FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Youngshin Electronics Co., LTD./
  3. O44J1WENR

O44J1WENRCar Alarm System

Youngshin Electronics Co., LTD.
Car Alarm System - FCC ID O44J1WENR - Youngshin Electronics Co., LTD.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
May 26, 2005
Application Purpose
Original Equipment
Date of Application
May 26, 2005
Equipment Note
Car Alarm System
Frequency Range
433.92000000 - 433.92000000
Company
Youngshin Electronics Co., LTD.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

External Photos

↗
↗

ID Label/Location Info

↗

Internal Photos

↗
↗

Operational Description

↗

Schematics

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

USER’S GUIDE FCC ID : O44J1WENR This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions : (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. CAUTION : Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this device. User’s GUIDE TABLE OF CONTENTS Safety Information Remote : Remote Button Functions Remote Learning Routine Keyless Entry Alarm Mode Trunk Release Panic Mode Valet Mode Optional Programmable Features Ignition Lock Passive Locking Optional Installation Features Door pulse Duration Flashing Signal Light Anti-jacking Page 4 Page 4 Page 5 Page 5 Page 6 Page 6 Page 7 Page 7 Page 7 Page 8 Page 8 Page 8 Page 8 Page 8 Page 8 Page 8 Page 3 User’s GUIDE The model name, R500 stands for Safety Information Please take these safety precautions into consideration, under the following conditions : Page 4 When servicing your automobile (i.e. changing the oil, washing your car), the Magicar system should be in Valet Mode. Whenever you loan your vehicle to an individual who is not familiar with Magicar, please put the vehicle in Valet mode. This will prevent the vehicle barrower from accidentally activating the Magicar auto-security system. Remote Page 5 Remote Button Functions 1 2 3 4 5 6 7 8 9 10 Lock0.5 sec 0.5 sec 0.5 sec 0.5 sec Unlock Button PressFunction 2 sec Panic, Press Lock to shut off Siren Valet Mode - on/off Siren Chirps for Lock /Unlock - on/off 0.5 sec Ignition Lock - on/off 0.5 sec Passive Arming - on/off 0.5 sec Shock Sensor - on/off 2 sec Trunk Release 2 sec Programming Menu - Installer Only Means pressing the button for 2 seconds. Means simultaneously pressing the buttons. Means simultaneously pressing the buttons for 2 seconds. Remote Learning Routine The Magicar will allow up to three remotes to be programmed to one vehicle. Please perform the following procedure to add or reprogram additional remotes. Activate Valet/ Programming mode by manually turning the ignition on and off three times with the key within a 7 second period. The parking lights will flash once with successful completion of this step. You can exit Valet Mode only by pressing buttons simultaneously. To arm the vehicle, press the button . To disarm the vehicle, press the button. If pressing the arm/disarm buttons does not arm/disarm the vehicle, you will need to release the button and try again, as the remote stops transmitting as soon as the LED stops flashing. Press the buttons for a 0.5 second to mute the vehicle siren when arming or disarming your vehicle. Keep in mind that your siren will still be activated for all other modes(i.e.panic or alarm trigger) regardless of whether or not your siren is in mute mode. The siren will be mute only when arming or disarming your vehicle. When the alarm is armed, the starter kill function (an optional feature provided by your installer) is activated. This feature disengages the starter mechanism on your vehicle and prevents it from starting, even with a key. To lock the vehicle, pressing the button for a 0.5 second. To unlock the vehicle, press the button for a 0.5 second. If the pressing of the lock/unlock buttons does not lock/unlock the doors, you will need to release the button and try again, as the remote stops transmitting as soon as the LED stops flashing. If the button is pressed for 2 seconds, it will panic the system. Page 7 Keyless Entry Alarm Mode Page 6 Within a 7 second period after cycling the ignition for the 3 rd time, Press the button for a 0.5 second. The parking lights will flash once to confirm that the transmitter has been programmed. You can continue programming additional remotes. The parking lights will flash two times when the programming mode has expired. If you lose your remote after you have armed the vehicle, use your key to open the door. The siren will go off. Turn the ignition on and off, 3 times with your key to shut down the alarm and put the system into valet mode. You can cancel valet mode with a remote later on. See: Valet mode, on page 7. Trunk Release Press the button for 2 seconds, in order to unlock and release your trunk door. If pressing the trunk release button does not release the trunk, you will need to release the button and try again, as the remote stops transmitting as soon as the LED stops flashing.Note that the trunk release function will not only release the trunk but will unlock the all doors as well. Panic Mode If Anti-Jackingoption has been programmed (ask your dealer if you would like to have this option) and the Ignition-Kill has been installed , Panic Mode works as Anti-Jacking if the car key in the ignition. In Anti-Jacking mode is activated while key is in the ignition, a) the Siren will go off for 1.5 minutes, and b) Ignition-Kill will be activated after the first 30 seconds. This is to give a 30 second warning to the hijacker, then to disconnect the ignition to stop the vehicle. Press the button for 2 seconds to enter Panic Mode. In this mode, the car will be armed,if not armed already, and the siren will be activated and the parking lights will be flashed. In order to disengage Panic Mode, press the button. Then, press the button for a 0.5 secondto unlock/ disarm your vehicle. Valet Mode While the vehicle is in valet mode, the only feature is the keyless entry and optional auxiliary functions. In order to enter Valet mode, press the buttons simultaneously for a 0.5 sec- ond. In order to manually enter Valet Mode, insert your car key into the ignition and turn the ignition on and off three times within 7 seconds Page 9Page 8 OPTIONAL PROGRAMMABLE FEATURES Ignition Lock These additional features may be programmed to the Magicar system by your authorized Magicar dealer. This programmable option enables your vehicle to automatically lock the doors once the key is i…

Text truncated - open the document above for the full version.

Test Report

Ref. Report No. Name and address of the applicant Youngshin Electronic Co., Ltd. 102-701, Bucheon Techno-park 364 Smajeong-dong, Ojeong-gu, Bucheon-si, Gyeonggi-do, 421-740 Korea Standard / Test regulation FCC Part 15, Subpart C Test result Pass Incoming date : March 14, 2005 Test item(s) ; Security/Remote Control Transmitter (Car Alarm System) Model/type ref. ; 1WENR Manufacturer ; Youngshin Electronic Co., Ltd. Additional information ; -Required Authorization : Certification -FCC ID. : O44J1WENR Test date : May 10, 2005 Issue date : May 24, 2005 This test report only responds to the tested sample and shall not be reproduced except in full without written approval of the Korea Testing Laboratory. Tested and reported by Reviewed by Jeong-Min Kim, Senior Engineer Won-Seo Cho , Telecommunication Team Manager FG101-01-02-00 222-13, Guro-Dong Guro-Gu Seoul Korea 152-053 http://www.ktl.re.kr Ref. Report No. 05 - 1341 – 013 Page 2 of 14 Korea Testing Laboratory Telecommunication Team 222-13, Guro3-dong, Guro-gu, Seoul Korea 152-848 TABLE OF CONTENTS I. GENERAL INFORMATION 3 1. Grantee’s Name and Mailing Address 2. Manufacturer's Name and Mailing Address 3. Equipment Descriptions 4. Rules and Regulations 5. Measuring Procedure 6. Place of Measurement 7. Date of Measurement . GENERAL REQUIREMENTS OF THE EUT 4 1. Labeling Requirement (Section 15.19) 2. Information to User (Sections 15.21) 3. Special Accessories (Section 15.27) 4. Compliant Conditions (Section 15.231) . RADIATED EMISSION MEASUREMENT (Section 15.231) 6 1. Test Procedure 2. Photograph of the test configuration 3. Sample Calculation 4. Measurement Data . OCCUPIED BANDWIDTH MEASUREMENT (Section 15.231) 13 . TEST EQUIPMENTS USED FOR MEASUREMENT 14 Ref. Report No. 05 - 1341 – 013 Page 3 of 14 Korea Testing Laboratory Telecommunication Team 222-13, Guro3-dong, Guro-gu, Seoul Korea 152-848 . GENERAL INFORMATION 1. Grantee’s Name and : Youngshin Electronics Co., Ltd. Mailing Address 102-701, Bucheon Techno-park, 364, Samjeong-dong, Ojeong-gu, Bucheon-si, Kyungki-Do, 421-740 Korea 2. Manufacturer's Name and : Youngshin Electronics Co., Ltd. Mailing Address 102-701, Bucheon Techno-park, 364, Samjeong-dong, Ojeong-gu, Bucheon-si, Kyungki-Do, 421-740 Korea 3. Equipment Descriptions 3.1 Operating Frequency : 433.92 MHz 3.2 Type of Emission : Pulse Code Signal 3.3 Power Supply : DC 12 V (Battery) 4. Rules and Regulations : FCC Part 15, Subpart C 5. Measuring Procedure : ANSI C63.4-2003 6. Place of Measurement : Absorber-lined Room (KTL) 7. Date of Measurement 7.1 Conducted Emission : Not Applicable 7.2 Radiated Emission : May 10, 2005 Ref. Report No. 05 - 1341 – 013 Page 4 of 14 Korea Testing Laboratory Telecommunication Team 222-13, Guro3-dong, Guro-gu, Seoul Korea 152-848 . GENERAL REQUIREMENTS OF THE EUT 1. Labeling Requirement (Section 15.19) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interface, and (2) this device must accept any interference received, including interference that may cause undesired operation. 1.1 Location of Label : User’s Guide Manual 1.2 How Applied : Printed 2. Information to User (Section 15.21) The following or similar statements were provided in the manual for user instruction. Please refer page 1 of the attached manual for details. CAUTION : Any changes or modifications in construction of this device which are not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 3. Special Accessories (Section 15.27) 3.1 Were the special Accessories provided? [ ] yes, [ x ] no 3.2 If yes, details for the special accessories are as follows : 3.3 If yes, were the appropriate instructions provided on the first page of the text concerned with the installation of the device? [ ] yes, [ ] no 3.4 Are these accessories provided of the type which can be readily obtained from multiple retail outlets ? [ ] yes, [ ] no And therefore does the manual specify what additional components or accessories are required to used in order to comply with the Rules? [ ] yes, [ ] no Ref. Report No. 05 - 1341 – 013 Page 5 of 14 Korea Testing Laboratory Telecommunication Team 222-13, Guro3-dong, Guro-gu, Seoul Korea 152-848 4. Compliant Conditions (Section 15.231) 4.1 Was the EUT used for continuous transmissions, such as voice or video, and data transmission ? [ ] yes, [ x ] no 4.2 Was the EUT manually operated ? [ x ] yes, [ ] no If yes, did the EUT employ a switch that would automatically deactivate the transmitter within not more than 5 seconds of being released ? [ x ] yes, [ ] no 4.3 Was the EUT automatically activated ? [ ] yes, [ x ] no If yes, did the EUT cease transmission within 5 seconds after deactivation ? [ ] yes, [ ] no 4.4 Was the EUT used for periodic transmissions at regular predetermined intervals ? [ ] yes, [ x ] no Ref. Report No. 05 - 1341 – 013 Page 6 of 14 Korea Testing Laboratory Telecommunication Team 222-13, Guro3-dong, Guro-gu, Seoul Korea 152-848 . RADIATED EMISSION MEASUREMENT (Section 15.231) 1. Test Procedure 1.1 Preliminary Testing for Reference Preliminary testing was performed in a KTL absorber-lined room to determine the emission characteristics of the EUT. The EUT was placed on the wooden table which has dimensions of 0.8 meters in height, 1 meter in length and 1.5 meters in width. Receiving antenna (Biconi-Log antenna : 30 to 1000 MHz or Horn Antenna : 1 to 18 GHz) was placed at the distance of 1 meter from the EUT. An attempt was made to maximize the emission level with the various configurations of the EUT. Emission levels from the EUT with various configurations were examined on a spectrum analyzer connected with a RF amplifier and graphed by a plotter. 1.2 Final Radiated Emission Test at an Absorber-Lined Room The final measurement of radiated field strength was carried out in a KTL absorber-lined Room that was listed up at FCC according to the "Radiate…

Text truncated - open the document above for the full version.

Test Setup Photos

[Test Photo]

Contact Information

Applicant

Young II Chang(President)
[email protected]82-32-324-1110Fax: 82-32-324-1228

Test Firm

Korea Testing LaboratoryJeong-Min Kim
[email protected]82-2-860-1462Fax: 82-2-860-1468

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-

Other Applications from Youngshin Electronics Co., LTD.

Car alarm - FCC ID O44JMA510SS - Youngshin Electronics Co., LTD.
O44JMA510SS

Car alarm

Mar 27, 2007

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Car Alarm - FCC ID O44JMR600SS - Youngshin Electronics Co., LTD.
O44JMR600SS

Car Alarm

Mar 22, 2007

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Two Way Car Alarm System - FCC ID O44JMA580 - Youngshin Electronics Co., LTD.
O44JMA580

Two Way Car Alarm System

Sep 11, 2006

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Two Way Car Alarm System - FCC ID O44JMR5100 - Youngshin Electronics Co., LTD.
O44JMR5100

Two Way Car Alarm System

Sep 11, 2006

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Two Way Car Alarm System - FCC ID O44JMR540 - Youngshin Electronics Co., LTD.
O44JMR540

Two Way Car Alarm System

Sep 11, 2006

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver