Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
User Manual All Versions © Copyright 2010 The information contained herein is subject to change without notice. The information contained herein is subject to change without notice. This document contains proprietary information, which is protected by copyright. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent. April 2010 R9P014 / R9P125 / R9P602 GREEN POWERLINK Smart Energy Monitoring & Surge Protecting Solution INTRODUCTION----------------------------------------------------- 2FEATURES AND FUNCTIONS---------------------------------------- 3INSTALLATION------------------------------------------------------ 8 Wireless Setup Range-------------------------------------------- 8 Install Wall Tap Surge Protector---------------------------------- 8 Install Strip Surge Protector------------------------------------- 8 INITIAL SETUP------------------------------------------------------ 9 Install Battery in Energy Monitor--------------------------------- 9 Use an AC/DC Adapter (Optional)--------------------------------- 10 Wall Mount the Energy Monitor-----------------------------------10 Perform Energy Monitor Initial Setup-----------------------------10 Date & Time Setup----------------------------------------------------- 10 Currency Setup---------------------------------------------------------12 Electricity Rate Setup---------------------------------------------------12 Carbon Emission Setup-------------------------------------------------13 Audible Alarm Setup----------------------------------------------------14 OPERATION--------------------------------------------------------- 14 Energy Monitor Display Mode------------------------------------ 14 Channel Mode (Default page)------------------------------------------ 15 Energy Mode----------------------------------------------------------- 16 Cost Mode-------------------------------------------------------------- 17 CO2 Mode-------------------------------------------------------------- 18 Event Mode-------------------------------------------------------------18 Surge Alert Mode-------------------------------------------------------20 Advance Setup Instruction------------------------------------------ 23 Delete Event Data Setup------------------------------------------23 Delete Surge Event Data Setup----------------------------------- 24 Delete History Data Setup---------------------------------------- 24 Exit the Setup Page---------------------------------------------- 25 Add Channels to the Energy Monitor by Learning------------------ 25Reset the Energy Monitor to Factory Default----------------------- 26 Thank you for purchasing the GREEN POWERLINK Energy Saving Solution, an innovative product which is designed to manage home electricity usage efficiently and reduce home electricity bill.In an effort to reduce your electricity bills, why not first check out what appliance uses most energy in your home.The New GREEN POWERLINK Energy Monitor allows you to take control of home electricity usage while saving you money in the process.With GREEN POWERLINK, you can see how much electricity you are using and with greater awareness you’ll become more energy efficient. Fully educated with the critical energy information, you are naturally motivated to adopt new energy saving habits and reduce harmful carbon emission for our environment.Besides energy conservation, the GREEN POWERLINK surge protectors are also equipped with fireproof Surge MOV technology and this ensures your home appliances are well protected and free of fire hazard during catastrophic surge events. The GREEN POWERLINK is the total solution for green inspiration, energy conservation, and surge protection for your everyday life. G REEN POWERLINK Manual All Versions V1. 0 1 G REEN POWERLINK Manual All Versions V1.0 2 G REEN P O W ERLINK Manual All V e r s ions V1. 0 3 G REEN PO W ERLINK Manual All V e r s ions V1. 0 4 Smart Energy Monitor Features Top View Front View Side View Back View 1. RESET Key: restore factory default2. LEARNING Key: add new channel3. Channel indicator4. Indicates ON/OFF status of energy saver outlets5. Power failure event indicator6. Indicates audible alarm is ON7. Energy monitor low battery indicator8. Wireless signal strength indicator9. Indicates what display mode the monitor displays: INSTANT ENERGY / ENERGY / COST/ CO2 10. Data display 11. Projected and historical data display12. Clock display13. Measurement units for display modes14. Surge event counter display15. Embedded alarm speaker16. Cursor selector Key17. MODE Key: switch to different display mode18. ON&OFF Key: control energy saver outlet SET Key: confirmation button 19. AC/DC power adaptor input (Optional) 20. Battery compartment Smart Energy Monitor Specification Radio Frequency 915MHzWireless RangeLCD DimensionReplaceable BatteryDC InputOperating Temperature 915MHzUp to 100 FtYe sYe sUp to 9 ChannelsYe sYe s45mm x 55mmAA Battery X49V / 1000 mA5 ~45 at 85% relative humidity Control Energy Saveroutlets ON/OFFAudible Alarm AlertChannels controland monitoringLearning FunctionWall Mountable Functions R9P014 Series GREEN P OWERLINK Manual All V e r sions V1. 0 5 GREEN P OWERLINK Manual All V e r sions V1.0 6 Strip Type Surge Protector Features 1. Wireless Antenna - External antenna for better reception 2. AC Power Cord3. Overload Resettable Circuit Breaker - Protects against current overload at 15 Amps - Press to reset the circuit breaker 4. Surge Protection LED Indicator - The lighted green LED indicates the surge protection is working 5. Grounded Fault LED Indicator - The Red LED light only illuminates to indicate the power outlets are notproperly grounded 6. 2 “Always On” outlets - Provide continuous power for connected devices 7. Manual ON/OFF & LEARNING Key - Manual ON/OFF Mode: press the Manual ON/OFF Key to turn ON/OFFthe energy saver outlets - Learning Mode: press the LEARNING key to pair up the surge protector witht…
Text truncated - open the document above for the full version.
SCS-F19: Confidentiality Request Letter Page 1 of 2 Rev 2.0 2206 Ringwood Avenue San Jose, CA 95131 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Confidentiality Request Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (current) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 1.0 2.0 August – 11 - 2008 SCS-F19: Confidentiality Request Letter Page 2 of 2 Rev 2.0 October, 27, 2010 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Confidentiality Request regarding application for certification of FCC ID: NHS-R9P014 We hereby request confidential treatment of information accompanying this application as outlined below: - Block Diagram - Operational Description - Schematic Diagram The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, George Lee / Director Powertech Industrial Co Ltd 10F, No. 407, Chung Shan Rd., Sec 2 Chung Ho City Taipei Hsien, 235 Taiwan
Powertech Industrial Co Ltd Green Power Surge Protector FCC ID : NHS-R9P014 EUT External Photos Photo 1 General Appearance (Front View) Photo 2 General Appearance (Front & Side View) Powertech Industrial Co Ltd Green Power Surge Protector FCC ID : NHS-R9P014 Photo 3 General Appearance ( Back & Side View)
Powertech Industrial Co Ltd Green Power Surge Protector FCC ID : NHS-R9P014 ID Label Location z Label Placement Location (Back View of EUT) z ID Label Format FCC ID : NHS-R9P014 ID Label Placement Location
Powertech Industrial Co Ltd Green Power Surge Protector FCC ID : NHS-R9P014 EUT Internal Photos Photo 4 Internal View (Back Cover Removed) Photo 5 Internal View (Battery Cover Removed) Powertech Industrial Co Ltd Green Power Surge Protector FCC ID : NHS-R9P014 Photo 6 Internal View (Cover Removed) Photo 7 PCB View (PCB Removed) Powertech Industrial Co Ltd Green Power Surge Protector FCC ID : NHS-R9P014 Photo 8 PCB View (Front View) Photo 9 PCB View (Back View) Powertech Industrial Co Ltd Green Power Surge Protector FCC ID : NHS-R9P014 Photo 10 PCB View (Front View) Photo 11 PCB View (Back View) Powertech Industrial Co Ltd Green Power Surge Protector FCC ID : NHS-R9P014 Photo 12 PCB View (Front View) Photo 13 PCB View (Back View)
FCC ID: NHS-R9P014 Page 1 of 25 AUDIX Technology Corporation Report No.: EM-F990987 APPLICATION FOR CERTIFICATION On Behalf of Powertech Industrial Co Ltd Green Power Surge Protector Model No.:(1)R9P014 (2)R9P015 FCC ID:NHS-R9P014 Prepared for : Powertech Industrial Co Ltd 10F, No. 407, Chung Shan Rd., Sec 2 Chung Ho City, Taipei Hsien, 235 Taiwan Prepared by : AUDIX Technology Corporation EMC Department No. 53-11, Tin-Fu Tsun, Lin-Kou Hsiang, Taipei Hsien, Taiwan Tel : (02) 2609-9301, 2609-2133 Fax: (02) 2609-9303 File Number : C1M1009160 Report Number : EM-F990987 Date of Test : Sep. 29 ~ Oct. 29, 2010 Date of Report : Oct. 29, 2010 FCC ID: NHS-R9P014 Page 2 of 25 AUDIX Technology Corporation Report No.: EM-F990987 TABLE OF CONTENTS Description Page TEST REPORT CERTIFICATION .......................................................................................................3 1. GENERAL INFORMATION .........................................................................................................4 1.1. Description of Device (EUT).................................................................................................................. 4 1.2. Description of Test Facility .................................................................................................................... 4 1.3. Measurement Uncertainty....................................................................................................................... 5 2. POWERLINE CONDUCTED EMISSION MEASUREMENT ..................................................6 3. RADIATED EMISSION MEASUREMENT ................................................................................7 3.1. Test Equipment ....................................................................................................................................... 7 3.2. Test Setup ............................................................................................................................................... 7 3.3. Radiated Emission Limits (§15.209) ...................................................................................................... 8 3.4. Fundamental Frequency Limits (§15.249).............................................................................................. 8 3.5. Operating Condition of EUT .................................................................................................................. 