Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
AEI PROTECT-ON SYSTEMS LIMITED www.apo-hk.com VERSION: 05/2013 Self-Contained Access Control Reader AR-2808 User Manual TABLE OF CONTENTS INTRODUCTION SPECIFICATIONS Package Contents THE FRONT PANEL Status Indicator (Blue) Operation Indicators Card Reader Window Door Bell Button (Function Selector) INSTALLATION Precautions for Installation Location Precautions for Accidental Short Circuit Precautions for Electric Spikes & Back EMF THE CONNECTION TERMINALS 1 - 2 : 12VDC (Power Input Terminal) 3 : (+) 12V Power Supply for The Lock 4 : (-) Power Supply for The Lock (Output Contact for Door Lock Strike) 5 : EG IN (Egress Input for N.O. Button) 6 : Data I/O Port 7 - 8 : Door Bell (Relay Contact for Optional Door Chime) 9 - 10 : Tamper Switch (Tamper Switch with N.C. Contact) CREATE A MASTER CARD (CMC) The First Step before Programming - Make A Madter Card Procedures of Creating A New Master Card with CMC Jumper PROGRAMMING 1) Criteria for Setting System to Programming Mode 2) Use The Master Card to Set System into Programming Mode for The 5 Feature Groups 3) The Reading Manner for Master Card 4) Audible Indications in Programming & Operation I ) RECORD USER CARD(S) – Feature Group 1 II ) DELETE USER CARD(S) – Feature Group 2 III ) SET OUTPUT MODE FOR DOOR LOCK -- Feature Group 3 IV ) SET SYSTEM SAFETY LOCK-UP -- Feature Group 4 V ) CREATE / DELETE SUPER USER CARD(S) -- Feature Group 5 OPERATION FEATURE SETTING PROCEDURES SUMMARY CHART APPLICATION EXAMPLES 1) Stand Alone Access Control Electric Lock 2) Application Hints for The Auxiliary Terminals APPLICATION EXPANSION – The Optional Auxiliary Reader AR-2802 Multi- Station Access Control Electric Lock ...................................................................................................................... 3 ................................................................................................................... 3 ................................................................................................................ 3 ................................................................................................................ 4 .......................................................................................................... 4 ............................................................................................................. 4 ............................................................................................................ 4 ...................................................................................... 4 ........................................................................................................................ 5 ...................................................................................... 5 ................................................................................ 5 .......................................................................... 5 ............................................................................................. 6 .................................................................................... 6 .................................................................................. 6 ................................ 6 ................................................................................ 7 ..................................................................................................................... 7 ..................................................... 7 .................................................... 7 .......................................................................................... 8 .................................................... 8 .............................................. 8 ....................................................................................................................... 9 ............................................................... 9 .. 9 ................................................................................. 9 ................................................................ 9 ................................................................... 10 .............................................................. 11-12 ........................................... 13 ...................................................... 14 ................................. 15-16 .............................................................................................................................. 17 ................................................. 18-19 ..................................................................................................... 20 ......................................................................... 20 ..................................................................... 20 ............................. 21 ............................................................................ 22 2 SPECIFICATIONS INTRODUCTION 3 AR-2808 is a self-contained access control reader designed to drive electric door lock directly. It accommodates up to 500 proximity EM cards and its output is compatible with the Fail-safe and Fail-secure electric locks. The door lock striking time is programmable. A built-in door chime relay contact is also available to operate an external low power door chime. It is a full feature compact reader ideally for the access control system in small office and home applications. The system employs solid state switch instead of relay contact for door lock strike. It gives longer service life and prevents the sabotage of opening the door with strong magnet. AR-2808 is built-in with Data I/O bus for system expansion. Maximum three optional card readers (AR-2802) can be connected with it to make a multi-station access control system. ● Operation Voltage: 12VDC Nominal, 11-16VDC ● Operating Current: 60mA (quiescent), 80mA Maximum ● Operation Temperature: -20°C to +70°C ● Environmental Humidity: 5-95% Relative Humidity, Non-conden…
Text truncated - open the document above for the full version.
SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 4.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Revised wording (obsolete) 1.0 2.0 Sept–25-2007 Updated company template (obsolete) 2.0 3.0 Jan-31-2012 Updated letter information (current) 3.0 4.0 May-23-2014 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 4.0 AEI Protect-On Systems Limited 2014-08-04 To: SIEMIC, INC. 775 Montague Expressway, Milpitas, CA 95035 USA Dear Sir/Madam, Re: Product Certification Representative Authorization Letter We, AEI Protect-On Systems Limited. hereby authorize SIEMIC, Inc. to act as a Certification Body for certifying for the following project(s): Product Description: Self-Contained Access Control Reader Model name: AR-2808 FCC ID: OGJ-AR2808 Sincerely, Client’s signature :CHIU KWOK Client’s name / title:GENERAL MANAGER Contact information / address :(852) 2428 5273 (Flat B, 4/F., Effort Industrial Building, 2-8 Kung Yip Street, Kwai Chung, N.T. Hong Kong)
SCS-F19: Confidentiality Request Letter Page 1 of 2 Rev 3.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Confidentiality Request Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 (obsolete) 1.0 2.0 August – 11 - 2008 Updated company template & Added text box (current) 2.0 3.0 Jan-31-2012 SCS-F19: Confidentiality Request Letter Page 2 of 2 Rev 3.0 AEI Protect-On Systems Limited 2014-08-07 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Subject: Permanent Confidentiality Request for FCC ID: OGJ-AR2808 We hereby request confidential treatment of information accompanying this application as outlined below: - Block Diagram - Operational Description - Schematic The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Client’s signature :CHIU KWOK Client’s name / title:GENERAL MANAGER Contact information / address :(852) 2428 5273 (Flat B, 4/F., Effort Industrial Building, 2-8 Kung Yip Street, Kwai Chung, N.T. Hong Kong)
Antenna
Report No.: ATE20141501 Page 1 of 14 FCC ID: OGJ-AR2808 ACCURATE TECHNOLOGY CO., LTD APPLICATION FOR VERIFICATION On Behalf of AEI Protect-On Systems Limited Self-Contained Access Control Reader Model No.: AR-2808 FCC ID: OGJ-AR2808 Prepared for : AEI Protect-On Systems Limited Address : Flat B, 4/F., Effort Industrial Building, 2-8 Kung Yip Street,HongKong Prepared by : Accurate Technology Co., Ltd. Address : F1, Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park, Nanshan District, Shenzhen 518057, P.R. China Tel: +86-755-26503290 Fax: +86-755-26503396 Report No. : ATE20141501 Date of Test : Aug 04-12,2014 Date of Report : Aug 12,2014 Report No.: ATE20141501 Page 2 of 14 FCC ID: OGJ-AR2808 ACCURATE TECHNOLOGY CO., LTD TABLE OF CONTENTS Description Page Test Report Declaration 1. TEST RESULTS SUMMARY......................................................................................................... 4 2. GENERAL INFORMATION............................................................................................................ 5 2.1. Description of Device (EUT).................................................................................................................5 2.2. Special Accessory and Auxiliary Equipment......................................................................................5 2.3. Description of Test Facility...................................................................................................................6 2.4. Measurement Uncertainty.....................................................................................................................6 3. POWER LINE CONDUCTED MEASUREMENT......................................................................... 7 3.1. For Power Line Conducted Emission..................................................................................................7 3.2. Power Line Conducted Emission Measurement Limits (Class B)..................................................7 3.3. Power Line Conducted Emission Measurement Results.................................................................7 4. RADIATED EMISSION MEASUREMENT................................................................................... 8 4.1. For Radiated Emission Measurement................................................................................................8 4.2. TEST CONFIGURATION......................................................................................................................8 4.3. Block Diagram of Test Setup...............................................................................................................9 4.4. Radiated Emission Limit.......................................................................................................................9 4.5. EUT Configuration on Measurement..................................................................................................9 4.6. Operating Condition of EUT...............................................................................................................10 4.7. Test Procedure.....................................................................................................................................10 4.8. Radiated Emission Noise Measurement Result..............................................................................10 5. ANTENNA REQUIREMENT........................................................................................................ 14 5.1. The Requirement.................................................................................................................................14 5.2. Antenna Construction..........................................................................................................................14 Report No.: ATE20141501 Page 3 of 14 FCC ID: OGJ-AR2808 ACCURATE TECHNOLOGY CO., LTD Test Report Declaration Applicant& address : AEI Protect-On Systems Limited Flat B, 4/F., Effort Industrial Building, 2-8 Kung Yip Street,HongKong Manufacturer& address : AEI Protect-On Systems Limited Flat B, 4/F., Effort Industrial Building, 2-8 Kung Yip Street,HongKong Product : Self-Contained Access Control Reader Model No. : AR-2808 Trade name : / Measurement Procedure Used: FCC Rules and Regulations Part 15 Subpart C 15.207&15.209 FCC/ANSI C63.4-2009 The device described above is tested by Accurate Technology Co., Ltd. to determine the maximum emission levels emanating from the device. The maximum emission levels are compared to the FCC Part 15 Subpart C limits both radiated and conducted emissions. The measurement results are contained in this test report and Accurate Technology Co., Ltd. is assumed full responsibility for the accuracy and completeness of these measurements. Also, this report shows that the Equipment Under Test (EUT) is to be technically compliant with the FCC requirements. This report applies to above tested sample only. This report shall not be reproduced in part without written approval of Accurate Technology Co., Ltd. Date of Test : Aug 04-12,2014 Date of Report : Aug 12,2014 Prepared by : (Eric, Engineer) Approved & Authorized Signer : ( Sean, Manager) Report No.: ATE20141501 Page 4 of 14 FCC ID: OGJ-AR2808 ACCURATE TECHNOLOGY CO., LTD 1. TEST RESULTS SUMMARY Test Items Test Standard Test Results Power Line Conducted Emission FCC Part 15.207 N/A Radiated Emission FCC Part 15.209 Pass Report No.: ATE20141501 Page 5 of 14 FCC ID: OGJ-AR2808 ACCURATE TECHNOLOGY CO., LTD 2. GENERAL INFORMATION 2.1.Description of Device (EUT) The submitted sample is a Self-Contained Access Control Reader. The sample is powered by DC 12V. Self-Contained Access Control Reader Frequency : 125KHz Number of Channels : 1 Modulation Type : GFSK Type of Antenna : Internal Antenna Max antenna gain : 0dBi Power Supply : DC 12V 2.2.Special Accessory and Auxiliary Equipment N/A Report No.: ATE20141501 Page 6 of 14 FCC ID: OGJ-AR2808 ACCURATE TECHNOLOGY CO.…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.125 MHz - 0.125 MHz | - |

Auxiliary Card Reader
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
SPLIT-DECODED ACCESS CONTROLLER
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
ACCESS CONTROLLER
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Remote Control Keyfob
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Wireless Digital Keypad
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter