Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
type : titre : I7770 external pictures for FCC submission Page : Version : Date : 1 / 4 1.0 10/12/03 type : titre : I7770 external pictures for FCC submission Page : Version : Date : 2 / 4 1.0 10/12/03 type : titre : I7770 external pictures for FCC submission Page : Version : Date : 3 / 4 1.0 10/12/03 type : titre : I7770 external pictures for FCC submission Page : Version : Date : 4 / 4 1.0 10/12/03
Ingenico Canada Ltd., 79 Torbarrie Road, Toronto, Ontario, M3L 1G5, Canada Tel: (416) 245-6700 Fax: (416) 245-6701 The following diagrams show the format and location of the product labels on the INGENICO 7770. Diagram 1: INGENICO 7770 hand held product label format and text. Ingenico Canada Ltd., 79 Torbarrie Road, Toronto, Ontario, M3L 1G5, Canada Tel: (416) 245-6700 Fax: (416) 245-6701 Diagram 2: INGENICO 7770 radio base product label format and text. Ingenico Canada Ltd., 79 Torbarrie Road, Toronto, Ontario, M3L 1G5, Canada Tel: (416) 245-6700 Fax: (416) 245-6701 Diagram 3: Position of the INGENICO 7770 product labels.
Ingenico Canada Ltd., 79 Torbarrie Road, Toronto, Ontario, M3L 1G5, Canada Tel: (416) 245-6700 Fax: (416) 245-6701 The following diagrams show the format and location of the product labels on the INGENICO 7770. Diagram 1: INGENICO 7770 hand held product label format and text. Ingenico Canada Ltd., 79 Torbarrie Road, Toronto, Ontario, M3L 1G5, Canada Tel: (416) 245-6700 Fax: (416) 245-6701 Diagram 2: INGENICO 7770 radio base product label format and text. Ingenico Canada Ltd., 79 Torbarrie Road, Toronto, Ontario, M3L 1G5, Canada Tel: (416) 245-6700 Fax: (416) 245-6701 Diagram 3: Position of the INGENICO 7770 product labels.
November 10, 2003 File No.: IVI-123-SAR Ingenico Canada Ltd. 79 Tobarrie Road Toronto, Ontario CANADA, M3L 1G5 NOT TRANSFERABLE This Verification Certificate is hereby issued to the named GRANTEE and is VALID ONLY for the equipment identified hereon for use under the rules and regulations listed below: GRANTEE'S NAME: Ingenico Canada Ltd. PRODUCT UNDER TEST: INGENICO 7770 POS Terminal MODEL NO.: INGENICO 7770 FCC ID: O34-I7770 OPERATING FREQUENCY RANGE: 2402 ~ 2480 MHz MAX. PEAK RF OUTPUT POWER: 18.18 dBm conducted DEVICE CATEGORY: Portable EXPOSURE CATEGORY: General Population/Uncontrolled MAX. PEAK SPATIAL-AVERAGE SAR 1g : 1.09 W/Kg This wireless portable device has been shown to be compliant for Specific Absorption Rate (SAR) for General Population/Uncontrolled exposure limit. APPLICABLE STANDARDS: SAR (Specific Absorption Rate) requirements using guidelines established in IEEE C95.1-1991, FCC OET Bulletin 65 (Supplement C Edition 01-01), Industry Canada RSS-102(Issue 1) and ACA Radiocommunications (Electromagnetic Radiation – Human Exposure) Amendment Standard 2000 (No. 1) Approved by: Tri M. Luu, P.Eng. V.P. – Engineering UltraTech 3000 Bristol Circle, Oakville, Ontario, Canada, L6H 6G4 Tel.: (905) 829-1570 Fax.: (905) 829-8050 Website: www.ultratech-labs.com Email: [email protected], Email: [email protected] 2 31040/SIT C-1376 46390-2049 200093-0 00-034
UltraTech Group of Labs November 10, 2003 Ingenico Canada Ltd. 79 Tobarrie Road TORONTO, ONTARIO CANADA, M3L 1G5 Attn.: Mr. Relja Janjic Subject: Verification Testing in accordance with SAR (Specific Absorption Rate) requirements using guidelines established in: IEEE C95.1-1991, FCC OET Bulletin 65 (Supplement C) Industry Canada RSS-102 (Issue 1) ACA Radiocommunications (Electromagnetic Radiation – Human Exposure) Amendment Standard 2000 (No. 1) Product: Portable point of sales electronic payment terminal Model: INGENICO 7770 Dear Mr. Janjic The product sample has been tested in accordance with SAR (Specific Absorption Rate) requirements using guidelines established in IEEE C95.1-1991, FCC OET Bulletin 65 (Supplement C), Industry Canada RSS-102 (Issue 1)and ACA Radiocommunications (Electromagnetic Radiation – Human Exposure) Amendment Standard 2000 (No. 1), and the results and observation were recorded in the engineering report, Our File No.: IVI-123-SAR Enclosed you will find a copy of the engineering report. If you have any queries, please do not hesitate to contact us. Yours truly, Tri Minh Luu, P.Eng Vice President - Engineering Encl. 31040/SIT A96/TH/0093 46390-2049 200093-0 2 00-034 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 Telephone (905) 829-1570 Facsimile (905) 829-8050 Website: www.ultratech-labs.com Email: [email protected]
Portable point of sales electronic payment terminal Model No.: INGENICO 7770 Tested For Ingenico Canada Ltd. 79 Tobarrie Road CANADA In Accordance With SAR (Specific Absorption Rate) Requirements using guidelines established in IEEE C95.1-1991, FCC OET Bulletin 65 (Supplement C), Industry Canada RSS-102(Issue 1) and ACA Radiocommunications (Electromagnetic Radiation – Human Exposure) Amendment Standard 2000 (No. 1) UltraTech's File No.: IVI-123-SAR This Test report is Issued under the Authority of Tri M. Luu, Professional Engineer, Vice President of Engineering UltraTech Group of Labs Date: November 10, 2003 Report Prepared by: JaeWook Choi, SAR System Engineer Tested by: JaeWook Choi, SAR System Engineer Issued Date: November 10, 2003 Test Dates: October 23, 2003 The results in this Test Report apply only to the sample(s) tested, which has been randomly selected. UltraTech 3000 Bristol Circle, Oakville, Ontario, Canada, L6H 6G4 Telephone (905) 829-1570 Facsimile (905) 829-8050 Website: www.ultratech-labs.com Email: [email protected] SPECIFIC ABSORPTION RATE (SAR) Page 1 IEEE C95.1-1991, FCC OET Bulletin 65 (Supplement C), Industry Canada RSS-102(Issue 1) and ACA Radiocommunications (Electromagnetic Radiation – Human Exposure) Amendment Standard 2000 (No. 1) INGENICO POS Terminal M/N: INGENICO 7770 FCC ID: O34-I7770 TABLE OF CONTENTS EXHIBIT 1. INTRODUCTION................................................................................................................................................4 1.1. SCOPE...............................................................................................................................................................................4 1.2. REFERENCES...................................................................................................................................................................4 EXHIBIT 2. PERFORMANCE ASSESSMENT.....................................................................................................................5 2.1. CLIENT AND MANUFACTURER INFORMATION......................................................................................................5 2.2. DEVICE UNDER TEST (D.U.T.) DESCRIPTION..............................................................................................................5 2.3. LIST OF D.U.T.’S ACCESSORIES:.................................................................................................................................. 6 2.4. SPECIAL CHANGES ON THE D.U.T.’S HARDWARE/SOFTWARE FOR TESTING PURPOSES.............................6 2.5. ANCILLARY EQUIPMENT.............................................................................................................................................6 2.6. GENERAL TEST CONFIGURATIONS...........................................................................................................................6 2.6.1. Equipment Configuration...........................................................................................................................................6 2.6.2. Exercising Equipment.................................................................................................................................................6 2.7. SPECIFIC OPERATING CONDITIONS......................................................................................................................................6 2.8. BLOCK DIAGRAM OF TEST SETUP.............................................................................................................................7 EXHIBIT 3. SUMMARY OF TEST RESULTS......................................................................................................................8 3.1. LOCATION OF TESTS.....................................................................................................................................................8 3.2. APPLICABILITY & SUMMARY OF SAR RESULTS.....................................................................................................8 EXHIBIT 4. MEASUREMENTS, EXAMINATIONS & TEST DATA................................................................................9 4.1. TEST SETUP.....................................................................................................................................................................9 4.2. PHOTOGRAPH OF D.U.T. AND ALL ACCESORIES................................................................................................................10 4.3. PHOTOGRAPHS OF D.U.T. POSITION........................................................................................................................14 4.3.1. Body Configuration..................................................................................................................................................14 4.4. MAXIMUM PEAK SPATIAL-AVERAGE SAR........................................................................................................................17 4.4.1. Maximum Peak Spatial-average SAR Data..............................................................................................................17 4.4.2. Maximum Peak Spatial-Average SAR Location.......................................................................................................17 4.5. SAR MEASUREMENT DATA..............................................................................................................................................18 4.5.1. Body Configuration Result.......................................................................................................................................18 4.5.2. Power Measurement.................................................................................................................................................19 EXHIBIT 5. SAR SYSTEM CONFIGURATION & TEST METHODOLOGY................................................................20 …
Text truncated - open the document above for the full version.
RIA-03-24471-A EMITECH ATLANTIQUE 15, rue de la Claie Z.I. Angers-Beaucouzé 49070 BEAUCOUZÉ Tél. 02 41 73 26 27 Fax 02 41 73 26 40 e-mail : [email protected] R.C.S. ANGERS 95 B 543 SIRET 344 545 645 00055 SIEGE SOCIAL : EMITECH S.A. 3, rue des Coudriers – Z.A. de l’Observatoire – 78180 MONTIGNY-LE-BRETONNEUX – Tél. 01 30 57 55 55 – Fax 01 30 43 74 48 S.A. AU CAPITAL DE 480 000 € - R.C. VERSAILLES B 344 545 645 – SIRET 344 545 645 000 22 – CODE APE 742 C RA-03-24471/A/ST FCC CERTIFICATION E.M.C. Measurement Technical Report standard to apply: FCC Part 15 Equipment under test: POINT OF SALE HAND HELD TERMINAL + BASE STATION FCC ID: 034-I7770 Company: INGENICO TRANSMIT TO: Mr SCHANG Company: INGENICO Number of pages: 22 + 7 appendixes Verification Ed. Date ModifiedEditing Approval pages Name Visa Name Visa 0 8-Dec-03 Creation P. BONNENFANT Duplication of this test report is only permitted for an integral photographic facsimile. It includes the number of pages referenced here above. This document is the result of testing a specimen or a sample of the product submitted. It does not imply an assessment of the conformity of the whole manufactured products of the tested sample. EMITECH ATLANTIQUE RA-03-24471 DATE: 8-Dec-03 PAGE: 2 / 22 RIA-03-24471-A PRODUCT: POINT OF SALE HAND HELD TERMINAL + BASE STATION Reference / model : I 7770 Serial number : I7770BHT001A v01 (hand held terminal) I7770BAS001A v2.1 (base station) MANUFACTURER: INGENICO COMPANY SUBMITTING THE PRODUCT: Company: INGENICO Address: 9, quai de Dion Bouton 92816 PUTEAUX CEDEX FRANCE Responsible: Mr SCHANG DATE(S) OF TEST: 16, 17 and 18 June 2003 03 December 2003 TESTING LOCATION: EMITECH ATLANTIQUE laboratory at ANGERS (49) FRANCE EMITECH ATLANTIQUE open area test site in LA POUEZE (49) FRANCE EMITECH laboratory at MONTIGNY LE BRETONNEUX (78) FRANCE Registration Number by FCC: 101696/FRN: 0006 6490 08 Registration Number by Industry Canada: IC4379 TESTED BY: P. BONNENFANT EMITECH ATLANTIQUE RA-03-24471 DATE: 8-Dec-03 PAGE: 3 / 22 RIA-03-24471-A CONTENTS TITLE PAGE 1. INTRODUCTION.......................................................................................................................... 4 2. PRODUCT DESCRIPTION .........................................................................................................4 3. NORMATIVE REFERENCE....................................................................................................... 4 4. TEST METHODOLOGY .............................................................................................................5 5. RELATED SUBMITTAL GRANT .............................................................................................. 5 6. ADD ATTACHMENTS FILES .................................................................................................... 5 7. TESTS AND CONCLUSIONS HAND HELD TERMINAL ..................................................... 6 8. TESTS AND CONCLUSIONS BASE STATION....................................................................... 7 9. CONDUCTED EMISSION ON AC MAINS PORTS BASE STATION .................................. 8 10. PEAK OUTPUT POWER HAND HELD TERMINAL......................................................... 10 11. PEAK OUTPUT POWER BASE STATION .......................................................................... 12 12. RADIATED EMISSION HAND HELD TERMINAL ........................................................... 14 13. RADIATED EMISSION BASE STATION ............................................................................. 16 14. RADIATED EMISSION HAND HELD TERMINAL ........................................................... 18 15. RADIATED EMISSION BASE STATION ............................................................................. 20 16. APPENDIXES ............................................................................................................................ 22 APPENDIX 1: SCHANNEL SEPARATION BASE STATIONT................................................ 22 APPENDIX 2: S CHANNEL SEPARATION HAND HELD TERMINALT.............................. 22 APPENDIX 3: STIMING HOPPING AND TIMING CHANNEL BASE STATIONT............... 22 APPENDIX 4: STIMING HOPPING AND TIMING CHANNEL HAND HELD TERMINALT22 APPENDIX 5: SCONDUCTED EMISSIONS ON POWER SUPPLY T.................................... 22 APPENDIX 6: S PHOTOGRAPHIES OF THE EQUIPMENT UNDER TESTT........................ 22 APPENDIX 7: S PHOTOGRAPHIES OPEN AREA AND SET UPT......................................... 22 EMITECH ATLANTIQUE RA-03-24471 DATE: 8-Dec-03 PAGE: 4 / 22 RIA-03-24471-A 1.INTRODUCTION This document presents the result of E.M.C. test carried out on the following equipment: POINT OF SALE HAND HELD TERMINAL + BASE STATION in accordance with normative reference. 2.PRODUCT DESCRIPTION ITU Emission code: 1M00F7D Classe: A (commercial, industrial or business environment) Utilization: banking terminal of payment connected to the telephone network through a modem. Antenna type: incorporated antenna Antenna gain: 0 dBi (base and terminal) Operating frequency range: from 2400 MHz to 2483.5 MHz No of channels: 79 Channel spacing: 1 MHz Frequency generation: | SAW Resonator | Crystal ~ Synthetiser Modulation: Frequency Hopping Spread Spectrum | Amplitude | Digital ~ Frequency | Phase Power source: mains power adaptator for base station Batteries Ni mH (5 × 1.2V) for hand held terminal Power level, frequency range and channels characteristics are not user adjustable. The details pictures of the product, the circuit boards and antennas are joined with this file. 3.NORMATIVE REFERENCE FCC Part 15 (03) Code of Federal Regulations Title 47 - Telecommunication Chapter 1 - Federal Communications Commission Part 15 - Radio frequency devices Subpart C - Intentional Radiators ANSI C63.4 (01) Methods of measurement of Radio-Noise Emissions from low-voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz. EMITECH ATLANTIQUE RA-03-24471…
Text truncated - open the document above for the full version.
A7-RA-03-24471 DATE: 8-Dec-03 PAGE: 1 / 4 A7-RA-03-24471-A APPENDIX 7 PHOTOGRAPHIES A7-RA-03-24471 DATE: 8-Dec-03 PAGE: 2 / 4 A7-RA-03-24471-A PHOTOGRAPHY RADIATED TEST SET UP TERMINAL PHOTOGRAPHY CONDUCTED TEST SET UP BASE A7-RA-03-24471 DATE: 8-Dec-03 PAGE: 3 / 4 A7-RA-03-24471-A PHOTOGRAPHY RADIATED TEST SET UP BASE A7-RA-03-24471 DATE: 8-Dec-03 PAGE: 4 / 4 A7-RA-03-24471-A PHOTOGRAPHY OPEN AREA TEST SITE: WEATHER PROTECTION ENCLOSURE
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 100.00 mW |

CONTACTLESS PAYMENT EXPANSION MODULE
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Point of Sale, Base Station
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Point of Sale, Hand held Terminal
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
ELITE 790 GPRS POINT OF SALE TERMINAL
Equipment Class
PCT - PCS Licensed Transmitter worn on body
Point of sale, base station
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter