FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Siemens Canada Ltd. - Siemens Milltronics Process Instruments/
  3. NJA-LR400-1

NJA-LR400-1RADAR LAVEL GAUGE

Siemens Canada Ltd. - Siemens Milltronics Process Instruments
RADAR LAVEL GAUGE - FCC ID NJA-LR400-1 - Siemens Canada Ltd. - Siemens Milltronics Process Instruments
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Dec 07, 2004
Application Purpose
Original Equipment
Date of Application
Dec 07, 2004
Equipment Note
RADAR LAVEL GAUGE
Frequency Range
24200.00000000 - 25200.00000000
Company
Siemens Canada Ltd. - Siemens Milltronics Process Instruments
Country
Canada

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Instruction Manual October 2004 LR400 sitrans © Siemens Milltronics Process Instruments Inc. 2004 Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by a clarification of the level of caution to be observed. Qualified Personnel: This device/system may only be set up and operated in conjunction with this manual. Qualified personnel are only authorized to install and operate this equipment in accordance with established safety practices and standards. Unit Repair and Excluded Liability: • The user is responsible for all changes and repairs made to the device by the user or the user’s agent. • All new components are to be provided by Siemens Milltronics Process Instruments Inc. • Restrict repair to faulty components only. • Do not reuse faulty components. Warning: This product can only function properly and safely if it is correctly transported, stored, installed, set up, operated, and maintained. Note: Always use product in accordance with specifications. Copyright Siemens Milltronics Process Instruments Inc. 2004. All Rights Reserved Disclaimer of Liability This document is available in bound version and in electronic version. We encourage users to purchase authorized bound manuals, or to view electronic versions as designed and authored by Siemens Milltronics Process Instruments Inc. Siemens Milltronics Process Instruments Inc. will not be responsible for the contents of partial or whole reproductions of either bound or electronic versions. While we have verified the contents of this manual for agreement with the instrumentation described, variations remain possible. Thus we cannot guarantee full agreement. The contents of this manual are regularly reviewed and corrections are included in subsequent editions. We welcome all suggestions for improvement. Technical data subject to change. MILLTRONICS®is a registered trademark of Siemens Milltronics Process Instruments Inc. Contact SMPI Technical Publications at the following address: Technical Publications Siemens Milltronics Process Instruments Inc. 1954 Technology Drive, P.O. Box 4225 Peterborough, Ontario, Canada, K9J 7B1 Email: [email protected] • For a selection of Siemens Milltronics level measurement manuals, go to: www. siemens.com/processautomation. Under Process Instrumentation, select Level Measurement and then go to the manual archive listed under the product family. • For a selection of Siemens Milltronics weighing manuals, go to: www. siemens.com/processautomation. Under Weighing Technology, select Continuous Weighing Systems and then go to the manual archive listed under the product family. i Ta b l e o f C o n t e n t s General Information ...........................................................................................................1 Safety Notes .............................................................................................................................................1 The Manual ...............................................................................................................................................1 Abbreviations and Identifications .......................................................................................................2 SITRANS LR 400 ......................................................................................................................................3 Structure ....................................................................................................................................................3 System Implementation .........................................................................................................................5 Specifications ...................................................................................................................... 6 SITRANS LR 400 ............................................................................................................................6 Dimensions ............................................................................................................................................. 11 Purging System .................................................................................................................17 Installation ......................................................................................................................... 18 Mounting Location ................................................................................................................................18 Beam Spreading ..........................................................................................................................19 Correct Installation in Mounting Nozzle ................................................................................19 Installation using Easy Aimer LR .............................................................................................19 Electrical Connection ...........................................................................................................................20 Start Up ............................................................................................................................... 22 Self-test ....................................................................................................................................................22 Multi-display ...........................................................................................................................................22 Local Programming ...............................................................................................................................22 Auto-Setup ..............................................................................................................................................22 Operation ................…

Text truncated - open the document above for the full version.

Cover Letter(s)

1954 Technology Drive, P.O. Box 4225, Peterborough, ON Canada K9J 7B1 Tel: (705) 745-2431 Fax: (705) 741-0466 www.siemens-milltronics.com «Report_Date» FEDERAL COMMUNICATIONS COMMISSION 7435 Oakland Mills Road Columbia, MD 21046 U.S.A. Subject: Request for withholding from public disclosure the schematic diagrams and system block diagrams pursuant to an application for certification. Applicant: Siemens Milltronics Process Inst. Inc. Product: Sitrans LR 400 Model: 7ML5420 & 7ML5421 FCC ID: NJA-LR400-1 Dear Sir/Madam, We, Siemens Milltronics Process Inst. Inc., would like to request that the schematic diagrams, system block diagrams, parts list and Operational description submitted with the application for certification be withheld from public disclosure as per Section 0.459 of FCC Rules. This request is made under the provisions of Section 0.457(d) of the Commission's Rules, and Section 552(b)(4) of the Freedom of Information Act. These sections authorize as a withholding from public inspection materials which would be privileged as a matter of law if retained by the person submitting them, and materials which would not customarily be released to the public by that person. If you have any queries, please do not hesitate to contact us by our TOLL FREE numbers: OUR TELEPHONE NO.: 1-705-740-7009 Yours truly, BALJINDER SINGH ...................................................................... Mechanical Designer, R&D Siemens Milltronics Process Instruments Inc. 1954, Technology Drive, P.O. Box 4225 Peterborough, ON, Canada K9J 7B1 PH: +1 705 740-7030 FAX: +1 705 745-2930 Email: [email protected] ......................................................................

External Photos

ANNEX 3 - EXTERNAL PHOTOS OF THE EUTPHOTO # 1 SIEMENS MILLTRONICS SITRANS LR ANNEX 3 - EXTERNAL PHOTOS OF THE EUTPHOTO # 2 SIEMENS MILLTRONICS SITRANS LR

ID Label/Location Info

Product Group FOR INTERNAL USE ONLY 2425147101 B. SINGH PETERBOROUGH 20 / SEPT / 2004 RADAR FOR CONSTRUCTION 0 1 T. LITTLE R. CLYSDALE 1 : 1 1 1 NTS B SITRANS LR 400 EASY AIMER VERSION NAMEPLATE DRAWING 24251471 1 RPC RPC BPS BPS SEPT 20/04 BOX NUMBER APPROVAL AGENCY APPROVAL LOGO SIZE BOX 15 BOX 4 BOX 5 BOX 9 BOX 11 CE ATEX FM CSA CETECOM CETECOM CSA NON-HAZ CE RADIO 5 mm 7 mm 7 mm 7 mm 7 mm 7 mm 5 mm RRR ICT G750879M FCC ID NJA-LR400-1 FCC ID NJA-LR400-1 NOTES: 1. NAMEPLATE INFORMATION TO BE LASER ETCHED ON STAINLESS STEEL BLANK 24251135. 2. FONT SIEMENS SANS, 2.4mm HIGH UNLESS OTHERWISE NOTED. 3. BOX 12 - UNIT SERIAL NUMBER, FONT SIEMENS SANS 2.4 mm HIGH. 4. BOX 8 - CETECOM APPROVAL AGENCY ID NUMBER 5. BOX 6 - HAZARDOUS APPROVAL 6. BOX 3 - FCC STATEMENTS (FONT SIEMENS SANS, 1.9mm HIGH) 7. BOX 7 - INDUSTRY CANADA – ® Canada 267104596A 8. BOX 10 CE ATEX APPROVAL AGENCY I.D. 0518 FONT SIEMENS SANS, 1.5 mm HIGH. 9. BOX 16 (CE) CETECOM APPROVAL AGENCY I.D. 0682 FONT SIEMENS SANS, 1.5 mm HIGH. 10. BOX 16 CE RADIO (TRL) APPROVAL AGENCY I.D. 0891 FONT SIEMENS SANS,1.5 mm HIGH. 11. PRODUCT CONFIGURATION NUMBER SHOWN FOR EXAMPLE ONLY. RRR Siemens Milltronics Process Instruments Inc., Peterborough Made in Canada SITRANS LR 400 Radar Level Meter Serial # Amb. Temp.: Enclosure: Output: 13 17 21.5 34 38 42 51 30 25.5 59.5 6 84 87.5 55 18 67 75 21 27 58 BOX 6 BOX 5 BOX 8 BOX 9 BOX 11 BOX 15 BOX 16 BOX 10 BOX 1 BOX 14 BOX 2 BOX 12 BOX 17 BOX 7 BOX 4 BOX 3 Power Rating: 120 - 230 V , ±15%, 50/60 Hz, 6 W – 40°C to 65°C TYPE/NEMA 4X, 6 / IP67 BOX 14 7ML5420 7ML5420-0AB00-1BC-2 BOX 2 A B C D E II 1/2 D T6 Box 1 Box 17 0 1 4 - 20 mA HART PROFIBUS PA APPROVALS LOGOS CE, CE RADIO, CSA-NON HAZ., INDUSTRY CAN, FCC CE, CETECOM CE, CETECOM, ATEX II 1/2 D T6 CE, CE RADIO, ATEX CSA, FM, HAZARDOUS, FCC, INDUSTRY CAN B C E F 120 - 230 V , ±15%, 50/60 Hz, 6 W 24 V +25 / -20%, 6 W 24 V +25 / -20%, 6 W – 40°C to 65°C – 40°C to 65°C – 20°C to 65°C – 20°C to 65°C CLASS II, DIV 1, GR. E,F, G CLASS III This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference,and (2) This device must accept any interference received, including interference that may cause undesired operation CHANGE FCC ID NUMBER, CHANGE ATEX TEMP RANGE TO -20°C PRE ECN 2004-0249 OCT 29/2004

Internal Photos

ANNEX 4 - INTERNAL PHOTOS OF THE EUTPHOTO # 1 SIEMENS MILLTRONICS SITRANS LR ANNEX 4 - INTERNAL PHOTOS OF THE EUTPHOTO # 2 SIEMENS MILLTRONICS SITRANS LR ANNEX 4 - INTERNAL PHOTOS OF THE EUTPHOTO # 3 SIEMENS MILLTRONICS SITRANS LR ANNEX 4 - INTERNAL PHOTOS OF THE EUTPHOTO # 4 SIEMENS MILLTRONICS SITRANS LR ANNEX 4 - INTERNAL PHOTOS OF THE EUTPHOTO # 5 SIEMENS MILLTRONICS SITRANS LR ANNEX 4 - INTERNAL PHOTOS OF THE EUTPHOTO # 6 SIEMENS MILLTRONICS SITRANS LR ANNEX 4 - INTERNAL PHOTOS OF THE EUTPHOTO # 7 SIEMENS MILLTRONICS SITRANS LR ANNEX 4 - INTERNAL PHOTOS OF THE EUTPHOTO # 8 SIEMENS MILLTRONICS SITRANS LR ANNEX 4 - INTERNAL PHOTOS OF THE EUTPHOTO # 9 SIEMENS MILLTRONICS SITRANS LR ANNEX 4 - INTERNAL PHOTOS OF THE EUTPHOTO # 10 SIEMENS MILLTRONICS SITRANS LR ANNEX 4 - INTERNAL PHOTOS OF THE EUTPHOTO # 11 SIEMENS MILLTRONICS SITRANS LR

Test Report

Sept. 08, 2004 SIEMENS MILLTRONICS PROCESS INSTRUMENTS INC. P.O. Box 4225, 1954 Technology Drive Peterborough, Ontario Canada, K9J 7B1 Attn.: Mr. Enzo De Simone Subject: FCC Certification Authorization Application under FCC PART 15, Subpart C, Sec. 15.209 – Low Power Licence-Exempt RadioCommunication Devices totally enclosed in Metal and Concrete Containers and swept in the frequency band 24.2 - 25.2 GHz. Product: SITRANS LR 400 (25 GHZ RADAR LEVEL GAUGE) Model No.: 7ML5420 & 7ML5421 FCC ID: NJA-LR400-1 Dear Mr. De Simone, The product sample, as provided by you, has been tested and found to comply with FCC PART 15, Subpart C, Sec. 15.209 - Low Power Transmitters operating in the frequency band 24.2 - 25.2 GHz. Enclosed you will find copies of the engineering report. If you have any queries, please do not hesitate to contact us. Yours truly, Tri Minh Luu, P. Eng., V.P., Engineering Encl UltraTech Group of Labs 31040/SIT C-1376 46390-2049 200093-0 2 00-034 SL2-IN-E-1119R 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 Tel.: (905) 829-1570 Fax.: (905) 829-8050 Website: www.ultratech-labs.com Email: [email protected] SITRANS LR 400 (25 GHZ RADAR LEVEL GAUGE) (for use with Metal and Concrete Tanks/Vessels without ventilation) Model No.: 7ML5420 & 7ML5421 FCC ID: NJA-LR400-1 Applicant: SIEMENS MILLTRONICS PROCESS INSTRUMENTS INC. P.O. Box 4225, 1954 Technology Drive Peterborough, Ontario Canada, K9J 7B1 In Accordance With FEDERAL COMMUNICATIONS COMMISSION (FCC) PART 15, SUBPART C, SEC. 15.209 Low Power Licence-Exempt RadioCommunication Devices totally enclosed in Metal and Concrete Containers and swept in the frequency band 24.2 - 25.2 GHz. UltraTech's File No.: MIL-322F15C This Test report is Issued under the Authority of Tri M. Luu, Professional Engineer, Vice President of Engineering UltraTech Group of Labs Date: Sept. 08, 2004 Report Prepared by: Tri Luu, P.Eng. Tested by: Tri Luu & Hung Trinh Issued Date: Sept. 08, 2004 Test Dates: Aug. 05 & 24, 2004 ƒ The results in this Test Report apply only to the sample(s) tested, and the sample tested is randomly selected. ƒ This report must not be used by the client to claim product endorsement by NVLAP or any agency of the US Government. UltraTech 3000 Bristol Circle, Oakville, Ontario, Canada, L6H 6G4 Tel.: (905) 829-1570 Fax.: (905) 829-8050 Website: www.ultratech-labs.com Email: [email protected], Email: [email protected] 2 31040/SIT C-1376 46390-2049 200093-0 SL2-IN-E-1119R 00-034 FCC PART 15, SUBPART C, SEC. 15.209 - LOW POWER TRANSMITTERS Page 2 SITRANS LR 400 (25 GHZ RADAR LEVEL GAUGE), Model 7ML5420 & 7ML5421 FCC ID: NJA-LR400-1 ULTRATECH GROUP OF LABS File #: MIL-322F15C 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 Sept. 08, 2004 Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: [email protected] , Website: http://www.ultratech-labs.com • All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST) TABLE OF CONTENTS EXHIBIT 1. INTRODUCTION ................................................................................................................................ 4 1.1. SCOPE................................................................................................................................................................ 4 1.2. RELATED SUBMITAL(S)/GRANT(S) ........................................................................................................................ 4 1.3. NORMATIVE REFERENCES .......................................................................................................................... 4 1.4. DIFFEENCE BETWEEN MODEL 7ML5420 & 7ML5421............................................................................................ 5 EXHIBIT 1. PERFORMANCE ASSESSMENT...................................................................................................... 8 1.1. CLIENT INFORMATION .................................................................................................................................... 8 1.2. EQUIPMENT UNDER TEST (EUT) INFORMATION............................................................................................. 8 1.3. EUT’S TECHNICAL SPECIFICATIONS ......................................................................................................... 9 1.4. LIST OF EUT’S PORTS....................................................................................................................................... 10 1.5. ANCILLARY EQUIPMENT.................................................................................................................................... 10 EXHIBIT 2. EUT OPERATING CONDITIONS AND CONFIGURATIONS DURING TESTS ..................... 11 2.1. CLIMATE TEST CONDITIONS...............................................................................................................................11 2.2. OPERATIONAL TEST CONDITIONS & ARRANGEMENT FOR TESTS......................................................................... 11 2.3. GENERAL TEST SETUP................................................................................................................................ 11 2.3.1. Test Configuration #1: Metal Tank with no ventilation............................................................................ 11 2.3.2. Test Configuration #2: Concrete Tank with ventilation ...........................................................................11 EXHIBIT 3. SUMMARY OF TEST RESULTS .................................................................................................... 12 3.1. LOCATION OF TESTS ................................................................................................................................... 12 3.2. APPLICABILITY & SUMMARY OF EMC EMISSION TEST RESULTS................................................................ 12 EXHIBIT 4. MEASUREMENTS, EXAMINATIONS & TEST DATA F…

Text truncated - open the document above for the full version.

Test Report

FCC PART 15, SUBPART C, SEC. 15.209 - LOW POWER TRANSMITTERS Page 15 SITRANS LR 400 (25 GHZ RADAR LEVEL GAUGE), Model 7ML5420 FCC ID: NJA-LR400-1 ULTRATECH GROUP OF LABS File #: MIL-322F15C 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 Sept. 08, 2004 Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: [email protected] , Website: http://www.ultratech-labs.com • All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST) 4.5.5. Test Data 4.5.5.1. Test Configuration #1: AC Power Supply Option (120V, 60 Hz) Please refer to the following Plots #1 and 2 for detailed measurements. Plot # 1: AC POWER LINE CONDUCTED EMISSIONS MEASUREMENT Detector: [X] PEAK [X] QUASI-PEAK [X] AVERAGE Temp: 22C° Humidity: 53% Line Tested: Line 1 Line Voltage 120V AC Test Tech: Hung Test Date: Dec. 02, 04 Standard: FCC Class B Comments: Si g n a l Fr e q ( MHz ) PK Amp QP Amp AV Amp QPL1 1 0/ . 194625 48. 3 43. 2 37. 5 - 20/.7 2 2. 25350/0/ 44.4 41.7 34.8 -14.4 3 9.0/4650/0/ 38.2 35.6 26.0/ -24.4 IF BW 9. 0/ kHz AVG BW 30/ kHz SWP 1. 40/ sec ATN 10/ dB REF 8 0/.0/ dB VLOG 10/ dB/ START 1 5 0/ kHzSTOP 30/.0/0/ MHz 33.40/ dB V MK R 9 . 0/5 MHz ACTV DET: PEAK VA SB SC FC CORRA MEAS DET: PEAK QP AVG FCC PART 15, SUBPART C, SEC. 15.209 - LOW POWER TRANSMITTERS Page 16 SITRANS LR 400 (25 GHZ RADAR LEVEL GAUGE), Model 7ML5420 FCC ID: NJA-LR400-1 ULTRATECH GROUP OF LABS File #: MIL-322F15C 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 Sept. 08, 2004 Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: [email protected] , Website: http://www.ultratech-labs.com • All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST) Plot # 2: AC POWER LINE CONDUCTED EMISSIONS MEASUREMENT Detector: [X] PEAK [X] QUASI-PEAK [X] AVERAGE Temp: 22C° Humidity: 53% Line Tested: Line 2 Line Voltage 120V AC Test Tech: Hung Test Date: Dec. 02, 04 Standard: FCC Class B Comments: Si g n a l Fr e q ( MHz ) PK Amp QP Amp AV Amp QPL1 1 0/ . 194625 48. 3 43. 2 37. 5 - 20/.7 2 2. 25350/0/ 44.4 41.7 34.8 -14.4 3 9.0/4650/0/ 38.2 35.6 26.0/ -24.4 IF BW 9. 0/ kHz AVG BW 30/ kHz SWP 1. 40/ sec ATN 10/ dB REF 8 0/.0/ dB VLOG 10/ dB/ START 1 5 0/ kHzSTOP 30/.0/0/ MHz 33.40/ dB V MK R 9 . 0/5 MHz ACTV DET: PEAK VA SB SC FC CORRA MEAS DET: PEAK QP AVG

Test Setup Photos

ANNEX 1 - PHOTOGRAPHS OF RADIATED EMISSIONS MEASUR EMENTS PHOTO # 1 Siemens Milltronics SITRANS LR, Model No: 7ML5420 & 7ML5421 FCC ID: NJA-LR400-1 AC/DC Power Line Conducted Emissions Test Setup ANNEX 1 - PHOTOGRAPHS OF RADIATED EMISSIONS MEASUR EMENTS PHOTO # 2 Siemens Milltronics SITRANS LR, Model No: 7ML5420 & 7ML5421 FCC ID: NJA-LR400-1 AC/DC Power Line Conducted Emissions Test Setup ANNEX 1 - PHOTOGRAPHS OF RADIATED EMISSIONS MEASUR EMENTS PHOTO # 3 Siemens Milltronics SITRANS LR, Model No: 7ML5420 & 7ML5421 FCC ID: NJA-LR400-1 Carrier and spurious/harmonic emissions from the Siemens M illtronics SITRANS LR, which was mounted on top of the metal tank without ventilation, were scanned using a horn antenna at 0.2, 0.5, 1.0 and 3 meters distances. ANNEX 1 - PHOTOGRAPHS OF RADIATED EMISSIONS MEASUR EMENTS PHOTO # 4 Siemens Milltronics SITRANS LR, Model No: 7ML5420 & 7ML5421 FCC ID: NJA-LR400-1 Concrete cement tank contains cement ANNEX 1 - PHOTOGRAPHS OF RADIATED EMISSIONS MEASUR EMENTS PHOTO # 5 Siemens Milltronics SITRANS LR, Model No: 7ML5420 & 7ML5421 FCC ID: NJA-LR400-1 The Siemens Milltronics SITRAN S LR mounted on top of the m outh of the Concrete Tank ANNEX 1 - PHOTOGRAPHS OF RADIATED EMISSIONS MEASUR EMENTS PHOTO # 6 Siemens Milltronics SITRANS LR, Model No: 7ML5420 & 7ML5421 FCC ID: NJA-LR400-1 Carrier and spurious/harmonic emissions from the Siemens M illtronics SITRANS LR , which was mounted on top of the concrete tank, were scanned using a horn antenna at 0.2, 0.5, 1.0 and 3 meters distances.

Contact Information

Applicant

Thoai Bui(Approvals Specialist)
[email protected]705 868-1635Fax: 705 741-0466

Test Firm

UltraTech Engineering Labs Inc.Tri Luu
[email protected]905-829-1570Fax: 905-829-8050

Technical Specifications

#Rule PartsFrequency RangePower Output
115C24.20 GHz - 25.20 GHz0.00 µW
Confidentiality
Long Term

Other Applications from Siemens Canada Ltd. - Siemens Milltronics Process Instruments

SITRANS LR250 Level Probing Radar - FCC ID NJA-LR250 - Siemens Canada Ltd. - Siemens Milltronics Process Instruments
NJA-LR250

SITRANS LR250 Level Probing Radar

Aug 07, 2014

Equipment Class

LPR - Level Probing Radar
SITRANS LR260 Level Probing Radar - FCC ID NJA-LR260 - Siemens Canada Ltd. - Siemens Milltronics Process Instruments
NJA-LR260

SITRANS LR260 Level Probing Radar

Jul 27, 2014

Equipment Class

LPR - Level Probing Radar
SITRANS LR560 Tank Level Probing Radar - FCC ID NJA-LR560 - Siemens Canada Ltd. - Siemens Milltronics Process Instruments
NJA-LR560

SITRANS LR560 Tank Level Probing Radar

Dec 22, 2010

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
SITRANS LR 460 TANK LEVEL PROBING RADAR - FCC ID NJA-LR460 - Siemens Canada Ltd. - Siemens Milltronics Process Instruments
NJA-LR460

SITRANS LR 460 TANK LEVEL PROBING RADAR

Mar 08, 2006

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
Radar Level Gauge - FCC ID NJA-LR200 - Siemens Canada Ltd. - Siemens Milltronics Process Instruments
NJA-LR200

Radar Level Gauge

Apr 22, 2003

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter