Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Draft ii User Guide for the Kyocera Slider TM Remix KX5 Phone This manual is based on the production version of the Kyocera KX5 phone. Software changes may have occurred after this printing. Kyocera reserves the right to make changes in technical and product specifications without prior notice. The products and equipment described in this documentation are manufactured under license from QUALCOMM Incorporated under one or more of the following U.S. patents: 4,901,307 5,109,390 5,267,262 5,416,797 5,506,865 5,544,196 5,657,420 5,101,501 5,267,261 5,414,796 5,504,773 5,535,239 5,600,754 5,778,338 5,228,054 5,337,338 5,710,784 5,056,109 5,568,483 5,659,569 5,490,165 5,511,073 The Kyocera Wireless Corp. (“KWC”) products described in this manual may include copyrighted KWC and third party software stored in semiconductor memories or other media. Laws in the United States and other countries preserve for KWC and third party software providers certain exclusive rights for copyrighted software, such as the exclusive rights to distribute or reproduce the copyrighted software. Accordingly, any copyrighted software contained in the KWC products may not be modified, reverse engineered, distributed or reproduced in any manner not permitted by law. Furthermore, the purchase of the KWC products shall not be deemed to grant either directly or by implication, estoppel, or otherwise, any license under the copyrights, patents or patent applications of KWC or any third party software provider, except for the normal, non-exclusive royalty- free license to use that arises by operation of law in the sale of a product. Kyocera is a registered trademark and Slider is a trademark of Kyocera Corporation. Race 21 are trademarks of Kyocera Wireless Corp. QUALCOMM is a registered trademark of QUALCOMM Incorporated. Openwave is a trademark of Openwave Systems Incorporated. eZiText is a registered trademark of Zi Corporation. TransFlash is a trademark of SanDisk Corporation. All other trademarks are the property of their respective owners. Copyright © 2005 Kyocera Wireless Corp. All rights reserved. Ringer Tones Copyright © 2000-2002 Kyocera Wireless Corp. 82-M8529-1EN, Rev. 002 FCC/IC Notice This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. To maintain compliance with FCC RF exposure guidelines, if you wear a handset on your body, use the Kyocera Wireless Corp. (KWC) supplied and approved case CV90-G2573-01 and holster CV90-G2958-01. Other accessories used with this device for body-worn operations must not contain any metallic components and must provide at least 25 mm separation distance including the antenna and the user’s body. THIS MODEL PHONE MEETS THE GOVERNMENT’S REQUIREMENTS FOR EXPOSURE TO RADIO WAVES. Your wireless phone is a radio transmitter and receiver. It is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by the Federal Communications Commission of the U.S. Government. These limits are part of comprehensive guidelines and establish permitted levels of RF energy for the general population. The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to assure the safety of all persons, regardless of age and health. User Guide for the Kyocera Slider Remix KX5 Phoneiii The exposure standard for wireless mobile phones employs a unit of measurement known as the Specific Absorption Rate, or SAR. The SAR limit set by the FCC is 1.6 W/kg.* Tests for SAR are conducted using standard operating positions specified by the FCC with the phone transmitting at its highest certified power level in all tested frequency bands. Although the SAR is determined at the highest certified power level, the actual SAR level of the phone while operating can be well below the maximum value. This is because the phone is designed to operate at multiple power levels so as to use only the power required to reach the network. In general, the closer you are to a wireless base station antenna, the lower the power output. Before a phone model is available for sale to the public, it must be tested and certified to the FCC that it does not exceed the limit established by the government-adopted requirement for safe exposure. The tests are performed in positions and locations (e.g., at the ear and worn on the body) as required by the FCC for each model. Body-worn measurements differ among phone models, depending upon availability of accessories and FCC requirements. While there may be differences between the SAR levels of various phones and at various positions, they all meet the government requirement for safe exposure. The FCC has granted an Equipment Authorization for this model phone with all reported SAR levels evaluated as in compliance with the FCC RF emission guidelines. SAR information on this model phone is on file with the FCC and can be found under the Display Grant section http://www.fcc.gov/oet/fccid after searching on the FCC ID: OVFKWC-KX5-5X0. Additional information on SAR can be found on the Cellular Telecommunications and Internet Association (CTIA) web-site at http://www.wow-com.com. * In the United States and Canada, the SAR limit for mobile phones used by the public is 1.6 watts/kg (W/ kg) averaged over one gram of tissue. The standard incorporates a substantial margin of safety to give additional protection for the public and to account for any variations in measurements. Caution The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the warranty and user’s authority to operate the equipment. Optimize your phone’s …
Text truncated - open the document above for the full version.
FCC ID: OVFKWC-KX5-5X0 Kyocera Wireless Corp. 1 August 24, 2005 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 Re: Application for Cellular Transceiver Certification To Whom It May Concern: Kyocera Wireless Corporation (KWC) herein submits the Application for Equipment Authorization (FCC Form 731) and Exhibits for Certification of a Cellular Transceiver, FCC ID: OVFKWC-KX5-5X0. Applicant: Kyocera Wireless Corporation 10300 Campus Point Drive San Diego, CA 92121-1522 Manufacture: Kyocera Wireless Corporation 10300 Campus Point Drive San Diego, CA 92121 The equipment is for mobile station cellular system use. The OVFKWC-KX5-5X0 is in full compliance with all parts of EIA/TIA/IS-98-B&D Mobile Station-Land Station Compatibility Specification, issue July 2000 and March 2001, and also in full compliance with all parts of ANSI J-STD-08, Recommended Minimum Performance Requirements for 1.8 to 2 GHz Code Division Multiple Access (CDMA) Personal Stations, issue July 1996. Information concerning how the ESN protection requirements are met is provided in Exhibit 10. Please contact me at Tel: (858) 882-2406 or Email: [email protected] if there are any questions or if any additional information is needed. Kyocera Wireless Corporation Lin Lu Lin Lu Principal Engineer
FCC ID: OVFKWC-KX5-5X0 Kyocera Wireless Corp. 1 August 24, 2005 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 Re:Request of Confidentiality for FCC ID: OVFKWC-KX5-5X0 To Whom It May Concern: Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules (CFR 47), Kyocera Wireless Corp (KWC) hereby requests confidential and treatment of information accompanying this Application. The materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. We are also requesting Short-Term Confidentiality as outlined in Public Notice DA 04-1705. This provision will give KWC Temporary Confidentiality of commercially sensitive information prior to product launch. The requested Confidential and Temporary Confidential exhibits are listed in table 1 below: Table 1. Confidential and Short-Term Confidential ExhibitDescription 1Operation Descriptions 2Block diagrams 3Schematics Confidential 4Parts Lists 5Instruction Manual 7External Photos Short-Term Confidential 8Internal Photos The Applicant understands that pursuant to Rule 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this Application. Sincerely, C K Li C. K. Li Engineer, Senior Staff/Manager Kyocera Wireless Corp.
Chris Harvey From: C.K. Li [[email protected]] Sent: Wednesday, September 07, 2005 1:13 PM To: Compliance Certification Services Cc: [email protected] Subject: Re: Kyocera Wireless Corp, FCC ID: OVFKWC-KX5-5X0, Assessment NO.: AN05T5101, Notice#1 Page 1 of 2 9/7/2005 Chris, Below please found the more detail supporting info you requested: 1) OVFKWC-KX5-5X0 supports CDMA2000 in 1X (Phase I, Protocol revision 6) mode only. CDMA2000 1X includes TIA/EIA-95B as a subset and was approved for publishing in July 1999. It provides voice and data capabilities within a standard 1.25 MHz CDMA channel. This RF bandwidth is identical to the legacy IS-95 B system standard. For Part 22 and 24, all of CDMA measurements were conducted with Agilent 8960 as a base station simulator. The base station simulator establishes a CDMA link with the test device. The CDMA link that was configured via 8960 for all of measurements as follows. • Radio Configuration: RC1 • Service Options: SO2 • Code domain channels: R-FCH + R-PICH • Cell Power: -100 dBm/1.23MHz to 103 dBm/1.23MHz • Data Rate: full rate To perform SAR tests, the phone was placed in test code mode to transmit maximum power at full rate for the specified channel. The CDMA signal tested was TIA/EIA-95B based, i.e. RC1, SR1 and R-FCH only and full rate. SAR value depends on the transmitter power level and the duty cycle of the power being transmitted. The test device was placed in the test code mode in order to maintain the maximum outputs in all applicable modes during the entire SAR testing. Since the tests were conducted at all channels with phone transmitting maximum power and at full rate, these measurements would indicate the maximum possible SAR value for that particular channel irrespective of RC's, SO's and other data rates. As long as these measurements demonstrate SAR compliance, it should also demonstrate compliance for other configurations that were not tested. 2) Please see updated radiated emission test report (attached). I trust these have answered you questions. CK Li Kyocera Wireless Corp. At 05:03 PM 9/1/2005 +0000, Compliance Certification Services wrote: Dear CK Li, I have reviewed the above referenced application (Pt. 22/24 portion) and have the following items that need to be addressed before the review can be completed: 1. The Operational Description indicates that this device supports certain CDMA2000 Radio- Configurations (RC’s). As other devices from Kyocera also support these same RC’s, and in light of the FCC’s concern about proper operation to at rated average output and crest factor (max/min) to produce the worst possible RF Exposure during SAR testing. Please provide additional explanation (as you have for other applications) to further explain the CDMA2000 modes in this device and the steps taken during testing to ensure the worst case modes were tested. 2. The Radiated Emissions test report has the following items to be addressed: OATS measurements show several points with <20dB margin but no substitution method data provided as stated; test method states ANSI C63.4:2001, as do the measurement descriptions and not the required version of EIA/TIA 603B; test configuration figure does not show substitution method; test equipment list does not show equipment for performing substitution method; there is no indication in the report that the orientation of the handset was changed to determine worst case emissions. Please correct/update the test report. Best regards, Chris Harvey [email protected] The items indicated above must be submitted before processing can continue on the above referenced application. Failure to provide the requested information within 30 days of the original e-mail date may result in application dismissal and forfeiture of the filing fee. Also, please note that partial responses increase processing time and should not be submitted. Any questions about the content of this correspondence should be directed to the e-mail address listed below the name of the sender. Page 2 of 2 9/7/2005
FCC ID: OVFKWC-KX5-5X0 External Photos Page 1 of 3 Model: KX5-5X0 Exhibit 7: OVFKWC-KX5-5X0 External Photos TOP CLOSED AND OPEN FCC ID: OVFKWC-KX5-5X0 External Photos Page 2 of 3 Model: KX5-5X0 BOTTOM CLOSED AND OPEN SIDE CLOSED AND OPEN FCC ID: OVFKWC-KX5-5X0 External Photos Page 3 of 3 Model: KX5-5X0 SIDE CLOSED AND OPEN
FCC ID: OVFKWC-KX5-5X0 Label Information Page 1 of 1 Model: KX5-5X0 Exhibit 6: OVFKWC-KX5-5X0 ID Label Label Format Label Location OVFKWC-KX5-5X0
FCC ID: OVFKWC-KX5-5X0 Internal Photos Page 1 of 5 Model: KX5-5X0 Exhibit 8: OVFKWC-KX5-5X0 Internal Photos FCC ID: OVFKWC-KX5-5X0 Internal Photos Page 2 of 5 Model: KX5-5X0 FCC ID: OVFKWC-KX5-5X0 Internal Photos Page 3 of 5 Model: KX5-5X0 FCC ID: OVFKWC-KX5-5X0 Internal Photos Page 4 of 5 Model: KX5-5X0 FCC ID: OVFKWC-KX5-5X0 Internal Photos Page 5 of 5 Model: KX5-5X0
FCC ID: OVFKWC-KX5-5X0 SAR Report Page 1 of 27 Model: KX5-5X0 SAR Test Report on Dual-Band Tri-mode AMPS/CDMA Cellular Phone with Bluetooth FCC Part 22 & 24 Certification FCC ID: OVFKWC-KX5-5X0 MODEL: KX5-5X0 DATE: August 24, 2005 STATEMENT OF COMPLIANCE Kyocera Wireless Corp declares under its sole responsibility that the product, FCC ID: OVFKWC- KX5-5X0 to which this declaration relates, is in conformity with the appropriate General Population/Uncontrolled RF exposure standards, recommendations and guidelines. It also declares that the product was tested in accordance with the appropriate measurement standards, guidelines and recommended practices. Any deviations from these standards, guidelines and recommended practices are noted: NONE. Date of Test: August 8-16, 2005 Test performed by: Kyocera Wireless Corp 10300 Campus Point Drive San Diego, CA 92121 Report Prepared by: Fernando Calimbahin, Engineer Report Reviewed by: C.K. Li, Engineer Sr. Staff/Manager FCC ID: OVFKWC-KX5-5X0 SAR Report Page 2 of 27 Model: KX5-5X0 Table of Contents 1INTRODUCTION................................................................................................................................................................ 3 2EQUIPMENT UNDER TEST (EUT) ................................................................................................................................. 3 3PRODUCT DESCRIPTION ............................................................................................................................................... 4 4ACCESSORIES: .................................................................................................................................................................. 5 5SAR TEST RESULT SUMMARY ..................................................................................................................................... 6 5.1M AXIMUM RESULTS FOUND DURING SAR EVALUATION................................................................................................ 6 5.2H EAD CONFIGURATION................................................................................................................................................... 6 5.3B ODY WORN CONFIGURATION (WITH KWC BODY WORN ACCESSORIES) ....................................................................... 7 5.4M EASUREMENT UNCERTAINTY....................................................................................................................................... 7 6TEST CONDITIONS........................................................................................................................................................... 8 6.1A MBIENT CONDITIONS.................................................................................................................................................... 8 6.2RF CHARACTERISTICS OF THE TEST SITE......................................................................................................................... 8 6.3T EST SIGNAL, FREQUENCIES AND OUTPUT POWER......................................................................................................... 8 6.4D EVICE TEST CONDITIONS.............................................................................................................................................. 8 7DESCRIPTION OF THE TEST EQUIPMENT ............................................................................................................... 9 7.1D OSIMETRIC SYSTEM...................................................................................................................................................... 9 7.2A DDITIONAL EQUIPMENT NEEDED IN VALIDATION.......................................................................................................... 9 7.3T ISSUE STIMULANTS....................................................................................................................................................... 9 7.4P HANTOMS DESCRIPTION.............................................................................................................................................. 10 7.5I SOTROPIC E-FIELD PROBE............................................................................................................................................ 10 8SYSTEM VALIDATION .................................................................................................................................................. 11 9DESCRIPTION OF THE TEST PROCEDURE............................................................................................................. 12 9.1T EST POSITIONS............................................................................................................................................................ 12 9.1.1Initial Ear Position............................................................................................................................................... 12 9.1.2Cheek Position...................................................................................................................................................... 13 9.1.3Tilt Position .......................................................................................................................................................... 13 9.1.4Body Worn Configuration .................................................................................................................................... 14 9.2S CAN PROCEDURES....................................................................................................................................................... 14 9.3SAR A VERAGING METHODS......................................................................................................................................... 14 10MEASUREMENT UNCERTAINTY ................................................................................................................…
Text truncated - open the document above for the full version.
Appendix A: Validation Test Plots FCC ID: OVFKWC-KX5-5X0 Validation Test PlotsPage 1 of 10Model: KX5-5X0 Date/Time: 08/08/05 08:19:20 Test Laboratory: Kyocera 835MHz Validation, Probe#1713, DAE#530, Dipole#454, 08-08-05 Communication System: CW, Frequency: 835 MHz, Duty Cycle: 1:1 Medium: HSL900,Medium parameters used: f = 835 MHz; σ = 0.888 mho/m; ε r = 40.7; ρ = 1000 kg/m 3 Phantom: SAM 12,Phantom section: Flat Section DASY4 Configuration: Probe: ET3DV6 - SN1713, ConvF(6.29, 6.29, 6.29), Calibrated: 5/19/2005 Sensor-Surface: 4mm (Mechanical And Optical Surface Detection), Electronics: DAE4 Sn530,Calibrated: 1/4/2005 Measurement SW: DASY4, V4.4 Build 3 Postprocessing SW: SEMCAD, V1.8 Build 130 Temperature: Room T = 21.8 +/− 1 deg C, Liquid T = 22.0 +/− 1 deg C Validation Flat/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 36.1 V/m; Power Drift = -0.0006 dB Peak SAR (extrapolated) = 1.47 W/kg SAR(1 g) = 0.994 mW/g; SAR(10 g) = 0.649 mW/g Maximum value of SAR (measured) = 1.08 mW/g 0 dB = 1.08mW/g FCC ID: OVFKWC-KX5-5X0 Validation Test PlotsPage 2 of 10Model: KX5-5X0 Date/Time: 08/09/05 00:47:05 Test Laboratory: Kyocera 835MHz Validation, Probe#1713, DAE#530, Dipole#454, 08-09-05 Communication System: CW, Frequency: 835 MHz, Duty Cycle: 1:1 Medium: HSL900,Medium parameters used: f = 835 MHz; σ = 0.901 mho/m; ε r = 41.9; ρ = 1000 kg/m 3 Phantom: SAM 12,Phantom section: Flat Section DASY4 Configuration: Probe: ET3DV6 - SN1713, ConvF(6.29, 6.29, 6.29), Calibrated: 5/19/2005 Sensor-Surface: 4mm (Mechanical And Optical Surface Detection), Electronics: DAE4 Sn530,Calibrated: 1/4/2005 Measurement SW: DASY4, V4.4 Build 3 Postprocessing SW: SEMCAD, V1.8 Build 130 Temperature: Room T = 21.8 +/− 1 deg C, Liquid T = 22.0 +/− 1 deg C Validation Flat/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 36.3 V/m; Power Drift = -0.005 dB Peak SAR (extrapolated) = 1.53 W/kg SAR(1 g) = 1.02 mW/g; SAR(10 g) = 0.665 mW/g Maximum value of SAR (measured) = 1.11 mW/g 0 dB = 1.11mW/g FCC ID: OVFKWC-KX5-5X0 Validation Test PlotsPage 3 of 10Model: KX5-5X0 Date/Time: 08/10/05 00:27:57 Test Laboratory: Kyocera 835MHz Validation, Probe#1713, DAE#530, Dipole#454, 08-10-05 Communication System: CW, Frequency: 835 MHz, Duty Cycle: 1:1 Medium: HSL900,Medium parameters used: f = 835 MHz; σ = 0.895 mho/m; ε r = 41.4; ρ = 1000 kg/m 3 Phantom: SAM 12,Phantom section: Flat Section DASY4 Configuration: Probe: ET3DV6 - SN1713, ConvF(6.29, 6.29, 6.29), Calibrated: 5/19/2005 Sensor-Surface: 4mm (Mechanical And Optical Surface Detection), Electronics: DAE4 Sn530,Calibrated: 1/4/2005 Measurement SW: DASY4, V4.4 Build 3 Postprocessing SW: SEMCAD, V1.8 Build 130 Temperature: Room T = 21.8 +/− 1 deg C, Liquid T = 22.0 +/− 1 deg C Validation Flat/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 36.7 V/m; Power Drift = -0.1 dB Peak SAR (extrapolated) = 1.53 W/kg SAR(1 g) = 1.02 mW/g; SAR(10 g) = 0.661 mW/g Maximum value of SAR (measured) = 1.11 mW/g 0 dB = 1.11mW/g FCC ID: OVFKWC-KX5-5X0 Validation Test PlotsPage 4 of 10Model: KX5-5X0 Date/Time: 08/11/05 00:23:10 Test Laboratory: Kyocera 835MHz Validation, Probe#1713, DAE#530, Dipole#454, 08-11-05 Communication System: CW, Frequency: 835 MHz, Duty Cycle: 1:1 Medium: HSL900,Medium parameters used: f = 835 MHz; σ = 0.904 mho/m; ε r = 41.7; ρ = 1000 kg/m 3 Phantom: SAM 12,Phantom section: Flat Section DASY4 Configuration: Probe: ET3DV6 - SN1713, ConvF(6.29, 6.29, 6.29), Calibrated: 5/19/2005 Sensor-Surface: 4mm (Mechanical And Optical Surface Detection), Electronics: DAE4 Sn530,Calibrated: 1/4/2005 Measurement SW: DASY4, V4.4 Build 3 Postprocessing SW: SEMCAD, V1.8 Build 130 Temperature: Room T = 21.8 +/− 1 deg C, Liquid T = 22.0 +/− 1 deg C Validation Flat/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 36 V/m; Power Drift = 0.007 dB Peak SAR (extrapolated) = 1.52 W/kg SAR(1 g) = 1.01 mW/g; SAR(10 g) = 0.660 mW/g Maximum value of SAR (measured) = 1.1 mW/g 0 dB = 1.1mW/g FCC ID: OVFKWC-KX5-5X0 Validation Test PlotsPage 5 of 10Model: KX5-5X0 Date/Time: 08/12/05 00:27:22 Test Laboratory: Kyocera 835MHz Validation, Probe#1713, DAE#530, Dipole#454, 08-12-05 Communication System: CW, Frequency: 835 MHz, Duty Cycle: 1:1 Medium: HSL900,Medium parameters used: f = 835 MHz; σ = 0.905 mho/m; ε r = 42; ρ = 1000 kg/m 3 Phantom: SAM 12,Phantom section: Flat Section DASY4 Configuration: Probe: ET3DV6 - SN1713, ConvF(6.29, 6.29, 6.29), Calibrated: 5/19/2005 Sensor-Surface: 4mm (Mechanical And Optical Surface Detection), Electronics: DAE4 Sn530,Calibrated: 1/4/2005 Measurement SW: DASY4, V4.4 Build 3 Postprocessing SW: SEMCAD, V1.8 Build 130 Temperature: Room T = 21.8 +/− 1 deg C, Liquid T = 22.0 +/− 1 deg C Validation Flat/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 36.1 V/m; Power Drift = 0.004 dB Peak SAR (extrapolated) = 1.53 W/kg SAR(1 g) = 1.02 mW/g; SAR(10 g) = 0.662 mW/g Maximum value of SAR (measured) = 1.1 mW/g 0 dB = 1.1mW/g FCC ID: OVFKWC-KX5-5X0 Validation Test PlotsPage 6 of 10Model: KX5-5X0 Date/Time: 08/12/05 05:46:20 Test Laboratory: Kyocera 1900MHz Validation @ 20dBm, Probe 1713, DAE 530, Dipole #5d005, 08-12-05 Communication System: CW 1900, Frequency: 1900 MHz, Duty Cycle: 1:1 Medium: HSL1800,Medium parameters used (interpolated): f = 1900 MHz; σ = 1.39 mho/m; ε r = 41.6; ρ = 1000 kg/m 3 Phantom: SAM 12,Phantom section: Flat Section DASY4 Configuration: Probe: ET3DV6 - SN1713, ConvF(5.18, 5.18, 5.18), Calibrated: 5/19/2005 Sensor-Surface: 4mm (Mechanical And Optical Surface Detection), Electronics: DAE4 Sn530,Calibrated: 1/4/2005 Measurement SW: DASY4, V4.4 Build 3 Postprocessing SW: SEMCAD, V1.8 Build 130 Temperature: Room T = 21.8 +/− 1 deg C, Liquid T = 22.0 +/− 1 deg C 1900Mhz/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 61.8 V/m; Power Drift = -0.006 dB Peak SA…
Text truncated - open the document above for the full version.
Appendix B1: SAR Distribution Plots (Head) FCC ID: OVFKWC-KX5-5X0 SAR Distribution Plots (Head)Page 1 of 28Model: KX5-5X0 Date/Time: 08/10/05 07:56:05 Test Laboratory: Kyocera KX5-5X0 #TQSR, AMPS ch799 Left Cheek Phone Open, Standard Battery Communication System: AMPS, Frequency: 848.97 MHz, Duty Cycle: 1:1 Medium: HSL900,Medium parameters used (interpolated): f = 848.97 MHz; σ = 0.895 mho/m; ε r = 41.4; ρ = 1000 kg/m 3 Phantom: SAM 12,Phantom section: Left Section DASY4 Configuration: Probe: ET3DV6 - SN1713, ConvF(6.29, 6.29, 6.29), Calibrated: 5/19/2005 Sensor-Surface: 4mm (Mechanical And Optical Surface Detection), Electronics: DAE4 Sn530,Calibrated: 1/4/2005 Measurement SW: DASY4, V4.4 Build 3 Postprocessing SW: SEMCAD, V1.8 Build 130 Temperature: Room T = 21.8 +/− 1 deg C, Liquid T = 22.0 +/− 1 deg C AMPS Ch799 LC/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 17.6 V/m; Power Drift = 0.0 dB Peak SAR (extrapolated) = 1.5 W/kg SAR(1 g) = 1.14 mW/g; SAR(10 g) = 0.814 mW/g Info: Interpolated medium parameters used for SAR evaluation! Maximum value of SAR (measured) = 1.21 mW/g 0 dB = 1.21mW/g FCC ID: OVFKWC-KX5-5X0 SAR Distribution Plots (Head)Page 2 of 28Model: KX5-5X0 Date/Time: 08/10/05 07:56:05 Test Laboratory: Kyocera KX5-5X0 #TQSR, AMPS ch383 Left Tilt Phone Open, Standard Battery Communication System: AMPS, Frequency: 836.49 MHz, Duty Cycle: 1:1 Medium: HSL900,Medium parameters used (interpolated): f = 836.49 MHz; σ = 0.895 mho/m; ε r = 41.4; ρ = 1000 kg/m 3 Phantom: SAM 12,Phantom section: Left Section DASY4 Configuration: Probe: ET3DV6 - SN1713, ConvF(6.29, 6.29, 6.29), Calibrated: 5/19/2005 Sensor-Surface: 4mm (Mechanical And Optical Surface Detection), Electronics: DAE4 Sn530,Calibrated: 1/4/2005 Measurement SW: DASY4, V4.4 Build 3 Postprocessing SW: SEMCAD, V1.8 Build 130 Temperature: Room T = 21.8 +/− 1 deg C, Liquid T = 22.0 +/− 1 deg C AMPS Ch383 LT/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 23.2 V/m; Power Drift = -0.2 dB Peak SAR (extrapolated) = 0.770 W/kg SAR(1 g) = 0.603 mW/g; SAR(10 g) = 0.444 mW/g Info: Interpolated medium parameters used for SAR evaluation! Maximum value of SAR (measured) = 0.639 mW/g AMPS Ch383 LT/Zoom Scan (7x7x7)/Cube 1: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 23.2 V/m; Power Drift = -0.2 dB Peak SAR (extrapolated) = 0.698 W/kg SAR(1 g) = 0.485 mW/g; SAR(10 g) = 0.326 mW/g Info: Interpolated medium parameters used for SAR evaluation! Maximum value of SAR (measured) = 0.573 mW/g 0 dB = 0.573mW/g FCC ID: OVFKWC-KX5-5X0 SAR Distribution Plots (Head)Page 3 of 28Model: KX5-5X0 Date/Time: 08/09/05 14:46:29 Test Laboratory: Kyocera KX5-5X0 #TQSR, AMPS ch799 Right Cheek Phone Open, Standard Battery with Bluetooth On Communication System: AMPS, Frequency: 848.97 MHz, Duty Cycle: 1:1 Medium: HSL900,Medium parameters used (interpolated): f = 848.97 MHz; σ = 0.901 mho/m; ε r = 41.9; ρ = 1000 kg/m 3 Phantom: SAM 12,Phantom section: Right Section DASY4 Configuration: Probe: ET3DV6 - SN1713, ConvF(6.29, 6.29, 6.29), Calibrated: 5/19/2005 Sensor-Surface: 4mm (Mechanical And Optical Surface Detection), Electronics: DAE4 Sn530,Calibrated: 1/4/2005 Measurement SW: DASY4, V4.4 Build 3 Postprocessing SW: SEMCAD, V1.8 Build 130 Temperature: Room T = 21.8 +/− 1 deg C, Liquid T = 22.0 +/− 1 deg C AMPS Ch799 RC/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 18.9 V/m; Power Drift = -0.0 dB Peak SAR (extrapolated) = 1.33 W/kg SAR(1 g) = 1.03 mW/g; SAR(10 g) = 0.756 mW/g Info: Interpolated medium parameters used for SAR evaluation! Maximum value of SAR (measured) = 1.09 mW/g 0 dB = 1.09mW/g FCC ID: OVFKWC-KX5-5X0 SAR Distribution Plots (Head)Page 4 of 28Model: KX5-5X0 Date/Time: 08/09/05 08:04:36 Test Laboratory: Kyocera KX5-5X0 #TQSR, AMPS ch383 Right Tilt Phone Open, Standard Battery Communication System: AMPS, Frequency: 836.49 MHz, Duty Cycle: 1:1 Medium: HSL900,Medium parameters used (interpolated): f = 836.49 MHz; σ = 0.901 mho/m; ε r = 41.9; ρ = 1000 kg/m 3 Phantom: SAM 12,Phantom section: Right Section DASY4 Configuration: Probe: ET3DV6 - SN1713, ConvF(6.29, 6.29, 6.29), Calibrated: 5/19/2005 Sensor-Surface: 4mm (Mechanical And Optical …
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 4 | 22H | 824.04 MHz - 848.97 MHz | 164.00 mW | 40K0F1D | 2.5 ppm |

Tri-Band CDMA Mobile Phone with Bluetooth+WiFi
Equipment Class
DTS - Digital Transmission System
Tri-Band CDMA Phone
Equipment Class
PCE - PCS Licensed Transmitter held to ear
Tri-Band CDMA Phone
Equipment Class
PCE - PCS Licensed Transmitter held to ear
Single Band CDMA Cellular Phone with Bluetooth
Equipment Class
PCE - PCS Licensed Transmitter held to ear
Cellular/PCS WCDMA/GSM/GPRS/EDGE phone with Bluetooth
Equipment Class
PCE - PCS Licensed Transmitter held to ear