
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
APPENDIX FCC Warning Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly ap proved by the party responsible for compliance could void the user’s authority to operate the equipment.
10F, NO. 403, CHUNG SHAN RD., TEL: 886- 2- 8221- 5588 SEC. 2, CHUNG HO CITY, FAX: 886- 2- 5680 & 8221- 5681 TAIPEI HSIEN, TAIWAN WEB: WWW.POWER-TECH.COM.TW Request for Confidentiality Federal Communications Commission Authorization and Evaluation Division Sub.: Confidentiality Request regarding application for certification of FCC ID: NHS -R1N003 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: l Schematics l Part List l Block diagram l Operational description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, POWERTECH INDUSTRIAL CO., LTD.
External Photos of Transmistter 1/8 FCC ID: NHS-R1N003 ; CANADA IC: 3653A-R1N003 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 External Photos of Transmistter 2/8 FCC ID: NHS-R1N003 ; CANADA IC: 3653A-R1N003 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 External Photos of Transmistter 3/8 FCC ID: NHS-R1N003 ; CANADA IC: 3653A-R1N003 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
LABEL Format: LABEL Size: 18 x 13 mm LABEL Position: Model: R1N003 FCC ID: NHS-R1N003 CANADA IC: 3653A-R1N003 The device complies with Part15 of the FCC Rules. See instruction manual. LABEL
Internal Photos of Transmistter 4/8 FCC ID: NHS-R1N003 ; CANADA IC: 3653A-R1N003 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Internal Photos of Transmistter 5/8 FCC ID: NHS-R1N003 ; CANADA IC: 3653A-R1N003 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Internal Photos of Transmistter 6/8 FCC ID: NHS-R1N003 ; CANADA IC: 3653A-R1N003 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Internal Photos of Transmistter 7/8 FCC ID: NHS-R1N003 ; CANADA IC: 3653A-R1N003 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Internal Photos of Transmistter 8/8 FCC ID: NHS-R1N003 ; CANADA IC: 3653A-R1N003 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Test Report -------------------------------------------------------------------------------1/17 Report No.: G2115344 (TX) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Report No.G2115344 SpecificationsFCC Part 15.231, Certification Test MethodANSI C63.4 1992 ApplicantPOWERTECH INDUSTRIAL CO., LTD. Applicant10F, No. 403, Chang Shan Road, Sec. 2, Chung Ho City, addressTaipei Hsien, Taiwan, R.O.C. Items testedTransmitter Model No.R1N003 EUT Condition Engineering sample; Pre-production;Final production (Sample # G21344) ResultsCompliance (As detailed within this report) Date03/17/2004 (month / day / year) (Sample received) 03/17/2004 to 03/24/2004(Test) Prepared byProject Engineer (Jack Tsai) Authorized byGeneral Manager (Frank Tsai) Issue dateApril 2, 2004(month / day / year) ModificationsNone Tested by Training Research Co., Ltd. Office atNo. 255, Nan Yang Street, Shijr, Taipei Hsien 221, Taiwan Chamber at1F, No. 255, Nan Yang Street, Shijr, Taipei Hsien 221, Taiwan Conditions of issue: (1)This test report shall not be reproduced except in full, without written approval of TRC. And the test result contained within this report only relate to the sample submitted for testing. (2)This test report, measurements made by TRC are traceable to the NIST only Conducted and Radiated Method. ϪʳFCC ID: NHS-R1N003 Test Report -------------------------------------------------------------------------------2/17 Report No.: G2115344 (TX) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Table of Contents CHAPTER 1 GENERAL................................................................................. 3 1.1 I NTRODUCTION..................................................................... 3 1.2 D ESCRIPTION OF EUT .......................................................... 3 1.3 D ESCRIPTION OF SUPPORTEQUIPMENT................................ 3 1.4 T ESTPROCEDURE................................................................. 4 1.5 L OCATION OF THE TESTSITE............................................... 4 1.6 G ENERALTESTCONDITION.................................................. 4 CHAPTER 2 TRANSMITTER DUTY CYCLE MEASUREMENTS........ 5 2.1 T ESTCONDITION AND SETUP............................................... 5 2.2 L IST OF TESTINSTRUMENTS................................................. 5 2.3 T ESTINSTRUMENTSCONFIGURATION.................................. 6 2.4 T ESTRESULT....................................................................... 6 CHAPTER 3 TRANSMITTER BANDWIDTH MEASUREMENTS, FCC PART 15.231(C) ............................................................. 8 3.1 T ESTCONDITION&SETUP................................................... 8 3.2 T ESTRESULT....................................................................... 8 CHAPTER 4 CONDUCTED EMISSIONS MEASUREMENTS .............. 10 4.1 T ESTCONDITION................................................................ 10 4.2 T ESTRESULT..................................................................... 10 CHAPTER 5 RADIATED EMISSIONS MEASUREMENTS .................. 11 5.1 G ENERALCONFIGURATION................................................ 11 5.2 T ESTCONDITION AND SETUP............................................. 11 5.3 L IST OF TESTINSTRUMENTS............................................... 14 5.4 T ESTINSTRUMENTSCONFIGURATION................................ 15 5.5 T ESTRESULT OF RADIATEDEMISSIONS............................. 16 Table 1 Radiated Emissions of Horizontal for 30MHz to 3.2GHz [Z-axis] ...................... 16 Table 2 Radiated Emissions of Vertical for 30MHz to 3.2GHz [Z-axis] .......................... 17 Test Report -------------------------------------------------------------------------------3/17 Report No.: G2115344 (TX) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Chapter 1 GENERAL 1.1 Introduction The following measurement report is submitted on behalf of applicant in support of an International Periodic Radiator certification with Part 2 Subpart J and Part 15 Subpart A and C of the Commission's Rules and Regulations. 1.2 Description of EUT EUT:Transmitter Model No.:R1N003 FCC ID:NHS-R1N003 Frequency Range:319.00MHz ~ 319.95MHz Operating Frequency :319.5MHz Modulation Skill:FSK Power Type:Powered by 12V battery (L1028 battery * 1) The fundamental frequency of transmitter emitted is due to a EUT is lying on the wooden table.The emitting time of fundamental frequency is less than 5 seconds pursuant to FCC Part 15.231(a). There are security codes for avoiding the possibility of duplicating codes in adjacent systems. The coding must be matching with the companion receiver. The device is setting test mode by applicant. During testing, the EUT was operated at continuous transmission mode. The EUT was adjusted at a position, which transmits the maximum emission. 1.3 Description of Support Equipment No support equipment: The EUT itself forms a system. No support equipment is requited for its normal operation Test Report -------------------------------------------------------------------------------4/17 Report No.: G2115344 (TX) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 1.4 Test Procedure All measurements contained in this report were performed according to the techniques described in measurement procedure of ANSI C63.4 1992 section 13 1.5 Location of the Test Site The radiated emissions measurements required by the rules were performed on the three-meter,Anechoic Chamber (FCC Registration Number: 93906)maintained by Training Research Co., Ltd. 1F, No. 255, Nan Yang Street, Hsi-chih, Taipei Hsien 221, Taiwan, R.O.C. Complete description and measurement data have been placed on file with the commission. The conducted power line emissions tests and other test items were performed in a anechoic chamber also located at Training Research Co., Ltd. 1F, No. 255, Nan Yang Street, Hsi-chih, Taipei Hsien 221, Taiwan, R.O.C.Training Research Co.,…
Text truncated - open the document above for the full version.
Test Setup Photos ------------------------------------------------------------------------- 1/1 FCC ID: NHS-R1N003 ; CANADA IC: 3653A-R1N003 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Radiated Test Setup Placement: The Test configuration of Front view of Z-axis The Test configuration of Rear view of Z-axis
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 319 MHz - 319.95 MHz | - |

Zigbee Module
Equipment Class
DTS - Digital Transmission System
Mobile Accessory - Breathalyzer
Equipment Class
DTS - Digital Transmission System
APPS Power Control Timer Strip
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
ZigBee Tracking Energy Monitor
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
ZigBee Tracking Smart Socket
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter