Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Outdoor Motion-Sensing User’s Manual Introduction Using Your Outdoor Motion-Sensing is a convenient way to detect some body is walking across. The Outdoor Motion-Sensing Light adapter will turns lights on when motion is detected, and the transmitter will active and send on signal only 1.5 sec. The light will stay on for 1 or 10 minutes after all motion has stopped and the transmitter will active and send off signal only 1.5 sec. Motion Sensor Installation Screw the Socket Adapter into the empty light socket and then screw light bulb into Socket Adapter. Battery Installation 1. Remove battery cover from the bottom of the sensor housing by pushing open the sliding battery door. 2. Install one 9-Vlot alkaline battery into the battery compartment. Be sure the battery(+)and(-)terminals match (+)and(-) contacts on battery cap. 3. Replace battery cover. NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.
LABEL Format: This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation Model No. : R1G0072R1A FCC ID : NHSPT-462 LABEL Size: 36 x 10 mm LABEL Position:
Circuit Block Description (Ref. To “RF CIRCUIT BLOCK”) Model: R1G0072R1A00000 (Pir-sensor transmitter) FCC ID: NHSPT-462 (Transmitter Block) 1. Battery: DC/9V. Transmitter is using battery operation system. 2. The Transmitter has a pyroelectric passive infraed sensor component. 3. When sensor is active, it can trig 4538 IC (U3), Let the transmitter working. 4. When the Transmitter active, then the Timer (using RC circuit C3,R8) setting only 1.5 second time on. 5. The (BK-2) is RF code encoder IC (PT-2262S). 6. The (BK-3) is 315Mhz RF transmitter circuit, It’s belong AM/FM modulation 100% by Manchester coding 33/66-duty cycle. 7. The Transmitter antenna is a PCB loop direction antenna for low power transmits.
Test Report ----------------------------------------------------------------------------- 1/17 Report No.: G2115329 (Tx) Training Research Co., Ltd., TEL: 886-2-26935155,Fax: 886-2-26934440 Report No. G2115329 Specifications FCC Part 15.231, Certification Test Method ANSI C63.4 1992 Applicant POWERTECH INDUSTRIAL CO., LTD. Applicant 10F, No. 403, Chung Shan Rd., Sec. 2, Chung Ho City, address Taipei Hsien, Taiwan 235 , R.O.C. Items tested RF Transmitter Model No. R1G0072R1A (Sample # G21329) Results Compliance (As detailed within this report) Date 05/08/2002 (month / day / year) (Sample received) 06/10/2002 (month / day / year) (Test) Prepared by Project Engineer Authorized by General Manager (Frank Tsai) Issue date June 12, 2002 (month / day / year) Modifications None Tested by Training Research Co., Ltd. Office at 2, Lane 194, Huan-Ho Street, Hsichih, Taipei Hsien 221, Taiwan Chamber at 2, Lane 194, Huan-Ho Street, Hsichih, Taipei Hsien 221, Taiwan Conditions of issue: (1) This test report shall not be reproduced except in full, without written approval of TRC. And the test result contained within this report only relate to the sample submitted for testing. (2) This report must not be used by the client to claim product endorsement by NVLAP or any agency of U.S. Government. ★ NVLAP LAB CODE: 200174-0 ★ FCC ID: NHSPT-462 Test Report ----------------------------------------------------------------------------- 2/17 Report No.: G2115329 (Tx) Training Research Co., Ltd., TEL: 886-2-26935155,Fax: 886-2-26934440 Table of Contents CHAPTER 1 GENERAL................................................................................. 3 1.1 I NTRODUCTION .................................................................... 3 1.2 D ESCRIPTION OF EUT .......................................................... 3 1.3 D ESCRIPTION OF S UPPORT E QUIPMENT ................................ 3 1.4 T EST P ROCEDURE ................................................................ 4 1.5 L OCATION OF THE T EST S ITE ............................................... 4 1.6 G ENERAL T EST C ONDITION ................................................. 4 CHAPTER 2 TRANSMITTER DUTY CYCLE MEASUREMENTS ........ 5 2.1 T EST C ONDITION AND S ETUP ............................................... 5 2.2 L IST OF T EST I NSTRUMENTS ................................................ 5 2.3 T EST I NSTRUMENTS C ONFIGURATION .................................. 6 2.4 T EST R ESULT ....................................................................... 6 CHAPTER 3 TRANSMITTER BANDWIDTH MEASUREMENTS, FCC PART 15.231(C) ............................................................. 9 3.1 T EST C ONDITION & S ETUP ................................................... 9 3.2 T EST R ESULT ....................................................................... 9 CHAPTER 4 CONDUCTED EMISSIONS MEASUREMENTS .............. 11 4.1 T EST C ONDITION ................................................................ 11 4.2 T EST R ESULT ..................................................................... 11 CHAPTER 5 RADIATED EMISSIONS MEASUREMENTS .................. 12 5.1 G ENERAL C ONFIGURATION ................................................ 12 5.2 T EST C ONDITION AND S ETUP ............................................. 12 5.3 L IST OF T EST I NSTRUMENTS .............................................. 14 5.4 T EST I NSTRUMENTS C ONFIGURATION ................................ 15 5.5 T EST R ESULT OF R ADIATED E MISSIONS ............................. 16 Table 1 Open Field Radiated Emissions for 30MHz to 1GHz [Horizontal, X-axis] ............ 16 Table 2 Open Field Radiated Emissions for 30MHz to 1GHz [Vertical, X-axis] ................ 16 Table 3 Open Field Radiated Emissions for 1GHz to 4GHz [Horizontal, X-axis] ............... 17 Table 4 Open Field Radiated Emissions For 1GHz to 4GHz [Vertical, X-axis] .................. 17 Test Report ----------------------------------------------------------------------------- 3/17 Report No.: G2115329 (Tx) Training Research Co., Ltd., TEL: 886-2-26935155,Fax: 886-2-26934440 Chapter 1 GENERAL 1.1 Introduction The following measurement report is submitted on behalf of applicant in support of an International Periodic Radiator certification with Part 2 Subpart J and Part 15 Subpart A and C of the Commission's Rules and Regulations. 1.2 Description of EUT EUT : RF Transmitter Model No. : R1G0072R1A FCC ID : NHSPT-462 Frequency Range : Operated in 315.075MHz Power Type : Powered by 9V battery Applicant : Powertech Industrial Co., Ltd. 10F, No. 403, Chung Shan Rd., Sec. 2, Chung Ho City, Taipei Hsien, Taiwan 235, R.O.C. The fundamental frequency of transmitter emitted is due to a press on button of the EUT. The emitting time of fundamental frequency is less than 5 seconds pursuant to FCC Part 15.231(a). There are security codes for avoiding the possibility of duplicating codes in adjacent systems. The coding must be matching with the companion receiver. While testing the EUT was adjusted at a position which transmit the maximum emission. 1.3 Description of Support Equipment Bulb : 200 Watt Test Report ----------------------------------------------------------------------------- 4/17 Report No.: G2115329 (Tx) Training Research Co., Ltd., TEL: 886-2-26935155,Fax: 886-2-26934440 1.4 Test Procedure All measurements contained in this report were performed according to the techniques described in measurement procedure of ANSI C63.4 1992 section 13 1.5 Location of the Test Site The radiated emissions measurements required by the rules were performed on the three-meter, Anechoic Chamber (Registration Number: 93906) maintained by Training Research Co., Ltd. 1F, No. 2, Lane 194, Huan-Ho Street, Hsi-chih, Taipei Hsien 221, Taiwan, R.O.C. Complete description and measurement data have been placed on file with the commission. The conducted power line emissions tests and other test items were performed in a anechoic chamber also located at Tr…
Text truncated - open the document above for the full version.
Test Report ----------------------------------------------------------------------------- 1/2 FCC ID: NHSPT-462, Test Data: 2002/6/19 Training Research Co., Ltd., TEL: 886-2-26935155,Fax: 886-2-26934440 CONDUCTED EMISSIONS MEASUREMENTS Test condition and setup All the equipment is placed and setup according to the ANSI C63.4 –1992. The EUT is assembled on a wooden table, which is 80 cm high, is placed 40 cm from the back-wall, which is a vertical conducting plane. One LISN is for EUT, the other LISN is for support equipment. They are all placed on the conductive ground. The EUT’s LISN connect a line switch box for selecting L1 or L2, then connect to a preamplifier and spectrum. The spectrum scans from 450KHz to 30MHz. Conducted emission levels are detected at maximum peak mode. But if the maximum peak mode failed, it will be measured by CISPR‘s quasi-peak detection mode. While testing, there is the worst-emission plot printed at peak detection mode, and there are more than 6 highest emissions relative to limit recorded. The plot is kept as the original data, not included in test report. List of test Instrument Calibration Date Instrument Name Model No. Brand Serial No. Last time Next time EMI Receiver 8546A H P 3520A00242 06/29/01 06/29/02 RF Filter Section 85460A H P 3448A00217 06/29/01 06/29/02 LISN (EUT) LISN-01 TRC 9912-03,04 12/09/01 12/09/02 LISN (Support E.) LISN-01 TRC 9912-05 01/04/02 01/04/03 Switch/Control Unit 3488A HP N/A 11/20/01 11/20/02 (< 30MHz) Auto Switch Box ASB-01 TRC 9904-01 11/20/01 11/20/02 (< 30MHz) The level of confidence of 95%, the uncertainty of measurement of conducted emission is ± 2.4 dB. Test Report ----------------------------------------------------------------------------- 2/2 FCC ID: NHSPT-462, Test Data: 2002/6/19 Training Research Co., Ltd., TEL: 886-2-26935155,Fax: 886-2-26934440 Conducted Emission Test Result Testing room : Temperature : 24 ° C Humidity : 57 % RH Line 1 READING AMPLITUDE LIMIT Frequency (kHz) Peak (dB μ V) Quasi-Peak (dB μ V) Average (dB μ V) Quasi-Peak (dB μ V) Average (dB μ V) Margin (dB) 549.00 33.57 --- --- 48.00 --- -14.43 620.00 31.93 --- --- 48.00 --- -16.07 705.00 35.12 --- --- 48.00 --- -12.88 729.00 30.07 --- --- 48.00 --- -17.93 798.00 34.05 --- --- 48.00 --- -13.95 813.00 34.33 --- --- 48.00 --- -13.67 904.00 31.31 --- --- 48.00 --- -16.69 1021.00 29.82 --- --- 48.00 --- -18.18 1192.00 29.80 --- --- 48.00 --- -18.20 1792.00 31.00 --- --- 48.00 --- -17.00 Line 2 READING AMPLITUDE LIMIT Frequency (kHz) Peak (dB μ V) Quasi-Peak (dB μ V) Average (dB μ V) Quasi-Peak (dB μ V) Average (dB μ V) Margin (dB) 534.00 37.14 --- --- 48.00 --- -10.86 568.00 44.99 --- --- 48.00 --- -3.01 586.00 38.28 --- --- 48.00 --- -9.72 910.00 37.29 --- --- 48.00 --- -10.71 1015.00 36.77 --- --- 48.00 --- -11.23 1232.00 34.44 --- --- 48.00 --- -13.56 1382.00 39.07 --- --- 48.00 --- -8.93 1758.00 38.76 --- --- 48.00 --- -9.24 2000.00 35.59 --- --- 48.00 --- -12.41 2870.00 37.13 --- --- 48.00 --- -10.87 *The reading amplitudes are all under limit.
Test Setup Photos ------------------------------------------------------------------------- 1/1 FCC ID: NHSPT-462 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Radiated Test Setup Placement: (Photographs, X-axis)
Test Setup Photos ------------------------------------------------------------------------- 1/1 FCC ID: NHSPT-462 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Conducted Test Setup Placement: (Photographs)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 314.5 MHz - 315.5 MHz | - |

Zigbee Module
Equipment Class
DTS - Digital Transmission System
Mobile Accessory - Breathalyzer
Equipment Class
DTS - Digital Transmission System
APPS Power Control Timer Strip
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
ZigBee Tracking Energy Monitor
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
ZigBee Tracking Smart Socket
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter