Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Wirel ess Home Appliance Timer Remote Control Kit R9P-120 R9P-121 R9P-007 R9P-202 R9P-403 R9P-616 User’s Manual All V er sions Service Center in USA Company’s name: Haowell Technology & Consulting, Inc. Address: 415 Cloverdale Ln. Walnut, CA 91789-2028 phone no: 909-859-5150 Fax no: 909-468-4660 Contact person: Shannon Chang E-mail: [email protected] © Copyright 2010 The information contained herein is subject to change without notice. This document contains proprietary information, which is protected by copyright. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent. February 2010 Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user authority to operate the equipment. NOTE : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is needed. Consult the dealer or an experienced radio/TV technician for help. Operating Instruction - Outlet Adaptor 1. Plug the outlet adaptor into a powered 125VAC wall outlet. 2. Plug the fixture / appliances you wish to control into 1 outlet wall tap / wall tap plus or the remote outlet of the 2-outlets wall tap plus or yard stake. 3. Turn the mechanical power switch (electrical power switch is not applicable) of the fixture / appliance to the ON position. 4. Use the timer remote control to set timer and control the fixture/appliance (see the operating instruction – timer remote control in below). IMPORTANT: ● Outdoor use outlet adaptor is recommended plugged into a GFCI-protected outlet. ● Outdoor use outlet adaptor is suitable for damp locations. Not for water i mmersion or for use where directly exposed to water. ● Yard stake outlet adaptor should be installed above ground level so it will not fill up with water when raining or snowing. Always unplug and remove the devices from the yard stake when raining or snowing. MANUAL ON/OFF AND LEARNING FUNCTION OF THE OUTLET ADAPTER Note: This button on the outlet adapter serves as manual ON/OFF and Learning functions. Manual ON/OFF function If you have lost your remote timer control, you can still manually turn on/off the remote outlet on the outlet adaptor. 1. To manually turn on the fixture/appliance, press the MANUAL ON/OFF button on the outlet adaptor once. The red LED indicator of the outlet adaptor and the fixture / appliance that plug in the outlet adapter will then turn ON as well. INTRODUCTION THANK YOU for purchasing Wireless Home Appliance Timer Remote Control Kit, you can remotely control indoor or outdoor fixtures and appliances from up to 100ft away (in open space). Having your holiday lighting or appliances turned ON & OFF is just as easy as few clicks on the timer remote control. Our product can conveniently help to change your house into an easy home automation style. OPERATING INSTRUCTIONS NOTE: There are five types of Wireless Home Appliance Timer Remote Control Kit available that best suits your needs. The timer remote control and outlet adaptor may vary depending on the kit model purchased. Indoor Use R9P-120 1-Outlet Wall Tap with timer remote control 1-Outlet Wall Tap Plus with timer remote control 2-Outlets Wall Tap Plus (1 always on / 1 remote outlet) with timer remote control 4-Outlets Yard Stake (2 always on / 2 remote outlets) with timer remote control 6-Outlets Yard Stake (2 always on / 4 remote outlets) with timer remote control R9P-121R9P-202R9P-403R9P-616 Outdoor Use Versions V1.0 2 Versions V1.0 1 2. To manually turn off the fixture/appliance, press once the MANUAL ON/OFF button on the outlet adaptor. The red LED indicator of the outlet adaptor and the fixture/appliance that plug in the outlet adapter will then turn ON as well. Learning function – for timer remote control and outlet adaptor NOTE: The timer remote control and the outlet adaptor in the kit are pre-paired and ready to use. If you purchase solely outlet adaptor (must be one of above model), you can pair the exiting timer remote control with the new purchase outlet adaptor. 1. Hold the timer remote control close to the outlet adaptor. 2. Press the learning button (manual ON/OFF button) on the outlet adaptor at least 5 seconds until the red LED indicator light flashes and goes into learning mode, then release the button. 3. Within 15 seconds, press both ON and OFF buttons on the timer remote control once to sync with the outlet adaptor. 4. If the outlet adaptor has successfully learned the code from the timer remote control, the red LED indicator will go from flashing light to solid light, then off afterward. 5. Check to see if learning is successful by pressing on and off buttons on the timer remote control to switch ON and OFF the outlet adaptor. 6. Repeat steps 2~5 if learning is not successful. Operating Instruction – Timer Remote Control In open space, the timer remote control has a wireless range up to 100 feet* to control the outlet adaptor. *Actual range may vary depending on environment condition, interference and building materials. To tur…
Text truncated - open the document above for the full version.
External photo of EUT
FCC ID Label Location
Internal photo of EUT Antenna
FCC ID. : NHS-R9P007 Report No.: TS10020022-EME Page 1 of 17 EMC TEST REPORT Report No. : TS10020022-EME Model No. : R9P007 Issued Date : Feb. 22, 2010 Applicant: Powertech Industrial Co., Ltd. 10F, No. 407, Chung Shan Rd., Sec. 2, Chung Ho City, Taipei Hsien, Taiwan Test Method/ Standard: 47 CFR FCC Part 15.231 & ANSI C63.4 2003 Test By: Intertek Testing Services Taiwan Ltd. No. 11, Lane 275, Ko-Nan 1 Street, Chia-Tung Li, Shiang-Shan District, Hsinchu City, Taiwan It may be duplicated completely for legal use with the allowance of the applicant. It shall not be reproduced except in full, without the written approval of Intertek Laboratory. The test result(s) in this report only applies to the tested sample(s). The test report was prepared by: Sign on File Shirla Hsiao / Officer These measurements were taken by: Sign on File Rex Liao / Engineer The test report was reviewed by: Name Jacky Chen Title Engineer FCC ID. : NHS-R9P007 Report No.: TS10020022-EME Page 2 of 17 Table of Contents Summary of Tests ............................................................................................................. 3 1. General information...................................................................................................... 4 1.1 Identification of the EUT........................................................................................ 4 1.2 Additional information about the EUT ................................................................... 5 1.3 Antenna description ................................................................................................ 5 2. Test specifications.........................................................................................................6 2.1 Test standard ........................................................................................................... 6 2.2 Operation mode ...................................................................................................... 6 2.3 Test equipment........................................................................................................ 7 3. Radiated emission test FCC 15.231 (b) ........................................................................ 8 3.1 Operating environment ........................................................................................... 8 3.2 Test setup & procedure ........................................................................................... 8 3.3 Radiated emission limit ........................................................................................ 10 3.3.1 Fundamental and harmonics emission limits..................................................... 10 3.3.2 General radiated emission limit ..........................................................................11 3.4 Calculation of Average Factor .............................................................................. 12 3.5 Radiated emission test data FCC 15.231 .............................................................. 15 3.5.1 Measurement results: frequencies equal to or less than 1 GHz ......................... 15 3.5.2 Measurement results: frequencies above 1GHz ................................................ 16 4. Measured bandwidth FCC 15.231(C)......................................................................... 17 FCC ID. : NHS-R9P007 Report No.: TS10020022-EME Page 3 of 17 Summary of Tests Wireless Home Appliance Timer Remote Control Kit -Model: R9P007 FCC ID: NHS-R9P007 Test Reference Results Radiated Emission test 15.231(b), 15.209 Pass Measured bandwidth 15.231(c) Pass FCC ID. : NHS-R9P007 Report No.: TS10020022-EME Page 4 of 17 1. General information 1.1 Identification of the EUT Product: Wireless Home Appliance Timer Remote Control Kit Model No.: R9P007 FCC ID.: NHS-R9P007 Frequency Range: 433.92 MHz Channel Number: Single channel Frequency of Each Channel: 433.92 MHz Type of Modulation: ASK Power Supply: DC 12 V from battery Power Cord: N/A Sample Received: Feb. 02, 2010 Test Date(s): Feb. 08, 2010 ~ Feb. 09, 2010 Note 1: This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Note 2: When determining the test conclusion, the Measurement Uncertainty of test has been considered. FCC ID. : NHS-R9P007 Report No.: TS10020022-EME Page 5 of 17 1.2 Additional information about the EUT The EUT is a Wireless Home Appliance Timer Remote Control Kit and transmitted by manual setting. The transmission will stop once released the switch and was defined as information technology equipment. For more detail features, please refer to User's manual as file name “Installation guide.pdf” 1.3 Antenna description The EUT uses a permanently connected antenna. Antenna Gain : -20 dBi max Antenna Type : PCB printed antenna Connector Type : N/A FCC ID. : NHS-R9P007 Report No.: TS10020022-EME Page 6 of 17 2. Test specifications 2.1 Test standard The EUT was performed according to the procedures in FCC Part 2.1053 and the requirement in FCC Part 15 Subpart C Section 15.231. 2.2 Operation mode The EUT was transmitted continuously during the test. FCC ID. : NHS-R9P007 Report No.: TS10020022-EME Page 7 …
Text truncated - open the document above for the full version.
Radiated Emission Test set-up photo
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |

Zigbee Module
Equipment Class
DTS - Digital Transmission System
Mobile Accessory - Breathalyzer
Equipment Class
DTS - Digital Transmission System
APPS Power Control Timer Strip
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
ZigBee Tracking Energy Monitor
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
ZigBee Tracking Smart Socket
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter