FCC ID: NDXISOMAXIV File No. T25258-00-00AA, page 6 of 26 MIKES BABT Product Service GmbH x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 Rev. No. 9.3
RF - Identification Technology 5. FCC ID Label The ISOMAXIV label is laser printed on Heavy Duty Label produced by Avery Zweckform. Description: L4774 White Label for outdoor use Waterproof, resistant UV, oil, dirt and tearing Temperature Resistant from -20°C to +80° C For more information http://www.avery-zweckform.com/ 6. Photo showing the Location of the label on the ISOMAX IV Label Confidential 3 of 8 28.09.2004/MD
FCC ID: NDXISOMAXIV File No. T25258-00-00AA, page 7 of 26 MIKES BABT Product Service GmbH x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 Rev. No. 9.3 FCC ID: NDXISOMAXIV File No. T25258-00-00AA, page 8 of 26 MIKES BABT Product Service GmbH x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 Rev. No. 9.3 FCC ID: NDXISOMAXIV File No. T25258-00-00AA, page 9 of 26 MIKES BABT Product Service GmbH x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 Rev. No. 9.3 FCC ID: NDXISOMAXIV File No. T25258-00-00AA, page 10 of 26 MIKES BABT Product Service GmbH x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 Rev. No. 9.3 FCC ID: NDXISOMAXIV File No. T25258-00-00AA, page 11 of 26 MIKES BABT Product Service GmbH x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 Rev. No. 9.3 FCC ID: NDXISOMAXIV File No. T25258-00-00AA, page 12 of 26 MIKES BABT Product Service GmbH x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 Rev. No. 9.3 FCC ID: NDXISOMAXIV File No. T25258-00-00AA, page 13 of 26 MIKES BABT Product Service GmbH x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 Rev. No. 9.3 FCC ID: NDXISOMAXIV File No. T25258-00-00AA, page 14 of 26 MIKES BABT Product Service GmbH x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 Rev. No. 9.3
FCC ID: NDXISOMAXIV File No. T25258-00-00AA, page 1 of 22 MIKES BABT Product Service GmbH x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 Rev. No. 9.3 TTI - P-G 089 / 94-11 DAT - P-011 / 91-02 EMI -- T E S T R E P O R T Test Report No. : T25258-00-00AA 22. October 2004 ______________________________________________________________________________________________ Date of issue Type / Model : ISOMAX IV Model Description : Portable Reader Applicant : Datamars SA Address : Via ai prati CH-6930 Bedano-Lugano, Switzerland Manufacturer : Datamars SA Address : Via ai prati CH-6930 Bedano-Lugano, Switzerland Licence holder : Datamars SA Address : Via ai prati CH-6930 Bedano-Lugano, Switzerland Test Result according to the standards listed in clause 1 test standards: POSITIVE The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permission of the test laboratory. FCC ID: NDXISOMAXIV File No. T25258-00-00AA, page 2 of 22 MIKES BABT Product Service GmbH x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 Rev. No. 9.3 Contents 1 TEST STANDARDS 3 2 SUMMARY 4 3 EQUIPMENT UNDER TEST 5 3.1 PHOTO DOCUMENTATION OF THE EUT 5 3.2 POWER SUPPLY SYSTEM UTILISED 11 3.3 SHORT DESCRIPTION OF THE EQUIPMENT UNDER TEST (EUT) 11 4 TEST ENVIRONMENT 12 4.1 ADDRESS OF THE TEST LABORATORY 12 4.2 ENVIRONMENTAL CONDITIONS 12 4.3 STATEMENT OF THE MEASUREMENT UNCERTAINTY 12 4.4 MEASUREMENT PROTOCOL FOR FCC, VCCI AND AUSTEL 12 5 TEST CONDITIONS AND RESULTS 14 5.1 CONDUCTED EMISSIONS 14 5.2 FIELD STRENGTH OF THE FUNDAMENTAL WAVE 15 5.3 SPURIOUS EMISSIONS (MAGNECTIC FIELD) 9 KHZ – 30 MHZ 17 5.4 RADIATED EMISSIONS (ELECTRIC FIELD) 30 MHZ – 1 GHZ 19 5.5 EMISSION BANDWIDTH 21 6 USED TEST EQUIPMENT AND ACCESSORIES 22 FCC ID: NDXISOMAXIV File No. T25258-00-00AA, page 3 of 22 MIKES BABT Product Service GmbH x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 Rev. No. 9.3 1 TEST STANDARDS The tests were performed according to following standards: FCC Rules and Regulations Part 15 Subpart C- Intentional Radiators (October 01, 2003) Part 15, Subpart C, Section 15.209(a) Radiated emissions, general requirements FCC ID: NDXISOMAXIV File No. T25258-00-00AA, page 4 of 22 MIKES BABT Product Service GmbH x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 Rev. No. 9.3 2 SUMMARY GENERAL REMARKS: None FINAL ASSESSMENT: The equipment under test fulfills the EMC requirements cited in clause 1 test standards. Date of receipt of test sample : acc. to storage records of MBPS Testing commenced on : 07. October 2004 Testing concluded on : 18. October 2004 Checked by: Tested by: _______________________________ _____________________________ Günter Mikes Anton Altmann Dipl. Ing.(FH) Dipl. Ing.(FH) FCC ID: NDXISOMAXIV File No. T25258-00-00AA, page 5 of 22 MIKES BABT Product Service GmbH x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 Rev. No. 9.3 3 EQUIPMENT UNDER TEST 3.1 Photo documentation of the EuT FCC ID: NDXISOMAXIV File No. T25258-00-00AA, page 6 of 22 MIKES BABT Product Service GmbH x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 Rev. No. 9.3 FCC ID: NDXISOMAXIV File No. T25258-00-00AA, page 7 of 22 MIKES BABT Product Service GmbH x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 Rev. No. 9.3 FCC ID: NDXISOMAXIV File No. T25258-00-00AA, page 8 of 22 MIKES BABT Product Service GmbH x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 Rev. No. 9.3 FCC ID: NDXISOMAXIV File No. T25258-00-00AA, page 9 of 22 MIKES BABT Product Service GmbH x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 Rev. No. 9.3 FCC ID: NDXISOMAXIV File No. T25258-00-00AA, page 10 of 22 MIKES BABT Product Service GmbH x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 Rev. No. 9.3 FCC ID: NDXISOMAXIV File No. T25258-00-00AA, page 11 of 22 MIKES BABT Product Service GmbH x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 Rev. No. 9.3 3.2 Power supply system utilised Power supply voltage : 11.1 V / DC 3.3 Short description of the Equipment under Test (EuT) The EuT ISOMAX IV is a transponder Reader working on 134.2 kHz. It has different channels to receive different frequencies and demodulator in order to read 4 different types of transponder. Number of tested samples: 1 Serial number: Sample No 2 EuT operation mode: The equipment under test was operated during the measurement under the following conditions: - TX reading mode EuT configuration: (The CDF filled by the applicant can be viewed at the test laboratory.) The following peripheral devices and interface cables were connected during the measurements: - Battery charger Model : SB-151BOF-11 - USB cable Model : 1m shielded - Model : - Model : - Model : - Model : FCC ID: NDXISOMAXIV File No. T25258-00-00AA, page 12 of 22 MIKES BABT Product Service GmbH x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 Rev. No. 9.3 4 TEST ENVIRONMENT 4.1 Address of the test laboratory MIKES BABT Product Service GmbH Ohmstrasse 2-4 94342 Strasskirchen Germany 4.2 Environmental conditions During the measurement the environmental conditions were within the listed ranges: Temperature: 15-35 ° C Humidity: 30-60 % Atmospheric pressure: 86-106 kPa 4.3 Statement of the measurement uncertainty The data and results referenced in this document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated for all measurements listed in this test report acc. to CISPR 16-4-2 /11.2003 „Uncertainties, statistics and limit modelling – Uncerta…
Text truncated - open the document above for the full version.
FCC ID: NDXISOMAXIV File No. T25258-00-00AA, page 15 of 22 MIKES BABT Product Service GmbH x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 Rev. No. 9.3 5.2 Field strength of the fundamental wave For test instruments and accessories used see section 6 Part CPR 1. 5.2.1 Description of the test location Test location: OATS1 5.2.2 Photo documentation of the test set-up 5.2.3 Description of Measurement The magnetic field strength from the EuT is measured in the frequency range of 9 kHz to 30 MHz using a tuned receiver and a shielded loop antenna. The antenna was positioned 3, 10 or 30 meters horizontally from the EuT. Measurements have been made in all three orthogonal axes and the shielded loop antenna was rotated to locate the maximum of the emissions. The final level, expressed in dBμV/m, is arrived at by taking the reading from the EMI receiver (Level dBμV) and adding the antenna correction factor and cable loss factor (Factor dB) to it. This result then has to be compared with the relevant FCC limit. The resolution bandwidth during the measurement is as follows: 9 kHz – 150 kHz: ResBW: 200 Hz 150 kHz – 30 MHz: ResBW: 9 kHz Example: Frequency Level + Factor = Level Limit = Delta (MHz) (dBμV) (dB) (dBμV/m) (dBμV/m) (dB) 1.705 5 + 20 = 25 30 = 5 FCC ID: NDXISOMAXIV File No. T25258-00-00AA, page 17 of 22 MIKES BABT Product Service GmbH x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 Rev. No. 9.3 5.3 Spurious emissions (Magnectic field) 9 kHz – 30 MHz For test instruments and accessories used see section 6 Part SER 1. 5.3.1 Description of the test location Test location: OATS1 5.3.2 Photo documentation of the test set-up 5.3.3 Description of Measurement Spurious emissions from the EuT are measured in the frequency range of 9 kHz to 30 MHz using a tuned receiver and a shielded loop antenna. The antenna was positioned 3, 10 or 30 meters horizontally from the EuT. Measurements have been made in all three orthogonal axes and the shielded loop antenna was rotated to locate the maximum of the emissions. The final level, expressed in dBμV/m, is arrived at by taking the reading from the EMI receiver (Level dBμV) and adding the antenna correction factor and cable loss factor (Factor dB) to it. This result then has to be compared with the relevant FCC limit. The resolution bandwidth during the measurement is as follows: 9 kHz – 150 kHz: ResBW: 200 Hz 150 kHz – 30 MHz: ResBW: 9 kHz Example: Frequency Level + Factor = Level Limit = Delta (MHz) (dBμV) (dB) (dBμV/m) (dBμV/m) (dB) 1.705 5 + 20 = 25 30 = 5
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.134 MHz - 0.134 MHz | - |
RFID Scanner with Bluetooth Low Energy
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzNINA-B4
Equipment Class
DTS - Digital Transmission SystemActivetag Edge Gateway
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
RFID handheld reader for animal indentification
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
RFID handheld reader for livestock applications
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral