FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Identec Solutions, Inc./
  3. O2E-ILR-IP3NA

O2E-ILR-IP3NAi-Port3

Identec Solutions, Inc.
i-Port3 - FCC ID O2E-ILR-IP3NA - Identec Solutions, Inc.
Click to zoom

Application Details

Equipment Class
FDS - Part 15 Field Disturbance Sensor
Date of Grant
Jan 17, 2006
Application Purpose
Original Equipment
Date of Application
Nov 15, 2005
Equipment Note
i-Port3
Frequency Range
905.00000000 - 914.80000000
Company
Identec Solutions, Inc.
Country
Canada

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Parts List/Tune Up Info

↗

Test Report

↗

Test Setup Photos

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Rhein Tech Laboratories, Inc. Client: Identec Solutions, Inc. 360 Herndon Parkway Model: i-PORT 3 Suite 1400 Report No: 2005011 Herndon, VA 20170 Standards: FCC 15.245/IC RSS-210 http://www.rheintech.com Date: May 11, 2005 Page 36 of 48 APPENDIX H: MANUAL Please see the following pages. _______________________________________________________________________ Document #7201-001, Rev C Page 1 i-PORT3 User’s Guide IDENTEC SOLUTIONS, Inc. Suite 102, 1860 Dayton Street Kelowna, British Columbia Canada V1Y 7W6 Tel: (250) 860-6567 Fax: (250) 860-6541 www.identecsolutions.com ________________________________________________________________________ Document #7201-001, Rev C Page 2 Proprietary Notice This document contains confidential information proprietary to IDENTEC SOLUTIONS, Inc. and may not be used or disclosed to other parties in whole or in part without prior written authorization from IDENTEC SOLUTIONS, Inc. Disclaimer and Limitation of Liability IDENTEC SOLUTIONS, Inc. and its affiliates, subsidiaries, officers, directors, employees and agents provide the information contained in this Manual on an “as-is” basis and do not make any express or implied warranties or representations with respect to such information including, without limitation, warranties as to non-infringement, reliability, fitness for a particular purpose, usefulness, completeness, accuracy or currentness. IDENTEC SOLUTIONS, Inc. shall not in any circumstances be liable to any person for any special, incidental, indirect or consequential damages, including without limitation, damages resulting from use of or reliance on information presented herein, or loss of profits or revenues or costs of replacement goods, even if informed in advance of the possibility of such damages. Trademarks “IDENTEC SOLUTIONS”, “Intelligent Long Range”, “ILR” and the stylized “i” are registered trademarks and “i-Q”, “i-D”, “i-CARD”, “i-PORT”, “i-LINKS”, “Solutions. It’s in our name.” are trademarks of IDENTEC SOLUTIONS, Inc. and/or IDENTEC SOLUTIONS AG. Copyright Notice Copyright © 2002 IDENTEC SOLUTIONS, Inc. All rights reserved. No part of this document may be reproduced or transmitted in any form by any means, photographic, electronic, mechanical or otherwise, or used in any information storage and retrieval system, without the prior written permission of IDENTEC SOLUTIONS, Inc. ________________________________________________________________________ Document #7201-001, Rev C Page 3 Radio Frequency Compliance Statement IDENTEC SOLUTIONS, Inc. is the responsible party for the compliance of the following devices: MODEL: i-PORT 3 FCC ID: O2E-ILR-IPORT3 CANADA: Pending EUROPE: CE 0678(!) The user(s) of these products are cautioned to only use accessories and peripherals approved, in advance, by IDENTEC SOLUTIONS, Inc. The use of accessories and peripherals, other than those approved by IDENTEC SOLUTIONS, Inc., or unauthorized changes to approved products, may void the compliance of these products and may result in the loss of the user(s) authority to operate the equipment. Operation is subject to the following conditions: (1) these devices may not cause harmful interference, and (2) these devices must accept any interference, including interference that may cause undesired operation of the device. FCC Compliance This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communication. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his/her own expense. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Industry Canada Compliance This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (EIRP) is not more than that required for successful communication. Important Note To comply with FCC radio frequency exposure compliance requirements, this device must be installed by an IDENTEC SOLUTIONS certified technician. When installing antennas, a 20 centimeter passing distance must be maintained from any body part of the user or nearby persons and the antenna. The installer of this radio equipment must ensure that the antenna is located or pointed such that it does not emit RF field in excess of Health Canada limits for the general population; consult Safety Code 6, obtainable from Health Canada. ________________________________________________________________________ Document #7201-001, Rev C Page 4 Table of Contents 1.0 INTRODUCTION ...........................................................................................................................................5 1.1 FUNDAMENTALS.............................................................................................................................................5 1.2 SYSTEM OVERVIEW........................................................................................................................................5 2.0 COMPONENTS...............................................................................................................................................6 2.1 I-PORT3..........................................................…

Text truncated - open the document above for the full version.

Attestation Statements

Rhein Tech Laboratories, Inc. Client: Identec Solutions, Inc. 360 Herndon Parkway Model: i-PORT 3 Suite 1400 Report No: 2005011 Herndon, VA 20170 Standards: FCC 15.245/IC RSS-210 http://www.rheintech.com Date: May 11, 2005 Page 28 of 48 APPENDIX A: AGENCY AUTHORIZATION Please see the following page. www.identecsolutions.com 29 March 2005 American TCB, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 SUBJECT: Agent Authorization To Whom It May Concern: Please consider this letter as our authorization for Rhein Tech Laboratories, Inc. (RTL), 360 Herndon Parkway, Suite 1400, Herndon, VA 20170 to act as our agent in all matters relating to the Reference FCC applications submitted to American Telecommunications Certification Body, Inc. (ATCB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002(b), to the application is subject to denial of federal benefits, that includes FCC benefits. If you have any questions or concerns, please do not hesitate to contact me at (250) 860-6567. Yours truly, IDENTEC SOLUTIONS, INC. Marty Brooks Product Engineer Email: [email protected] IDENTEC SOLUTIONS, INC. Suite 102, 1860 Dayton Stree t Kelowna, British Columbia Canada V1Y 7W6 Tel: (250) 860-6567 Fax: (250) 860-6541

Cover Letter(s)

Rhein Tech Laboratories, Inc. Client: Identec Solutions, Inc. 360 Herndon Parkway Model: i-PORT 3 Suite 1400 Report No: 2005011 Herndon, VA 20170 Standards: FCC 15.245/IC RSS-210 http://www.rheintech.com Date: May 11, 2005 Page 29 of 48 APPENDIX B: CONFIDENTIALITY REQUEST Please see the following page. www.identecsolutions.com 24 May 2005 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 SUBJECT: Request For Confidentiality Reference A: FCC ID: O2E-ILR-IP3NA To Whom It May Concern: Further to the device approval identified at Reference A, IDENTEC SOLUTIONS hereby requests confidentiality pursuant to Section 0.459 of the Commission’s rules (CFR 47). IDENTEC SOLUTIONS requests that the following documents be withheld from public inspection: 1. Block Diagram/Theory of Operation 2. Circuit diagrams and descriptions 3. Schematics These exhibits contain IDENTEC SOLUTIONS’ proprietary information, trade secrets, or other confidential information that IDENTEC SOLUTIONS does not release to the public and which is otherwise not available to the general public. Since this design is a basis from which future technological products will evolve, IDENTEC SOLUTIONS considers that this information would be of benefit to its competitors, and that the disclosure of the information in these documents would give competitors an unfair advantage in the market. IDENTEC SOLUTIONS protects all of its proprietary, intellectual property rights and confidential information by requiring all of its employees and all other recipients of such information to sign confidentiality and non-disclosure agreements prior to receiving such information. If you have any questions or concerns, please do not hesitate to contact me at (250) 860-6567. Yours truly, IDENTEC SOLUTIONS, INC. Marty Brooks Director of Operations Email: [email protected] IDENTEC SOLUTIONS, INC. Suite 102, 1860 Dayton Street Kelowna, British Columbia Canada V1Y 7W6 Tel: (250) 860-6567 Fax: (250) 860-6541

Cover Letter(s)

Schwaninger & Associates, P.C. Attorneys at Law 1331 H Street, N.W., Suite 500, Washington, DC 20005 Internet Address – http://www.sa-lawyers.net telephone – (202) 347-8580 facsimile – (202) 347-8607 December 21, 2005 Federal Communications Commission 445 12th Street SW Washington, DC 20554 Re: Identec Solutions, Inc. 731 Confirmation Number: EA 301132 Correspondence Reference Number: 30025 Dear FCC: I am writing In response to Linda Elliott’s email inquiry dated November 25, 2005. The correct FCC ID for the device specified in FCC Form 731, Confirmation Number EA301132, is O2E-ILR-IP3NA. Please revise your records to reflect the correct FCC ID. Should questions arise, please give me a call. Very truly yours, Robert H. Schwaninger Robert H. Schwaninger, Jr. Richard P. Hanno Vic Jackson Interconnection Consultant

Cover Letter(s)

Schwaninger & Associates, P.C. Attorneys at Law 1331 H Street, N.W., Suite 500, Washington, DC 20005 Internet Address – http://www.sa-lawyers.net telephone – (202) 347-8580 facsimile – (202) 347-8607 January 18, 2006 Federal Communications Commission 445 12 th Street SW Washington, DC 20554 Re:Identec Solutions, Inc. 731 Confirmation Number EA 301132 Correspondence Reference Number 30025 Dear FCC: I am writing in response to Andrew Leimer’s email inquiry dated January 10, 2006. Test set up photos are transmitted along with this correspondence. Should questions arise please give me a call. Very truly yours, Robert H. Schwaninger Robert H. Schwaninger, Jr. Richard P. Hanno Vic Jackson Interconnection Consultant

External Photos

Rhein Tech Laboratories, Inc. Client: Identec Solutions, Inc. 360 Herndon Parkway Model: i-PORT 3 Suite 1400 Report No: 2005011 Herndon, VA 20170 Standards: FCC 15.245/IC RSS-210 http://www.rheintech.com Date: May 11, 2005 Page 43 of 48 APPENDIX J: EXTERNAL PHOTOGRAPHS PHOTOGRAPH 14: MAGNETIC MOUNT WHIP ANTENNA Rhein Tech Laboratories, Inc. Client: Identec Solutions, Inc. 360 Herndon Parkway Model: i-PORT 3 Suite 1400 Report No: 2005011 Herndon, VA 20170 Standards: FCC 15.245/IC RSS-210 http://www.rheintech.com Date: May 11, 2005 Page 44 of 48 PHOTOGRAPH 15: PATCH ANTENNA PHOTOGRAPH 16: YAGI ANTENNA

ID Label/Location Info

Rhein Tech Laboratories, Inc. Client: Identec Solutions, Inc. 360 Herndon Parkway Model: i-PORT 3 Suite 1400 Report No: 2005011 Herndon, VA 20170 Standards: FCC 15.245/IC RSS-210 http://www.rheintech.com Date: May 11, 2005 Page 30 of 48 APPENDIX C: LABEL AND LOCATION Please refer to the following pages for a label sample, and photograph of the label location. Model: Type: Part No.: 05214P0001 878932 NA-A/DC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference , and (2) this device must accept any interference received, including interference that may cause undesired operation. i-PORT 3 IC: 3538B-IPORT3 FCC ID: 02E-ILR-IP3NA Rhein Tech Laboratories, Inc. Client: Identec Solutions, Inc. 360 Herndon Parkway Model: i-PORT 3 Suite 1400 Report No: 2005011 Herndon, VA 20170 Standards: FCC 15.245/IC RSS-210 http://www.rheintech.com Date: May 11, 2005 Page 31 of 48 PHOTOGRAPH 1: FCC ID LABEL LOCATION FCC ID LABEL PLACEMENT ON SIDE OF EUT

ID Label/Location Info

Rhein Tech Laboratories, Inc. Client: Identec Solutions, Inc. 360 Herndon Parkway Model: i-PORT 3 Suite 1400 Report No: 2005011 Herndon, VA 20170 Standards: FCC 15.245/IC RSS-210 http://www.rheintech.com Date: May 11, 2005 Page 45 of 48 PHOTOGRAPH 17: TOP VIEW PHOTOGRAPH 18: INSIDE COVER

Internal Photos

Rhein Tech Laboratories, Inc. Client: Identec Solutions, Inc. 360 Herndon Parkway Model: i-PORT 3 Suite 1400 Report No: 2005011 Herndon, VA 20170 Standards: FCC 15.245/IC RSS-210 http://www.rheintech.com Date: May 11, 2005 Page 46 of 48 APPENDIX K: INTERNAL PHOTOGRAPHS PHOTOGRAPH 19: CPU BOARD FRONT Rhein Tech Laboratories, Inc. Client: Identec Solutions, Inc. 360 Herndon Parkway Model: i-PORT 3 Suite 1400 Report No: 2005011 Herndon, VA 20170 Standards: FCC 15.245/IC RSS-210 http://www.rheintech.com Date: May 11, 2005 Page 47 of 48 PHOTOGRAPH 20: CPU BOARD BACK Rhein Tech Laboratories, Inc. Client: Identec Solutions, Inc. 360 Herndon Parkway Model: i-PORT 3 Suite 1400 Report No: 2005011 Herndon, VA 20170 Standards: FCC 15.245/IC RSS-210 http://www.rheintech.com Date: May 11, 2005 Page 48 of 48 PHOTOGRAPH 21: RF BOARD FRONT Rhein Tech Laboratories, Inc. Client: Identec Solutions, Inc. 360 Herndon Parkway Model: i-PORT 3 Suite 1400 Report No: 2005011 Herndon, VA 20170 Standards: FCC 15.245/IC RSS-210 http://www.rheintech.com Date: May 11, 2005 Page 49 of 48 PHOTOGRAPH 22: RF BOARD BACK Rhein Tech Laboratories, Inc. Client: Identec Solutions, Inc. 360 Herndon Parkway Model: i-PORT 3 Suite 1400 Report No: 2005011 Herndon, VA 20170 Standards: FCC 15.245/IC RSS-210 http://www.rheintech.com Date: May 11, 2005 Page 50 of 48 PHOTOGRAPH 23: I/O BOARD FRONT Rhein Tech Laboratories, Inc. Client: Identec Solutions, Inc. 360 Herndon Parkway Model: i-PORT 3 Suite 1400 Report No: 2005011 Herndon, VA 20170 Standards: FCC 15.245/IC RSS-210 http://www.rheintech.com Date: May 11, 2005 Page 51 of 48 PHOTOGRAPH 24: I/O BOARD BACK

Parts List/Tune Up Info

Rhein Tech Laboratories, Inc. Client: Identec Solutions, Inc. 360 Herndon Parkway Model: i-PORT 3 Suite 1400 Report No: 2005011 Herndon, VA 20170 Standards: FCC 15.245/IC RSS-210 http://www.rheintech.com Date: May 11, 2005 Page 32 of 48 APPENDIX D: ANTENNA SPECIFICATIONS Antenna Type Gain (dBi) Patch 8 YAGI 7 Magnetic Mount Whip 5

Test Report

Engineering and Testing for EMC and Safety Compliance 360 Herndon Parkway, Suite 1400 Herndon, VA 20170 Phone: 703-689-0368; Fax: 703-689-2056 CERTIFICATION APPLICATION REPORT FCC PART 15.245 & INDUSTRY CANADA RSS-210 MODEL: i-Port 3 FCC ID: O2E-ILR-IP3NA IC: 3538B-IPORT3 Identec Solutions, Inc. #102 – 1860 Dayton Street Kelowna, BC Canada V1Y 7W6 Tel: (250) 860-6567 Fax: (250) 860-6541 May 11, 2005 Standards Referenced for This Report Part 2: 2004 Frequency Allocations and Radio Treaty Matters; General Rules and Regulations Part 15: 2004 Radio Frequency Devices ANSI C63.4-2003 Standard Format Measurement/Technical Report Personal Computer and Peripherals RSS-210; 2001 Low Power License-Exempt Radio Communication Devices (All Frequency Bands) FCC Part Frequency Range (MHz) Output Power (W) Frequency Tolerance Emission Designator 15.245 905-914.8 N/A N/A N/A I, the undersigned, hereby declare that the equipment tested and referenced in this report conforms to the identified standard(s) as described in this test report. Modifications made to the equipment during testing, in order to achieve compliance with these standards, are listed in the report. Furthermore, there was no deviation from, additions to, or exclusions from the FCC Part 2, FCC Part 15, Industry Canada RSS-210, and ANSI C63.4. Signature: Date: May 11, 2005 Typed/Printed Name: Desmond A. Fraser Position: President This report may not be reproduced, except in full, without the written approval of Rhein Tech Laboratories, Inc. Rhein Tech Laboratories, Inc. Client: Identec Solutions, Inc. 360 Herndon Parkway Model: i-PORT 3 Suite 1400 Report No: 2005011 Herndon, VA 20170 Standards: FCC 15.245/IC RSS-210 http://www.rheintech.com Date: May 11, 2005 Page 2 of 48 TABLE OF CONTENTS 1 GENERAL INFORMATION ................................................................................................................. 5 1.1 MODIFICATIONS .......................................................................................................................................... 5 1.2 RELATED SUBMITTAL(S)/GRANT(S) .......................................................................................................... 5 1.3 TEST METHODOLOGY ................................................................................................................................ 5 1.4 TEST FACILITY............................................................................................................................................. 5 2 SYSTEM TEST CONFIGURATION ..................................................................................................... 6 2.1 JUSTIFICATION ............................................................................................................................................ 6 2.2 EXERCISING THE EUT ................................................................................................................................ 6 2.3 TEST SYSTEM DETAILS .............................................................................................................................. 6 2.4 CONFIGURATION OF TESTED SYSTEM .................................................................................................... 7 3 RADIATED EMISSIONS...................................................................................................................... 8 3.1 TEST METHODOLOGY FOR RADIATED EMISSIONS MEASUREMENTS................................................. 8 3.2 RADIATED EMISSION DATA - FCC §15.245 ............................................................................................... 9 4 CONDUCTED LIMITS - §15.207 ....................................................................................................... 10 4.1 TEST METHODOLOGY FOR CONDUCTED LINE EMISSIONS MEASUREMENTS ................................. 10 4.2 CONDUCTED LINE EMISSIONS TEST...................................................................................................... 10 4.3 CONDUCTED LINE EMISSIONS TEST EQUIPMENT................................................................................ 10 4.4 CONDUCTED LINE EMISSIONS TEST DATA ........................................................................................... 11 5 RADIATED SPURIOUS AND HARMONIC EMISSIONS - §2.1053.................................................. 17 5.1 HARMONIC RADIATED EMISSIONS TEST DATA - FCC §15.245 ............................................................ 17 6 CONCLUSION ................................................................................................................................... 27 Rhein Tech Laboratories, Inc. Client: Identec Solutions, Inc. 360 Herndon Parkway Model: i-PORT 3 Suite 1400 Report No: 2005011 Herndon, VA 20170 Standards: FCC 15.245/IC RSS-210 http://www.rheintech.com Date: May 11, 2005 Page 3 of 48 FIGURE INDEX FIGURE 2-1: TEST SYSTEM CONFIGURATION ..................................................................................................... 7 TABLE INDEX TABLE 2-1: EQUIPMENT UNDER TEST (EUT) .....................................................................................................6 TABLE 2-2: ASSOCIATED TEST EQUIPMENT......................................................................................................6 TABLE 3-1: FUNDAMENTAL RADIATED EMISSIONS – MAGNETIC MOUNT WHIP ANTENNA ......................... 9 TABLE 3-2: FUNDAMENTAL RADIATED EMISSIONS – YAGI ANTENNA............................................................ 9 TABLE 3-3: FUNDAMENTAL RADIATED EMISSIONS - PATCH ANTENNA ......................................................... 9 TABLE 4-1: CONDUCTED LINE EMISSIONS TEST EQUIPMENT ...................................................................... 10 TABLE 4-2: CONDUCTED EMISSIONS (NEUTRAL SIDE); MODE: DIGITAL-RECEIVER - WHIP ANTENNA ... 11 TABLE 4-3: CONDUCTED EMISSIONS (PHASE SIDE); MODE: DIGITAL-RECEIVER - WHIP ANTENNA ........ 11 TABLE 4-4: CO…

Text truncated - open the document above for the full version.

Test Setup Photos

Rhein Tech Laboratories, Inc. Client: Identec Solutions, Inc. 360 Herndon Parkway Model: i-PORT 3 Suite 1400 Report No: 2005011 Herndon, VA 20170 Standards: FCC 15.245/IC RSS-210 http://www.rheintech.com Date: May 11, 2005 Page 41 of 48 PHOTOGRAPH 10: CONDUCTED EMISSIONS TEST CONFIGURATION - PATCH ANTENNA FRONT VIEW PHOTOGRAPH 11: CONDUCTED EMISSIONS TEST CONFIGURATION - PATCH ANTENNA BACK VIEW Rhein Tech Laboratories, Inc. Client: Identec Solutions, Inc. 360 Herndon Parkway Model: i-PORT 3 Suite 1400 Report No: 2005011 Herndon, VA 20170 Standards: FCC 15.245/IC RSS-210 http://www.rheintech.com Date: May 11, 2005 Page 42 of 48 PHOTOGRAPH 12: CONDUCTED EMISSIONS TEST CONFIGURATION - YAGI ANTENNA FRONT VIEW PHOTOGRAPH 13: CONDUCTED EMISSIONS TEST CONFIGURATION - YAGI ANTENNA BACK VIEW

Test Setup Photos

Rhein Tech Laboratories, Inc. Client: Identec Solutions, Inc. 360 Herndon Parkway Model: i-PORT 3 Suite 1400 Report No: 2005011 Herndon, VA 20170 Standards: FCC 15.245/IC RSS-210 http://www.rheintech.com Date: May 11, 2005 Page 43 of 48 APPENDIX J: EXTERNAL PHOTOGRAPHS PHOTOGRAPH 14: MAGNETIC MOUNT WHIP ANTENNA Rhein Tech Laboratories, Inc. Client: Identec Solutions, Inc. 360 Herndon Parkway Model: i-PORT 3 Suite 1400 Report No: 2005011 Herndon, VA 20170 Standards: FCC 15.245/IC RSS-210 http://www.rheintech.com Date: May 11, 2005 Page 44 of 48 PHOTOGRAPH 15: PATCH ANTENNA PHOTOGRAPH 16: YAGI ANTENNA

Test Setup Photos

Rhein Tech Laboratories, Inc. Client: Identec Solutions, Inc. 360 Herndon Parkway Model: i-PORT 3 Suite 1400 Report No: 2005011 Herndon, VA 20170 Standards: FCC 15.245/IC RSS-210 http://www.rheintech.com Date: May 11, 2005 Page 39 of 48 PHOTOGRAPH 6: RADIATED EMISSIONS TEST CONFIGURATION - YAGI ANTENNA FRONT VIEW PHOTOGRAPH 7: RADIATED EMISSIONS TEST CONFIGURATION - YAGI ANTENNA REAR VIEW Rhein Tech Laboratories, Inc. Client: Identec Solutions, Inc. 360 Herndon Parkway Model: i-PORT 3 Suite 1400 Report No: 2005011 Herndon, VA 20170 Standards: FCC 15.245/IC RSS-210 http://www.rheintech.com Date: May 11, 2005 Page 40 of 48 PHOTOGRAPH 8: CONDUCTED EMISSIONS TEST CONFIGURATION - MAGNETIC MOUNT WHIP ANTENNA FRONT VIEW \ PHOTOGRAPH 9: CONDUCTED EMISSIONS TEST CONFIGURATION - MAGNETIC MOUNT WHIP ANTENNA BACK VIEW

Contact Information

Applicant

Barry Allen(VP Engineering)
[email protected]972-535-4144Fax: 469-424-0404

Technical Contact

Rhein Tech LaboratoriesRick McMurray
[email protected]7036890368

360 Herndon Parkway · Herndon, Virginia · United States

Non-Technical Contact

Schwaninger & Associates, P.C.Robert H Schwaninger
[email protected]2023478580

Test Firm

Rhein Tech Laboratories, Inc.Rick McMurray
[email protected]703-689-0368Fax: 703-689-2056

Technical Specifications

#Rule PartsFrequency RangePower Output
115.245905 MHz - 914.8 MHz-
Confidentiality
Long Term

Other Applications from Identec Solutions, Inc.

Position Marker - FCC ID O2E-ILR-IM2 - Identec Solutions, Inc.
O2E-ILR-IM2

Position Marker

Jan 28, 2008

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Position Marker - FCC ID O2E-ILR-IM3 - Identec Solutions, Inc.
O2E-ILR-IM3

Position Marker

Jul 05, 2007

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Type II PCMCIA Mobile RFID Reader - FCC ID O2E-ILR-ICARDIII - Identec Solutions, Inc.
O2E-ILR-ICARDIII

Type II PCMCIA Mobile RFID Reader

May 09, 2004

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
transmits and receives data for identification - FCC ID O2E-ILR-IPORT3 - Identec Solutions, Inc.
O2E-ILR-IPORT3

transmits and receives data for identification

Nov 12, 2003

Equipment Class

FDS - Part 15 Field Disturbance Sensor
i-Q8C ILR Tag - FCC ID O2E-ILR-IQ8C - Identec Solutions, Inc.
O2E-ILR-IQ8C

i-Q8C ILR Tag

Jul 02, 2003

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified