Equipment Class
AMP - Amplifier
Date of Grant
Feb 06, 2000
Application Purpose
Original Equipment
Date of Application
Oct 26, 1999
Equipment Note
Cellular Repeater
Frequency Range
824.00000000 - 849.00000000
Company
EMS Technologies Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗

External Photos

↗
↗
↗
↗

ID Label/Location Info

↗

Internal Photos

↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗

Operational Description

↗

Test Report

↗

Test Setup Photos

↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Operator's Manual MirrorCell  Select CDMA Repeater Model CDR812 Model CDR801 1211 Ira E. Woods avenue Grapevine, TX 76051 (817) 416-0583 Fax: (817) 488-1949 Introduction CI Wireless Inc. MirrorCell Select CDR812 Manual iiRev. X1 File: \CDR812X1.DOC Rev. X1 07 SEPT 1999 CI Wireless Inc.Introduction MirrorCell Select CDR812 Manual Rev. X1iii Disclaimer Every attempt has been made to make this material complete, accurate, and up-to-date. Users are cautioned, however, that CI Wireless Inc. reserves the right to make changes without notice and shall not be responsible for any damages, including consequential, caused by reliance on the material presented, including, but not limited to, typographical, arithmetical, or listing errors. Copyright Information © 1999 by CI Wireless Inc. CI Wireless Inc. Grapevine, TX 76051 Introduction CI Wireless Inc. MirrorCell Select CDR812 Manual ivRev. X1 WARNINGS, CAUTIONS, AND GENERAL NOTES This product conforms to FCC Part 15, Section 21. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense. Safety Considerations When installing or using this product, observe all safety precautions during handling and operation. Failure to comply with the following general safety precautions and with specific precautions described elsewhere in this manual violates the safety standards of the design, manufacture, and intended use of this product. CI Wireless Inc. assumes no liability for the customer's failure to comply with these precautions. WARNING WARNING Calls attention to a procedure or practice which, if ignored, may result in damage to the system or system component. Do not perform any procedure preceded by a WARNING until described conditions are fully understood and met. If You Need Help If you need additional copies of this manual, or have questions about system options, or need help with installation and using of the system, please contact CI Wireless’ Sales Department. CI Wireless Sales Dept. 1211 Ira E. Woods Ave. Grapevine, TX 76051 USA (817) 416-0583 CI Wireless Inc.Introduction MirrorCell Select CDR812 Manual Rev. X1v Service Do not attempt to modify or service any part of this product other than in accordance with procedures outlined in this Operator's Manual. If the product does not meet its warranted specifications, or if a problem is encountered that requires service, notify CI Wireless’ sales department. Service will be rendered according the CI Wireless’ warranty and repair policy. The product shall not be returned without contacting CI wireless and obtaining a return authorization number from the Sales department When returning a product for service, include the following information: Owner, Model Number, Serial Number, Return Authorization Number (obtained in advance from CI Wireless Customer Service Department), service required and/or a description of the problem encountered. Warranty and Repair Policy The CI Wireless Quality Plan includes product test and inspection operations to verify the quality and reliability of our products. CI Wireless uses every reasonable precaution to ensure that every device meets published electrical, optical, and mechanical specifications prior to shipment. Customers are asked to advise their incoming inspection, assembly, and test personnel as to the precautions required in handling and testing ESD sensitive opto-electronic components. Physical damage to the external surfaces voids warranty. These products are covered by the following warranties: 1.General Warranty CI Wireless warrants to the original purchaser all standard products sold by CI Wireless to be free of defects in material and workmanship for the duration of the warranty period of one (1) year from date of shipment from CI Wireless. During the warranty period, CI Wireless’ obligation, at our option, is limited to repair or replacement of any product that CI Wireless proves to be defective. This warranty does not apply to any product which has been subject to alteration, abuse, improper installation or application, accident, electrical or environmental over-stress, negligence in use, storage, transportation or handling. 2.Specific Product Warranty Instructions All CI Wireless products are manufactured to high quality standards and are warranted against defects in workmanship, materials and construction, and to no further extent. Any claim for repair or replacement of a device found to be defective on incoming inspection by a customer must be made within 30 days of receipt of the shipment, or within 30 days of discovery of a defect within the warranty period. This warranty is the only warranty made by CI Wireless and is in lieu of all other warranties, expressed or implied, except as to title, and can be amended only by a written instrument signed by an officer of CI Wireless. CI Wireless sales agents or representatives are not authorized to make commitments on warranty returns. In the event that it is necessary to return any product against the above warranty, the following procedure shall be followed: Introduction CI Wireless Inc. MirrorCell Select CDR812 Manual viRev. X1 a.Return authorization shall be received from the CI Wireless Customer Service prior to returning any device. Advise the CI Wireless Cust…

Text truncated - open the document above for the full version.

ID Label/Location Info

Professional Testing (EMI), Inc. Label and Label Location CI Wireless Inc. MirrorCell 800 MHz Cellular Band 8 Watt Repeater FCC ID: NUW008CMIR8 Professional Testing (EMI), Inc.

Operational Description

PS-XXXX Rev X1 Pg. 1 of 18 File: cdr-812 specs CI Wireless Inc. PRODUCT SPECIFICATION MirrorCell ® Cellular Band CDMA Channel Selective Repeater Model: CDR-812 Model: CDR-801 Written By: Leo Kha Date of Original Issue: Aug. 19, 1999 Date Revised: None Replaces Rev: None PS-XXXX Rev X1 Pg. 2 of 18 File: cdr-812 specs CONTENTS 1 INTRODUCTION ------------------------------------------------------------------------------------------------------------------------- [3] 1.1 Scope ------------------------------------------------------------------------------------------------------------------------------------- [3] 1.2 Related Document --------------------------------------------------------------------------------------------------------------------- [3] 2 SYSTEM DESCRIPTION --------------------------------------------------------------------------------------------------------------- [3] 2.1 General ------------------------------------------------------------------------------------------------------------------------------------ [3] 2.2 System Description --------------------------------------------------------------------------------------------------------------------- [4] 2.2.1 Model Numbers & Options --------------------------------------------------------------------------------------------------------- [4] 2.2.2 Part Numbers and Description ---------------------------------------------------------------------------------------------------- [4] 2.2.3 System Block Diagrams ------------------------------------------------------------------------------------------------------------- [5] 3 SPECIFICATIONS ------------------------------------------------------------------------------------------------------------------------ [6] 3.1 Electrical Requirement ----------------------------------------------------------------------------------------------------------------- [6] 3.1.1 Channel and Frequency Plan ------------------------------------------------------------------------------------------------------ [6] 3.1.2 Electrical Specifications ------------------------------------------------------------------------------------------------------------- [7] 3.2 Mechanical Requirement -------------------------------------------------------------------------------------------------------------- [8] 3.3 Interface Requirement ----------------------------------------------------------------------------------------------------------------- [8] 3.3.1 AC Power ------------------------------------------------------------------------------------------------------------------------------- [8] 3.3.2 DC Power ------------------------------------------------------------------------------------------------------------------------------- [8] 3.4 Environmental Requirement ---------------------------------------------------------------------------------------------------------- [8] 3.5 Certifications ------------------------------------------------------------------------------------------------------------------------------ [8] 4 STATUS & CONTROL ------------------------------------------------------------------------------------------------------------------- [9] 4.1 General ------------------------------------------------------------------------------------------------------------------------------------ [9] 4.2 Settings ------------------------------------------------------------------------------------------------------------------------------------ [9] 4.3 Login via Local Maintenance Terminal (LMT) ------------------------------------------------------------------------------------ [9] 4.4 Commands -------------------------------------------------------------------------------------------------------------------------------- [9] 4.5 Alarms & Controls ----------------------------------------------------------------------------------------------------------------------- [10] 4.6 Command Log --------------------------------------------------------------------------------------------------------------------------- [10] 4.7 Quick Commands ----------------------------------------------------------------------------------------------------------------------- [10] 4.8 External Alarms Configuration ------------------------------------------------------------------------------------------------------- [10] 4.9 LED Indicators ----------------------------------------------------------------------------------------------------------------------------[11] 4.10 Command Attributes -------------------------------------------------------------------------------------------------------------------- [11] 5 TEST DATA SHEET ---------------------------------------------------------------------------------------------------------------------- [15] 6 RELEASE AND REVISION RECORD ----------------------------------------------------------------------------------------------- [18] PS-XXXX Rev X1 Pg. 3 of 18 File: cdr-812 specs 1 INTRODUCTION 1.1 Scope This document establishes the electrical, mechanical, environmental and reliability specifications for the Cellular Band CDMA Channel Selective Repeater. 1.2 Related Document Acceptance Test Procedure ATP- Test Data Sheet TDS 2 SYSTEM DESCRIPTION 2.1 General The Channel Selective Repeater is used to extend the radio frequency (RF) coverage of the base station. The repeater is well suited for providing RF coverage into shopping centers, convention centers, tunnels, office buildings, and other areas where the signal blockage does not allow direct coverage from the base station. The repeater is designed for TIA/EIA/IS-95, titled “Mobile Station-Base Station Compatibility Standard for Dual- Mode Wideband Spread Spectrum Cellular System.” Operations, Administration and Maintenance (OA&M) functionality of the repeater provides the service provider with local as well as remote monitor, control, configure and maintain the system. The system is capable of providing over 10,000 user-defined address to…

Text truncated - open the document above for the full version.

Test Report

FCC ID# NUWØØ8CMIR8 FCC ID: NUWØØ8CMIR8 Prepared for: CI WIRELESS INC. 1211 Ira E. Woods Avenue Grapevine, Texas 76051 By: Professional Testing (EMI), Inc. 1601 FM 1460, Suite B Round Rock, Texas 78664 Submitted to: Federal Communications Commission Equipment Approval Services P.O. Box 358315 Pittsburgh, Pennsylvania 15251-3315 October 1999 FCC Application for Certification of an Intentional Radiator CI WIRELESS INC. MirrorCell 800 MHz Cellular Band 8 Watt Repeater (Transmitter Portion) FCC ID# NUWØØ8CMIR8 Professional Testing (EMI), Inc.2 of 39 Table of Contents Title Page ...............................................................................................................................................1 Table of Contents....................................................................................................................................2 Certificate of Compliance.......................................................................................................................3 1.0Equipment Under Test (EUT) Description...................................................................5 2.0Occupied Bandwidth Measurements.............................................................................6 2.1Test Procedure............................................................................................................6 2.2Test Criteria.................................................................................................................6 2.3Test Results.................................................................................................................6 3.0Effective Radiated Power (ERP) Measurements...........................................................7 3.1Test Procedure............................................................................................................7 3.2Test Criteria.................................................................................................................7 3.3Test Results.................................................................................................................8 4.0Out of Band Emissions - Radiated................................................................................8 4.1Test Procedure............................................................................................................8 4.2Test Criteria.................................................................................................................8 4.3Test Results.................................................................................................................9 5.0Out of Band Emissions - Conducted.............................................................................9 5.1Test Procedure............................................................................................................9 5.2Test Criteria.................................................................................................................9 5.3Test Results...............................................................................................................10 6.0Radiofrequency Radiation Exposure Evaluation.........................................................10 6.1Evaluation Procedure.................................................................................................10 6.2Evaluation Results.....................................................................................................10 7.0Three Signal Intermodulation Test.............................................................................11 8.0Form 731 Information..............................................................................................112 8.1Emission Designator..................................................................................................12 8.2Output Power............................................................................................................13 8.3 Output Power Ratings for Multi-Channel Operation...................................................13 8.4Frequency Band of Operation....................................................................................13 8.5Grant Notes...............................................................................................................14 9.0Modifications.............................................................................................................14 10.0List of Test Equipment...............................................................................................14 Appendices Appendix A - Occupied Bandwidth Test Data.....................................................................................15 Appendix B - Effective Radiated Power (ERP) Test Data...................................................................22 Appendix C - Out of Band Emissions - Radiated Test Data.................................................................24 Appendix D - Out of Band Emissions - Conducted Test Data..............................................................31 Appendix E – Intermodulation Product Data Sheets............................................................................35 FCC ID# NUWØØ8CMIR8 1601 FM 1460, Suite B Round Rock, Texas 78664 512/244-3371 Fax 512/244-1846 Applicant:CI Wireless Inc. Applicant’s Address:1211 Ira E. Woods Avenue Grapevine, Texas 76051 Model:MirrorCell 800 MHz Cellular Band 8 Watt Repeater Serial Number:EN101 Project Number:00219-10 Test Dates:September 29 and 30, 1999 I, Jeffrey A. Lenk, for Professional Testing (EMI), Inc., being familiar with the FCC rules and test procedures have reviewed the test setup, measurement data and this report. I believe them to be true and accurate. The CI Wireless Inc., MirrorCell 800 MHz Cellular Band 8 Watt Repeater was tested and found to be in compliance with FCC Part 22 for Intentional Radiators. _________________________ Jeffrey A. Lenk President Certificate of Compliance FCC ID# N…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Richard E Kent(Assistant General Counsel)
[email protected]973-455-4734Fax: 973-455-5904

Technical Contact

CI Wireless, Inc.David L Mckay
[email protected]817-416-0583

1121 Ira E. Woods Ave. · Grapevine, Texas · United States

Non-Technical Contact

CI Wireless, Inc.David L Mckay
[email protected]817-416-0583

Test Firm

Professional Testing (EMI) Inc.Jeffrey Lenk
[email protected]512-244-3371Fax: 512-244-1846

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
222.901(d)824 MHz - 849 MHz4 W1M36F9W%
Confidentiality
Long Term

Other Applications from EMS Technologies Inc

1900 MHz PCS Repeater - FCC ID NUW0A1MINI19 - EMS Technologies Inc
NUW0A1MINI19

1900 MHz PCS Repeater

Feb 13, 2000

Equipment Class

AMP - Amplifier
Cellular Repeater - FCC ID NUW050CEKO8 - EMS Technologies Inc
NUW050CEKO8

Cellular Repeater

Dec 09, 1999

Equipment Class

AMP - Amplifier
ESMR Antenna Extender - FCC ID NUW050SEKO8 - EMS Technologies Inc
NUW050SEKO8

ESMR Antenna Extender

Oct 04, 1999

Equipment Class

AMP - Amplifier
800 MHz ESMR Band EkoCell Repeater - FCC ID NUW004SEKO8 - EMS Technologies Inc
NUW004SEKO8

800 MHz ESMR Band EkoCell Repeater

Apr 25, 1999

Equipment Class

AMP - Amplifier
1900 MHz PCS Band 8 Watt Repeater - FCC ID NUW008EKO19 - EMS Technologies Inc
NUW008EKO19

1900 MHz PCS Band 8 Watt Repeater

Apr 25, 1999

Equipment Class

AMP - Amplifier