9 3.6. Test Procedure ........................................................................................................................................ 9 3.7. Radiated Emission Measurement Test Results .....................................................................................10 4. DEVIATION TO TEST SPECIFICATIONS..............................................................................22 5. PHOTOGRAPHS...........................................................................................................................23 5.1. Photos of Radiated Emission Measurement at Semi-Anechoic Chamber ............................................ 23 FCC ID: NHS-R9P014 Page 3 of 25 AUDIX Technology Corporation Report No.: EM-F990987 TEST REPORT CERTIFICATION Applicant : Powertech Industrial Co Ltd EUT Description : Green Power Surge Protector FCC ID : NHS-R9P014 (A) MODEL NO. : (1)R9P014 (2)R9P015 (B) SERIAL NO. : N/A (C) POWER SUPPLY : DC 6V (D) TEST VOLTAGE : DC 6V Measurement Procedure Used: FCC RULES AND REGULATIONS PART 15 SUBPART C, October 2009 AND ANSI C63.4/2003 (FCC CFR 47 Part 15C, §15.207, §15.249, §15.209) The device described above was tested by AUDIX Technology Corporation to determine the maximum emission levels emanating from the device. The maximum emission levels were compared to the FCC Part 15 subpart C limits. The measurement results are contained in this test report and AUDIX Technology Corporation is assumed full responsibility for the accuracy and completeness of these measurements. Also, this report shows that the EUT to be technically compliant with the FCC official limits. This report applies to above tested sample only. This report shall not be reproduced in part without written approval of AUDIX Technology Corporation. Date of Test : Sep. 29 ~ Oct. 29, 2010 Date of Report : Oct. 29, 2010 Producer : (Julie Hsu/Administrator) Reviewer : (Henning Chang/Supervisor) Signatory: (Ben Cheng/Manager) FCC ID: NHS-R9P014 Page 4 of 25 AUDIX Technology Corporation Report No.: EM-F990987 1. GENERAL INFORMATION 1.1. Description of Device (EUT) Description : Green Power Surge Protector (Transceiver) Model Number : (1)R9P014 (With Relay) (2)R9P015 (Without Relay) The M/N R9P014 is representative selected to test in this report FCC ID : NHS-R9P014 Applicant : Powertech Industrial Co Ltd 10F, No. 407, Chung Shan Rd., Sec 2 Chung Ho City, Taipei Hsien, 235 Taiwan Fundamental Frequency : 915MHz AC Rating : DC 6V Date of Receipt of Sample : Sep. 15, 2010 Date of Test : Sep. 29 ~ Oct. 29, 2010 1.2. Description of Test Facility Name of Firm : AUDIX Technology Corporation EMC Department No. 53-11, Tin-Fu Tsun, Lin-Kou Hsiang, Taipei Hsien, Taiwan. Test Facility & Location : No. 2 Shielded Room & (C2/AC) Semi-Anechoic Chamber No. 53-11, Tin-Fu Tsun, Lin-Kou Hsiang, Taipei Hsien, Taiwan. Renewal on May 14, 2009 Federal Communication Commission Registration Number: 90993 NVLAP Lab. Code : 200077-0 TAF Accreditation No : 1724 FCC ID: NHS-R9P014 Page 5 of 25 AUDIX Technology Corporation Report No.: EM-F990987 1.3. Measurement Uncertainty Test Item Frequency Range Uncertainty (dB) 30MHz~300MHz ±2.91dB 300MHz~1000MHz ±2.94dB Radiation Test (Distance: 3m) Above 1GHz ± 5.02dB Remark : Uncertainty = ku c (y) FCC ID: NHS-R9P014 Page 6 of 25 AUDIX Technology Corporation Report No.: EM-F990987 2. POWERLINE CONDUCTED EMISSION MEASUREMENT 【The EUT only employ battery power for operation, no conductive emissions limits are required according to FCC Part 15 Section §15.207】 FCC ID: NHS-R9P014 Page…
Text truncated - open the document above for the full version.
FCC ID: NHS-R9P014 Page 23 of 25 AUDIX Technology Corporation Report No.: EM-F990987 5. PHOTOGRAPHS 5.1. Photos of Radiated Emission Measurement at Semi-Anechoic Chamber 5.1.1. Frequency Range 30MHz~1GHz Position: Stand Position: Side FCC ID: NHS-R9P014 Page 24 of 25 AUDIX Technology Corporation Report No.: EM-F990987 Position: Lie 5.1.2. Frequency Above 1GHz Position: Stand FCC ID: NHS-R9P014 Page 25 of 25 AUDIX Technology Corporation Report No.: EM-F990987 Position: Side Position: Lie
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 915 MHz - 915 MHz | - |

Zigbee Module
Equipment Class
DTS - Digital Transmission System
Mobile Accessory - Breathalyzer
Equipment Class
DTS - Digital Transmission System
APPS Power Control Timer Strip
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
ZigBee Tracking Energy Monitor
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
ZigBee Tracking Smart Socket
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter