FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Powertech Industrial Co Ltd/
  3. NHS-R1N001T

NHS-R1N001TRadio Transmitter

Powertech Industrial Co Ltd
Radio Transmitter - FCC ID NHS-R1N001T - Powertech Industrial Co Ltd
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Apr 19, 2004
Application Purpose
Original Equipment
Date of Application
Apr 19, 2004
Equipment Note
Radio Transmitter
Frequency Range
319.00000000 - 319.95000000
Company
Powertech Industrial Co Ltd
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

โ†—

Cover Letter(s)

โ†—

External Photos

โ†—

ID Label/Location Info

โ†—

Internal Photos

โ†—

Test Report

โ†—

Test Setup Photos

โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

CAUTION: Any changes of modifications not expressly approved by the grantee of this device could void the users authority to operate the equipment.

Cover Letter(s)

10F, NO. 403, CHUNG SHAN RD., TEL: 886- 2- 8221- 5588 SEC. 2, CHUNG HO CITY, FAX: 886- 2- 5680 & 8221- 5681 TAIPEI HSIEN, TAIWAN WEB: WWW.POWER-TECH.COM.TW Request for Confidentiality Federal Communications Commission Authorization and Evaluation Division Sub.: Confidentiality Request regarding application for certification of FCC ID: NHS -R1N001T Pursuant to Sections 0.457 and 0.459 of the Commissionโ€™s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: l Schematics l Part List l Block diagram l Operational description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, POWERTECH INDUSTRIAL CO., LTD.

External Photos

External Photos of Transmitter 1/8 FCC ID: NHS-R1N001T ; CANADA IC: 3653A-R1N001T Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 External Photos of Transmitter 2/8 FCC ID: NHS-R1N001T ; CANADA IC: 3653A-R1N001T Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 External Photos of Transmitter 3/8 FCC ID: NHS-R1N001T ; CANADA IC: 3653A-R1N001T Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 External Photos of Transmitter 4/8 FCC ID: NHS-R1N001T ; CANADA IC: 3653A-R1N001T Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

ID Label/Location Info

LABEL Format: LABEL Size: 20 x 29 mm LABEL Position: FCC ID: NHS-R1N001T CANADA IC: 3653A-R1N001T THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1)This device may not cause harmful interference, and (2)This device must accept any interference received, including interference that may cause undesired operation Replacement Battery 12V THE NCC Inc. 1 8007303707 Main in China

Internal Photos

Internal Photos of Transmitter 5/8 FCC ID: NHS-R1N001T ; CANADA IC: 3653A-R1N001T Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Internal Photos of Transmitter 6/8 FCC ID: NHS-R1N001T ; CANADA IC: 3653A-R1N001T Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Internal Photos of Transmitter 7/8 FCC ID: NHS-R1N001T ; CANADA IC: 3653A-R1N001T Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Internal Photos of Transmitter 8/8 FCC ID: NHS-R1N001T ; CANADA IC: 3653A-R1N001T Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report

Test Report ------------------------------------------------------------------------------- 1/17 Report No.: G2115438 (TX) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Report No. G2115438 Specifications FCC Part 15.231, Certification Test Method ANSI C63.4 1992 Applicant POWERTECH INDUSTRIAL CO., LTD. Applicant 10F, No. 403, Chang Shan Road, Sec. 2, Chung Ho City, address Taipei Hsien, Taiwan, R.O.C. Items tested Transmitter Model No. R1N001T EUT Condition Engineering sample; Pre-production; Final production (Sample # G21438) Results Compliance (As detailed within this report) Date 04/08/2004 (month / day / year) (Sample received) 04/08/2004 to 04/16/2004 (Test) Prepared by Project Engineer (Jack Tsai) Authorized by General Manager (Frank Tsai) Issue date April 19, 2004 (month / day / year) Modifications None Tested by Training Research Co., Ltd. Office at No. 255, Nan Yang Street, Shijr, Taipei Hsien 221, Taiwan Chamber at 1F, No. 255, Nan Yang Street, Shijr, Taipei Hsien 221, Taiwan Conditions of issue: (1) This test report shall not be reproduced except in full, without written approval of TRC. And the test result contained within this report only relate to the sample submitted for testing. (2) This test report, measurements made by TRC are traceable to the NIST only Conducted and Radiated Method. FCC ID: NHS-R1N001T Test Report ------------------------------------------------------------------------------- 2/17 Report No.: G2115438 (TX) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Table of Contents CHAPTER 1 GENERAL.................................................................................3 1.1 INTRODUCTION.....................................................................3 1.2 DESCRIPTION OF EUT..........................................................3 1.3 DESCRIPTION OF SUPPORT EQUIPMENT................................3 1.4 TEST PROCEDURE.................................................................4 1.5 LOCATION OF THE TEST SITE...............................................4 1.6 GENERAL TEST CONDITION..................................................4 CHAPTER 2 TRANSMITTER DUTY CYCLE MEASUREMENTS........5 2.1 TEST CONDITION AND SETUP...............................................5 2.2 LIST OF TEST INSTRUMENTS.................................................5 2.3 TEST INSTRUMENTS CONFIGURATION..................................6 2.4 TEST RESULT.......................................................................6 CHAPTER 3 TRANSMITTER BANDWIDTH MEASUREMENTS, FCC PART 15.231(C).............................................................8 3.1 TEST CONDITION & SETUP...................................................8 3.2 TEST RESULT.......................................................................8 CHAPTER 4 CONDUCTED EMISSIONS MEASUREMENTS..............10 4.1 TEST CONDITION................................................................10 4.2 TEST RESULT.....................................................................10 CHAPTER 5 RADIATED EMISSIONS MEASUREMENTS..................11 5.1 GENERAL CONFIGURATION................................................11 5.2 TEST CONDITION AND SETUP.............................................11 5.3 LIST OF TEST INSTRUMENTS...............................................14 5.4 TEST INSTRUMENTS CONFIGURATION................................15 5.5 TEST RESULT OF RADIATED EMISSIONS.............................16 Table 1 Radiated Emissions of Horizontal for 30MHz to 3.2GHz [X-axis]......................16 Table 2 Radiated Emissions of Vertical for 30MHz to 3.2GHz [Y-axis]..........................17 Test Report ------------------------------------------------------------------------------- 3/17 Report No.: G2115438 (TX) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Chapter 1 GENERAL 1.1 Introduction The following measurement report is submitted on behalf of applicant in support of an International Periodic Radiator certification with Part 2 Subpart J and Part 15 Subpart A and C of the Commission's Rules and Regulations. 1.2 Description of EUT EUT : Transmitter Model No. : R1N001T FCC ID : NHS-R1N001T CANADA IC : 3653A-R1N001T Frequency Range : 319.00MHz ~ 319.95MHz Operating Frequency : 319.50MHz Modulation Skill : AM Power Type : Powered by 12V/23A battery (L1028 battery * 1) The fundamental frequency of transmitter emitted is due to a press on button of the EUT. The emitting time of fundamental frequency is less than 5 seconds pursuant to FCC Part 15.231(a). There are security codes for avoiding the possibility of duplicating codes in adjacent systems. The coding must be matching with the companion receiver. The device is setting test mode by applicant. During testing, the EUT was operated at continuous transmission mode. The EUT was adjusted at a position, which transmits the maximum emission. 1.3 Description of Support Equipment No support equipment: The EUT itself forms a system. No support equipment is requited for its normal operation Test Report ------------------------------------------------------------------------------- 4/17 Report No.: G2115438 (TX) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 1.4 Test Procedure All measurements contained in this report were performed according to the techniques described in measurement procedure of ANSI C63.4 1992 section 13 1.5 Location of the Test Site The radiated emissions measurements required by the rules were performed on the three-meter, Anechoic Chamber (FCC Registration Number: 93906) maintained by Training Research Co., Ltd. 1F, No. 255, Nan Yang Street, Hsi-chih, Taipei Hsien 221, Taiwan, R.O.C. Complete description and measurement data have been placed on file with the commission. The conducted power line emissions tests and other test items were performed in a anechoic chamber also located at Training Research Co., Ltd. 1F, No. 255, Nan Yang Street, Hsi-chih, Taipei Hsien 2โ€ฆ

Text truncated - open the document above for the full version.

Test Setup Photos

Test Setup Photos ------------------------------------------------------------------------- 1/1 FCC ID: NHS-R1N001T ; CANADA IC: 3653A-R1N001T Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Radiated Test Setup Placement: The Test configuration of Rear view of X-axis The Test configuration of Rear view of Y-axis

Contact Information

Applicant

George Lee(Manager)
[email protected]886 2-8221-5588Fax: 886 2-8221-5680

Test Firm

Training Research Co., LtdJack Tsai
[email protected]886-2-26935155Fax: 886-2-26934440

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231319 MHz - 319.95 MHz-
Confidentiality
Long Term

Other Applications from Powertech Industrial Co Ltd

Zigbee Module - FCC ID NHS-EM3585 - Powertech Industrial Co Ltd
NHS-EM3585

Zigbee Module

Dec 23, 2015

Equipment Class

DTS - Digital Transmission System
Mobile Accessory - Breathalyzer - FCC ID NHS-A02A - Powertech Industrial Co Ltd
NHS-A02A

Mobile Accessory - Breathalyzer

Dec 17, 2014

Equipment Class

DTS - Digital Transmission System
APPS Power Control Timer Strip - FCC ID NHS-R9P627 - Powertech Industrial Co Ltd
NHS-R9P627

APPS Power Control Timer Strip

May 27, 2013

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
ZigBee Tracking Energy Monitor - FCC ID NHS-R9P016 - Powertech Industrial Co Ltd
NHS-R9P016

ZigBee Tracking Energy Monitor

Sep 05, 2012

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
ZigBee Tracking Smart Socket - FCC ID NHS-M9PC02 - Powertech Industrial Co Ltd
NHS-M9PC02

ZigBee Tracking Smart Socket

Sep 03, 2012

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter