Operation Description 12429 (49M) R/C Power Boss The transmitter operates at 49.860MHz, in which is controlled by a crystal. It is powered by 9V battery. There are two-control sticks on the transmitter. When the forward control trigger is pushed / pulled once, a radio frequency control signal will be transmitted to the receiver for going forward/backward. When the left and right sticks are pushed once, a radio frequency will be transmitted to the receiver for going left/right.
TEST REPORT Report No. : AG024813-001 Date : 2006 October 04 Page 1 of 11 FCC ID: OGM12429TX-49 This document shall not be reproduced except in full or with written approval by the laboratory. CMA Industrial Development Foundation Limited Room 1302, Yan Hing Centre, 9-13 Wong Chuk Yeung St.., Fo Tan, Shatin, Hong Kong. Tel: (852) 2698 8198 Fax: (852) 2695 4177 E-mail: [email protected] Web Site: http://www.cmatcl.com Application No. : LG220908(0) Applicant : Enertec Enterprises Ltd. Room 1017, Chinachem Golden Plaza, 77 Mody Road, Tsim Sha Tsui East, Kowloon, Hong Kong Sample Description : One(1) submitted sample(s) stated to be R/C Power Boss of Model No. 12429 Ref. No.: 12419 Radio Frequency : 49.860 MHz Transmitter Rating : 1 x 9V size battery No. of submitted sample : Two (2) piece(s) *** Date Received : 2006 September 08 Test Period : 2006 September 11 β 2006 September 21 Test Requested : FCC Part 15 Certification. Test Method : 47 CFR Part 15 (10-1-05 Edition) ANSI C63.4 β 2003 Test Result : See attached sheet(s) from page 2 to 11. Conclusion : The submitted sample was found to comply with requirement of FCC Part 15 Subpart C. For and on behalf of CMA Industrial Development Foundation Limited Authorized Signature : ____________________________________________________ Danny Chui Deputy Manager - EL. Division TEST REPORT Report No. : AG024813-001 Date : 2006 October 04 Page 2 of 11 FCC ID: OGM12429TX-49 This document shall not be reproduced except in full or with written approval by the laboratory. CMA Industrial Development Foundation Limited Room 1302, Yan Hing Centre, 9-13 Wong Chuk Yeung St.., Fo Tan, Shatin, Hong Kong. Tel: (852) 2698 8198 Fax: (852) 2695 4177 E-mail: [email protected] Web Site: http://www.cmatcl.com Table of Contents 1 General Information............................................................................................................................. 3 1.1 General Description ..................................................................................................................... 3 1.2 Location of the test site ................................................................................................................ 4 1.3 List of measuring equipment........................................................................................................ 5 2 Description of the radiated emission test ............................................................................................. 6 2.1 Test Procedure ............................................................................................................................. 6 2.2 Test Result ................................................................................................................................... 6 2.3 Radiated Emission Measurement Data ........................................................................................ 7 3 Description of the Line-conducted Test............................................................................................... 8 3.1 Test Procedure ............................................................................................................................. 8 3.2 Test Result ................................................................................................................................... 8 3.3 Graph and Table of Conducted Emission Measurement Data ..................................................... 8 4 Photograph ........................................................................................................................................... 9 4.1 Photographs of the Test Setup for Radiated Emission and Conduction Emission....................... 9 4.2 Photographs of the External and Internal Configurations of the EUT......................................... 9 5 Supplementary document................................................................................................................... 10 5.1 Bandwidth .................................................................................................................................. 10 5.2 Duty cycle .................................................................................................................................. 10 5.3 Transmission time ...................................................................................................................... 10 6 Appendices......................................................................................................................................... 11 TEST REPORT Report No. : AG024813-001 Date : 2006 October 04 Page 3 of 11 FCC ID: OGM12429TX-49 This document shall not be reproduced except in full or with written approval by the laboratory. CMA Industrial Development Foundation Limited Room 1302, Yan Hing Centre, 9-13 Wong Chuk Yeung St.., Fo Tan, Shatin, Hong Kong. Tel: (852) 2698 8198 Fax: (852) 2695 4177 E-mail: [email protected] Web Site: http://www.cmatcl.com 1 General Information 1.1 General Description The equipment under test (EUT) is a transmitter for R/C Power Boss. It operates at 49.860MHz which is controlled by a crystal. The EUT is powered by 1 x 9V size battery and it has two control sticks in the EUT. When the control stick pushed once, it can transmit different radio control signal to receiver. The brief circuit description is listed as follows: - Y1, Q2 and associated circuit act as oscillator - Q1 and associated circuit act as RF amplify - IC1 and associated circuit act as encoder TEST REPORT Report No. : AG024813-001 Date : 2006 October 04 Page 4 of 11 FCC ID: OGM12429TX-49 This document shall not be reproduced except in full or with written approval by the laboratory. CMA Industrial Development Foundation Limited Room 1302, Yan Hing Centre, 9-13 Wong Chuk Yeung St.., Fo Tan, Shatin, Hong Kong. Tel: (852) 2698 8198 Fax: (852) 2695 4177 E-mail: [email protected] Web Site: http://www.cmatcl.com 1.2 Location of the test site Radiated emisβ¦
Text truncated - open the document above for the full version.
Job No.: _______________ WF-EL-EMC-15 Edition 1 2006 April 12 Page of Bandwidth Plot Bandwidth 1
Job No.: _______________ WF-EL-EMC-15 Edition 1 2006 April 12 Page of Duty Cycle Duty Cycle 1 Duty Cycle 2 Job No.: _______________ WF-EL-EMC-15 Edition 1 2006 April 12 Page of Duty Cycle 3
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 49.86 MHz - 49.86 MHz | - |

Shelby RC
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
RC Toy Transmitter
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
RC Toy Transmitter
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
RC Toy Receiver
Equipment Class
CRR - Superregenerative Receiver
RC Toy Transmitter Steel Monster
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter