GREEN POWERLINK On-Line Energy Management Solution User Manual © Copyright 2012 The information contained herein is subject to change without notice. This document contains proprietary information, which is protected by copyright. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent. Feb. 2012 All Versions TABLE OF CONTENTS INTRODUCTION...................................................................... 2 HARDWARE FEATURES ......................................................... 3 INSTALLATION....................................................................... 5 Wireless Setup Range.......................................................................... 5 Install Smart Socket............................................................................ 5 Install Smart Power Strip ................................................................... 6 Install CT Smart Meter in the circuit breaker panel............................ 7 Prepare the electrical circuit breaker................................................................... 7 Connect the CT clamps & voltage wires to the curren & voltage input terminals..................................................................................... 8 Wiring Diagram .................................................................................................... 9 ENERGY MANAGEMENT GATEWAY INITIAL SETUP.............. 11 Browse and access Gateway within intranet network ...................... 11 Energy Gateway and Smart Metering Devices pairing instructions... 18 Change User ID and Password ......................................................... 22 Network Setup ................................................................................. 22 Electricity Cost and CO2 Emission Setup.......................................... 23 Outgoing Server Setup...................................................................... 24 Reset the Energy Gateway to Factory Default................................... 24 Reset to factory default from energy gateway web server................ 25 Browse and access Gateway from internet....................................... 25 GREEN POWERLINK On-Line Energy Management Solution V1.0 1 INTRODUCTION Thank you for purchasing the GREEN POWERLINK online energy management solution, an innovative product which is designed to manage home electricity usage efficiently and reduce home electricity bill. In an effort to reduce your electricity bills, why not first check out what appliance uses most energy in your home. The GREEN POWERLINK online energy management allows you to take control of home electricity usage while saving you money in the process. With GREEN POWERLINK, you can see how much electricity you are using and with greater awareness you’ll become more energy efficient. Fully educated with the critical energy information, you are naturally motivated to adopt new energy saving habits and reduce harmful carbon emission for our environment. The GREEN POWERLINK is the total solution for green inspiration, energy conservation, and surge protection for your everyday life. GREEN POWERLINK On-Line Energy Management Solution V1.0 2 GREEN POWERLINK On-Line Energy Management Solution V1.0 3 HARDWARE FEATURES ZigBee Tracking Smart SocketZigBee Tracking Smart Strip Surge Protected Outlet 180J Surge Protection ZigBee Link: 2.4GHz (IEEE 802.15.4) Transmission Time: 6 seconds Wireless Range: 100 ft in open area ZigBee Function: Router ZigBee Profile: Smart Energy 1.0 ZigBee Cluster: Simple Metering Green Surge Protected LED Indicator Manual ON/OFF Button w/ Green LED Indicator Security: AES 128 bits (Optional) Meet IEC 62053‐21 class I standard (1~1.5%) 6 Surge Protected Outlets 540J Surge Protection Red Grounded Fault LED Indicator R9P136A600R9P624NI00 ZigBee Tracking Smart SocketZigBee Tracking Smart Strip Transmission Time: 6 seconds ZigBee Function: Router ZigBee Cluster: Simple Metering Installation type: 1‐phase & 3‐wire CT Meter Input Voltage:100~240V CT Meter Input Current: 60A CT Meter Frequency: 50/60Hz CT Meter Accuracy: <1% at PF=1 Power Supply: Power acquired from electrical meter ZigBee Link: 2.4GHz (IEEE 802.15.4) Wireless Range: 100 ft in open area ZigBee Profile: Smart Energy 1.0 Security: AES 128 bits (Optional) Link up to 9 PowerLink energy tracking devices ZigBee Function: Coordinator Proprietary remote outlet on/off control Remote web browsing management & power on/off control Remote real time Cost, KWH, CO2 usage information display RJ45 Ethernet Port Connection Power Supply: AC/DC adaptor (included) GREEN POWERLINK On-Line Energy Management Solution V1.0 4 GREEN POWERLINK On-Line Energy Management Solution V1.0 5 INSTALLATION Wireless Setup Range The energy gateway and smart socket/strip/CT meter communicate with wireless technology. To ensure the communication with no interruption, please locate and setup energy gateway, smart socket/strip/CT meter within 100 Ft of range. Install Smart Socket The single outlet smart socket allows the user to track electricity consumption of individual home appliance and protect it against surge and voltage spikes. 1. Plug in the smart socket to a powered AC outlet. 2. Plug in the appliance into the smart socket outlet. 3. The outlet power can be manually turned ON/OFF by pressing the “Manual ON/OFF” button on the smart socket. You may also control the outlet power remotely by using the energy monitor (see the operation instruction). 4. Perform initial energy monitor and smart socket pair up (see the operation instruction). PROTECTED LED LIGHT This LED light illuminates to indicate that the surge protection is active and protecting equipments from power surges. Manual ON/OFF” button M9PC020000M9PG040000 Install Smart Power Strip The smart power strip allows the user to track electricity consumption of group home appliances in the same area and protect it against surge and voltage spikes. 1…
Text truncated - open the document above for the full version.
For the following information Ref. File No.: C1M1207027 Product ZigBee Tracking Smart Strip Model Number M9PG040000 Applicant Powertech Industrial Co Ltd Manufacturer Dongguan Quan Sheng Electric Co., Ltd. Standards FCC CFR 47 Part 15 Subpart B/Oct. 2011 and CISPR 22/1997 (Class B Limit) We hereby certify that the above product has been tested by us and complied with the FCC official limits. These products might be marketed at the US accordance to FCC Rule based on the standard 47 CFR Part 2 and Part 15 Class B Equipment Regulations. The test was performed accordance to the procedures from ANSI C63.4-2003. The test data & results are issued on the test report no. EM-F1010646. Signature _____________________________ Leon Liu/Deputy General Manager Date: Aug. 13, 2012 Test Laboratory: AUDIX Technology Corporation, EMC Department NVLAP Lab Code: 200077-0 FCC OET Designation: TW1004 Web Site: www.audixtech.com The statement is based on a single evaluation of one sample of the above-mentioned products. It does not imply an assessment of the whole production and does not permit the use of the test lab logo. NVLAP Lab Code 200077-0
SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 3.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Revised wording (obsolete) 1.0 2.0 Sept–25-2007 Updated company template (current) 2.0 3.0 Jan-31-2012 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 3.0 Aug. 28, 2012 To: SIEMIC, INC. 775 Montague Expressway, Milpitas, CA 95035 USA Dear Sir/Madam, Re: Project and Product Certification Representative Authorization Letter We, Powertech Industrial Co Ltd. hereby authorize SIEMIC, INC. to act as a Certification Body for certifying for the following project(s): Product Name: ZigBee Tracking Smart Strip Model Name: M9PG040000 We affirm that between SIEMIC and Powertech Industrial Co Ltd., any difference in understanding, including test plan, measurement methods, applicable standards and relevant procedures and processes have been resolved prior to commencement of testing activities. Sincerely, Powertech Industrial Co Ltd. 10F, No. 407, Chung Shan Rd., Sec 2 Chung Ho City, Taipei Hsien, 235 Taiwan
SCS-F19: Confidentiality Request Letter Page 1 of 2 Rev 3.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Confidentiality Request Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 (obsolete) 1.0 2.0 August – 11 - 2008 Updated company template & Added text box (current) 2.0 3.0 Jan-31-2012 SCS-F19: Confidentiality Request Letter Page 2 of 2 Rev 3.0 Aug. 28, 2012 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Subject: Permanent Confidentiality Request for FCC ID: NHS-M9PG04 We hereby request confidential treatment of information accompanying this application as outlined below: - Block Diagram - Schematics - Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Powertech Industrial Co Ltd. 10F, No. 407, Chung Shan Rd., Sec 2 Chung Ho City, Taipei Hsien, 235 Taiwan
Powertech Industrial Co Ltd ZigBee Tracking Smart Strip FCC ID : NHS-M9PG04 EUT External Photos Photo 1 General Appearance (Front View) Photo 2 General Appearance (Back View) Powertech Industrial Co Ltd ZigBee Tracking Smart Strip FCC ID : NHS-M9PG04 Photo 3 General Appearance (Front and Side View) Photo 4 General Appearance (Back and Side View) Powertech Industrial Co Ltd ZigBee Tracking Smart Strip FCC ID : NHS-M9PG04 Photo 5 General Appearance (Side View)
Powertech Industrial Co Ltd ZigBee Tracking Smart Strip FCC ID : NHS-M9PG04 ID Label Location z Label Placement Location (Back View of EUT) ID Label Placement Location Powertech Industrial Co Ltd ZigBee Tracking Smart Strip FCC ID : NHS-M9PG04 z ID Label Format
Powertech Industrial Co Ltd ZigBee Tracking Smart Strip FCC ID : NHS-M9PG04 EUT Internal Photos Photo 6 Internal View (Removed Cover) Photo 7 Internal View (Main Board, Front View) Powertech Industrial Co Ltd ZigBee Tracking Smart Strip FCC ID : NHS-M9PG04 Photo 8 Internal View (Main Board, Back View) Photo 9 Internal View (RF Board) Powertech Industrial Co Ltd ZigBee Tracking Smart Strip FCC ID : NHS-M9PG04 Photo 10 Internal View (RF Board, Removed Cover) Photo 11 Internal View (LED Control Board, Front View) Powertech Industrial Co Ltd ZigBee Tracking Smart Strip FCC ID : NHS-M9PG04 Photo 12 Internal View (LED Control Board, Back View)
FCC ID: NHS-M9PG04 Page 1 of 46 AUDIX Technology Corporation Report No.: EM-F1010645 APPLICATION FOR CERTIFICATION On Behalf of Powertech Industrial Co., Ltd. ZigBee Tracking Smart Strip Model No.M9PG040000 FCC IDNHS-M9PG04 Prepared for : Powertech Industrial Co., Ltd. 10F, No. 407, Chung Shan Rd., Sec 2 Chung Ho City, Taipei Hsien, 235 Taiwan Prepared by : AUDIX Technology Corporation EMC Department No. 53-11, Dingfu, Linkou Dist., New Taipei City 244, Taiwan Tel : (02) 2609-9301, 2609-2133 Fax: (02) 2609-9303 File Number C1M1207027 Report Number EM-F1010645 Date of Test Jul. 30 ~ Aug. 31, 2012 Date of Report Aug. 31, 2012 FCC ID: NHS-M9PG04 Page 2 of 46 AUDIX Technology Corporation Report No.: EM-F1010645 TABLE OF CONTENTS Description Page TEST REPORT CERTIFICATION .......................................................................................................3 1. GENERAL INFORMATION .........................................................................................................4 1.1. Description of Device (EUT).................................................................................................................. 4 1.2. Tested Supporting System Details .......................................................................................................... 5 1.3. Description of Test Facility .................................................................................................................... 6 1.4. Measurement Uncertainty....................................................................................................................... 7 2. POWERLINE CONDUCTED EMISSION MEASUREMENT ..................................................8 2.1. Test Equipment ....................................................................................................................................... 8 2.2. Block Diagram of Test Setup.................................................................................................................. 8 2.3. Powerline Conducted Emission Limit (§15.207)....................................................................................8 2.4. Operating Condition of EUT .................................................................................................................. 9 2.5. Test Procedure ........................................................................................................................................ 9 2.6. Powerline Conducted Emission Measurement Results........................................................................... 9 3. RADIATED EMISSION MEASUREMENT ..............................................................................12 3.1. Test Equipment ..................................................................................................................................... 12 3.2. Block Diagram of Test Setup................................................................................................................ 12 3.3. Radiated Emission Limits (§15.209) .................................................................................................... 14 3.4. Fundamental Frequency Limits [§15.249(a)] .......................................................................................14 3.5. Operating Condition of EUT ................................................................................................................ 14 3.6. Test Procedure ...................................................................................................................................... 15 3.7. Radiated Emission Measurement Test Results .....................................................................................15 4. DUTY CYCLE FACTOR .............................................................................................................42 4.1. Test Equipment ..................................................................................................................................... 42 4.2. Block Diagram of Test Setup................................................................................................................ 42 4.3. Test Results........................................................................................................................................... 42 5. DEVIATION TO TEST SPECIFICATIONS..............................................................................44 6. PHOTOGRAPHS...........................................................................................................................45 6.1. Photos of Powerline Conducted Emission Measurement ..................................................................... 45 6.2. Photos of Radiated Emission Measurement at Semi-Anechoic Chamber ............................................ 46 FCC ID: NHS-M9PG04 Page 3 of 46 AUDIX Technology Corporation Report No.: EM-F1010645 TEST REPORT CERTIFICATION Applicant Powertech Industrial Co., Ltd. Manufacturer Dongguan Quan Sheng Electric Co., Ltd. EUT Description ZigBee Tracking Smart Strip FCC ID NHS-M9PG04 (A) Model No. M9PG040000 (B) Serial No. N/A (C) Power Supply DC 7.5V (D) Test Voltage AC 120V/60Hz (Via I.T.E Power Supply) Measurement Procedure Used: FCC RULES AND REGULATIONS PART 15 SUBPART C, Oct. 2011 (FCC CFR 47 Part 15C, §15.207, §15.249, §15.209) AND ANSI C63.4/2003 The device described above was tested by AUDIX Technology Corporation to determine the maximum emission levels emanating from the device. The maximum emission levels were compared to the FCC Part 15 subpart C limits. The measurement results are contained in this test report and AUDIX Technology Corporation is assumed full responsibility for the accuracy and completeness of these measurements. Also, this report shows that the EUT to be technically compliant with the FCC official limits. This report applies to above tested sample only. This report shall not be reproduced in part without written approval of AUDIX Technolo…
Text truncated - open the document above for the full version.
FCC ID: NHS-M9PG04 Page 45 of 46 AUDIX Technology Corporation Report No.: EM-F1010645 6. PHOTOGRAPHS 6.1. Photos of Powerline Conducted Emission Measurement FRONT VIEW OF CONDUCTED MEASUREMENT SIDE VIEW OF CONDUCTED MEASUREMENT FCC ID: NHS-M9PG04 Page 46 of 46 AUDIX Technology Corporation Report No.: EM-F1010645 6.2. Photos of Radiated Emission Measurement at Semi-Anechoic Chamber 6.2.1. For Frequency Range 30MHz~1GHz 6.2.2. For Frequency Above 1GHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | - |

Zigbee Module
Equipment Class
DTS - Digital Transmission System
Mobile Accessory - Breathalyzer
Equipment Class
DTS - Digital Transmission System
APPS Power Control Timer Strip
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
ZigBee Tracking Energy Monitor
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
ZigBee Tracking Smart Socket
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter