NMTTHGR122NX-01Remote Thermo Hygro Sensor

IDT Technology Limited
Remote Thermo Hygro Sensor - FCC ID NMTTHGR122NX-01 - IDT Technology Limited
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
May 05, 2004
Application Purpose
Original Equipment
Date of Application
May 05, 2004
Equipment Note
Remote Thermo Hygro Sensor
Frequency Range
433.96000000 - 433.96000000
Company
IDT Technology Limited
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

Schematics

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Wireless Acyrlic Thermo-Hygrometer & Atomic Alarm Clock Model : RMR613HGA User Manual RMR613HGA lab test cover R32/10/04, 3:38 PM1 EN 1 CONTENTS Contents ................................................................... 1 Introduction .............................................................. 2 About Oregon Scientific .......................................... 2 Product Overview .................................................... 3 Front View.............................................................. 3 Back View .............................................................. 4 Remote Sensor (THGR122NX) ............................. 5 Getting Started ......................................................... 6 Batteries................................................................. 6 Change Settings .................................................... 6 Table Stand ............................................................ 6 Remote Sensor (THGR122NX) ................................ 6 Setup Sensor ......................................................... 6 Data Transmission ................................................. 7 Search for Sensor .................................................. 8 Clock ......................................................................... 8 Turn Atomic Clock ON/OFF ................................... 9 Set Clock ............................................................... 9 Switch Clock Display ............................................. 9 Alarms ....................................................................... 9 View Alarm Settings ............................................... 9 Set Alarm ............................................................... 9 Activate Alarm ...................................................... 10 Silence Alarm ....................................................... 10 Temperature and Humidity .................................... 10 Select Temperature Unit ...................................... 10 Select Sensor Channel ........................................ 10 Minimum / Maximum Records ............................. 11 Comfort Zone ....................................................... 11 Reset System ......................................................... 11 Safety and Care ...................................................... 12 Warnings ................................................................. 12 Troubleshooting ..................................................... 12 Specifications ......................................................... 13 Main Unit Dimensions .......................................... 13 Remote Sensor Dimensions ................................ 13 Temperature......................................................... 13 Relative Humidity ................................................. 13 Remote Sensor (THGR122NX) ........................... 13 Clock .................................................................... 13 Power................................................................... 14 FCC Statement ....................................................... 14 RMR613HGA lab test R32/18/04, 2:22 PM1 EN 2 INTRODUCTION Thank you for selecting the Oregon Scientific TM Wireless Acyrlic Thermo-Hygrometer & Atomic Alarm Clock (RMR613HGA). This device bundles precise time keeping, dual alarm, and temperature and humidity monitoring features into a single tool you can use from the convenience of your home. In this box, you will find: •Main unit •Remote sensor (THGR122NX) Keep this manual handy as you use your new product. It contains practical step-by-step instructions, as well as technical specifications and warnings you should know. ABOUT OREGON SCIENTIFIC Visit our website (www.oregonscientific.com) to learn more about other Oregon Scientific products such as digital cameras, hand-held organizers, health and fitness gear, and projection clocks. The website also includes contact information for our customer service department, in case you need to reach us. RMR613HGA lab test R32/18/04, 2:22 PM2 EN 3 PRODUCT OVERVIEW FRONT VIEW 1.Clock / Alarm Area: Date, time, dual alarm; and Atomic Clock reception status 2.Temperature Area: Readings; sensor channel number; remote unit reception and battery status 3.Humidity / Comfort Zone Area: Readings, comfort zone and battery status. 4.Channel button: switch remote sensor 5.Alarm button: view alarm status; set alarm 1 2 3 45 RMR613HGA lab test R32/18/04, 2:22 PM3 EN 4 BACK VIEW 1.MEM: view current, maximum, and minimum temperature / humidity readings 2.DOWN: decrease setting / deactivate radio- controlled clock / activate or deactivate alarm 3.UP: increase setting / activate radio-controlled clock / activate or deactivate alarm 4.MODE: change display / settings 5.Battery compartment 6.°C / °F switch 7.RESET hole 3 4 1 2 5, 6, 7 RMR613HGA lab test R32/18/04, 2:22 PM4 EN 5 REMOTE SENSOR (THGR122NX) 1. LCD display 2. LED Status indicator 1 2 1 2 3 4 1. Wall mount hole 2.RESET 3. Channel number (1 - 3) 4. Battery compartment (Battery compartment cover not shown) RMR613HGA lab test R32/18/04, 2:22 PM5 EN 6 CHANGE SETTINGS 1.Press and hold MODE for 2 seconds to enter setting mode. 2. Press UP or DOWN to change settings. 3. Press MODE to confirm. REMOTE SENSOR (THGR122NX) This product is shipped with a THGR122NX Thermo/ Hygro Sensor that collects Temperature and Humidity data. Data can be collected from up to 3 sensors. Additional sensors sold separately. SETUP SENSOR Open the remote sensor battery compartment with a small Phillips screwdriver. GETTING STARTED BATTERIES Batteries are not supplied with this product. You will need to purchase 2 x UM-3 (AA) 1.5V alkaline batteries for the main unit, and 2 x UM-4 (AAA) 1.5V alkaline batteries for the remote sensor. Insert the batteries before first use, matching the polarity as shown in the battery compartment. For best results, install batteries in the remote sensor before the main unit. …

Text truncated - open the document above for the full version.

External Photos

INTERTEK TESTING SERVICES FCC ID: NMTHGR122NX-01 External Photo Front View Rear View

Internal Photos

INTERTEK TESTING SERVICES FCC ID: NMTHGR122NX-01 Internal Photo Photo-1 Photo-2 INTERTEK TESTING SERVICES FCC ID: NMTHGR122NX-01 Internal Photo Photo-3 Photo-4 INTERTEK TESTING SERVICES FCC ID: NMTHGR122NX-01 Internal Photo Photo-5

Operational Description

IDT Technology Limited F A C S I M I L E C O M M U N I C A T I O N 9/F Kaiser Estate, 41 Man Yue Street, Hunghom, Kowloon, Hong Kong. Tel 2764 7873 Fax 2765 6620 Cable IDTRAYMOND Telex 36567-IDTHK HX Technical description of THGR122NX THGR198N is a transmitter, which it operated at 433.96MHz at the center frequency with integral antenna. The EUT powered by 3V DC ( 2 X UM4 or “AAA” size 1.5V batteries ).When the batteries supplied to the unit, the MCU (U1) start to collect all relative data from the sensing devices, (eg TEMP, Humidity, Channel and C/F setting ). After the conversion by MCU U1, all data have be converted to serial signal. The signal should be in OOK format. Transmiter The X2 as the SAW filter, it used to control the OSC frequency and turned at 433.96MHz , the OOK signal have be amplified by Q10 and radiated from interal antenna. Miscellaneous The U1 MCU used as the encoder function, which it converted the TEMP & Humidity value into the OOK singal, The 32.768KHz as the main clock of MCU.

Test Report

• The test results reported in this test report shall refer only to the sample actually tested and shall not refer or be deemed to refer to bulk from which such a sample may be said to have been obtained. • This report shall not be reproduced except in full without prior authorization from Intertek Testing Services Hong Kong Limited. • For Terms And Conditions of the services, it can be provided upon request. • The evaluation data of the report will be kept for 3 years from the date of issuance. Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2371 0521 Website: www.hk.intertek-etlsemko.com IDT Technology Limited Application For Certification (FCC ID: NMTTHGR122NX-01) Transmitter 0320135 DL/ Sandy March 8, 2004 INTERTEK TESTING SERVICES FCC ID: NMTTHGR122NX-01 i LIST OF EXHIBITS INTRODUCTION EXHIBIT 1: General Description EXHIBIT 2: System Test Configuration EXHIBIT 3: Emission Results EXHIBIT 4: Equipment Photographs EXHIBIT 5: Product Labelling EXHIBIT 6: Technical Specifications EXHIBIT 7: Instruction Manual EXHIBIT 8: Miscellaneous Information INTERTEK TESTING SERVICES FCC ID: NMTTHGR122NX-01 ii MEASUREMENT/TECHNICAL REPORT IDT Technology Limited - MODEL: Remote Thermo Hygro Sensor THGR122NX FCC ID: NMTTHGR122NX-01 March 8, 2004 This report concerns (check one:) Original Grant X Class II Change Equipment Type: Low Power Transmitter (example: computer, printer, modem, etc.) Deferred grant requested per 47 CFR 0.457(d)(1)(ii)? Yes No X If yes, defer until: date Company Name agrees to notify the Commission by: date of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37? Yes No X If no, assumed Part 15, Subpart C for intentional radiator - the new 47 CFR [03-13-03 Edition] provision. Report prepared by: Derek Leung Intertek Testing Services 2/F., Garment Center, 576, Castle Peak Road, HONG KONG. Phone: 852-2173-8504 Fax: 852-2371-0521 INTERTEK TESTING SERVICES FCC ID: NMTTHGR122NX-01 iii Table of Contents 1.0 General Description............................................................................................ 2 1.1 Product Description ............................................................................................ 2 1.2 Related Submittal(s) Grants ............................................................................... 2 1.3 Test Methodology............................................................................................... 3 1.4 Test Facility........................................................................................................ 3 2.0 System Test Configuration ................................................................................. 5 2.1 Justification ........................................................................................................ 5 2.2 EUT Exercising Software.................................................................................... 5 2.3 Special Accessories ........................................................................................... 5 2.4 Equipment Modification ...................................................................................... 6 2.5 Measurement Uncertainty .................................................................................. 6 2.6 Support Equipment List and Description ............................................................. 6 3.0 Emission Results ................................................................................................ 8 3.1 Field Strength Calculation................................................................................... 9 3.2 Radiated Emission Configuration Photograph................................................... 11 3.3 Radiated Emission Data ................................................................................... 12 4.0 Equipment Photographs ................................................................................... 15 5.0 Product Labelling.............................................................................................. 17 6.0 Technical Specifications................................................................................... 19 7.0 Instruction Manual ............................................................................................ 21 8.0 Miscellaneous Information ............................................................................... 23 8.1 Measured Bandwidth........................................................................................ 24 8.2 Discussion of Pulse Desensitization.................................................................. 25 8.3 Calculation of Average Factor........................................................................... 26 8.4 Emissions Test Procedures .............................................................................. 27 INTERTEK TESTING SERVICES FCC ID: NMTTHGR122NX-01 iv List of attached file Exhibit type File Description filename Test Report Test Report report.pdf Operation Description Technical Description descri.pdf Test Setup Photo Radiated Emission radiated photos.pdf Test Report Bandwidth Plot bw.pdf External Photo External Photo external photos.pdf Internal Photo Internal Photo internal photos.pdf Block Diagram Block Diagram block.pdf Schematics Circuit Diagram circuit.pdf ID Label/Location Label Artwork and Location label.pdf User Manual User Manual manual.pdf Test Report Timing Diagram timing.pdf INTERTEK TESTING SERVICES FCC ID: NMTTHGR122NX-01 1 EXHIBIT 1 GENERAL DESCRIPTION INTERTEK TESTING SERVICES FCC ID: NMTTHGR122NX-01 2 1.0 General Description 1.1 Product Description The Equipment Under Test (EUT) is a transmitter operating at 433.96MHz. The EUT is powered by 3.0V d.c. (2 x “AAA” size batteries). During normal use, it transmits temperature signal to the corresponding receiver. The temperature will be …

Text truncated - open the document above for the full version.

Test Setup Photos

INTERTEK TESTING SERVICES FCC ID: NMTHGR122NX-01 Radiated Emissions Test Setup Front View Rear View

Contact Information

Applicant

Alex Chan(Project Manager)
[email protected](86)755-29701028Fax: (86)755-29799021

Technical Contact

Intertek Testing Services Hong Kong Ltd.Derek Leung
[email protected]852-2173-8539

2/F., Garment Centre, · Kowloon · Hong Kong

Non-Technical Contact

Intertek Testing Services Hong Kong Ltd.Derek Leung
[email protected]852-2173-8539

Test Firm

Intertek Testing Services Hong KongC. Yuen
[email protected]852-2173-8565Fax: 852-2742-5716

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231(e)433.96 MHz - 433.96 MHz-

Other Applications from IDT Technology Limited

Weather+BLE Connected Weather Station - FCC ID NMTBAR228-01 - IDT Technology Limited
NMTBAR228-01

Weather+BLE Connected Weather Station

Dec 03, 2015

Equipment Class

DTS - Digital Transmission System
Outdoor sensor - FCC ID NMTRTGN130A-01 - IDT Technology Limited
NMTRTGN130A-01

Outdoor sensor

Sep 10, 2015

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Activity Tracker - FCC ID NMTPE961 - IDT Technology Limited
NMTPE961

Activity Tracker

Nov 11, 2014

Equipment Class

DTS - Digital Transmission System
5 Channel Remote RCC-Thermo Sensor - FCC ID NMTRTHN129-01 - IDT Technology Limited
NMTRTHN129-01

5 Channel Remote RCC-Thermo Sensor

Sep 12, 2014

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
2nd generation activity and sleep monitor wrist device - FCC ID NMTPE289 - IDT Technology Limited
NMTPE289

2nd generation activity and sleep monitor wrist device

Aug 21, 2014

Equipment Class

DTS - Digital Transmission System