Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
HRM1 Heart Rate Monitor Use Instructions Wearing the HRM1 Heart Rate Monitor Wear the HRM1 Heart Rate Monitor directly on your skin, slightly below your breastbone. Wetting both sensors on the back of the Heart Rate Monitor will result in optimum capture of heart rate pulses (wet with water or biogel). The strap should fit snugly enough to remain in place during your exercise session. Proper placement of the Heart Rate Monitor is also important for optimum capture of heart rate pulses. Pairing the HRM1 Heart Rate Monitor with a Sports Monitoring Watch The HRM1 Heart Rate Monitor must pair with an ANT-enabled Sports Monitoring Watch in order to display Heart Rate data to the user. To do this: • Bring the HRM1 Heart Rate Monitor within 10-30 inches (25-75cm) of the Sports Monitoring Watch • Be sure to stand at least 72 inches (183cm) away from any other ANT-enabled Heart Rate Monitor • You can be in proximity to other ANT-enabled devices • After the HRM1 Heart Rate Monitor pairs with the Sports Monitoring Watch, the heart rate icon should appear on the watch Specifications: Size (max dimensions): 347 x 42 x 22mm (W x H x D) Weight: 29g Strap: Detachable adjustable elastic strap, 425-641mm (L) Power: Single user-replaceable CR-2032 battery Battery life: 3 years assuming use of 1 hr/day at 20°C Storage temp: -20°C to +70°C Operating temp: -10°C to +50°C User-interface: Auto on/off RF frequency/protocol: 2.4 GHz / Dynastream ANT transmission protocol Communication range: > 3 m (receiver dependent) Regulatory compliance: FCC, IC, and CE ready Product Warnings and Important Information • The HRM1 is intended for home or office use • Always consult your physician before beginning or modifying any exercise program. If you have a pacemaker, defibrillator, or other electronic implanted device, consult your physician before using a heart rate monitor. • The heart rate monitor is not a medical device, and could suffer from interference from external electrical sources. The heart rate readings are for reference only and no responsibility can be accepted for the consequences of erroneous readings. • Contact your local waste department to properly dispose of the units and batteries. Do not incinerate. FCC Compliance This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Operational Conditions This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Declaration of Conformity Hereby, XXX decalares that this HRM product is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. To view the full Declaration of Conformity, see the XXX web site for your product: www.xxx.com/yyy (XXX to be customer name and yyy exact website location)
FCC ID: O6RSRHM1B Company: Dynastream Innovations, Inc. FCC ID: O6RSRHM1B Company: Dynastream Innovations, Inc.
D C B A A B C D 1 2 3 4 5 6 7 8 8 7 6 5 4 3 2 1 THE INFORMATIONCONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF DYNASTREAM INNOVATIONS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUTTHE DYNASTREAM INNOVATIONS IS PROHIBITED. DYNASTREAM INNOVATIONS 12 July 07 SHEET:1 OF 1 DATE: REV: 4 C OMMEN TS: PROPRIETARY AND CONFIDENTIAL TOPVIEW DRAWING NOT FOR PRODUCTION BATTERY DOOR - STAMPED GRAPHICS BACK PLATE - STAMPED GRAPHICS xxx BATTERY DOOR - TOOLED GRAPHICS (PER EXISTING TOOLING) BACK PLATE - SILKSCREENED GRAPHICS (LOCATIONS OF OPEN/CLOSETEST AND DOTS APPROXIMATE ONLY) OPEN CLOSE Date Code Stamped Here HRM1B - HEART RATE MONITOR Pb TITLE: HRM1B (Garmin) - Wireless Heart Rate Monitor FCC ID: O6RHRM1B IC: 3797A-HRM1B MADE IN CHINA - Do not scale drawing. - Garmin logo shown in top view to be pad printed directly on the plastic visibly, legibly, and indelibly with ink, color PANTONE 8402C - Markings on battery cover to be tooled into textured plastic, except for alignment arrow, which is to be stamped into the plastic. - Product/Certifications label, WEEE marks, “OPEN” position, “CLOSE” position, open position dot, and close position dot shown in bottom view to be pad printed on the plastic visibly, legibly, and indelibly with ink, color PANTONE 8402C
FCC ID: O6RHRM1B Company: Dynastream Innovations, Inc. FCC ID: O6RHRM1B Company: Dynastream Innovations, Inc.
Curtis-Straus LLC is accredited to ISO/IEC 17025 by A2LA for the specific scope of accreditation under Certificate Number 1627-01. This report may contain data which is not covered by the A2LA accreditation. See our scope of accreditation at the end of this test report. Any opinions or interpretations expressed in this report are outside the scope of our A2LA accreditation as A2LA only accredits testing. ____________________________________________________________ Curtis-Straus • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 page 1 of 18 Test Report Report No H0575-1 Client Dynastream Innovations Phone 403-932-9292 Fax 403-932-6521 FRN 0008033557 Models HRM1B, A-661-200-040 FCC ID O6RHRM1B IC 3797A-HRM1B Equipment Type Low Power Communication Device Transmitter Equipment Code DXX Emissions Designator K1D Tested To FCC 15.249 and RSS 210 Issue 7, RSS-GEN Issue 2 Results As detailed within this report Prepared by David Harris – Test Engineer Authorized by Michael Buchholz – EMC Manager Issue Date 8/2/07 Conditions of issue This Test Report is issued subject to the conditions stated in the ‘Conditions of Testing’ section on page 17 of this report. REPORT: EH0575-1 FCC ID: O6RHRM1B IC ID: 3797A-HRM1B ____________________________________________________________ Curtis-Straus • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 Page 2 of 18 Summary ...........................................................................................................3 Test Methodology..............................................................................................3 Instrument Bandwidth Settings: .....................................................................4 EUT Configuration.............................................................................................5 Statement of Conformity....................................................................................6 Test Data and Plots...........................................................................................7 Section 15.249...............................................................................................8 Section 15.249 (d) .........................................................................................9 Occupied BW...............................................................................................10 AC Line Conducted Emission Measurements..............................................12 Test Equipment Used......................................................................................13 Conditions Of Testing......................................................................................17 REPORT: EH0575-1 FCC ID: O6RHRM1B IC ID: 3797A-HRM1B ____________________________________________________________ Curtis-Straus • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 Page 3 of 18 Summary This report is an application for certification of a transmitter operating under 47 CFR 15.249 of the FCC rules and RSS-210 Issue 7 and RSS GEN Issue 2 provided for operation in the frequency band of 2434MHz ~ 2465Mhz. The product covered by this report is the MultiHRM MN HRM1B. Dynastream Innovations has requested an additional model number that will be used by their customers so that they may sell the HRM1B under their name. The product that will be sold by this customer will be electrically identical to the one sold by Dynastream Innovations. The only difference will be the artwork and the model number placed on the device when it is manufactured. The additional name and model number is as follows. Name: Cosmed Wireless HR Monitor Number: A-661-200-040 Test Methodology All testing was performed according to the procedures specified in ANSI C63.4 (2003). The product was tested with modulation on and peak readings were compared against the QP limit (below 1000MHz) presented in section CFR 15.249. Frequency range investigated: 30MHz – 25GHz Measurement Distance: Frequency (MHz) Distance (m) Comments Fundamental (2434MHz ~ 2465Mhz) 3 m Radiated 30MHz – 18GHz except 2434MHz ~ 2465Mhz band 3m Radiated Spurious Measurements 18GHz-25GHZ .3m Radiated Spurious Measurements The EUT was fully maximized. EUT was tested in 3 orthogonal axis in order to maximize the emissions. The product has multiple channels of operation and was evaluated at the lowest, highest, and middle channel. Fresh batteries were used during the testing. The product is DC powered and derives its power from a battery. All readings are peak unless otherwise noted. REPORT: EH0575-1 FCC ID: O6RHRM1B IC ID: 3797A-HRM1B ____________________________________________________________ Curtis-Straus • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 Page 4 of 18 Instrument Bandwidth Settings: Fundamental Reading: RBW 1MHz VBW 3MHz Spurious Readings (below 30 MHz- 1000 MHz): RBW 120 KHz VBW 300 KHz Spurious Readings (above 1000 MHz): RBW 1 MHz VBW 3 MHz REPORT: EH0575-1 FCC ID: O6RHRM1B IC ID: 3797A-HRM1B ____________________________________________________________ Curtis-Straus • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828 Page 5 of 18 EUT Configuration EUT Configuration Work Order: H0575 Company: Dynastream Innovations Inc. Company Address: 228 River Ave. Cochrane, Alberta T4C2C1 Contact: Curtis Stafford MNSN EUT: HRM1B1 EUT Description: Heart Rate Monitor EUT Max Fre quency: 2465MHz Support Equipment: MNSN HRM Sensitivity jigN/AN/A(in house diag device) HRM ClampN/AN/A(in house diag device) EUT Cables: QtyShielded?LengthFerrites None Unpopulated EUT Ports: QtyReason None Software / Operating Mode Description: Different samples of the EUT provide both normal and "constant on" operation at high, low, and mid channels. The Sensitivity jig and clamp are used to artificially stimulate the EUT during immunity testing and also spurious emissions testing. REPORT: EH0575-1 FCC ID: O6RHRM1B IC ID: 3797A-HRM1B __________…
Text truncated - open the document above for the full version.
FCC ID: O6RHRM1B Company: Dynastream Innovations, Inc. FCC ID: O6RHRM1B Company: Dynastream Innovations, Inc. FCC ID: O6RHRM1B Company: Dynastream Innovations, Inc. FCC ID: O6RHRM1B Company: Dynastream Innovations, Inc. FCC ID: O6RHRM1B Company: Dynastream Innovations, Inc.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.43 GHz - 2.46 GHz | - |

N5
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
LOW POWER TRANSMITTER (2400-2483.5)
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
LOW POWER TRANSMITTER (2400-2483.5 MHz)
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
LOW POWER TRANSMITTER (2400-2483.5 MHz)
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
LOW POWER TRANSMITTER (2400-2483.5 MHz)
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter