FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Junlan Electronic Ltd/
  3. OKUBS2607

OKUBS2607Smart Tag

Shenzhen Junlan Electronic Ltd
Smart Tag - FCC ID OKUBS2607 - Shenzhen Junlan Electronic Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 18, 2024
Application Purpose
Original Equipment
Date of Application
Aug 18, 2024
Equipment Note
Smart Tag
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Junlan Electronic Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Smart Tag MODEL:BS-2607 FCC Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. Note: The Grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. such modifications could void the user's authority to operate the equipment. The device has been evaluated to meet general RF exposure requirement. To maintain compliance with FCC's RF exposure guidelines, the distance must be at least 20 cm between the radiator and your body, and fully supported by the operating and installation. Safety Instructions a) Remove and immediately recycle or dispose of used batteries according to local regulations and keep away from children. Do NOT dispose of batteries in household trash or incinerate. b) Even used batteries may cause severe injury or death. c) Call a local poison control center for treatment information. d) The compatible battery type is CR2032 3V. e) Non-rechargeable batteries are not to be recharged. f) Do not force discharge, recharge, disassemble, heat above 50°C/122° or incinerate. Doing so may result in injury due to venting, leakage or explosion resulting in chemical burns. g) Ensure the batteries are installed correctly according to polarity (+ and -). h) Do not mix old and new batteries, different brands or types of batteries, such as alkaline, carbon-zinc, or rechargeable batteries. i) Remove and immediately recycle or dispose of batteries from equipment not used for an extended period of time according to local regulations. j) Always completely secure the battery compartment. If the battery compartment does not close securely, stop using the product, remove the batteries, and keep them away from children. WARNING ●INGESTION HAZARD: This product contains a button cell or coin battery. ●DEATH or serious injury can occur if ingested. ●A swallowed button cell or coin battery can cause Internal Chemical Burns in as little as 2 hours. ●KEEP new and used batteries OUT OF REACH of CHILDREN. ●Seek immediate medical attention if a battery is suspected to be swallowed or inserted inside any part of the body. NO OBVIOUS SYMPTOMS: Unfortunately it is not obvious when a button or coin battery is stuck in a child's oesophagus(food pipe). There are no specific symptoms associated with this. The child might: 1.Appear to have an upset stomach or virus; 2.Cough, gag or drool a lot; 3.Be sick; 4.Point to their abdomen or throat; 5.Be tired or lethargic; 6.Be quieter or more clingy than usual or otherwise "not themselves"; 7.Lose their appetite or have reduced appetite; and 8.Not want to eat solid food/ be unable to eat solid food. These sorts of symptoms vary or fluctuate, with the pain increasing and then subsiding. Another possible symptom of button and coin battery ingestion is vomiting fresh (bright red) blood. If the child does this seek immediate medical help. The lack of clear symptoms is why it is important to be vigilant with "flat" or spare button or coin batteries in the home and the products that contain them. 1 Welcome Thank you for choosing this product. We believe great products should be innovative, attractive, and affordable. Our products have been carefully designed to be great at what they do and work straight out of the box – and this one is no exception. Please read this manual carefully before using this product for you own safety. 2 Smart Tag 2.1 In the box Carefully remove the unit from the packaging. Inside the box you will find: • Smart Tag including CR2032 coin battery • Keyring • Battery cover key • User Manual 2.2 Front and back view Speaker Power On/Off and Function button Battery compartment A B C A B C 3 Quick Setup 3.1 Remove the battery film Smart Tag battery has a film to isolate it during shipping, this film must be removed before use. CR2032 3V 1.Remove the battery cover with the key provided 2 .Take out the battery 3.Remove the battery film Once the film has been removed replace the battery (positive ‘+’ side up) and replace the cover. Your Smart Tag is now ready for use. 3.2 Power On/Off 1. Short press the Function button to Power On. Audible beeps will sound. 2. Long press the Function button to Power Off. An audible double beep will sound. Note: If there is no response when pressing the Function button, please press the Function button twice in succession and you will hear a beep, it means the Smart Tag is powered on. 3.3 Apple Find My App 1. On your Apple iPhone, iPad, Apple Watch or iMac update to the latest version of iOS. 2. Allow notifications from the App. 3.4 Connect your Smart Tag 1. Power on your Smart Tag. 2. Within the Find My App, select the ‘Items’ tab and tap ‘Add item’, followed by ‘Other Supported item’…

Text truncated - open the document above for the full version.

Attestation Statements

Rev1/26/2023 ShenzhenJunlanElectronicLtd FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:06-21-2024 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:OKUBS2607 ShenzhenJunlanElectronicLtd(“theapplicant”)certifiesthattheequipmentforwhichauthorizationis soughtisnot“covered”equipmentprohibitedfromreceivinganequipmentauthorizationpursuantto section2.903oftheFCCrules. Sincerely, (Applicantsignature) pengxiao Rev1/26/2023 ShenzhenJunlanElectronicLtd FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:06-21-2024 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:OKUBS2607 ShenzhenJunlanElectronicLtd(“theapplicant”)certifiesthat,asofthedateofthefilingofthe application,theapplicantisnotidentifiedontheCoveredListasanentityproducing“covered” equipment.Theapplicantisnotanamedentityoranyofitssubsidiariesoraffiliates. Sincerely, (Applicantsignature) pengxiao

Attestation Statements

ShenzhenJunlanElectronicLtd No.277PingKuiRoad,ShijingCommunity,PingshanOffice,PingshanNewDistrict, Shenzhen China Date:June21,2024 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 FCCID:OKUBS2607 FRN:0021880893 USAgent–AttestationStatement/Part2.911(d)(7) ShenzhenJunlanElectronicLtdcertifies,thatasofJune21,2024,wehavedesignatedFCCUS Agent,LLCtoacceptserviceofprocessonourbehalfforFCCID:OKUBS2607 ShenzhenJunlanElectronicLtd,acceptstomaintainanagentofserviceofprocessintheUnited Statesfornolessthanoneyearaftereitherthegranteehaspermanentlyterminatedallmarketing andimportationoftheapplicableequipmentwithintheU.S.,ortheconclusionofanyCommission- relatedadministrativeorjudicialproceedinginvolvingtheequipment,whicheverislater. FCCUSAgent,LLC,acceptsasofthedateofthefilingofthisapplication,theobligationofbeing thedesignatedagentforthepurposeofacceptingserviceofprocessonbehalfofShenzhen JunlanElectronicLtdforFCCID:OKUBS2607 DesignatedAgentInformation: CompanyName:FCCUSAgent,LLC FRN:0033402884 Address:3722IllinoisAvenue,SaintCharles,IL,60174,USA ContactPerson:TimPayne Phone:708-571-3148 Email:[email protected] Sincerely, Company:ShenzhenJunlanElectronicLtdDesignatedAgent:FCCUSAgent,LLC CompanyRepresentative:pengxiaoDesignatedAgentRepresentative:TimPayne Signature:Signature:

Cover Letter(s)

ShenzhenJunlanElectronicLtd Date:June21,2024 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 FCCID:OKUBS2607 ToWhomItMayConcern: ThisletteristostatementthatBS-2607series,BS-2607XX(XXmeansunitcolor,itcanbeAtoZ orN/A)/SmartTag.hasbeentestedaccordingtoFCCPart15BbyWaltekTestingGroupCo., Ltd.(TestReportNo.:WTH24D06143822W001).AndtheSDOCfile,meettingtherequirementsof theFCCregulations,wouldbeenprovidedwhenthedeviceissoldbytheresponsiblepartyinUS. TheservicewillnotbesolduntiltheSDOCisprovided.IfthesaledoesnothaveanSDOC,all responsibilityistheresponsibilityoftheapplicant. Sincerely, Signature [pengxiao] [safetyengineer] [ShenzhenJunlanElectronicLtd]

Cover Letter(s)

ShenzhenJunlanElectronicLtd Date:June21,2024 FederalCommunicationsCommission AuthorizationandEvaluationDivision ConfidentialityRequestregardingapplicationforcertificationofFCCID:OKUBS2607 PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequestconfidential treatmentofinformationaccompanyingthisapplicationasoutlinedbelow: ExhibitTypeFileName Long-termconfidentiality: Schematics BlockDiagram OperationalDescription Schematics.pdf BlockDiagram.pdf OperationalDescription.pdf Theabovematerialscontaintradesecretsandproprietaryinformationnotcustomarilyreleasedto thepublic.Thepublicdisclosureofthesematerialsmaybeharmfultotheapplicantandprovide unjustifiedbenefitstoitscompetitors. TheapplicantunderstandsthatpursuanttoSection0.457oftheRules,disclosureofthis applicationandallaccompanyingdocumentationwillnotbemadebeforethedateoftheGrant forthisapplication. Sincerely, ShenzhenJunlanElectronicLtd Signature pengxiao/safetyengineer TypednameandTitle

Cover Letter(s)

ShenzhenJunlanElectronicLtd FCCID:OKUBS2607 POWEROFATTORNEY Date:June21,2024 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 ToWhomItMayConcern: We,theundersigned,herebyauthorizeWaltekTestingGroupCo.,Ltd.(DevalQin) onourbehalf,toapplytotheFederalCommunicationsCommissiononour equipment.AnyandallactscarriedoutbyWaltekTestingGroupCo.,Ltd.(Deval Qin)onourbehalfshallhavethesameeffectasactsofourown.This authorizationexpiresonJune20,2025. Sincerely, ShenzhenJunlanElectronicLtd Signature pengxiao/safetyengineer TypednameandTitle

External Photos

Appendix-BS-2607-Photos Page 3 of 8 2. Photographs –Constructional Details 2.1. EUT – External View Model BS-2607 FCC ID: OKUBS2607 Appendix-BS-2607-Photos Page 4 of 8 Appendix-BS-2607-Photos Page 5 of 8

ID Label/Location Info

serial number serial number Model: BS-2607 FCC ID: OKUBS2607 1 x 3V CR2032 Made in China CoolGray 6C CoolGray 6C 8.5*8.5mm engraving Model: BS-2607 FCC ID: OKUBS2607 1 x 3V CR2032 Made in China

Internal Photos

Appendix-BS-2607-Photos Page 6 of 8 2.2. EUT – Internal View Model BS-2607 FCC ID: OKUBS2607 Appendix-BS-2607-Photos Page 7 of 8 Appendix-BS-2607-Photos Page 8 of 8 Ant.

RF Exposure Info

Waltek Testing Group Co., Ltd. http://www.waltek.com.cn Page 1 of 8 TEST REPORT Referen ce No. .................... : WTH24D06143822W003 FCC ID ................................ : OKUBS6407 Applicant ............................ : Shenzhen Junlan Electronic Ltd Address .............................. : No.277, PingKui Road, Shijing Community, Pingshan Office, Pingshan New District, Shenzhen, China Manufacturer .................... : Shenzhen Junlan Electronic Ltd Address .............................. : No.277, PingKui Road, Shijing Community, Pingshan Office, Pingshan New District, Shenzhen, China Product ............................... : Smart Tag Model(s). ............................ : BS-2607, BS-2607XX(XX means unit color, it can be A to Z or N/A) Standards........................... : FCC 47CFR Part 2 Subpart J Section 2.1091 Date of Receipt sample .... : 2024-06-21 Date of Test ....................... : 2024-06-21 to 2024-07-25 Date of Issue ...................... : 2024-08-12 Test Result ......................... : Pass Remarks: The re sults shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Testing Group Co., Ltd. Address: No. 77, Houjie Section, Guantai Road, Houjie Town, Dongguan City, Guangdong, China Tel: +86-769-2267 6998 Fax: +86-769-2267 6828 Compiled by: Approved by: James Cheng / Project Engineer Deval Qin / Designated Reviewer Reference No.: WTH24D06143822W003 Page 2 of 8 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 2. Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2. CONTENTS ............................................................................................................................................................ 2 3. REVISION HISTORY ............................................................................................................................................ 3 4. GENERAL INFORMATION .................................................................................................................................. 4 4.1. GENERAL DESCRIPTION OF E.U.T. ............................................................................................................ 4 4.2. DETAILS OF E.U.T. ..................................................................................................................................... 4 4.3. TEST FACILITY ............................................................................................................................................ 5 4.4. SUBCONTRACTED ....................................................................................................................................... 5 4.5. ABNORMALITIES FROM STANDARD CONDITIONS ....................................................................................... 5 5. TEST SUMMARY .................................................................................................................................................. 6 6. RF EXPOSURE ...................................................................................................................................................... 7 6.1. REQUIREMENTS .......................................................................................................................................... 7 6.2. THE PROCEDURES / LIMIT ........................................................................................................................... 7 6.3. MPE CALCULATION METHOD .................................................................................................................... 8 6.4. RADIO FREQUENCY RADIATION EXPOSURE EVALUATION ......................................................................... 8 Reference No.: WTH24D06143822W003 Page 3 of 8 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 3. Revision History Test Report No. Date of Receipt Sample Date of Test Date of Issue Purpose Comment Approved WTH24D06143822W003 2024-06-21 2024-06-21 to 2024-07-25 2024-08-12Original - Valid Reference No.: WTH24D06143822W003 Page 4 of 8 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 4. General Information 4.1. General Description of E.U.T. Product: Smart Tag Model(s): BS-2607, BS-2607XX(XX means unit color, it can be A to Z or N/A) Model Description: Only the model names and colors are different. Model BS-2607 was tested in the report. Test Sample No.: 1-1/1 Bluetooth Version: 5.2 Hardware Version: V1 Software Version: 1.7.25 4.2. Details of E.U.T. Operation Frequency: 2402~2480MHz Max. RF output power: 1M: 0.27dBm, 2M: 0.33dBm Modulation Technology: GFSK Antenna installation: PCB Antenna Antenna Gain: -0.08dBi Note: #: The antenna gain is provided by the applicant, and the applicant should be responsible for its authenticity, WALTEK lab has not verified the authenticity of its information. Ratings: DC 3V Reference No.: WTH24D06143822W003 Page 5 of 8 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 4.3. Test Facility The test facility has a test site registered with the following organizations: ISED CAB identifier: CN0013. Test Firm Registration No.: 7760A. Waltek Testing Group Co., Ltd. Has been registered and fully described in a report filed with the Industry Canada. The acceptance letter from the Industry Canada is maintained in our files. Registration number 7760A, October 15, 2016. FCC Designation No.: CN1201. Test Firm Registration No.: 523476. Waltek Testing Group Co., Ltd. EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. Registration number 523476,…

Text truncated - open the document above for the full version.

Test Report

Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China GENERAL INFORMATION 1.1 Test Environment Condition Ambient Temperature 19 to 25 °C Ambient Relative 45 to 55 % Humidity Ambient Pressure N/A (Not applicable) 1.2 Announce (1) The test report is invalid if not marked with the signatures of the persons responsible for preparing and approving the test report. (2) The test report is invalid if there is any evidence and/or falsification. (3) The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. (4) This document may not be altered or revised in any way unless done so and all revisions are duly noted in the revisions section. (5) Content of the test report, in part or in full, cannot be used for publicity and/or promotional purposes without prior written approval from the laboratory. Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China PRODUCT INFORMATION 2.1 Applicant Applicant Lenze Technology Co.,LTD Address d.c., 26c newspaper west tower, 6008 shennan Avenue, Futian District , Contact Person Tony Telephone Number +86 0755-82031775;25332530 Fax Number +86 0755-82713604 E-mail Address [email protected] 2.2 Manufacturer Manufacturer Lenze Technology Co.,LTD Address d.c., 26c newspaper west tower, 6008 shennan Avenue, Futian District , Shenzhen City, Guangdong Province, China Contact Person N/A Telephone Number N/A Fax Number N/A E-mail Address N/A 2.3 General Description for Equipment under Test (EUT) EUT Type Bluetooth Antenna Model Name PCB Antenna Antenna Type PCB Antenna Hardware Version N/A Serial Number N/A Dimensions N/A 2.4 Technical Information Frequency Range 2400MHz~ 2500MHz Test Frequencies 2402MHz, 2441MHz, 2480MHz Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China SUMMARY OF TEST RESULTS 3.1 Test Standards No. Identity Document Title 1 IEEE149-1979 IEEE Standard Test Procedures for Antennas 3.2 Test Verdict Report Section Description Remark ANNEX A.1 Gain And Efficiency -- ANNEX B Radiation Pattern -- 3.3 Test Uncertainty The uncertainty is calculated using the methods suggested in the "Guide to the Expression of Uncertainty in Measurement" (GUM) published by ISO. Item Uncertainty VSWR(S11) 0.4 Gain -0.08dBi Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China GENERAL TEST CONFIGURATIONS 4.1 Test Condition Environment Parameter Selected Values During Tests Temperature Voltage Relative Humidity Normal Temperature, Normal Voltage 25°C N/A 51% (NTNV) 4.2 Test Equipment List Description Manufacturer Model Serial No. Cal. Date Cal. Due Vector Network Agilent E5071C MY46103472 2014.09.07 2015.09.06 Analyzer 5*5*5 Full Anechoic SATIMO 5*5*5 N/A 2014.09.05 2015.09.04 Chamber SG24 Multi-probe Antenna Measurement SATIMO SG24-L 1101855-0001 2014.10.25 2015.10.24 System 4.3 Test Setup Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China ANNEX A TEST RESULTS A.1 Gain and Efficiency Frequency Gain (dBi) Efficiency (%) 2402MHz -0.08 0.99 2441MHz -0.21 1.06 2480MHz -0.18 1.12 ANNEX B RADIATION PATTERN 3DPattern 2402MHZ 0 -1 -3 -6 -15 -30 Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China 2402MHZ 1D Radiation Pattern PHI =0 Phi=0 freq=2402MHz 0 -1 -3 -6 -15 -30 Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China PHI =90 THETA = 90 Phi=90 freq=2402MHz Theta=90 freq=2402MHz Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China ANNEX C TEST SETUP PHOTO ANNEX D EUT PHOTO Antenna shape

Test Report

Waltek Testing Group Co., Ltd. http://www.waltek.com.cn Page 1 of 38 TEST REPORT Referen ce No. .................... : WTH24D06143822W002 FCC ID ................................ : OKUBS2607 Applicant ............................ : Shenzhen Junlan Electronic Ltd Address .............................. : No.277, PingKui Road, Shijing Community, Pingshan Office, Pingshan New District, Shenzhen, China Manufacturer .................... : Shenzhen Junlan Electronic Ltd Address .............................. : No.277, PingKui Road, Shijing Community, Pingshan Office, Pingshan New District, Shenzhen, China Product ............................... : Smart Tag Model(s). ............................ : BS-2607, BS-2607XX(XX means unit color, it can be A to Z or N/A) Standards........................... : FCC 47CFR Part 15.247 Date of Receipt sample .... : 2024-06-21 Date of Test ....................... : 2024-06-21 to 2024-07-25 Date of Issue ...................... : 2024-08-12 Test Result ......................... : Pass Remarks: The re sults shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Testing Group Co., Ltd. Address: No. 77, Houjie Section, Guantai Road, Houjie Town, Dongguan City, Guangdong, China Tel: +86-769-2267 6998 Fax: +86-769-2267 6828 Compiled by: Approved by: James Cheng / Project Engineer Deval Qin / Designated Reviewer Reference No.: WTH24D06143822W002 Page 2 of 38 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 2 Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2 CONTENTS ............................................................................................................................................... 2 3 REVISION HISTORY ................................................................................................................................. 3 4 GENERAL INFORMATION ....................................................................................................................... 4 4.1 General Description of E.U.T. ....................................................................................................... 4 4.2 Details of E.U.T. ............................................................................................................................ 4 4.3 Channel List .................................................................................................................................. 4 4.4 Test Facility ................................................................................................................................... 5 4.5 Subcontracted ............................................................................................................................... 5 4.6 Abnormalities from Standard Conditions ...................................................................................... 5 4.7 Test Mode ..................................................................................................................................... 5 5 TEST SUMMARY ...................................................................................................................................... 6 6 EQUIPMENT USED DURING TEST ......................................................................................................... 7 6.1 Equipments List ............................................................................................................................ 7 6.2 Description of Support Units ......................................................................................................... 7 6.3 Measurement Uncertainty ............................................................................................................ 8 6.4 Test Equipment Calibration .......................................................................................................... 8 7 DUTY CYCLE ............................................................................................................................................ 9 8 RADIATED EMISSIONS ......................................................................................................................... 10 8.1 EUT Operation ............................................................................................................................ 10 8.2 Test Setup .................................................................................................................................. 11 8.3 Spectrum Analyzer Setup ........................................................................................................... 12 8.4 Test Procedure ........................................................................................................................... 13 8.5 Corrected Amplitude & Margin Calculation ................................................................................ 13 8.6 Summary of Test Results ........................................................................................................... 14 9 CONDUCTED SPURIOUS EMISSIONS ................................................................................................. 20 9.1 Test Procedure ........................................................................................................................... 20 9.2 Test Result .................................................................................................................................. 21 10 BAND EDGE MEASUREMENT .............................................................................................................. 27 10.1 Test Produce .................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Appendix-BS-2607-Photos Page 1 of 8 1. Test Setup photos Model BS-2607 FCC ID: OKUBS2607 1.1 Photograph – Radiated Emissions For 9kHz-30MHz Test Site 2# For 30MHz-1000MHz Test Site 2# Appendix-BS-2607-Photos Page 2 of 8 For Above 1GHz Test Site 1#

Contact Information

Applicant

peng xiao(safety engineer)
[email protected]0755-27309169Fax: 0755-27309497

Test Firm

WALTEK TESTING GROUP CO., LTD.Joy Zhou
[email protected]0769-22676998

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.08 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter device.

Other Applications from Shenzhen Junlan Electronic Ltd

Retro Bluetooth Turntable - FCC ID OKUJP2326 - Shenzhen Junlan Electronic Ltd
OKUJP2326

Retro Bluetooth Turntable

Sep 07, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Smart Finder - FCC ID OKUBS6207S - Shenzhen Junlan Electronic Ltd
OKUBS6207S

Smart Finder

Sep 01, 2026

Equipment Class

DTS - Digital Transmission System
STEREO - FCC ID OKUBS2708EC - Shenzhen Junlan Electronic Ltd
OKUBS2708EC

STEREO

May 15, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
BLUETOOTH TURNTABLE - FCC ID OKUJC9021 - Shenzhen Junlan Electronic Ltd
OKUJC9021

BLUETOOTH TURNTABLE

Apr 27, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
STEREO - FCC ID OKUBS2708CA - Shenzhen Junlan Electronic Ltd
OKUBS2708CA

STEREO

Apr 17, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter