Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
EZCOM-LP Professional Installers Guide Version 1.5 Grayhill Inc. 561 Hillgrove Ave LaGrange, IL 60525 800-426-4383 www.grayhill.com Table Of Contents TABLE OF CONTENTS.................................................................................................................................. 2 FCC INFORMATION....................................................................................................................................... 3 Preface..................................................................................................................................................................................................................... 3 RF Exposure Information ..................................................................................................................................................................................... 3 Physical Installation ............................................................................................................................................................................................... 3 Electrical Issues ...................................................................................................................................................................................................... 4 Antennas ................................................................................................................................................................................................................. 4 Yagi Installation................................................................................................................................................................................................... 4 Omni Installation.................................................................................................................................................................................................. 5 Mobile Installation ............................................................................................................................................................................................... 5 Thermal Considerations ....................................................................................................................................................................................... 6 FCC Information Compliance Statement ( Part 15.19 ) This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Warning ( Part 15.21 ) Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. RF Exposure ( OET Bulletin 65 ) To comply with FCC RF exposure requirements for mobile transmitting devices, this transmitter should only be used or installed at locations where there is at least 2m separation distance between the antenna and all persons. Preface EZCom-LP is an OEM radio module for professional installation in products or assemblies for resale. This device is not intended or marketed for installation by end users. Should EZCom-LP be used for fixed point-to-point operation as defined in FCC rule 15.247.(b).iii the equipment operator, or if the equipment is professionally installed, the installer, is responsible for ensuring the system is used exclusively for point-to-point operations. RF Exposure Information When used in a fixed configuration with the Yagi antenna or a mobile configuration with the omni-directional antenna the antenna should be located at least 2 meters from normal human proximity. Physical Installation The unit should be firmly attached at four mounting points. The holes are sized for #6 screws and are 5.7” apart on in the long dimension and 1.125” apart in the short dimension. It is critical that the mounting method not touch any of the components mounted on the PCB. Vibration mounts should be used if the device is expected to see shock or vibration in excess of 1G. The SMA connectors should be secured with 8 ounce-inches of torque. Ensure that the cabling does not present more than a few pounds of stress to the connectors themselves. With enough leverage, (such as seen with 0.5” and larger coax) it is possible to break the solder joints on the connectors. Electrical Issues The system supply must be 5V +/- 2%. As the main power amplifier runs directly off the 5V supply with only passive filtering it’s important to keep the voltage within these limits. Under voltage will cause the unit’s microprocessor to enter reset mode. Over voltage could potentially damage the transmit section. A power supply able to deliver at least 1 Ampere should be used. Place the supply close to the radio (less than 3 feet), use 22 gauge or larger wire and if possible provide a 470uF or larger capacitor between power and ground where it enters the radio. The capacitor isn’t needed if the supply can be shown not to droop out of voltage tolerance when the radio transmits. Antennas Use only the following antennas: Antenex YB8966 9.2 dBd yagi, must have at least 2.3 dB of cable loss (60 feet of LMR400, or equiv.) Maxrad MFB9157 7 dBd omni, must have at least 0.2 dB of cable loss (5 feet of LMR400, or equiv.) Antennas of the same type but with lower gain may be substituted if desired so long as the cable lengths are not changed from those tested. Antennas of higher gain are prohibited. Contact Grayhill if you feel you must use a higher gain antenna. Yagi Installation Figure 1. Recommended Antenex Yagi antenna configuration. The Yagi antenna should be mounted on a tower or pole with clear line of sight to the target radios. As a Yagi antenna concentrates it’s gain along the direction of the long axis care should be tak…
Text truncated - open the document above for the full version.
561 Hillgrove Avenue • LaGrange, Illinois • 60525-5997 • U.S.A. Phone: (708) 354-1040 • Fax: (708) 354-2820 • http://www.grayhill.com F C C CONFIDENTIALITY Date: 1/28/2003 To:FEDERAL COMMUNICATIONS COMMISSION 7435 Oakland Mills Road Columbia, MD 21046 Subject: Request for Non disclosure for FCC ID: _NMA - EZCOMLPM__________. To Whom It May Concern: Pursuant to 47 CFR Section 0.459, Grayhill Inc. hereby requests non disclosure and confidential treatment of the following materials submitted in support of FCC certification application for FCC ID # NMA-EZCOMLPM. a. Schematic Diagrams b. Operational Description c. Block Diagram Above materials contain trade secrets, proprietary and technical information which would customarily be guarded from competitors under 47 CFR section 0.457(d)(2). Disclosure or publication of any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. Grayhill Inc. understands that pursuant to 47 CFR section 0.457(d)(1)(ii) disclosure of the applicant and all accompanying documentation will not be made before the date of the grant. Sincerely yours, Chris Anderson, Staff Engineer Grayhill Inc. _______________________________________________________________________
Grayhill Incorporated EZCom-LP 900 MHz Digital Radio FCC ID#: NMAEZCOMLPM Photo One RF 900 MHz Digital Radio with Shielding and FCC ID Label Note: This 900 MHz Digital Radio is filed as a FCC Mobile Classification to be used with Grayhill’s OCU - Remote Control Unit filed with the FCC as FCC ID#: NMAEZCOMLPP. Grayhill Incorporated EZCom-LP 900 MHz Digital Radio FCC ID#: NMAEZCOMLPM Photo Two FCC ID Label Close-up Note: This 900 MHz Digital Radio is filed as a FCC Mobile Classification to be used with Grayhill’s OCU - Remote Control Unit filed with the FCC as FCC ID#: NMAEZCOMLPP.
LCR Label and Material Composition Product Data DAIRY LABEL/DL-50/40# FS FACESTOCK FM Litho: A medium gloss bleached hardwood and softwood kraft stock that is super-calendered and coated one side for high internal strength. Basis Weight: 60# per ream + 10% Tensile: MD 27# per inch width {500 sheets 25” x 38”} CD 13# per inch width Caliper: 0.0034 inches + 10% Tear: MD 45 grams per sheet CD 50 grams per sheet ADHESIVE DL-50 is a permanent adhesive specifically formulated and designed for adhesion to HDPE (high density polyethylene) milk jugs and other applications with similar surfaces. Minimum Application Temperature: +25°F Type: Hot Melt Rubber Service Temperature Range: -65°F to +160°F LINER 40# FS: A bleached supercalendered kraft stock featuring high internal strength, toughness and tear resistance. Basis Weight: 41# per ream + 10% Tensile: MD 35# per inch width {500 sheets 24” x 36”} CD 16# per inch width Caliper: 0.0025 inches + 10% Tear: MD 35 grams per sheet CD 45 grams per sheet TOTAL CONSTRUCTION CALIPER: 0.0066 inches + 10% SHELF LIFE: One year when stored at 72°F/50% R.H. As with all pressure-sensitive materials, this product should be tested thoroughly under end-use conditions to make sure it meets the requirements of the specific application.
Grayhill Incorporated EZCom-LP 900 MHz Digital Radio FCC ID#: NMAEZCOMLPM Photo Three RF PCB Shield Removed for Inspection Note: This 900 MHz Digital Radio is filed as a FCC Mobile Classification to be used with Grayhill’s OCU - Remote Control Unit filed with the FCC as FCC ID#: NMAEZCOMLPP. Grayhill Incorporated EZCom-LP 900 MHz Digital Radio FCC ID#: NMAEZCOMLPM Photo Four Flip Side of RF PCB with Shield Removed for Inspection Note: This 900 MHz Digital Radio is filed as a FCC Mobile Classification to be used with Grayhill’s OCU - Remote Control Unit filed with the FCC as FCC ID#: NMAEZCOMLPP. Grayhill Incorporated EZCom-LP 900 MHz Digital Radio FCC ID#: NMAEZCOMLPM Photo Five Yagi Antenna as one of two available for this RF 900 MHz Digital Radio’s Application Note: This 900 MHz Digital Radio is filed as a FCC Mobile Classification to be used with Grayhill’s OCU - Remote Control Unit filed with the FCC as FCC ID#: NMAEZCOMLPP. Grayhill Incorporated EZCom-LP 900 MHz Digital Radio FCC ID#: NMAEZCOMLPM Photo Six Stacked Dipole / Collinear Array Antenna as one of two available for this RF 900 MHz Digital Radio’s Application Note: This 900 MHz Digital Radio is filed as a FCC Mobile Classification to be used with Grayhill’s OCU - Remote Control Unit filed with the FCC as FCC ID#: NMAEZCOMLPP. Grayhill Incorporated EZCom-LP 900 MHz Digital Radio FCC ID#: NMAEZCOMLPM Photo Seven Stacked Dipole / Collinear Array Antenna Close-up of RF Connection to RF PCB as one of two available for this RF 900 MHz Digital Radio’s Application Note: This 900 MHz Digital Radio is filed as a FCC Mobile Classification to be used with Grayhill’s OCU - Remote Control Unit filed with the FCC as FCC ID#: NMAEZCOMLPP. Grayhill Incorporated EZCom-LP 900 MHz Digital Radio FCC ID#: NMAEZCOMLPM Photo Eight Stacked Dipole / Collinear Array Antenna Close-up of RF Connection to RF PCB as one of two available for this RF 900 MHz Digital Radio’s Application showing Detailed Warning Label. Note: This 900 MHz Digital Radio is filed as a FCC Mobile Classification to be used with Grayhill’s OCU - Remote Control Unit filed with the FCC as FCC ID#: NMAEZCOMLPP.
TM An ISO-9001 Registered Company ORDER (800) 323-9122 FAX (630) 372-8077 www.maxrad.com 105 Base Station Antennas 900 MHz MFB Series, 900 MHz Fiberglass Omnidirectional Antennas The MFB 900 MHz series consists of base matched half wave antennas encapsulated in heavy duty fiberglass radomes with a thick walled aluminum mounting base for reliable long term use. All models are DC grounded and UPS shippable. Features •White ultra-violet resistant pultruded fiberglass radome •Thick walled aluminum mounting base •Unity/3dB/5dB/7dB models (rated in dbd) •UPS shippable •Exceptional value General Specifications: Radiator Material: Coated steel wire Radome Material: .65” pultruded white fiberglass Termination: Unity and 3dB models: N Female 5dB and 7dB models: N male with 16” jumper RPC: reverse polarity TNC Lightning Protection: DC grounded Mounting Method: Mast or wall mounted. Mounting hardware is sold separately. MMK1: light duty mast mount for antennas under 30” MMK3: light duty mast mount for antennas over 30” MMK4: heavy duty mast mount MMK6: cast mounting bracket MBSWM: wall mounting bracket for antennas over 30” (two are required) Wind Survival: 100 mph Mounting Base Diameter: 1-5/16” Maximum Power: 150 Watts Nominal Impedance: 50 Ohms MFB9153PRC MMK3 MMK1 MMK4 MBSWM MMK6 ORDER (800) 323-9122 FAX (630) 372-8077 www.maxrad.com An ISO-9001 Registered Company Electrical Specifications Mechanical Specifications Specifications #ledoM talFtnelaviuqE aerAetalP tsurhTlaretaL dniWdetaR@ tnemoMgnidneB dniWdetaR@thgieHthgieWecirPtsiL 0698BFMtfqs60.sbl3.2sbl-tf4.1"41sbl57.04.88$ 0519BFMtfqs60.sbl3.2sbl-tf4.1"41sbl57.04.88$ 0039BFMtfqs60.sbl3.2sbl-tf4.1"41sbl57.04.88$ 0839BFMtfqs60.sbl3.2sbl-tf4.1"41sbl57.04.88$ 3698BFMtfqs21.sbl3.4sbl-tf7.4"62sbl52.106.231$ 3519BFMtfqs21.sbl3.4sbl-tf7.4"52.32sbl52.106.231$ 3039BFMtfqs21.sbl3.4sbl-tf7.4"62sbl52.106.231$ 3839BFMtfqs21.sbl3.4sbl-tf7.4"62sbl52.106.231$ *5698BFMtfqs22.sbl0.8sbl-tf2.41"84sbl57.108.671$ *5519BFMtfqs22.sbl0.8sbl-tf2.41"84sbl57.108.671$ *5039BFMtfqs22.sbl0.8sbl-tf2.41"84sbl57.108.671$ *5839BFMtfqs22.sbl0.8sbl-tf2.41"84sbl57.108.671$ *7698BFMtfqs44.sbl8.51sbl-tf5.26"69sbl00.484.491$ *7519BFMtfqs44.sbl8.51sbl-tf5.26"69sbl00.484.491$ *7039BFMtfqs44.sbl8.51sbl-tf5.26"69sbl00.484.491$ *7839BFMtfqs44.sbl8.51sbl-tf5.26"69sbl00.484.491$ CPR3519BFMtfqs21.sbl3.4sbl-tf7.4"52.32sbl52.192.541$ CPRTS3519BFMtfqs21.sbl3.4sbl-tf7.4"52.32sbl52.192.541$ CPR7519BFMtfqs44.sbl8.51sbl-tf5.26"69sbl00.446.012$ 00.01$ddarotcennocelameFNroF* #ledoM ycneuqerF egnaR denuTyrotcaF ycneuqerFniaG htdiwdnaB RWSV1:5.1@ lacitreV htdiwmaeB rewoP2/1@ 0698BFMzHM049-698zHM898ytinUzHM04°57 0519BFMzHM829-209zHM519ytinUzHM02°57 0039BFMzHM239-829zHM039ytinUzHM5°57 0839BFMzHM049-698zHM839ytinUzHM04°57 3698BFMzHM049-698zHM898Bd3zHM03°04 3519BFMzHM829-209zHM519Bd3zHM02°04 3039BFMzHM239-829zHM039Bd3zHM5°04 3839BFMzHM049-698zHM839Bd3zHM03°04 5698BFMzHM049-698zHM898Bd5zHM02°22 5519BFMzHM829-209zHM519Bd5zHM02°22 5039BFMzHM239-829zHM039Bd5zHM5°22 5839BFMzHM049-698zHM839Bd5zHM02°22 7698BFMzHM049-698zHM898Bd7zHM02°71 7519BFMzHM829-209zHM519Bd7zHM02°71 7039BFMzHM239-829zHM039Bd7zHM5°71 7839BFMzHM049-698zHM839Bd7zHM02°71 CPR3519BFMzHM829-209zHM519Bd3zHM02°04 CPRTS3519BFMzHM829-209zHM519Bd3zHM02°04 CPR7519BFMzHM049-698zHM519Bd7zHM02°71 TM 106
TITLE: Grayhill MPE CALCULATION PROJECT: GRAYHILL EZ-COM LPM CERTIFICATION W66 N220 COMMERCE COURT CEDARBURG, WI 53012, USA (262)-375-4400 FAX: (262)-375-6731 email: [email protected], http://www.lsr.com DRAWN BY: JOHN LOFGREN SR. ENGR. DATE: March 10, 2003 CHECKED BY: BRIAN PETTED VP ENG DATE: March 10, 2003 APPROVED BY: BRIAN PETTED VP ENG DATE: March 10, 2003 SIZE: A DRAWING NUMBER: GRAYHILL-MPE-V1.0 REVISION: 0.5 FILENAME, FILES AFFECTED: Grayhill_MPE_Calculation_v0.51 May 29.doc SCALE: NOT TO SCALE SHEET: 1 OF 6 MPE CALCULATION Grayhill FCC ID: NMAEZCOMLPM TITLE: GRAYHILL MPE CALCULATION PROJECT: GRAYHILL EZ-COM LPM CERTIFICATION W66 N220 COMMERCE COURT CEDARBURG, WI 53012, USA (262)-375-4400 FAX: (262)-375-6731 email: [email protected], http://www.lsr.com FILENAME, FILES AFFECTED: Grayhill_MPE_Calculation_v0.51 May 29.doc REVISION: 0.5 PAGE: 2 OF 6 TABLE OF CONTENTS 1.0 SCOPE.......................................................................................................3 2.0 REVISION CONTROL ...............................................................................3 3.0 APPLICABLE DOCUMENTS .....................................................................3 4.0 MAXIMUM PERMISSIBLE EXPOSURE CALCULATIONS........................4 TITLE: GRAYHILL MPE CALCULATION PROJECT: GRAYHILL EZ-COM LPM CERTIFICATION W66 N220 COMMERCE COURT CEDARBURG, WI 53012, USA (262)-375-4400 FAX: (262)-375-6731 email: [email protected], http://www.lsr.com FILENAME, FILES AFFECTED: Grayhill_MPE_Calculation_v0.51 May 29.doc REVISION: 0.5 PAGE: 3 OF 6 1.0 SCOPE This report demonstrates the Maximum Permissible Exposure (MPE) Calculation required for an Intentional Radiator equipment authorization. 2.0 REVISION CONTROL DATE CHANGES REVISION 03/10/03 ORIGINAL RELEASE 0.0 03/19/03 ADD CALCULATIONS FOR MOBILE UNITS, CHANGE PRESENTATION FORMAT 0.1 03/31/03 CORRECT ANTENNA GAIN AND SEPARATION DISTANCE MISPRINTS FOR YAGI AND OMNI ANTENNAS 0.2 04/03/03 CORRECT DISTANCES FROM 3000CM TO 300CM IN YAGI AND OMNI CALCULATIONS 0.3 04/08/03 CHANGE DISTANCE FOR YAGI AND OMNI FROM 3 m TO 2m 0.4 04/08/03 CORRECT YAGI GAIN FROM 9.9 dbd TO 9.2 dbd 0.5 3.0 APPLICABLE DOCUMENTS [1] “Code of Federal Regulations Title 47, Volume 1, Sec. 1.1310 Radiofrequency radiation exposure limits” 47CFR1.1310, Revised as of October 1, 2001, Page 297-298. [2] “Code of Federal Regulations Title 47, Volume 1, Sec. 2.1091 Radiofrequency radiation exposure evaluation: mobile devices.” 47CFR2.1091, Revised as of October 1, 2001, Page 588-589. [3] “Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields”, Supplement C, OET Bulletin 65, Edition 97-01 TITLE: GRAYHILL MPE CALCULATION PROJECT: GRAYHILL EZ-COM LPM CERTIFICATION W66 N220 COMMERCE COURT CEDARBURG, WI 53012, USA (262)-375-4400 FAX: (262)-375-6731 email: [email protected], http://www.lsr.com FILENAME, FILES AFFECTED: Grayhill_MPE_Calculation_v0.51 May 29.doc REVISION: 0.5 PAGE: 4 OF 6 4.0 MAXIMUM PERMISSIBLE EXPOSURE CALCULATIONS Equation from page 18 of OET Bulletin 65, Edition 97-01 where:S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna Maximum peak output power at antenna input terminal: 27.0 (dBm) Maximum peak output power at antenna input terminal: 501.19 (mW) Antenna gain(typical): 0.0 (dBi) Maximum antenna gain: 1.00 (numeric) Prediction distance: 10 (cm) Prediction frequency: 915 (MHz) MPE limit for uncontrolled exposure at prediction frequency: 0.61 (mW/cm 2 ) Power density at prediction frequency: 0.40 (mW/cm 2 ) Maximum allowable antenna gain: 1.85 (dBi) Mar gin of Compliance at 10cm = 1.83 dB 2 4R PG S π = Calculation 1. Portable unit with 0 dBi helical antenna and 10 cm separation. TITLE: GRAYHILL MPE CALCULATION PROJECT: GRAYHILL EZ-COM LPM CERTIFICATION W66 N220 COMMERCE COURT CEDARBURG, WI 53012, USA (262)-375-4400 FAX: (262)-375-6731 email: [email protected], http://www.lsr.com FILENAME, FILES AFFECTED: Grayhill_MPE_Calculation_v0.51 May 29.doc REVISION: 0.5 PAGE: 5 OF 6 Equation from page 18 of OET Bulletin 65, Edition 97-01 where:S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna Maximum peak output power at antenna input terminal:27.00 (dBm) Maximum peak output power at antenna input terminal:501.19 (mW) Antenna gain(typical):9.14 (dBi) Maximum antenna gain:8.20 (numeric) Prediction distance:200 (cm) Prediction frequency:915 (MHz) MPE limit for uncontrolled exposure at prediction frequency:0.6 (mW/cm 2 ) Power density at prediction frequency: 8.180 ( μ W/cm 2 ) Maximum allowable antenna gain: 27.79(dBi) Mar gin of Compliance at 2m = 18.7dB 2 4R PG S π = Calculation 2. Mobile unit with 7 dBd (9.14 dBi) omnidirectional antenna and 2 meter separation. TITLE: GRAYHILL MPE CALCULATION PROJECT: GRAYHILL EZ-COM LPM CERTIFICATION W66 N220 COMMERCE COURT CEDARBURG, WI 53012, USA (262)-375-4400 FAX: (262)-375-6731 email: [email protected], http://www.lsr.com FILENAME, FILES AFFECTED: Grayhill_MPE_Calculation_v0.51 May 29.doc REVISION: 0.5 PAGE: 6 OF 6 Equation from page 18 of OET Bulletin 65, Edition 97-01 where:S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna Maximum peak output power at antenna input terminal:27.00 (dBm) Maximum peak output power at antenna input terminal:501.19 (mW) Antenna gain(typical):11.34 (dBi) Maximum antenna gain:13.61 (numeric) Prediction distance:200 (cm) Prediction frequency:915 (MHz) MPE limit for uncontrolled exposure at prediction frequency:0.6 (mW/cm 2 ) Power density at prediction frequency: 13.575 ( μ W/cm 2 ) Maximum allowable antenna gain: 27.79(dBi) Mar gin of Compliance at 2m = 16.5dB 2 4R PG …
Text truncated - open the document above for the full version.
L.S. Compliance, Inc. W66 N220 Commerce Court Cedarburg, WI 53012 262-375-4400 Fax: 262-375-4248 COMPLIANCE TESTING OF: 900 MHz Mobile EZ-Com DSSS Radio Transceiver PREPARED FOR: Grayhill 561 Hillgrove Avenue La Grange, IL 60525 TEST REPORT NUMBER: 303122 TX Rev. 3 TEST DATE: February 10 th – 12 th and April 11 th , 2003 All results of this report relate only to the items that were tested. This report is not to be reproduced, except in full, without written approval of L. S. Compliance, Inc. L.S. Compliance, Inc. CONFIDENTIAL Page 2 of 31 Test Report Number: Grayhill Prepared For: 303122 Rev. 3 Table of Contents Section Description Test Type Page Index 2 1 L. S. Compliance in Review 3 2 A2LA Certificate of Accreditation 4 3 A2LA Scope of Accreditation 5 4 Validation Letter-U.S. Competent Body for EMC Directive 89/336/EEC 6 5 Signature Page 7 6 Product and General Information 8 7 Product Description 8 8 Test Requirements 8 9 Summary of Test Report 9 10 Introduction 9 11 Purpose 9 12 Radiated Emissions Test FCC 10-19 13 Conducted Emissions Test (AC Line) FCC 20-23 14 Conducted Emissions Test, Power Output FCC 24 15 Conducted Emissions Test, Spurious Emissions FCC 25-26 16 Conducted Emissions Test, Occupied Bandwidth FCC 27-28 17 Conducted Emissions Test, Power Spectral Density FCC 29-30 Appendix A Test Equipment List 31 L.S. Compliance, Inc. CONFIDENTIAL Page 3 of 31 Test Report Number: Grayhill Prepared For: 303122 Rev. 3 1. L. S. Compliance In Review L. S. Compliance, Inc. is located in Cedarburg, Wisconsin – United States. We may be contacted by: Mail: L. S. Compliance, Inc. W66 N220 Commerce Court Cedarburg, Wisconsin 53012 Phone: 262-375-4400 Fax: 262-375-4248 E-mail: [email protected] As an EMC Testing Laboratory, our Accreditation and Assessments are recognized through the following: A2LA – American Association for Laboratory Accreditation Accreditation based on ISO/IEC 17025 : 2005 with Electrical (EMC) Scope of Accreditation A2LA Certificate Number: 1255.01 U. S. Conformity Assessment Body (CAB) Validation Validated by the European Commission as a U. S. Conformity Assessment Body operating under the U. S. /EU, Mutual Recognition Agreement (MRA) operating under the European Union EMC Directive 89/336/EEC, Article 10.2. Date of Validation: January 16, 2001 Federal Communications Commission (FCC) – USA Listing of 3 Meter Semi-Anechoic Chamber based on 47CFR 2.948 FCC Registration Number: 90756 Listing of 3 and 10 meter OATS based on 47CFR 2.948 FCC Registration Number: 90757 Industry Canada On-file, 3 Meter Semi-Anechoic Chamber based on 47CFR 2.948 File Number: IC 3088 On-file 3 and 10 Meter OATS based on RSS-210 File Number: IC 3088-A L.S. Compliance, Inc. CONFIDENTIAL Page 4 of 31 Test Report Number: Grayhill Prepared For: 303122 Rev. 3 2. A2LA Certificate of Accreditation L.S. Compliance, Inc. CONFIDENTIAL Page 5 of 31 Test Report Number: Grayhill Prepared For: 303122 Rev. 3 3. A2LA Scope of Accreditation L.S. Compliance, Inc. CONFIDENTIAL Page 6 of 31 Test Report Number: Grayhill Prepared For: 303122 Rev. 3 4. Validation Letter – U.S. Competent Body for EMC Directive 89/336/EEC L.S. Compliance, Inc. CONFIDENTIAL Page 7 of 31 Test Report Number: Grayhill Prepared For: 303122 Rev. 3 5. Signature Page Prepared By: March 10, 2003 Teresa A. White, Document Coordinator Date Tested By: March 10, 2003 Abtin Spantman, EMC Engineer Date Tested By: March 10, 2003 Thomas T. Smith, EMC Engineer Date March 10, 2003 Approved By: Kenneth L. Boston, EMC Lab Manager Date PE #31926 Licensed Professional Engineer Registered in the State of Wisconsin, United States L.S. Compliance, Inc. CONFIDENTIAL Page 8 of 31 Test Report Number: Grayhill Prepared For: 303122 Rev. 3 6. Product and General Information Manufacturer: Grayhill Model No.: WLAD 1166 (Rev. A) Serial No.: 501 Description: 902 to 928 Direct Sequence Spread Spectrum Transceiver 7. Product Description The EZCom is DSSS Radio Transceiver is an OEM for professional installation in products or assemblies for resale. This device is not intended or marketed for installation by end users. The EUT is a 902 to 928 MHz Direct Sequence Spread Spectrum Transceiver. 8. Test Requirements The above mentioned tests were performed in order to determine the compliance of the transceiver with limits contained in various provisions of Title 47 CFR, FCC Part 15, including: 15.207 15.247b 15.247e 15.205 15.247c 15.209 15.247a2 15.247d All radiated emissions tests were performed to measure the emissions in the frequency bands described by the above sections, and to determine whether said emissions are below the limits established by the above sections. These tests were performed in accordance with the procedure described in the American National Standard for methods of measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz (ANSI C63.4-2001). Another document used as reference for the EMI receiver specification was the International Special Committee on Radio Interference CISPR 16-1 (2002). Measurement technique guidelines found in Appendix C to FCC 97-114 were also consulted. During all tests, the transceiver was operated in a continuous data transmit mode, on various channels. L.S. Compliance, Inc. CONFIDENTIAL Page 9 of 31 Test Report Number: Grayhill Prepared For: 303122 Rev. 3 9. Summary of Test Report DECLARATION OF CONFORMITY The Grayhill Receiver was found to MEET the requirements as described within the specification of Title 47 CFR FCC, Part 15.247, Subpart c; and I.C. RSS-210, Section 7 for an intentional radiator. 10. Introduction On February 10 th – 13 th and April 11 th , 2003 a series of Radiated Emission tests were performed on one sample of the Receiver, Model Number WLAD 1166 (Rev. A), Serial Number 501, here forth referred to as the “Equipment Under Test” or “EUT”. These tests were performed using the procedures outlined in ANSI C63.4-2001 for low power transmitters, and in accordance …
Text truncated - open the document above for the full version.
L.S. Compliance, Inc. CONFIDENTIAL Page 14 of 31 Test Report Number: Grayhill Prepared For: 303122 Rev. 3 Photos Taken During Radiated Emission Testing Setup for the Radiated Emissions Test, view with yagi transmit antenna (Case #1) View of the EUT during Radiated Emission Testing in the 3 Meter FCC Listed Chamber L.S. Compliance, Inc. CONFIDENTIAL Page 15 of 31 Test Report Number: Grayhill Prepared For: 303122 Rev. 3 Photos Taken During Radiated Emission Testing Setup for the Radiated Emissions Test, close-up view View of Radiated Emissions Test, item tested with 2 nd transmit antenna case
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 902 MHz - 928 MHz | 450.00 mW |

Rugged Industrial PDA
Equipment Class
DTS - Digital Transmission System
Industrial Handheld Computer
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Rugged Industrial PDA
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Data Radio Module
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
EZCom-LPP
Equipment Class
DTS - Digital Transmission System