Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jan 09, 2013
Application Purpose
Original Equipment
Date of Application
Jan 09, 2013
Equipment Note
Bosch Bluetooth blood pressure monitor
Frequency Range
2402.00000000 - 2480.00000000
Company
IDT Technology Limited
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

DRAFTDRAFT en Instructions for Use es Instrucciones de uso fr Mode d’emploi de Gebrauchsanleitung Blood Pressure Monitor BP5000 BT Contents 1. Introduction ......................................................................................................1 2. List of parts.......................................................................................................2 3. Overview of symbols and functional features ...................................................3 4. Setting up your blood pressure monitor ...........................................................5 4.1 Installing the batteries ..............................................................................5 4.2 Connecting the arm cuff to your blood pressure monitor ........................6 4.3 Setting up the wireless connection ..........................................................7 5. Measuring your blood pressure ........................................................................8 6. Error messages on your blood pressure monitor ............................................12 7. Symbols and Functional Features ...................................................................14 8. Cleaning, maintenance, and disposal..............................................................17 9. Technical data .................................................................................................18 10. Regulatory .....................................................................................................19 F.03D.601.424 Rev. A 12/2012 | Robert Bosch Healthcare Systems, Inc. en 1. Introduction The Blood Pressure Monitor BP5000 BT is a device that you will use to measure your blood pressure and report the results to your care provider. The blood pressure monitor BP5000 BT connects wirelessly to your Bosch telehealth appliance, such as the Health Buddy or the T400. Read the entire instruction manual before you use your blood pressure monitor. If you have questions about your blood pressure monitor that are not answered by this manual, contact your care provider. If you have suggestions or feedback on this manual, you can send an email to [email protected]. Refer to document number F.03D.601.425 Rev. A in your email. A response will be provided only if you request one. Robert Bosch Healthcare Systems, Inc. | F.03D.601.424 Rev. A 12/2012 1 | en This device is intended for use on adults aged 18-years and older. 2. List of parts Ensure that your Bosch blood pressure monitor package includes the following items: Keep the plastic packaging, the batteries, and the thin plastic film protecting the screen of the blood pressure monitor away from babies and children — they are a choking hazard. Bosch BP5000 BT Blood Pressure Monitor 120 80 72 SYS mmHg EC DIA mmHg PUL /min 120 80 72 Four AA Batteries Arm Cuff F.03D.601.424 Rev. A 12/2012 | Robert Bosch Healthcare Systems, Inc. en | 2 3. Overview of symbols and functional features Your BP5000 BT blood pressure monitor has a number of symbols and features. 120 80 72 SYS mmHg EC DIA mmHg PUL /min Battery Volume Memory Appears when your previous blood pressure measurements are displayed. Bluetooth Appears when the blood pressure monitor is connected to your telehealth appliance. Pulse Blinks when your pulse is being measured. Start/Stop button Robert Bosch Healthcare Systems, Inc. | F.03D.601.424 Rev. A 12/2012 3 | en Memory button Volume button Press to see and hear your last blood pressure measurement. *Do not press the Bluetooth or Reset buttons unless you are asked to do so by your care provider. For a complete explanation of the symbols and functional features of your blood pressure monitor, see Section 7. Bluetooth On / Off* Language button By default, your blood pressure monitor is set to English. Reset button* Bluetooth pairing mode* Battery ribbon Use to remove batteries F.03D.601.424 Rev. A 12/2012 | Robert Bosch Healthcare Systems, Inc. en | 4 4. Setting up your blood pressure monitor Before you use your blood pressure monitor, you need to install the batteries and connect the arm cuff to the blood pressure monitor. Next, you need to set up the wireless connection between your blood pressure monitor and your Bosch telehealth appliance. 4.1 Installing the batteries To install the batteries: 1. Open the battery compartment cover on the bottom of the blood pressure monitor. 2. Insert the batteries (over the battery ribbon) as indicated by the diagram inside the battery compartment. 3. If your language is not English, select your language by pressing the language button. Language button Robert Bosch Healthcare Systems, Inc. | F.03D.601.424 Rev. A 12/2012 5 | en 4. Replace the battery compartment cover. 4.2 Connecting the arm cuff to your blood pressure monitor To connect the arm cuff to your blood pressure monitor, plug the air hose into the air socket on the side of the blood pressure monitor. When you replace the batteries, ensure that you replace the complete set of batteries and that you do not use rechargeable batteries, or the battery fluid might leak. F.03D.601.424 Rev. A 12/2012 | Robert Bosch Healthcare Systems, Inc. en | 6 not use in combination with magnetic resonance imaging (MRI) . equipment. If MRI is to be performed, remove cuff connected to the unit from the patient 4.3 Setting up the wireless connection To set up the wireless connection between your blood pressure monitor and your Bosch telehealth appliance: 1. Place your blood pressure monitor near your telehealth appliance to ensure a strong wireless connection. 2. If your care provider has provided you with a Bluetooth USB adapter, plug the Bluetooth USB adapter into any available USB port on the back of your telehealth appliance. If the Bluetooth USB adapter does not fit easily into the port, turn it over and try again. If your care provider did not provide you with a Bluetooth USB adapter, your telehealth appliance does not require one. Your blood pressure monitor is now ready…

Text truncated - open the document above for the full version.

Cover Letter(s)

AGENCY AUTHORIZATION LETTER FCC ID: NMTBP5000BT Date: Dec.19,2012 To whom it may concern: We, the undersigned, hereby authorize Shenzhen Huatongwei International Co.,Ltd of China to act on our behalf, as our agent in the following matters related to the FCC approval of our products: report submittal, related correspondence, the signing of all documents relating to these matters, and any other lawful activity necessary to obtain such certification, Any act carried out by Shenzhen Huatongwei International Co.,Ltd. within the scope of this authorization shall have the same effects as our own. This authorization shall expire 6 months from original date. If you have any questions regarding the authorization, please don’t hesitate to contact us. Sincerely, (签名人英文名): Alex (签名人职称): Project Manager IDT Technology Limited Tel: (86)755-29701028 Fax: (86)755-29799021 Web site:www.oregonscientific.com E-mail: [email protected]

Cover Letter(s)

Federal Communications Commission Authorization and Evaluation Division Date: Dec.19,2012 Confidentiality Request regarding application for certification of FCC ID: NMTBP5000BT Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: 1.Schematic 2.Theory of Operation 3.Block Diagram The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, We do not want these documents to be accessible to the general public. Sincerely, (签名人英文名): Alex (签名人职称): Project Manager IDT Technology Limited Tel: (86)755-29701028 Fax: (86)755-29799021 Web site: www.oregonscientific.com E-mail: [email protected]

External Photos

External Photos

Internal Photos

Internal Photos

RF Exposure Info

MPE TEST REPORT FCC Per 47 CFR 2.1091(b) & RSS-102 Report Reference No. .................... : FCC ID . ........................................... : IC . ................................................... : TRE1211005502 R/C:55325 NMTBP5000BT 3277A-BP5000BT Compiled by ( position+printed name+signature) .. : File administrators Eric Zhang Supervised by ( position+printed name+signature) .. : Test Engineer Tim Zhang Approved by ( position+printed name+signature) .. : Manager Wenliang Li Date of issue ..................................... : Dec 19, 2012 Testing Laboratory Name .............. : Shenzhen Huatongwei International Inspection Co., Ltd Address ............................................. : Keji Nan No.12 Road, Hi-tech Park, Shenzhen, China Applicant’s name ............................ : IDT TECHNOLOGY LIMITED Address ............................................. : 9/F, Phase I, Kaiser Estate, 41 Man Yue Street, Hunghom, Kowloon, Hong Kong. Test specification: Standard ........................................... : FCC Per 47 CFR 2.1091(b) & RSS-102 TRF Originator .................................. : Shenzhen Huatongwei International Inspection CO., Ltd Master TRF ....................................... : Dated 2006-06 Shenzhen Huatongwei International Inspection Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen Huatongwei International Inspection Co., Ltd is acknowledged as copyright owner and source of the material. Shenzhen Huatongwei International Inspection Co., Ltd takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description .................... : Bosch Bluetooth blood pressure monitor Trade Mark ....................................... : / Model/Type reference ....................... : BP5000 BT Modulation ........................................ : GFSK Listed Models .................................. : / Result ................................................ : Positive Report No.: TRE1211005502 Page 2 of 8 Issued:2012-12-19 T E S T R E P O R T Test Report No. : TRE1211005502 Dec 19, 2012 ______________________________________________________________________________________________ Date of issue Equipment under Test : Bosch Bluetooth blood pressure monitor Model /Type : BP5000 BT Listed Models : / Applicant : IDT TECHNOLOGY LIMITED Address : 9/F, Phase I, Kaiser Estate, 41 Man Yue Street, Hunghom, Kowloon, Hong Kong. Manufacturer : IDT TECHNOLOGY LIMITED Address : Chentian Industial Estate, Xixiang, Bao An,Shenzhen, PRC China The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: TRE1211005502 Page 3 of 8 Issued:2012-12-19 Contents 1. SUMMARY ............................................................................. 4 1.1. EUT configuration 4 1.2. Power supply system utilised 4 1.3. Description of the test mode 4 1.4. Related Submittal(s) / Grant (s) 4 1.5. Modifications 4 1.6. NOTE 5 2. TEST ENVIRONMENT ............................................................... 6 2.1. Address of the test laboratory 6 2.2. Environmental conditions 6 2.3. Statement of the measurement uncertainty 6 3. METHOD OF MEASUREMENT .................................................... 7 3.1. Applicable Standard 7 3.2. Limit 7 3.3. MPE Calculation Method 7 4. CONCLUSION ........................................................................ 8 Report No.: TRE1211005502 Page 4 of 8 Issued:2012-12-19 1. SUMMARY 1.1. EUT configuration The following peripheral devices and interface cables were connected during the measurement: ● - supplied by the manufacturer ○ - supplied by the lab ○ Power Cable Length (m) : / Shield : / Detachable : / ○ Multimeter Manufacturer : / Model No. : / 1.2. Power supply system utilised Power supply voltage : ○ 120V / 60 Hz ○ 115V / 60Hz ○ 12 V DC ○ 24 V DC ● Other (specified in blank below) DC 6.0V from battery 1.3. Description of the test mode The EUT has been tested under typical operating condition. There is BDR (Basic Data Rate) mode.The Applicant provides communication tools software to control the EUT for staying in continous transmitting and receiving mode for testing. There are 79 channels of EUT, and the test carried out at the lowest channel, middle channel and highest channel . Frequency Range: 2400-2483.5MHz Channel number: 79 channels Modulation type: Frequency Hopping Spread Spectrum Antenna: SMD Antenna 1.4. Related Submittal(s) / Grant (s) This submittal(s) (test report) is intended for FCC ID: NMTBP5000BT filing to comply with Section 15.247 of the FCC Part 15, Subpart C Rules and IC: 3277A-BP5000BT filing to comply with RSS-210. 1.5. Modifications No modifications were implemented to meet testing criteria. Report No.: TRE1211005502 Page 5 of 8 Issued:2012-12-19 1.6. NOTE 1. The functions of the EUT are listed as below: Test Standards Reference Report Radio FCC Part 15 Subpart C (Section15.247)& RSS-210 TRE1211005501 MPE FCC OET 65 C & RSS-102 TRE1211005502 2. The frequency bands used in this EUT are listed as follows: Frequency Band(MHz) 2400-2483.5 5150-5350 5470-5725 5725-5850 EUT √ - - - Report No.: TRE1211005502 Page 6 of 8 Issued:2012-12-19 2. TEST ENVIRONMENT 2.1. Address of the test laboratory Shenzhen Huatongwei International Inspection Co., Ltd Keji Nan No.12 Road, Hi-tech Park, Shenzhen, China Phone: 86-755-26715686 Fax: 86-755-26748089 The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.4 (2009) and CISPR Publication 22. 2.2. Environmental conditions During the measurement the environmental conditions were within the listed ranges: Temperature: 15-35 ° C Humidity: 30-60 % Atmospheric pressure: 950-1050mbar 2.3. Statement of the measurement uncertainty The data and …

Text truncated - open the document above for the full version.

Test Report

FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 & IC TEST REPORT RSS-210 Report Reference No. .....................: FCC ID . ............................................: IC . ....................................................: TRE1211005501 R/C:55325 NMTBP5000BT 3277A-BP5000BT Compiled by ( position+printed name+signature) .. : File administrators Eric Zhang Supervised by ( position+printed name+signature) .. : Test Engineer Tim Zhang Approved by ( position+printed name+signature) .. : Manager Wenliang Li Date of issue ..................................... : Dec 19, 2012 Testing Laboratory Name .............. : Shenzhen Huatongwei International Inspection Co., Ltd Address ............................................ : Keji Nan No.12 Road, Hi-tech Park, Shenzhen, China Applicant’s name ............................ : IDT TECHNOLOGY LIMITED Address ............................................ : 9/F, Phase I, Kaiser Estate, 41 Man Yue Street, Hunghom, Kowloon, Hong Kong. Test specification: Standard ........................................... : FCC Part 15.247: Operation within the bands 902-928 MHz, 2400-2483.5 MHz and 5725-5850 MHz Direct Sequence System IC RSS-210 IC RSS-Gen issue 3 TRF Originator .................................. : Shenzhen Huatongwei International Inspection CO., Ltd Master TRF ....................................... : Dated 2006-06 Shenzhen Huatongwei International Inspection Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen Huatongwei International Inspection Co., Ltd is acknowledged as copyright owner and source of the material. Shenzhen Huatongwei International Inspection Co., Ltd takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ........................ : Bosch Bluetooth blood pressure monitor Trade Mark ....................................... : / Model/Type reference ....................... : BP5000 BT Modulation ........................................ : GFSK Listed Models .................................. : / Result................................................ : Positive Report No.: TRE1211005501 Page 2 of 45 Issue Data:2012-12-19 T E S T R E P O R T Test Report No. : TRE1211005501 Dec 19, 2012 ______________________________________________________________________________________________ Date of issue Equipment under Test : Bosch Bluetooth blood pressure monitor Model /Type : BP5000 BT Listed Models : / Applicant : IDT TECHNOLOGY LIMITED Address : 9/F, Phase I, Kaiser Estate, 41 Man Yue Street, Hunghom, Kowloon, Hong Kong. Manufacturer : IDT TECHNOLOGY LIMITED Address : Chentian Industial Estate, Xixiang, Bao An,Shenzhen, PRC China Test Result according to the standards on page 7: Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: TRE1211005501 Page 3 of 45 Issue Data:2012-12-19 Contents 1. TEST STANDARDS .................................................................. 4 2. SUMMARY ............................................................................. 5 2.1. General Remarks 5 2.2. Equipment Under Test 5 2.3. Short description of the Equipment under Test (EUT) 5 2.4. EUT operation mode 5 2.5. Configuration of Test System 6 2.6. Related Submittal(s) / Grant (s) 6 2.7. Modifications 6 2.8. NOTE 6 3. TEST ENVIRONMENT ............................................................... 7 3.1. Address of the test laboratory 7 3.2. Test Facility 7 3.3. Environmental conditions 8 3.4. Test Description 8 3.5. Statement of the measurement uncertainty 8 3.6. Equipments Used during the Test 9 4. TEST CONDITIONS AND RESULTS ............................................ 10 4.1. AC Power Conducted Emission(Not Applicable) 10 4.2. Radiated Emission 11 4.3. Maximum Peak Output Power 18 4.4. 20dB Bandwidth 21 4.5. Band Edge 23 4.6. Frequency Separation 25 4.7. Number of hopping frequency 27 4.8. Time Of Occupancy(Dwell Time) 28 4.9. Receiver spurious Emissions(Not For FCC Review) 34 4.10. Antenna Requirement 39 5. TEST SETUP PHOTOS OF THE EUT .......................................... 40 6. EXTERNAL AND INTERNAL PHOTOS OF THE EUT ....................... 42 Report No.: TRE1211005501 Page 4 of 45 Issue Data:2012-12-19 1. TEST STANDARDS The tests were performed according to following standards: FCC Rules Part 15.247 : Frequency Hopping, Direct Spread Spectrum and Hybrid Systems that are in operation within the bands of 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz. ANSI C63.10-2009 : American National Standard for Testing Unlicensed Wireless Devices RSS-210 Issue 8 December 2010 : Licence-exempt Radio Apparatus (All Frequency Bands): Category I Equipment RSS-Gen Issue 3 December 2010 :General Requirements and Information for the Certification of Radio Apparatus Report No.: TRE1211005501 Page 5 of 45 Issue Data:2012-12-19 2. SUMMARY 2.1. General Remarks Date of receipt of test sample : Nov 25,2012 Testing commenced on : Nov 25,2012 Testing concluded on : Dec 19, 2012 2.2. Equipment Under Test Power supply system utilised Power supply voltage : ○ 120V / 60 Hz ○ 115V / 60Hz ○ 12 V DC ○ 24 V DC ● Other (specified in blank below) DC 6.0V from battery 2.3. Short description of the Equipment under Test (EUT) 2.4GHz (Bosch Bluetooth blood pressure monitor (BP5000 BT)), For more details, refer to the user’s manual of the EUT. Serial number: Prototype 2.4. EUT operation mode The EUT has been tested under typical operating condition. There is BDR (Basic Data Rate) mode.The Applicant provides communication tools software to control the EUT for staying in continous transmitting and receiving mode for testing. There are 79 channels of EUT, and the test carried out at the lowest channel, middle channel and highest ch…

Text truncated - open the document above for the full version.

Test Setup Photos

Test photos

Contact Information

Applicant

Alex Chan(Project Manager)
[email protected](86)755-29701028Fax: (86)755-29799021

Test Firm

Shenzhen Huatongwei International Insp. Co., LtdMoffy Yu
[email protected]86-755-26748078Fax: 86-755-26748089

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz105.40 mW
Confidentiality
Long Term
Grant Notes
Power output listed is peak conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC accepted multi-transmitter procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from IDT Technology Limited

Weather+BLE Connected Weather Station - FCC ID NMTBAR228-01 - IDT Technology Limited
NMTBAR228-01

Weather+BLE Connected Weather Station

Dec 03, 2015

Equipment Class

DTS - Digital Transmission System
Outdoor sensor - FCC ID NMTRTGN130A-01 - IDT Technology Limited
NMTRTGN130A-01

Outdoor sensor

Sep 10, 2015

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Activity Tracker - FCC ID NMTPE961 - IDT Technology Limited
NMTPE961

Activity Tracker

Nov 11, 2014

Equipment Class

DTS - Digital Transmission System
5 Channel Remote RCC-Thermo Sensor - FCC ID NMTRTHN129-01 - IDT Technology Limited
NMTRTHN129-01

5 Channel Remote RCC-Thermo Sensor

Sep 12, 2014

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
2nd generation activity and sleep monitor wrist device - FCC ID NMTPE289 - IDT Technology Limited
NMTPE289

2nd generation activity and sleep monitor wrist device

Aug 21, 2014

Equipment Class

DTS - Digital Transmission System