1 Mount the Reader Installation and User Instructions for S680 & S690 Readers You can remove the front cover by easing it off gently with a screwdriver at this point 2 Reader Connections Note: (For UL Listed Products) 1). Consult local AHJ (Authority Having Jurisdiction) when installing access control readers and locking mechanisms to any portal in an egress path. 2). The use of Fail Closed / secure configuration shall be determined by local building codes and the local AHJ. 3). Wiring methods shall be in accordance with NEC (National Electrical Code) ANSI/NFPA 70. 4). All Interconnected devices must be UL listed. 5). For UL294 Installations the S680 and S690 Readers have only been determined compatible to be used with the M2150 Series Control and Elevator Units. You should find that the backplate has holes for connection to most standard electrical back boxes. The S680 and S690 readers are readers that are capable of reading HID format card, with LED’s. The readers use For additional information regarding the installation, configuration and proper use of this product please refer to: M2150 Design Guide, P/N 9600-0420 Issue 1.6.4 or later and SMS Software User Guide, P/N 9600-0429 Issue 7.0.4 or later. 125kHz proximity card ® 20mA current loop communications. Mount the backplate using countersunk headed screws adjacent to the opening edge of the door. Presentthe cardface-ontothereaderuntilyouhear a"bleep". The reader is now working correctly. Cardscan be presented in rapid succession; there is no need, for example, to wait for "GREEN LED’s" to disappear before presenting another. When faulted, the reader can not accept a card read. Check wiring for faults or replace reader. 9600-0199. Installation and User Instructions for S680/690 Readers, Issue 2.0x1 5th November 2013. G4S Technology, 2013. FCC Notice: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any unauthorized modification to this device may void the authority of the user to operate it. All trademarks acknowledged. © LED Status Indicator GREEN – The lock is released and you may open the door. RED – You do not have access rights to gain entry, or the reader did not read your card properly (in this case, present it again). Specifications Input voltage: 12Vdc. Input current: 100mA Max. Operating temperature: -13 to 158°F (-25 to 70°C) Operating humidity: 90%, non-condensing. Maximum read range: 4" (100mm). Approvals: EN300330, EN301489 4 Using / Testing the Reader 3 Reader Connections contd. TX- RX+ RX- 680/690 Reader 20mA current loop Connect shield at controller end only. Shielded Belden 9537 7x24 awg cable UL Listed style 2464 (DUZX) cable. Maximum distance 150m 12V 0V TX+ RX- TX+ TX- 12V 0V RX+ Controller Note: Brown wire not used Red Black Green Orange White Blue
Serial Label Position 42 mm 124mm
S680 MK II READER TECHNICAL DESCRIPTION OF OPERATION The S680 MKII HID Proximity Reader’s intended purpose is to read identification codes programmed into passive transponders and display a response on one of two LEDs. The maximum read range is about 5.5”. The unit is intended to be connected by cable to a range of Access Control Controllers which provide the necessary power and control/interface signals. The circuitry is contained on a single PCB which is mounted and potted in a plastic enclosure (50mm x 130mm x 25mm approx). A cable from PCB exits through the back of the unit. The power supply is a nominal 12V DC and linear regulators are used to provide 5V internal supply rails. The antenna is a coil that emits a 125KHz magnetic field. The field ‘powers up’ a passive transponder which is brought into the vicinity of the antenna. When powered this operates as a field disturbance device allowing two-way communication to take place between the reader and the card. The field is pulsed continuously and a dedicated device that is manufactured by the HID corporation for the purpose carries out modulation of the field. The control processor handles communications between the reader and the controller, responding to commands received and passing card data and status information back to the controller.
Radio Test Report for G4S Technology Ltd on S680 Document No: TRA-012532-47-03-A Total number of pages: 35 TRaC Wireless Test Report : TRA-012532-47-03-A Applicant : G4S Technology Ltd Apparatus : S680 Specification(s) : CFR47 Part 15.209, July 2011 Purpose of Test : Certification FCC ID : OE5S680A Authorised by : Radio Products Manager Issue Date :18 th November 2013 Authorised Copy Number : PDF TRaC Global Test Report: TRA-012532-47-03-A 3 Contents Section 1: Introduction 4 1.1 General 4 1.2 Tests Requested By 5 1.3 Manufacturer 5 1.4 Apparatus Assessed 5 1.5 Test Result Summary 6 1.6 Notes relating to the assessment 7 1.7 Deviations from Test Standards 7 Section 2: Measurement Uncertainty 8 2.1 Measurement Uncertainty Values 8 Section 3: Modifications 10 3.1 Modifications Performed During Assessment 10 Appendix A: Formal Emission Test Results 11 A1 Transmitter Intentional Emission Radiated 12 A2 Radiated Spurious Emissions 13 A3 Power Line Conducted Emissions 19 Appendix B: Supporting Graphical Data 21 C1 Test samples 26 C2 EUT operating mode during testing 27 C3 EUT Configuration Information 28 C4 List of EUT Ports 29 C5 Details of Equipment Used 30 Appendix D: Additional Information 31 Appendix E: Photographs and Figures 32 TRaC Global Test Report: TRA-012532-47-03-A 4 Section 1: Introduction 1.1 General This report contains an assessment of an apparatus against Electromagnetic Compatibility Standards based upon tests carried out on samples submitted to the Laboratory. Test performed by: TRaC Global [ ] Unit E South Orbital Trading Park Hedon Road Hull, HU9 1NJ. United Kingdom. Telephone: +44 (0) 1482 801801 Fax: +44 (0) 1482 801806 TRaC Global [X] Unit 1 Pendle Place Skelmersdale West Lancashire, WN8 9PN United Kingdom Telephone: +44 (0) 1695 556666 Fax: +44 (0) 1695 577077 Email: [email protected] Web site: http://www.tracglobal.com Tests performed by: S Hodgkinson Report author: S Hodgkinson This report must not be reproduced except in full without prior written permission from TRaC Global Ltd. TRaC Global Test Report: TRA-012532-47-03-A 5 1.2 Tests Requested By This testing in this report was requested by: G4S Technology Ltd Challenge House International Drive Tewkesbury GL20 8UQ Gloucestershire, UK 1.3 Manufacturer Same as above 1.4 Apparatus Assessed The following apparatus was assessed between 30 th October and 4 th November 2013 S680 The above equipment is an RFID card reader with a radio transmitter operating at 125.3 kHz. TRaC Global Test Report: TRA-012532-47-03-A 6 1.5 Test Result Summary Full details of test results are contained within Appendix A. The following table summarises the results of the assessment. The statements relating to compliance with the standards below apply ONLY as qualified in the notes and deviations stated in sections 1.6 to 1.7 of this test report. Full details of test results are contained within Appendix A. The following table summarises the results of the assessment. Test Type Regulation Measurement standard Result Spurious Emissions Radiated <1000MHz Title 47 of the CFR: Part 15 Subpart (c) 15.209 ANSI C63.10 Pass Spurious Emissions Radiated >1000MHz Title 47 of the CFR: Part 15 Subpart (c) 15.209 ANSI C63.10 Pass AC Power conducted emissions Title 47 of the CFR: Part 15 Subpart (c) 15.207 ANSI C63.10 Pass Intentional Emission Frequency Title 47 of the CFR: Part 15 Subpart (c) 15.209 ANSI C63.10 Pass Intentional Emission Field Strength Title 47 of the CFR: Part 15 Subpart (c) 15.209 ANSI C63.10 Pass Intentional Emission Band Occupancy Title 47 of the CFR: Part 15 Subpart (c) 15.209 ANSI C63.10 Pass Intentional Emission ERP (mW) Title 47 of the CFR: Part 15 Subpart (c) 15.209 ANSI C63.10 Pass Unintentional Radiated Spurious Emissions Title 47 of the CFR: Part 15 Subpart (b) 15.109 ANSI C63.10 Pass Antenna Arrangements Integral: Title 47 of the CFR: Part 15 Subpart (c) 15.203 - N/A Antenna Arrangements External Connector Title 47 of the CFR: Part 15 Subpart (c) 15.204 - N/A Restricted Bands Title 47 of the CFR: Part 15 Subpart (c) 15.205 - N/A Maximum Frequency of Search Title 47 of the CFR: Part 15 Subpart (c) 15.33 - N/A Extrapolation Factor Title 47 of the CFR: Part 15 Subpart (c) 15.31(f) - N/A Abbreviations used in the above table: CFR : Code of Federal Regulations ANSI : American National Standards Institution REFE : Radiated Electric Field Emissions PLCE : Power Line Conducted Emissions TRaC Global Test Report: TRA-012532-47-03-A 7 1.6 Notes relating to the assessment With regard to this assessment, the following points should be noted: The results contained in this report relate only to the items tested and were obtained in the period between the date of initial receipt of samples and the date of issue of the report. The apparatus was set up and exercised using the configurations, modes of operation and arrangements defined in this report only. Particular operating modes, apparatus monitoring methods and performance criteria required by the standards tested to have been performed except where identified in Section 1.7 of this test report (Deviations from Test Standards). For emissions testing, throughout this test report, “Pass” indicates that the results for the sample as tested were below the specified limit (refer also to Section 2, Measurement Uncertainty). Where relevant, the apparatus was only assessed using the monitoring methods and susceptibility criteria defined in this report. All testing with the exception of testing at the Open Area Test Site was performed under the following environmental conditions: Temperature : 17 to 23 °C Humidity : 45 to 75 % All dates used in this report are in the format dd/mm/yy. This assessment has been performed in accordance with the requirements of ISO/IEC 17025. 1.7 Deviations from Test Standards There were no deviations from the standards tested to. TRaC Global Test Report: TRA-012532-47-03-A 8 Section 2: Measurement Uncertainty 2.1 Measurement Uncertainty Values For the test data recorded …
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.1253 MHz - 0.1253 MHz | - |

Proximity card reader with keypad for access control systems
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Access Control Keypad Reader 884 MKII
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Smartcard reader with keypad for access control systems 874 MKII
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
S884O Proximity Reader
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
S884B Proximity Reader
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter