Radar Transmitters Operating Instructions 11/2010 SITRANS LR560 (mA/HART) SITRANS Draft_Rev. 1.0-03 Firmware 1.00.00.32 © Siemens AG 2010 Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by a clarification of the level of caution to be observed. Qualified Personnel: This device/system may only be set up and operated in conjunction with this manual. Qualified personnel are only authorized to install and operate this equipment in accordance with established safety practices and standards. Unit Repair and Excluded Liability: • The user is responsible for all changes and repairs made to the device by the user or the user’s agent. • All new components are to be provided by Siemens Milltronics Process Instruments. • Restrict repair to faulty components only. • Do not reuse faulty components. Warning: Cardboard shipping package provides limited humidity and moisture protection. This product can only function properly and safely if it is correctly transported, stored, installed, set up, operated, and maintained. This product is intended for use in industrial areas. Operation of this equipment in a residential area may cause interference to several frequency based communications. Note: Always use product in accordance with specifications. Copyright Siemens AG 2010. All Rights Reserved Disclaimer of Liability This document is available in bound version and in electronic version. We encourage users to purchase authorized bound manuals, or to view electronic versions as designed and authored by Siemens Milltronics Process Instruments. Siemens Milltronics Process Instruments will not be responsible for the contents of partial or whole reproductions of either bound or electronic versions. While we have verified the contents of this manual for agreement with the instrumentation described, variations remain possible. Thus we cannot guarantee full agreement. The contents of this manual are regularly reviewed and corrections are included in subsequent editions. We welcome all suggestions for improvement. Technical data subject to change. MILLTRONICS®is a registered trademark of Siemens Milltronics Process Instruments. Contact SMPI Technical Publications European Authorized Representative at the following address: Technical Publications Siemens AG Siemens AG Industry Sector Siemens Milltronics Process Instruments 76181 Karlsruhe 1954 Technology Drive, P.O. Box 4225 Deutschland Peterborough, Ontario, Canada, K9J 7B1 Email: [email protected] • For a selection of Siemens Milltronics level measurement manuals, go to: www. siemens.com/processautomation. Under Process Instrumentation, select Level Measurement and then go to the manual archive listed under the product family. • For a selection of Siemens Milltronics weighing manuals, go to: www. siemens.com/processautomation. Under Weighing Technology, select Continuous Weighing Systems and then go to the manual archive listed under the product family. i mmmmm Table of Contents Ta b l e o f C o n t e n t s Safety Notes ...........................................................................................................................................1 Safety marking symbols ............................................................................................................1 FCC Conformity ......................................................................................................................................1 CE Electromagnetic Compatibility (EMC) Conformity ...................................................................2 Industry Canada ....................................................................................................................................2 The Manual ............................................................................................................................................3 Technical Support .................................................................................................................................3 SITRANS LR560 Overview ................................................................................................5 Programming ................................................................................................................................5 Local Display Interface (LDI) ....................................................................................................6 Versions ..................................................................................................................................................6 Applications ..................................................................................................................................6 Approvals and Certificates .......................................................................................................6 Specifications ....................................................................................................................7 Power ............................................................................................................................................. 7 Performance................................................................................................................................. 7 Interface ........................................................................................................................................ 8 Mechanical ................................................................................................................................... 8 Environmental .............................................................................................................................. 9 Process .......................................................................................................................................... 9 Approva…
Text truncated - open the document above for the full version.
Radar Transmitters Operating Instructions 10/2010 SITRANS LR560 (PROFIBUS PA) SITRANS Draft_1.0-02 Firmware 1.00.00-32 © Siemens AG 2010 Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by a clarification of the level of caution to be observed. Qualified Personnel: This device/system may only be set up and operated in conjunction with this manual. Qualified personnel are only authorized to install and operate this equipment in accordance with established safety practices and standards. Unit Repair and Excluded Liability: • The user is responsible for all changes and repairs made to the device by the user or the user’s agent. • All new components are to be provided by Siemens Milltronics Process Instruments. • Restrict repair to faulty components only. • Do not reuse faulty components. Warning: Cardboard shipping package provides limited humidity and moisture protection. This product can only function properly and safely if it is correctly transported, stored, installed, set up, operated, and maintained. This product is intended for use in industrial areas. Operation of this equipment in a residential area may cause interference to several frequency based communications. Note: Always use product in accordance with specifications. Copyright Siemens AG 2010. All Rights Reserved Disclaimer of Liability This document is available in bound version and in electronic version. We encourage users to purchase authorized bound manuals, or to view electronic versions as designed and authored by Siemens Milltronics Process Instruments. Siemens Milltronics Process Instruments will not be responsible for the contents of partial or whole reproductions of either bound or electronic versions. While we have verified the contents of this manual for agreement with the instrumentation described, variations remain possible. Thus we cannot guarantee full agreement. The contents of this manual are regularly reviewed and corrections are included in subsequent editions. We welcome all suggestions for improvement. Technical data subject to change. MILLTRONICS®is a registered trademark of Siemens Milltronics Process Instruments. Contact SMPI Technical Publications European Authorized Representative at the following address: Technical Publications Siemens AG Siemens AG Industry Sector Siemens Milltronics Process Instruments 76181 Karlsruhe 1954 Technology Drive, P.O. Box 4225 Deutschland Peterborough, Ontario, Canada, K9J 7B1 Email: [email protected] • For a selection of Siemens Milltronics level measurement manuals, go to: www. siemens.com/processautomation. Under Process Instrumentation, select Level Measurement and then go to the manual archive listed under the product family. • For a selection of Siemens Milltronics weighing manuals, go to: www. siemens.com/processautomation. Under Weighing Technology, select Continuous Weighing Systems and then go to the manual archive listed under the product family. i mmmmm Table of Contents Ta b l e o f C o n t e n t s Safety Notes .............................................................................................................................................1 Safety marking symbols ..............................................................................................................1 FCC Conformity ........................................................................................................................................1 CE Electromagnetic Compatibility (EMC) Conformity ....................................................................2 Industry Canada ......................................................................................................................................2 The Manual ...............................................................................................................................................3 Application Example .....................................................................................................................3 Technical Support ....................................................................................................................................3 Abbreviations and Identifications .......................................................................................................4 SITRANS LR560 Overview ................................................................................................. 6 Programming ............................................................................................................................................6 Local Display Interface (LDI) ......................................................................................................7 Versions .....................................................................................................................................................7 Applications ..............................................................................................................................................7 Approvals and Certificates ...................................................................................................................7 Specifications ...................................................................................................................... 8 Power ............................................................................................................................................. 8 Performance................................................................................................................................. 8 Interface ........................................................................................................................................ 9 Mechanical ...............................................................................................…
Text truncated - open the document above for the full version.
Radar Transmitters Operating Instructions 10/2010 SITRANS LR560 (Foundation Fieldbus) SITRANS Draft_Rev. 1.0-02 Firmware 1.00.00-32 © Siemens AG 2010 Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by a clarification of the level of caution to be observed. Qualified Personnel: This device/system may only be set up and operated in conjunction with this manual. Qualified personnel are only authorized to install and operate this equipment in accordance with established safety practices and standards. Unit Repair and Excluded Liability: • The user is responsible for all changes and repairs made to the device by the user or the user’s agent. • All new components are to be provided by Siemens Milltronics Process Instruments. • Restrict repair to faulty components only. • Do not reuse faulty components. Warning: Cardboard shipping package provides limited humidity and moisture protection. This product can only function properly and safely if it is correctly transported, stored, installed, set up, operated, and maintained. This product is intended for use in industrial areas. Operation of this equipment in a residential area may cause interference to several frequency based communications. Note: Always use product in accordance with specifications. Copyright Siemens AG 2010. All Rights Reserved Disclaimer of Liability This document is available in bound version and in electronic version. We encourage users to purchase authorized bound manuals, or to view electronic versions as designed and authored by Siemens Milltronics Process Instruments. Siemens Milltronics Process Instruments will not be responsible for the contents of partial or whole reproductions of either bound or electronic versions. While we have verified the contents of this manual for agreement with the instrumentation described, variations remain possible. Thus we cannot guarantee full agreement. The contents of this manual are regularly reviewed and corrections are included in subsequent editions. We welcome all suggestions for improvement. Technical data subject to change. MILLTRONICS®is a registered trademark of Siemens Milltronics Process Instruments. Contact SMPI Technical Publications European Authorized Representative at the following address: Technical Publications Siemens AG Siemens AG Industry Sector Siemens Milltronics Process Instruments 76181 Karlsruhe 1954 Technology Drive, P.O. Box 4225 Deutschland Peterborough, Ontario, Canada, K9J 7B1 Email: [email protected] • For a selection of Siemens Milltronics level measurement manuals, go to: www. siemens.com/processautomation. Under Process Instrumentation, select Level Measurement and then go to the manual archive listed under the product family. • For a selection of Siemens Milltronics weighing manuals, go to: www. siemens.com/processautomation. Under Weighing Technology, select Continuous Weighing Systems and then go to the manual archive listed under the product family. i mmmmm Table of Contents Ta b l e o f C o n t e n t s Safety Notes .............................................................................................................................................1 Safety marking symbols ..............................................................................................................1 FCC Conformity ........................................................................................................................................1 CE Electromagnetic Compatibility (EMC) Conformity ....................................................................2 Industry Canada ......................................................................................................................................2 The Manual ...............................................................................................................................................3 Application Example .....................................................................................................................3 Technical Support ....................................................................................................................................4 Abbreviations and Identifications .............................................................................................4 SITRANS LR560 Overview ................................................................................................. 6 Programming ............................................................................................................................................6 Local Display Interface (LDI) ......................................................................................................7 Versions .....................................................................................................................................................7 Applications ..............................................................................................................................................7 Approvals and Certificates ...................................................................................................................7 Specifications ...................................................................................................................... 8 Dimensions ............................................................................................................................................12 Universal Slotted Flange ...........................................................................................................16 Installation ......................................................................................................................... 17 Pressure Equipment Directive, PED, 97/23/EC ..........................................................................…
Text truncated - open the document above for the full version.
Federal Communications CommissionFCC 10-14 Before the Federal Communications Commission Washington, D.C. 20554 In the Matter of Amendment of Part 15 of the Commission’s Rules To Establish Regulations for Tank Level Probing Radars in the Frequency Band 77-81 GHz Siemens Milltronics Process Instruments Inc. Request for Waiver for Tank Level Probing Radars under Part 15 of the Commission’s Rules Ohmart/VEGA Corp., Request for Waiver of Section 15.205(a) of the Commission’s Rules to Permit Certification and Immediate Marketing of a Tank Level Probing Radar Operating in the Frequency Band 77-81 GHz ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ET Docket No. 10-23 RM-11352 ET Docket No. 06-216 ET Docket No. 07-96 NOTICE OF PROPOSED RULE MAKING AND ORDER Adopted: January 14, 2010Released: January 19,2010 Comment date: [Insert date 90 days after date of publication in the Federal Register] Reply Comment date: [Insert date 120 days after date of publication in the Federal Register] By the Commission: I.INTRODUCTION 1.In this Notice of Proposed Rulemaking and Order (Notice), we propose to modify our rules to allow tank level probing radar (TLPR) devices to operate in the 77-81GHzfrequency band on an unlicensed basis under the provisions of Part 15 of the Commission’s rules. Specifically, we propose to modify Section 15.205 of the rules to remove the prohibition on intentional emissions in the 77-81GHz band for TLPR devices used in closed storage tanks and vessels made of metal, concrete, or material with similar attenuating characteristics, at fixed locations at petroleum and chemical production and storage facilities, and similar commercial and industrial sites. 1 We believe that our proposals herein will enable the development and deployment of high frequency technology that operates more effectively and reliably than existing tank level measuring radar technology in certain applications where precision measurements are needed, and in certain tanks which cannot now accommodate existing technology. We believe that, with appropriate restrictions, such high frequency TLPR devices can operate on an unlicensed basis without causing harmful interference to authorized services in the 77-81GHz band. 2.Additionally, we are waiving Section 15.205(a) of our rules, subject to certain conditions, to allow Siemens Milltronics Process Instruments Inc. (Siemens), Ohmart/VEGA Corp. 1 47 C.F.R. §§ 15.205. Federal Communications CommissionFCC 10-14 2 (Ohmart/VEGA), and any other responsible party marketing equipment that complies with these conditions (e.g., Endress+Hauser GmbH+Co. KG (Endress+Hauser)) to manufacture, certify, and market TLPR devices in the 77-81GHz band for a period of twoyears or until 180days following the adoption of a Report and Order in this proceeding, whichever is longer. This action will allow the new TLPR technology to be utilized in the near term while we consider modifying our general Part15 rules. II.BACKGROUND 3.TLPR devices are used to measure the amount of various materials contained in storage tanks or vessels. TLPR transmitters are typically mounted on the inside top of storage tanks, and emit radio frequency (RF) signals through an antenna aimed downwards to the surface of the substance contained in the tanks. The TLPR device measures or calculates the time delay between the transmitted signal and the reception of the return echo reflected off the surface of the material being measured to determine the material’s level. The radar beam typically bounces and is scattered inside the tank, and is eventually absorbed by the tank’s content or walls. In closed tanks made of metal or concrete material, the main emissions outside the tank typically result from the leakage of the escaping radar signal through the transmitter enclosure or through the mounting flange of the TLPR device. 2 However, if the tank is open when the radar is operating, the radar signal canescape through any opening. Further, if the tank enclosure is made of a material that does not significantly attenuate the radar signal, unintentional emissions would also escape through the tank’s walls and the radar enclosure. 3 However, at millimeter wave frequencies, 4 signal propagation loss is significant within a very short distance of the source. 5 4.Most short-range TLPR devices on the market currently operate at 6GHz, 8-10GHz, 24GHz or 26GHz. 6 TLPR devices that could operate at higher frequencies would use antennas employing narrower beam widths. Narrower beams would avoid extraneous objects located in close proximity to the desired target, such as agitators or filling pipes, thereby resulting in increased accuracy in target resolution. 7 High frequency TLPR devices would thus provide more precise measurements, reducing 2 See Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD); Equipment for Detection and Movement; Tanks Level Probing Radar (TLPR) operating in the frequency bands 5,8 GHz, 10 GHz, 25 GHz, 61 GHz and 77 GHz; Part 1: Technical characteristics and test methods, European Telecommunications Standards Institute (ETSI) European Norm (EN) 302 372-1 V1.1.1 (2006-04), (ETSI TLPR Technical Standard) at 30. 3 Id., at 30. ETSI found that the signal attenuation through a metal tank wall is 5 dB to 10 dB per micrometer thickness and the attenuated signal through a concrete tank wall, with or without reinforcement, is negligible because the thickness and natural moisture content of the concrete provide high attenuation at these frequencies. 4 The term “millimeter wave” is taken from the fact that the wavelength of radio signals for frequencies between 30 GHz and 300 GHz ranges from 10 millimeters down to 1 millimeter. 5 There is approximately 80 dB of free space attenuation at 3 meters for an 80 GHz signal. 6 Siemens, Krohne, SAAB Rosemount Tank Radar AB, etc., are FMCW radars manufacturers. Ohmart/VEGA, Endress+Hauser, Inc., Enraf B.V., etc., are pulsed radars manufacturers. See, e.g., Ohmart/VEG…
Text truncated - open the document above for the full version.
Sulis Consultants Limited Mead House, Longwater Road, Eversley, Hampshire, RG27 0NW, UK Registered in England & Wales, number 05466247 http://www.sulisconsultants.com 13 th December2010 Federal Communications Commission Office of Engineering and Technology Equipment Authorization Division 7345 Oakland Mills Road Columbia, Maryland 21046 Subject: Confidentiality request for FCC ID:NJA-LR560 To Whom It May Concern, Pursuant to sections 0.457 and 0.459 and CFR 47, the applicant requests permanent confidential treatment of the following information accompanying this application: Schematics: 20100119 HART Main Bd Rev.6.0 Schem.pdf 20100119 Profi Main Bd Schematic Rev.5.0.pdf 20100819 Potter Tech Bd Schematic Rev.9.0.pdf A5E01032804-19 Potter Radar HFM Schematic.pdf A5E01031683B05 – display.pdf Parts List: A5E01048834LR560_Display.pdf a5e02788057_LR560_Hart_Main_board.pdf A5E02788064_LR560_Profi_Main_Board.pdf A5E02788071LR560_Tech_Main_Board.pdf a56e02788068_LR560_FF_Main_Board.pdf antenna_specs_LR560_v2.pdf Block Diagram: LR560_block_diagram.pdf Operational Description: LR560_Operational_description.pdf SITRAN LR560 variants Description.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. Yours Sincerely Charlie Blackham Director
SITRAN LR560 choice of units for testing Frequency band of operation and Duty cycle The frequency band of operation is determined by the DDS and VCO circuits on the Technology board which is common to all 3 TLPR variants. These devices are programmed by the Main board processor. The processor, associated circuitry and relevant part of the software is common to the 2 main board variants (HART and Profi/FF), as is the part of the software stack that controls it. The Duty cycle is programmed onto the radar board by the Main board CPLD. The CPLD, associated circuitry and relevant part of the software is common to the two main board variants. As the main boards in the 3 TLPR variants have different communication ports the software load actually loaded onto the units has to be different to accommodate this, so these test are performed on all 3 variants. AC Mains conducted emissions None of the 3 units connect directly to ac mains and draw only a few mAfrom their DC supplies. Pre-testing during development showed that all unit passed conducted emissions with good margin and HART variant was chosen for mains conducted emissions test. Following on from testing to FCC 15.207 and 15.209 at RFI global, EMC testing was performed at Global EMC Inc to CISPR 11 and FCC 15.107. Results are presented in reports GEMC-61326-H-19966R3, GEMC-61326-PA-19966R3and GEMC-61326-FF- 19966R3which confirm that HART variant was worst dc port conducted emissions so was the variants chosen for ac mains conducted emissions. Radiated Emissions The TLPR housing is a single piece of deep-drawn stainless steel with an aperture at the bottom for the 78 GHz radar and a glass window at the top so that the display may be seen. Pre-testing during development had shown that the HART variant was worst case radiated emissions and so was the variant chosen for testing Following on from testing to FCC 15.207 and 15.209 at RFI global, radiated EMC testing was performed at Global EMC Inc to CISPR 11 and 15.109. Results are presented in reports GEMC-61326-H-19966R3, GEMC-61326-PA-19966R3and GEMC-61326-FF- 19966R3which confirm that HART variant was worst case radiated emissions.
External Photos FCC ID: NJA-LR560, IC:267P-LR560 1 External Photos FCC ID: NJA-LR560, IC:267P-LR560 2 External Photos FCC ID: NJA-LR560, IC:267P-LR560 3 External Photos FCC ID: NJA-LR560, IC:267P-LR560 4
Product Group FOR INTERNAL USE ONLY PETERBOROUGH 1 : 1 11 1 :1 A 2 FOR RELEASE PER ECO 79B57508 CHANGES PER ECO 79C64568 A5E01382954A02 S. NGUYEN 03 / FEBRUARY / 2010 RADAR 1 2 T. COUPLAND R. CLYSDALE LR560, FF CSA / FM Class II Div 1, Class I Div 2 NAMEPLATE DRAWING A5E01382954 RPC MLB SN SN FEB 03/2010 OCT 25 2010 214 42 NOTES: 1) NAMEPLATE INFORMATION TO APPEAR CENTERED 2) COLOUR: ALL TEXT & ARTWORK TO BE BLACK ON SILVER 3) ENGRAVING PROCESS IS Nd:YAG LASER MARKING. 4) 5) SERIAL NUMBER SHOWN IS FOR EXAMPLE ONLY. CHARACTER 5 ENCODES YEAR OF MANUFACTURE. REFER TO EN 60062 - TWENTY YEAR CYCLE (IE: V = 2007, W = 2008, X = 2009, A = 2010, B = 2011, C = 2012) ON METAL HOUSING OPPOSITE CONDUIT ENTRY IN THE PRODUCT CONFIGURATION NUMBER EXAMPLE, x’s ARE PLACE HOLDERS FOR ALPHANUMERIC CHARACTERS. outline and center line for reference only NAMEPLATE TO BE CENTERED ON THIS PART OF THE HOUSING 8 mm DOWN FROM UPPER EDGE 159134 SITRANS LR560 7MLxxxx-xxxxx-xxxx-xx SERIAL NO.: GYZ / A1034567 ENCLOSURE: NEMA / TYPE 4X, 6; IP68 AMB. TEMP. : – 40°C to 80°C INPUT : 32 V MAX., 13 OUTPUT : FOUNDATION FIELDBUS 5 mA Made in Canada Siemens Milltronics Process Instruments Inc., Peterborough FCC ID: NJA-LR560 IC: 267P- LR560 THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: 1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND 2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION CLASS II, DIV. 1, GR. E, F, G CLASS III, T4 CLASS I, DIV. 2 GR. A, B, C, D TEMP. CODE: T4 REFER TO INSTALLATION DWG. A5E02795836 888 s . Product Group FOR INTERNAL USE ONLY PETERBOROUGH 1 : 1 11 1 :1 A 2 FOR RELEASE PER ECO 79B57508 CHANGES PER ECO 79C64568 A5E01383048A02 S. NGUYEN 03 / FEBRUARY / 2010 RADAR 1 2 T. COUPLAND R. CLYSDALE LR560, HART CSA / FM Class II Div 1, Class I Div 2 NAMEPLATE DRAWING A5E01383048 RPC MLB SN SN FEB 03 / 2010 OCT 25 2010 214 42 NOTES: 1) NAMEPLATE INFORMATION TO APPEAR CENTERED 2) COLOUR: ALL TEXT & ARTWORK TO BE BLACK ON SILVER 3) ENGRAVING PROCESS IS Nd:YAG LASER MARKING. 4) 5) SERIAL NUMBER SHOWN IS FOR EXAMPLE ONLY. CHARACTER 5 ENCODES YEAR OF MA…
Text truncated - open the document above for the full version.
Mead House · Eversley · United Kingdom
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 78.00 GHz - 79.30 GHz | 1.04 W |

SITRANS LR250 Level Probing Radar
Equipment Class
LPR - Level Probing Radar
SITRANS LR260 Level Probing Radar
Equipment Class
LPR - Level Probing Radar
SITRANS LR 460 TANK LEVEL PROBING RADAR
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
RADAR LAVEL GAUGE
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Radar Level Gauge
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter