
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Kyocera KX5 Slider Remix User Guide Draft The features of this handset are subject to modifications and may have changed since the printing of this document. ii User Guide for the Kyocera KX5 Slider Remix Phone This manual is based on the production version of the Kyocera KX5 phone. Software changes may have occurred after this printing. Kyocera reserves the right to make changes in technical and product specifications without prior notice. The products and equipment described in this documentation are manufactured under license from QUALCOMM Incorporated under one or more of the following U.S. patents: 4,901,307 5,109,390 5,267,262 5,416,797 5,506,865 5,544,196 5,657,420 5,101,501 5,267,261 5,414,796 5,504,773 5,535,239 5,600,754 5,778,338 5,228,054 5,337,338 5,710,784 5,056,109 5,568,483 5,659,569 5,490,165 5,511,073 The Kyocera Wireless Corp. (“KWC”) products described in this manual may include copyrighted KWC and third party software stored in semiconductor memories or other media. Laws in the United States and other countries preserve for KWC and third party software providers certain exclusive rights for copyrighted software, such as the exclusive rights to distribute or reproduce the copyrighted software. Accordingly, any copyrighted software contained in the KWC products may not be modified, reverse engineered, distributed or reproduced in any manner not permitted by law. Furthermore, the purchase of the KWC products shall not be deemed to grant either directly or by implication, estoppel, or otherwise, any license under the copyrights, patents or patent applications of KWC or any third party software provider, except for the normal, non-exclusive royalty- free license to use that arises by operation of law in the sale of a product. Kyocera is a registered trademark of Kyocera Corporation. Doodler and Race 21 are trademarks of Kyocera Wireless Corp. Tetris is a registered trademark of Elorg Company LLC. QUALCOMM is a registered trademark of QUALCOMM Incorporated. Openwave is a trademark of Openwave Systems Incorporated. eZiText is a registered trademark of Zi Corporation. All other trademarks are the property of their respective owners. Copyright © 2005 Kyocera Wireless Corp. All rights reserved. Ringer Tones Copyright © 2000-2002 Kyocera Wireless Corp. 82-M8529-1EN, Rev. X4 FCC/IC Notice This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. To maintain compliance with FCC RF exposure guidelines, if you wear a handset on your body, use the Kyocera Wireless Corp. (KWC) supplied and approved case CV90-G2573-01 and holster CV90-G2958-01. Other accessories used with this device for body-worn operations must not contain any metallic components and must provide at least 25 mm separation distance including the antenna and the user’s body. THIS MODEL PHONE MEETS THE GOVERNMENT’S REQUIREMENTS FOR EXPOSURE TO RADIO WAVES. Your wireless phone is a radio transmitter and receiver. It is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by the Federal Communications Commission of the U.S. Government. These limits are part of comprehensive guidelines and establish permitted levels of RF energy for the general population. The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to assure the safety of all persons, regardless of age and health. The exposure standard for wireless mobile phones employs a unit of measurement known as the Specific User Guide for the Kyocera KX5 Slider Remix Phoneiii Absorption Rate, or SAR. The SAR limit set by the FCC is 1.6 W/kg.* Tests for SAR are conducted using standard operating positions specified by the FCC with the phone transmitting at its highest certified power level in all tested frequency bands. Although the SAR is determined at the highest certified power level, the actual SAR level of the phone while operating can be well below the maximum value. This is because the phone is designed to operate at multiple power levels so as to use only the power required to reach the network. In general, the closer you are to a wireless base station antenna, the lower the power output. Before a phone model is available for sale to the public, it must be tested and certified to the FCC that it does not exceed the limit established by the government-adopted requirement for safe exposure. The tests are performed in positions and locations (e.g., at the ear and worn on the body) as required by the FCC for each model. Body-worn measurements differ among phone models, depending upon availability of accessories and FCC requirements. While there may be differences between the SAR levels of various phones and at various positions, they all meet the government requirement for safe exposure. The FCC has granted an Equipment Authorization for this model phone with all reported SAR levels evaluated as in compliance with the FCC RF emission guidelines. SAR information on this model phone is on file with the FCC and can be found under the Display Grant section http://www.fcc.gov/oet/fccid after searching on the FCC ID: OVFKWC-KX5. Additional information on SAR can be found on the Cellular Telecommunications and Internet Association (CTIA) web-site at http://www.wow-com.com. * In the United States and Canada, the SAR limit for mobile phones used by the public is 1.6 watts/kg (W/ kg) averaged over one gram of tissue. The standard incorporates a substantial margin of safety to give additional protection for the public and to account for any variations in measurements. Caution The user is cautioned that changes or modifications not expressly approve…
Text truncated - open the document above for the full version.
This document is generated in response to the queries asked in the e-mail from Compliance Certification Services titled “Kyocera Wireless Corp, FCC ID: OVFKWC-KX5, Assessment NO.: AN05T4754, Notice#1”. The queries asked in the e-mail received by Lin Lu on 10 th of May 2005 are listed below followed by the responses for each of the questions. Subject: Kyocera Wireless Corp, FCC ID: OVFKWC-KX5, Assessment NO.: AN05T4754, Notice#1 Date: Tue, 10 May 2005 13:51:37 -0700 From: "Mike Kuo" <[email protected]> To: <[email protected]>, <[email protected]> Cc: "Fernando Calimbahin" <[email protected]> Hi Lin : Please address the following issues: Question #1 On page 20/21/24-27/34/35/38/39 of radiated emission test report, there are several peak readings are over the average limits. Please provide average readings to demonstrate compliance. Question #2: 1900 CDMA body worn SAR plots with multiple hot spots, please provide secondary hot spot readings per OET 65C requirements. Question #3: Please confirm that by removing the battery, the FCC ID label can be visible by the user manual without using a tool. Question #4: The RF conducted output power listed in section 4 of operation description, the output power listed is much higher than the measured RF conducted output power and the output power used in the SAR evaluation. In addition, in the tune up procedures does not specify the factory rated output power. Please explain the differences in term of RF conducted output power. Question #5:In the request for confidentiality letter, SAR test report, SAR test plots , Part 22.24 test report and radiated test report are requested as short term confidential document. It is FCC policy that all test reports have to be available at the time of certification for public disclosure. Only user manual, test setup photos, external photos and internal photos can be granted as short term confidential document. Please review your request letter and move any sensitive photos from the test reports. FYI: Please enlarge/ increase resolution on your SAR plots. It is very difficult to view all the detail information on the SAR plots. The items indicated above must be submitted before processing can continue on the above referenced application. Failure to provide the requested information within 30 days of the original e-mail date may result in application dismissal and forfeiture of the filing fee. Also, please note that partial responses increase processing time and should not be submitted. Any questions about the content of this correspondence should be directed to the e-mail address listed below the name of the sender. Best Regards Mike Kuo Compliance Certification Services 561F Monterey Road Morgan Hill CA 95037 Tel: (408)463-0885 x: 105 Fax: (408)463-0888 http://www.ccsemc.com Question #1: On page 20/21/24-27/34/35/38/39 of radiated emission test report, there are several peak readings are over the average limits. Please provide average readings to demonstrate compliance. In the radiated emissions tests conducted by Nemko USA, Inc (San Diego, USA.), the peak readings reported on pages 20/21/24-27/34/35/38/39 in the original document were noise floor measurements and no signal was observed at those frequencies. The radiated emissions report has been updated by Nemko USA with these changes and is sent as a separate attachment along with this response for your review. Question #2: 1900 CDMA body worn SAR plots with multiple hot spots, please provide secondary hot spot readings per OET 65C requirements. Based on OET 65C, all peaks within 2.0 dB of the highest peak identified by the interpolated data should be evaluated with a fine resolution volume scan to determine the highest one-gram average SAR. Therefore, the DASY 4 program was configured in such a way that all peaks within 2.0 dB of the highest peak, if there was, will be automatically evaluated. The configuration of DASY 4 program is shown below. ⇒ Area scan job - when an area scan measured all reachable points, it computed all of the field maxima found in the scan area, within a range of 2dB as specified in OET 65C, (see below for the config.). For the cases that multiple maximums were detected, the number of zoom scan could be increased accordingly. ⇒ Zoom scan – in a zoom scan, the maxim number of cubes to measure was set to 2 due to two peaks appearance on the preceding area scans in this application, (see below for the config.). If two peaks were within 2dB of the highest one, two zoom scans could perform to provide the evaluations with a fine resolution volume scan to determine the one-gram average SAR for both peaks. Per the request, all of the SAR tests included in the original submittal were checked. In all of cases, the secondary peak was less than the primary peak by more than 2 dB, and the software only did one cube scan for the primary peak evaluation. To prove that the secondary peak is indeed lower by more than 2 dB, we increased the range to 3 dB so that the DAISY 4 program picks up the secondary hot spot as an example. The results of this case are listed in the table below, which clearly shows that the difference is 10*log(0.39/0.222) = 2.45 dB. The SAR plots and the relevant equipment validations are shown in the following pages. Note the dipole and probe used in the measurement were the same as what were used for the original submittal, therefore all of the manufacture info has been included in the original files. Channel:600 Frequency (MHz):1880 CDMA 1900 BODY Conducted Power (dBm):22.14 SAR, 1g (W/kg) ConfigurationAccessories Test Position Flip Position Phone Position Primary Peak Secondary Peak KX5-5C1 w/ standard battery Kyocera Holster: (CV90-G2598-01) FlatClosed Face Down 0.3900.222 Since the secondary peak is lower than the primary peak by more than 2 dB in this application, the rest of secondary peak values for other cases are not reported in the response. Date/Time: 05/17/05 08:52:03 Test Laboratory: Kyocera KX5-5C1…
Text truncated - open the document above for the full version.
FCC ID: OVFKWC-KX5 Kyocera Wireless Corp. 1 May 18, 2005 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 Re:Request of Confidentiality for FCC ID: OVFKWC-KX5 To Whom It May Concern: Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules (CFR 47), Kyocera Wireless Corp (KWC) hereby requests confidential and treatment of information accompanying this Application. The materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. We are also requesting Short-Term Confidentiality as outlined in Public Notice DA 04-1705. This provision will give KWC Temporary Confidentiality of commercially sensitive information prior to product launch. The requested Confidential and Temporary Confidential exhibits are listed in table 1 below: Table 1. Confidential and Short-Term Confidential ExhibitDescription 1Operation Descriptions 2Block diagrams 3Schematics Confidential 4Parts Lists 5Instruction Manual 6External Photos Short-Term Confidential 7Internal Photos The Applicant understands that pursuant to Rule 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this Application. Sincerely, Lin Lu Lin Lu Engineer, Principal Kyocera Wireless Corp.
FCC ID: OVFKWC-KX5 External Photos Page 1 of 4 Model: KX5 Exhibit 7: OVFKWC-KX5 External Photos Slide-down Front and Back View FCC ID: OVFKWC-KX5 External Photos Page 2 of 4 Model: KX5 Slide-up Front and Back View FCC ID: OVFKWC-KX5 External Photos Page 3 of 4 Model: KX5 Slide-down Side View FCC ID: OVFKWC-KX5 External Photos Page 4 of 4 Model: KX5 Slide-up Side View
FCC ID: OVFKWC-KX5 Label Information Page 1 of 1 Model: KX5 Exhibit 6: OVFKWC-KX5 ID Label Label Format Label Location
FCC ID: OVFKWC-KX5 Internal Photos Page 1 of 5 Model: KX5 Exhibit 8: OVFKWC-KX5 Internal Photos FCC ID: OVFKWC-KX5 Internal Photos Page 2 of 5 Model: KX5 FCC ID: OVFKWC-KX5 Internal Photos Page 3 of 5 Model: KX5 FCC ID: OVFKWC-KX5 Internal Photos Page 4 of 5 Model: KX5 FCC ID: OVFKWC-KX5 Internal Photos Page 5 of 5 Model: KX5
FCC ID: OVFKWC-KX5 SAR Report Page 1 of 28 Model: KX5 SAR Test Report on Dual-Band Tri-mode AMPS/CDMA Cellular Phone FCC Part 22 & 24 Certification FCC ID:OVFKWC-KX5 MODEL:KX5 DATE:April 26, 2005 STATEMENT OF COMPLIANCE Kyocera Wireless Corp declares under its sole responsibility that the product, FCC ID: OVFKWC- KX5 to which this declaration relates, is in conformity with the appropriate General Population/Uncontrolled RF exposure standards, recommendations and guidelines. It also declares that the product was tested in accordance with the appropriate measurement standards, guidelines and recommended practices. Any deviations from these standards, guidelines and recommended practices are noted: NONE. Date of Test: April 6-20, 2005 Test performed by: Kyocera Wireless Corp 10300 Campus Point Drive San Diego, CA 92121 Report Prepared by:Fernando Calimbahin, Engineer Report Reviewed by:Lin Lu, Principal Engineer FCC ID: OVFKWC-KX5 SAR Report Page 2 of 28 Model: KX5 Table of Contents 1INTRODUCTION.......................................................................................................................................................................................4 2EQUIPMENT UNDER TEST (EUT)..........................................................................................................................................................4 3PRODUCT DESCRIPTION......................................................................................................................................................................5 4ACCESSORIES:.........................................................................................................................................................................................6 5SAR TEST RESULT SUMMARY............................................................................................................................................................7 5.1MAXIMUM RESULTS FOUND DURING SAR EVALUATION..........................................................................................................7 5.2HEAD CONFIGURATION....................................................................................................................................................................7 5.3BODY WORN CONFIGURATION (WITH KWC BODY WORN ACCESSORIES)..............................................................................8 5.4MEASUREMENT UNCERTAINTY.....................................................................................................................................................8 6TEST CONDITIONS.................................................................................................................................................................................9 6.1AMBIENT CONDITIONS.....................................................................................................................................................................9 6.2RF CHARACTERISTICS OF THE TEST SITE......................................................................................................................................9 6.3TEST SIGNAL, FREQUENCIES AND OUTPUT POWER...................................................................................................................9 6.4DEVICE TEST CONDITIONS...............................................................................................................................................................9 7DESCRIPTION OF THE TEST EQUIPMENT....................................................................................................................................10 7.1DOSIMETRIC SYSTEM......................................................................................................................................................................10 7.2ADDITIONAL EQUIPMENT NEEDED IN VALIDATION................................................................................................................10 7.3TISSUE STIMULANTS.......................................................................................................................................................................10 7.4PHANTOMS DESCRIPTION..............................................................................................................................................................11 7.5ISOTROPIC E-FIELD PROBE.............................................................................................................................................................11 8SYSTEM VALIDATION........................................................................................................................................................................12 9DESCRIPTION OF THE TEST PROCEDURE...................................................................................................................................13 9.1TEST POSITIONS...............................................................................................................................................................................13 9.1.1Initial Ear Position....................................................................................................................................................................13 9.1.2Cheek Position...........................................................................................................................................................................14 9.1.3Tilt Position................................................................................................................................................................................14 9.1.4Body Worn Configuration........................................................................................................................................................15 9.2SCAN PROCEDURES.................................................................................…
Text truncated - open the document above for the full version.
FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 1 of 10 Model: KX5 Appendix B-3: CDMA 1900 (Head) SAR Distribution Plots FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 2 of 10 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 3 of 10 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 4 of 10 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 5 of 10 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 6 of 10 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 7 of 10 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 8 of 10 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 9 of 10 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 10 of 10 Model: KX5
FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 1 of 10 Model: KX5 Appendix B-2: CDMA 800 (Head) SAR Distribution Plots FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 2 of 10 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 3 of 10 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 4 of 10 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 5 of 10 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 6 of 10 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 7 of 10 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 8 of 10 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 9 of 10 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 10 of 10 Model: KX5
FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 1 of 10 Model: KX5 Appendix B-1: AMPS (Head) SAR Distribution Plots FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 2 of 10 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 3 of 10 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 4 of 10 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 5 of 10 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 6 of 10 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 7 of 10 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 8 of 10 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 9 of 10 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 10 of 10 Model: KX5
FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 1 of 13 Model: KX5 Appendix B-4: AMPS, CDMA 800, CDMA 1900 (Body) SAR Distribution Plots FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 2 of 13 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 3 of 13 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 4 of 13 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 5 of 13 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 6 of 13 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 7 of 13 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 8 of 13 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 9 of 13 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 10 of 13 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 11 of 13 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 12 of 13 Model: KX5 FCC ID: OVFKWC-KX5 SAR Distribution Plots Page 13 of 13 Model: KX5
FCC ID: OVFKWC-KX5 Validation Test Plots Page 1 of 13 Model:KX5 Appendix A: Validation Test Plots FCC ID: OVFKWC-KX5 Validation Test Plots Page 2 of 13 Model:KX5 FCC ID: OVFKWC-KX5 Validation Test Plots Page 3 of 13 Model:KX5 FCC ID: OVFKWC-KX5 Validation Test Plots Page 4 of 13 Model:KX5 FCC ID: OVFKWC-KX5 Validation Test Plots Page 5 of 13 Model:KX5 FCC ID: OVFKWC-KX5 Validation Test Plots Page 6 of 13 Model:KX5 FCC ID: OVFKWC-KX5 Validation Test Plots Page 7 of 13 Model:KX5 FCC ID: OVFKWC-KX5 Validation Test Plots Page 8 of 13 Model:KX5 FCC ID: OVFKWC-KX5 Validation Test Plots Page 9 of 13 Model:KX5 FCC ID: OVFKWC-KX5 Validation Test Plots Page 10 of 13 Model:KX5 FCC ID: OVFKWC-KX5 Validation Test Plots Page 11 of 13 Model:KX5 FCC ID: OVFKWC-KX5 Validation Test Plots Page 12 of 13 Model:KX5 FCC ID: OVFKWC-KX5 Validation Test Plots Page 13 of 13 Model:KX5
FCC ID: OVFKWC-KX5 Dipole Calibration Parameters Page 1 of 19 Model: KX5 Appendix D: Dipole Calibration Parameters FCC ID: OVFKWC-KX5 Dipole Calibration Parameters Page 2 of 19 Model: KX5 FCC ID: OVFKWC-KX5 Dipole Calibration Parameters Page 3 of 19 Model: KX5 FCC ID: OVFKWC-KX5 Dipole Calibration Parameters Page 4 of 19 Model: KX5 FCC ID: OVFKWC-KX5 Dipole Calibration Parameters Page 5 of 19 Model: KX5 FCC ID: OVFKWC-KX5 Dipole Calibration Parameters Page 6 of 19 Model: KX5 FCC ID: OVFKWC-KX5 Dipole Calibration Parameters Page 7 of 19 Model: KX5 FCC ID: OVFKWC-KX5 Dipole Calibration Parameters Page 8 of 19 Model: KX5 FCC ID: OVFKWC-KX5 Dipole Calibration Parameters Page 9 of 19 Model: KX5 FCC ID: OVFKWC-KX5 Dipole Calibration Parameters Page 10 of 19 Model: KX5 FCC ID: OVFKWC-KX5 Dipole Calibration Parameters Page 11 of 19 Model: KX5 FCC ID: OVFKWC-KX5 Dipole Calibration Parameters Page 12 of 19 Model: KX5 FCC ID: OVFKWC-KX5 Dipole Calibration Parameters Page 13 of 19 Model: KX5 FCC ID: OVFKWC-KX5 Dipole Calibration Parameters Page 14 of 19 Model: KX5 FCC ID: OVFKWC-KX5 Dipole Calibration Parameters Page 15 of 19 Model: KX5 FCC ID: OVFKWC-KX5 Dipole Calibration Parameters Page 16 of 19 Model: KX5 FCC ID: OVFKWC-KX5 Dipole Calibration Parameters Page 17 of 19 Model: KX5 FCC ID: OVFKWC-KX5 Dipole Calibration Parameters Page 18 of 19 Model: KX5 FCC ID: OVFKWC-KX5 Dipole Calibration Parameters Page 19 of 19 Model: KX5
FCC ID: OVFKWC-KX5 Probe Calibration Parameters Page 1 of 10 Model: KX5 Appendix C: Probe Calibration Parameters FCC ID: OVFKWC-KX5 Probe Calibration Parameters Page 2 of 10 Model: KX5 FCC ID: OVFKWC-KX5 Probe Calibration Parameters Page 3 of 10 Model: KX5 FCC ID: OVFKWC-KX5 Probe Calibration Parameters Page 4 of 10 Model: KX5 FCC ID: OVFKWC-KX5 Probe Calibration Parameters Page 5 of 10 Model: KX5 FCC ID: OVFKWC-KX5 Probe Calibration Parameters Page 6 of 10 Model: KX5 FCC ID: OVFKWC-KX5 Probe Calibration Parameters Page 7 of 10 Model: KX5 FCC ID: OVFKWC-KX5 Probe Calibration Parameters Page 8 of 10 Model: KX5 FCC ID: OVFKWC-KX5 Probe Calibration Parameters Page 9 of 10 Model: KX5 FCC ID: OVFKWC-KX5 Probe Calibration Parameters Page 10 of 10 Model: KX5
FCC ID: OVFKWC-KX5 _______________________________________________________________________________________ Part 22_24 Report Page 1 of 35 Model: KX5 Test Report On Dual-Band Tri-mode AMPS/CDMA Cellular Phone FCC Part 22 & 24 Certification IC RSS-129 & 133 FCC ID:OVFKWC-KX5 Models:KX5 Date:April 21, 2005 STATEMENT OF CERTIFICATION The data, data evaluation and equipment configuration represented herein are a true and accurate representation of the measurements of the sample’s radio frequency interference emissions characteristics as of the dates and at the times of the test under the conditions herein specified. STATEMENT OF COMPLIANCE This product has been shown to be capable of compliance with the applicable technical standards as indicted in the measurement report and was tested in accordance with the measurement procedures specified in §2.947. Date of Test:April 18, 2005 – April 27, 2005 Test performed by: Kyocera Wireless Corp. 10300 Campus Point Drive San Diego, Ca 92121 Report Prepared by:Fernando Calimbahin, Engineer Report Reviewed by:Lin Lu, Principal Engineer Nemko USA, Inc. performed the tests that required an OATS site. FCC ID: OVFKWC-KX5 _______________________________________________________________________________________ Part 22_24 Report Page 2 of 35 Model: KX5 Table of Contents 1GENERAL INFORMATION.................................................................................................................................................................3 2PRODUCT DESCRIPTION..................................................................................................................................................................4 3ELECTRONIC SERIAL NUMBERS (ESN) PROTECTION............................................................................................................5 4FCC COMPLIANCE EMERGENCY 911............................................................................................................................................5 5TTY COMPLIANCE...............................................................................................................................................................................5 6TRANSMITTER RF POWER OUTPUT.............................................................................................................................................6 6.1 CONDUCTED POWER.............................................................................................................................................................................6 6.2 RADIATED POWER................................................................................................................................................................................7 7TRANSMITTER MODULATION REQUIREMENT.........................................................................................................................8 7.1 TRANSMITTER AUDIO FREQUENCY RESPONSE...............................................................................................................................8 7.2 TRANSMITTER MODULATION DEVIATION LIMITING..................................................................................................................10 8OCCUPIED BANDWIDTH.................................................................................................................................................................11 9SPURIOUS EMISSIONS AT ANTENNA TERMINALS................................................................................................................18 10TRAN…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 4 | 22H | 824.04 MHz - 848.97 MHz | 240.00 mW | 40K0F1D | 2.5 ppm |

Tri-Band CDMA Mobile Phone with Bluetooth+WiFi
Equipment Class
DTS - Digital Transmission System
Tri-Band CDMA Phone
Equipment Class
PCE - PCS Licensed Transmitter held to ear
Tri-Band CDMA Phone
Equipment Class
PCE - PCS Licensed Transmitter held to ear
Single Band CDMA Cellular Phone with Bluetooth
Equipment Class
PCE - PCS Licensed Transmitter held to ear
Cellular/PCS WCDMA/GSM/GPRS/EDGE phone with Bluetooth
Equipment Class
PCE - PCS Licensed Transmitter held to ear