FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Powertech Industrial Co Ltd/
  3. NHS-R9P016

NHS-R9P016ZigBee Tracking Energy Monitor

Powertech Industrial Co Ltd
ZigBee Tracking Energy Monitor - FCC ID NHS-R9P016 - Powertech Industrial Co Ltd
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Sep 05, 2012
Application Purpose
Original Equipment
Date of Application
Sep 05, 2012
Equipment Note
ZigBee Tracking Energy Monitor
Frequency Range
2405.00000000 - 2480.00000000
Company
Powertech Industrial Co Ltd
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

GREEN POWERLINK ZIGBEE IN-HOME ENERGY MONITOR SOLUTION User Manual © Copyright 2012 The information contained herein is subject to change without notice. This document contains proprietary information, which is protected by copyright. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent. Feb. 2012 All Versions TABLE OF CONTENTS INTRODUCTION ----------------------------------------------------------- 2 HARDWARE FEATURES --------------------------------------------------- 3 INSTALLATION ----------------------------------------------------------- 5 Wireless Setup Range ------------------------------------------------- 5 Install Smart Socket --------------------------------------------------- 5 Install Smart Power Strip---------------------------------------------- 6 Install CT Smart Meter in the circuit breaker panel--------------------- 7 Prepare the electrical circuit breaker----------------------------- 8 Connect the CT clamps & voltage wires to the current & voltage input terminals----------------------------- 9 Wiring Diagram--------------------------------------------------- 10 INITIAL SETUP------------------------------------------------------------ 12 Install Battery in Energy Monitor--------------------------------------- 12 Use an AC/DC Adapter (Included)--------------------------------------- 12 Wall Mount the Energy Monitor----------------------------------------- 12 Perform Energy Monitor Initial Setup----------------------------------- 13 Currency and Electricity Setup------------------------------------ 13 Carbon Emission Setup--------------------------------------------- 14 OPERATION--------------------------------------------------------------- 15 Initial Smart Metering Devices and Energy Monitor pair up------------- 15 Energy Monitor Display and Control------------------------------------- 15 Change channels on the energy monitor--------------------------- 16 Turn ON/OFF the outlet of the smart socket----------------------- 16 View real time and projection energy consumption---------------- 17 View Real Time energy information for the channel--------------- 17 View projection energy information for the selected channel------ 18 View accumulation energy consumption--------------------------- 19 Activate the energy accumulation mode for the selected channel-- 19 View total day energy accumulation for the selected channel------ 20 View total month energy accumulation for the selected channel--- 21 View total year energy accumulation for the selected channel----- 22 Exit energy accumulation mode for the selected channel---------- 23 Reset the Energy Monitor to Factory Default------------------------------ 23 Powerlink Essential Energy Monitor User Manual V1.0 1 INTRODUCTION Thank you for purchasing the GREEN POWERLINK Energy Saving Solution, an innovative product which is designed to manage home electricity usage efficiently and reduce home electricity bill. In an effort to reduce your electricity bills, why not first check out what appliance uses most energy in your home. The New GREEN POWERLINK Energy Monitor allows you to take control of home electricity usage while saving you money in the process. With GREEN POWERLINK, you can see how much electricity you are using and with greater awareness you’ll become more energy efficient. Fully educated with the critical energy information, you are naturally motivated to adopt new energy saving habits and reduce harmful carbon emission for our environment. The GREEN POWERLINK is the total solution for green inspiration, energy conservation, and surge protection for your everyday life. Powerlink Essential Energy Monitor User Manual V1.0 2 Powerlink Essential Energy Monitor User Manual V1.0 3 HARDWARE FEATURES ZigBee Tracking Energy MonitorZigBee Tracking Smart Socket Link up to 9 PowerLink energy tracking devices ZigBee Link: 2.4GHz (IEEE 802.15.4) Transmission Time: 6 seconds Wireless Range: 100 ft in open area ZigBee Function: Router ZigBee Profile: Smart Energy 1.0 ZigBee Cluster: Simple Metering Green Surge Protected LED Indicator Manual ON/OFF Button w/ Green LED Indicator Security: AES 128 bits (Optional) Meet IEC 62053‐21 class I standard (1~1.5%) Surge Protected Outlet 180J Surge Protection R9P0160000R9P136A600 ZigBee Link: 2.4GHz (IEEE 802.15.4) Wireless Range: 100 ft in open area Display instant energy consum ption in Watts, Cost, CO2 Display forecasted energy usage in KWH, Cost, CO2 by day/month/year Display accumulated energy usage by day/month/year Surge counter displays the frequency of surge occurrences Energy Display Power Supply : 9V AC/DC adaptor (included) INSTALLATION Wireless Setup Range The energy monitor and smart socket/strip/CT meter communicate with wireless technology. To ensure the communication with no interruption, please locate and setup energy monitor, smart socket/strip/CT meter within 100 Ft of range. Install Smart Socket The single outlet smart socket allows the user to track electricity consumption of individual home appliance and protect it against surge and voltage spikes. 1. Plug in the smart socket to a powered AC outlet. 2. Plug in the appliance into the smart socket outlet. 3. The outlet power can be manually turned ON/OFF by pressing the “Manual ON/OFF” button on the smart socket. You may also control the outlet power remotely by using the energy monitor (see the operation instruction). 4. Perform initial energy monitor and smart socket pair up (see the operation instruction). Powerlink Essential Energy Monitor User Manual V1.0 4 Powerlink Essential Energy Monitor User Manual V1.0 5 ZigBee Tracking Smart Meter 6 Surge Protected Outlets 540J Surge Protection Green Surge Protected LED Indicator Red Grounded Fault LED Indicator Transmission Time: 6 seconds ZigBee Function: Router ZigBee Cluster: Simple Metering Manual ON/OFF Button w/ Green LED Indicator Meet IEC 62053‐21 class I standard (1~1.5%) ZigBee Link: 2.4GHz (IEEE…

Text truncated - open the document above for the full version.

Cover Letter(s)

SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 3.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Revised wording (obsolete) 1.0 2.0 Sept–25-2007 Updated company template (current) 2.0 3.0 Jan-31-2012 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 3.0 Aug. 15, 2012 To: SIEMIC, INC. 775 Montague Expressway, Milpitas, CA 95035 USA Dear Sir/Madam, Re: Project and Product Certification Representative Authorization Letter We, Powertech Industrial Co Ltd. hereby authorize SIEMIC, INC. to act as a Certification Body for certifying for the following project(s): Product Name: ZigBee Tracking Energy Monitor Model Name: R9P0160000 We affirm that between SIEMIC and Powertech Industrial Co Ltd., any difference in understanding, including test plan, measurement methods, applicable standards and relevant procedures and processes have been resolved prior to commencement of testing activities. Sincerely, George Lee / Director Powertech Industrial Co Ltd. 10F, No. 407, Chung Shan Rd., Sec 2 Chung Ho City, Taipei Hsien, 235 Taiwan

Cover Letter(s)

SCS-F19: Confidentiality Request Letter Page 1 of 2 Rev 3.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Confidentiality Request Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 (obsolete) 1.0 2.0 August – 11 - 2008 Updated company template & Added text box (current) 2.0 3.0 Jan-31-2012 SCS-F19: Confidentiality Request Letter Page 2 of 2 Rev 3.0 Aug. 15, 2012 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Subject: Permanent Confidentiality Request for FCC ID: NHS-R9P016 We hereby request confidential treatment of information accompanying this application as outlined below: - Block Diagram - Schematics - Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, George Lee / Director Powertech Industrial Co Ltd. 10F, No. 407, Chung Shan Rd., Sec 2 Chung Ho City, Taipei Hsien, 235 Taiwan

External Photos

Powertech Industrial Co Ltd ZigBee Tracking Energy Monitor FCC ID : NHS-R9P016 EUT External Photos Photo 1 General Appearance (Front and Side View) Photo 2 General Appearance (Back and Side View) Powertech Industrial Co Ltd ZigBee Tracking Energy Monitor FCC ID : NHS-R9P016 Photo 3 I.T.E. Power Supply General Appearance (Front and Side View) Photo 4 I.T.E. Power Supply General Appearance (Back and Side View)

ID Label/Location Info

Powertech Industrial Co Ltd ZigBee Tracking Energy Monitor FCC ID : NHS-R9P016 ID Label Location z Label Placement Location (Back View of EUT) z ID Label Format ID Label Placement Location

Internal Photos

Powertech Industrial Co Ltd ZigBee Tracking Energy Monitor FCC ID : NHS-R9P016 EUT Internal Photos Photo 5 Internal View (Removed Battery Cover) Photo 6 Internal View (Removed Cover) Powertech Industrial Co Ltd ZigBee Tracking Energy Monitor FCC ID : NHS-R9P016 Photo 7 Internal View (Main Board, Front View) Photo 8 Internal View (Main Board, Back View) Powertech Industrial Co Ltd ZigBee Tracking Energy Monitor FCC ID : NHS-R9P016 Photo 9 Internal View (RF Board) Photo 10 Internal View (Display)

Test Report

FCC ID: NHS-R9P016 Page 1 of 32 AUDIX Technology Corporation Report No.: EM-F1010709 APPLICATION FOR CERTIFICATION On Behalf of Powertech Industrial Co., Ltd. ZigBee Tracking Energy Monitor Model No.R9P0160000 FCC IDNHS-R9P016 Prepared for : Powertech Industrial Co., Ltd. 10F, No. 407, Chung Shan Rd., Sec 2 Chung Ho City, New Taipei City, 235 Taiwan, R.O.C. Prepared by : AUDIX Technology Corporation EMC Department No. 53-11, Dingfu, Linkou Dist., New Taipei City 244, Taiwan, R.O.C. Tel : (02) 2609-9301, 2609-2133 Fax: (02) 2609-9303 File Number C1M1208219 Report Number EM-F1010709 Date of Test Aug. 23 ~ 28, 2012 Date of Report Aug. 28, 2012 FCC ID: NHS-R9P016 Page 2 of 32 AUDIX Technology Corporation Report No.: EM-F1010709 TABLE OF CONTENTS Description Page TEST REPORT CERTIFICATION .......................................................................................................3 1. GENERAL INFORMATION .........................................................................................................4 1.1. Description of Device (EUT).................................................................................................................. 4 1.2. Tested Supporting System Details .......................................................................................................... 5 1.3. Description of Test Facility .................................................................................................................... 5 1.4. Measurement Uncertainty....................................................................................................................... 5 2. POWERLINE CONDUCTED EMISSION MEASUREMENT ..................................................6 2.1. Test Equipment ....................................................................................................................................... 6 2.2. Block Diagram of Test Setup.................................................................................................................. 6 2.3. Powerline Conducted Emission Limit (§15.207)....................................................................................6 2.4. Operating Condition of EUT .................................................................................................................. 7 2.5. Test Procedure ........................................................................................................................................ 7 2.6. Powerline Conducted Emission Measurement Results........................................................................... 7 3. RADIATED EMISSION MEASUREMENT ..............................................................................10 3.1. Test Equipment ..................................................................................................................................... 10 3.2. Block Diagram of Test Setup................................................................................................................ 10 3.3. Radiated Emission Limits (§15.209) .................................................................................................... 12 3.4. Fundamental Frequency Limits [§15.249(a)] .......................................................................................12 3.5. Operating Condition of EUT ................................................................................................................ 12 3.6. Test Procedure ...................................................................................................................................... 13 3.7. Radiated Emission Measurement Test Results .....................................................................................13 4. DUTY CYCLE FACTOR .............................................................................................................28 4.1. Test Equipment ..................................................................................................................................... 28 4.2. Block Diagram of Test Setup................................................................................................................ 28 4.3. Test Results........................................................................................................................................... 28 5. DEVIATION TO TEST SPECIFICATIONS..............................................................................30 6. PHOTOGRAPHS...........................................................................................................................31 6.1. Photos of Powerline Conducted Emission Measurement ..................................................................... 31 6.2. Photos of Radiated Emission Measurement at Semi-Anechoic Chamber ............................................ 32 FCC ID: NHS-R9P016 Page 3 of 32 AUDIX Technology Corporation Report No.: EM-F1010709 TEST REPORT CERTIFICATION Applicant Powertech Industrial Co., Ltd. Manufacturer Dongguan Quan Sheng Electric Co., Ltd. EUT Description ZigBee Tracking Energy Monitor FCC ID NHS-R9P016 (A) Model No. R9P0160000 (B) Serial No. N/A (C) Power Supply DC 7.5V (D) Test Voltage AC 120V/60Hz (Via I.T.E. Power Supply) Measurement Procedure Used: FCC RULES AND REGULATIONS PART 15 SUBPART C, Oct. 2011 (FCC CFR 47 Part 15C, §15.207, §15.249, §15.209) AND ANSI C63.4/2003 The device described above was tested by AUDIX Technology Corporation to determine the maximum emission levels emanating from the device. The maximum emission levels were compared to the FCC Part 15 subpart C limits. The measurement results are contained in this test report and AUDIX Technology Corporation is assumed full responsibility for the accuracy and completeness of these measurements. Also, this report shows that the EUT to be technically compliant with the FCC official limits. This report applies to above tested sample only. This report shall not be reproduced in part without written appro…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: NHS-R9P016 Page 31 of 32 AUDIX Technology Corporation Report No.: EM-F1010709 6. PHOTOGRAPHS 6.1. Photos of Powerline Conducted Emission Measurement FRONT VIEW OF CONDUCTED MEASUREMENT BACK VIEW OF CONDUCTED MEASUREMENT FCC ID: NHS-R9P016 Page 32 of 32 AUDIX Technology Corporation Report No.: EM-F1010709 6.2. Photos of Radiated Emission Measurement at Semi-Anechoic Chamber 6.2.1. For Frequency Range 30MHz~1GHz 6.2.2. For Frequency Above 1GHz

Contact Information

Applicant

George Lee(Manager)
[email protected]886 2-8221-5588Fax: 886 2-8221-5680

Test Firm

Audix Technology CorporationLeon Liu
[email protected]822-609-2133Fax: 886 2 26099303

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz-
Confidentiality
Long Term

Other Applications from Powertech Industrial Co Ltd

Zigbee Module - FCC ID NHS-EM3585 - Powertech Industrial Co Ltd
NHS-EM3585

Zigbee Module

Dec 23, 2015

Equipment Class

DTS - Digital Transmission System
Mobile Accessory - Breathalyzer - FCC ID NHS-A02A - Powertech Industrial Co Ltd
NHS-A02A

Mobile Accessory - Breathalyzer

Dec 17, 2014

Equipment Class

DTS - Digital Transmission System
APPS Power Control Timer Strip - FCC ID NHS-R9P627 - Powertech Industrial Co Ltd
NHS-R9P627

APPS Power Control Timer Strip

May 27, 2013

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
ZigBee Tracking Smart Socket - FCC ID NHS-M9PC02 - Powertech Industrial Co Ltd
NHS-M9PC02

ZigBee Tracking Smart Socket

Sep 03, 2012

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
ZigBee Tracking Smart Strip - FCC ID NHS-M9PG04 - Powertech Industrial Co Ltd
NHS-M9PG04

ZigBee Tracking Smart Strip

Sep 03, 2012

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter