Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
EXHIBIT C User Manual Copyright & Regulatory Information This manual and software described in it are copyrighted with all rights reserved. This manual may not be copied, in whole or in part, without written consent. All product names are trademarks and or registered trademarks of their respective companies. FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measure: - Reorient or relocated the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into a different outlet circuit from than the receiver. - Consult an experienced radio/TV technician for help. CAUTION: Any changes of modifications not expressly approved by the grantee of this device could void the users authority to operate the equipment.
EXHIBIT E Block Diagram
From: trc168 [[email protected]] Sent: Thursday, November 15, 2001 7:09 PM To: Mike Kuo Subject: Fw: Globlink Technology Inc., FCC ID:OR7GL3688, Assessment no:AN01T1554 Dear Mike: Did you receive this E-mail sent on 13th. How is the status ? My customer is asking me again and again . Sorry ! Best Regards TRC Jacob Lin ----- Original Message ----- From: trc168 <[email protected]> To: Mike Kuo <[email protected]> Sent: Tuesday, November 13, 2001 10:21 AM Subject: Re: Globlink Technology Inc., FCC ID:OR7GL3688, Assessment no:AN01T1554 > Dear Mike : > > Sorry for my misunderstanding. > Attached file illustrated the function of the device. > Hope can be accepted. > > If no further problem, please speed up this case , > Because my client is quite upset. > > Thank you ! > > TRC > Jacob Lin > > ----- Original Message ----- > From: Mike Kuo <[email protected]> > To: 'trc168' <[email protected]> > Sent: Tuesday, November 13, 2001 10:03 AM > Subject: RE: Globlink Technology Inc., FCC ID:OR7GL3688, Assessment > no:AN01T1554 > > > > Dear Jacob: > > > > Your answer to question #2 is not acceptable. Requested information is > > operational description as required under section 2.1033(b)(4) of FCC > Rules > > not the measurement procedure as you indicated in your e-mail. > > > > Best Regards > > > > Mike Kuo > > > > -----Original Message----- > > From: trc168 [mailto:[email protected]] > > Sent: Monday, November 12, 2001 12:22 AM > > To: Mike Kuo > > Subject: Re: Globlink Technology Inc., FCC ID:OR7GL3688, Assessment > > no:AN01T1554 > > > > > > Mike : > > > > Here are the required information : > > > > #1. Below 30MHz > > RBW=10KHz & VBW=10KHz > > Detector : AV > > 30MHz ~1GHz > > RBW=100KHz & VBW=100KHz > > Detector : QP > > > > #2 Below 30MHz > > <1> Set the Loop ANT. height 1m. ,Vertical ,and rotate the ANT > > to find the azimuth of the highest emission and record the > > reading. > > <2>Keep the ANT. azimuth and turn the EUT 360 degree and record > > the highest emission. > > <3>Raise the ANT to 2 meters and repeat set <1> <2>. > > <4>Change the ANT Horizontal and repeat <1> ~<3> > > <5>Record the most highest reading in test report. > > > > 30MHz~1GHz > > Please refer to page 6 of test report. > > > > Thank you for your attention ! > > Best Regards > > > > TRC > > Jacob Lin > > > > ----- Original Message ----- > > From: Mike Kuo <[email protected]> > > To: <[email protected]> > > Sent: Thursday, November 08, 2001 11:40 AM > > Subject: FW: Globlink Technology Inc., FCC ID:OR7GL3688, Assessment > > no:AN01T1554 > > > > > > > > > > > > > -----Original Message----- > > > From: CERTADM > > > Sent: Wednesday, November 07, 2001 6:03 PM > > > To: '[email protected]' > > > Subject: Globlink Technology Inc., FCC ID:OR7GL3688, Assessment > > > no:AN01T1554 > > > > > > > > > Notice_content > > > ------------- > > > Question #1: Please provide instrument settings used during Radiated > > > emission tests ( page 8 and 9 of test report). > > > > > > Question #2: Please provide Operational Description. > > > > > > Best Reards > > > > > > Mike Kuo / TCB Certifier > > > The items indicated above must be submitted before processing can > continue > > > on the above referenced application. Failure to provide the requested > > > information within 60 days of the original e-mail date may result in > > > application dismissal and forfeiture of the filing fee. Also, please > note > > > that partial responses increase processing time and should not be > > submitted. > > > Any questions about the content of this correspondence should be > directed > > to > > > the e-mail address listed below the name of the sender. > > > > > >
List of Exhibit EXHIBIT A Sample Label EXHIBIT B Test Report EXHIBIT C User Manual EXHIBIT D Circuit Diagram EXHIBIT E Block Diagram EXHIBIT F Photographs of EUT EXHIBIT A Sample Label LABEL Format: This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. FCC ID : OR7GL3688 Model No.: GL3688 LABEL Size: 35 X18 mm LABEL Position: LABEL
EXHIBIT F Photographs of EUT
EUT Technical Specification: Equipment Identification Trade Name GLOBLINK Model Number GL3688 System Configuration ( ) Narrow Band System ( X ) Wide Band System Temperature range Category III (indoor use), 0Β°C to +55Β°C Function Wireless Keyboard Designed to Convey Data Power Supply ( X ) Battery ( ) Adaptor Antenna Type ( X ) Internal ( ) Antenna Connector ( ) Integral Antenna Frequency Band Lower Limit: 26.96 MHz, Upper Limit: 27.28 MHz Channel Number 6 * Channel Spacing 25KHz Product Standard RF: ETSI 300-220-3 EMC: ETSI 300-489-3 Transmitter Specification Type of Modulation FSK Designation of Emission 1.12 x 10 -4 mW Transmit Power Class ( X ) 5a ( ) 7a ( ) 8 ( ) 9 ( )11 ( ) 12 Duty Cycle Class ( ) 1.<0.1% ( ) 2.<1% ( ) 3.<10% ( X ) Up to 100% Mode of Operation ( ) Duplex ( ) Simplex ( ) Periodic ( X ) Continuous Receiver Specification Receiver Class ( ) Class 1 ( ) Class 2 ( X ) Class 3 *This EUT has six channels (each with 16 ID): 1. 26.060 MHz 2. 27.085 MHz 3. 27.110 MHz 4. 27.110 MHz 5. 27.160 MHz 6. 27.185 MHz EUT Technical Specification:
EXHIBIT D Circuit Diagram
EXHIBIT B Test Report Test Report ------------------------------------------------------------------------------- 2/11 Report No.: G2815477 Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778 Contents Chapter 1 Introduction Description of EUT...................................................................................................................3 Configuration of Test Setup......................................................................................................4 Chapter 2 Peak Power Measurement (Frequency Band: 26.96 ~ 27.28) Test Setup..................................................................................................................................5 Test Procedure...........................................................................................................................5 Chapter 3 Radiated Emission Test Test Condition and Setup..........................................................................................................6 Radiated Test Placement...........................................................................................................7 Appendix A : Peak Power and Radiated test result.........................................................................................8 Appendix B : Band Edge of Measurement.....................................................................................................10 Test Report ------------------------------------------------------------------------------- 3/11 Report No.: G2815477 Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778 Chapter 1 Introduction Description of EUT: This wireless keyboard with track ball use advanced transmission technology to allow comfortable use. However, occasionally outside sources may cause interference. The EUT power by two 1.5VDC batteries. *This EUT has six channels (each with 16 ID): 1. 27.060 MHz 2. 27.085 MHz 3. 27.110 MHz 4. 27.135 MHz 5. 27.160 MHz 6. 27.185 MHz Test method: All measurements contained in this report were performed according to the techniques described in Measurement procedure ANSI C63.4 β 1992. Pretest was found that the emission of operating mode is worse than standby mode. So, The final test is made at the operating mode. While testing, the EUT was made to transmit continuously and adjusted at a position, which transmitted the maximum emission. The test placement as the photographs showed is the worst case emission placed. (If the emission is close to the ambient, the resolution BW and view resolution will be reduced and the data will be recorded by detection of maximum hold peak mode.) The testing configuration of test setup is showing in the next page. Test Report ------------------------------------------------------------------------------- 4/11 Report No.: G2815477 Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778 Configuration of Test Setup EUT: Put two AAA size, 1.5V battery into the battery cell of EUT, powers the subject device. The EUT does not be connected with any product. EUT (Tx) Test Report ------------------------------------------------------------------------------- 5/11 Report No.: G2815477 Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778 Chapter 2 Peak Power Measurement (Frequency Band: 26.96 ~ 27.28) Test Setup: 1. Test Setup: 2. Test Procedure: a. The EUT was setup in the anechoic chamber as shown above. b. The loop antenna was located upon its plane vertical, 3-meter distance from the EUT. The center of the loop is 1-meter above the ground plane. c. In order to find the maximum radiation, the EUT was rotated 360Β°. The measuring antenna was rotated about its axis at each azimuth about the EUT. List of test Instrument : Calibration Date Instrument Name Model No. Brand Serial No. Last time Next time RECEIVER SCR3502 SCHAFFNER 210 12/01/00 12/01/01 Control Box TWR95-4 TRC C9001-2 12/01/00 12/01/01 Active Loop Antenna 6502 EMCO 2777 07/20/01 07/20/02 Open test side (Antenna, Amplify, cable calibrated together) 05/15/01 05/15/02 The level of confidence of 95% , the uncertainty of measurement of radiated emission is Β± 4.96 dB . Test Result : Appendix A EUT 1M 3M Spectrum Test Report ------------------------------------------------------------------------------- 6/11 Report No.: G2815477 Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778 Chapter 3 Radiated Emission Test Test Condition and Setup: Pretest : Prior to the final test ,the EUT is placed in an anechoic chamber, and scan from 30MHz to 1GHz. The devices rotated through three orthogonal axes to determine which attitude and configuration produces the highest emission relative to the limit. This is done to ensure the radiation exactly emits form the EUT. Final test: Final radiation measurements is made on a 3 β meter open-field test site. The EUT's maximum emission of radiation is placed on a nonconductive table, which is 0.8m height, the top surface is 1.0 x 1.5 meter. All placement is according to ANSI C63.4 - 1992. The emissions was examined from 30 MHz to 1000 MHz measured by receiver. The whole range Antenna is used to measure frequency from 30 MHz to 1 GHz. The final test is used the receiver. Measure more than six top marked frequencies generated form pretest by computer step by step at each frequency. The EUT is rotated 360 degrees, and antenna is raised and lowered from 1 to 4 meters to find the maximum emission levels. The antenna is used with both horizontal and vertical polarization. Appropriated preamplifier, which is made by TRC is used for improving sensitivity and precautions is taken to avoid overloading. The spectrum analyzerβs 6dB bandwidth is set to 120 KHz, and the EUT is measured at quasi-peak mode. If the emission is close to the frequency band of ambient, the tester will recheck the data and the corrected data will be written in the test data sheet. If the emission is just within the ambient, the data from shield room β¦
Text truncated - open the document above for the full version.
Test Report ------------------------------------------------------------------------------- 7/11 Report No.: G2815477 Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778 Radiated Test Placement: (Photographs)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 27.06 MHz - 27.185 MHz | - |

Wireless Ring Mouse
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Wireless Free Wheel Mouse
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Wireless Free Wheel Mouse
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Wireless Big Optical Trackball Mouse
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
2.4 GHz RF Wireless Optical Presentation Mouse
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter