FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Kyocera International, Inc/
  3. OVFKWC-S6000-150

OVFKWC-S6000-150Dual-Band Dual-Mode Cellular Phone

Kyocera International, Inc
Dual-Band Dual-Mode Cellular Phone - FCC ID OVFKWC-S6000-150 - Kyocera International, Inc
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Mar 11, 2007
Application Purpose
Original Equipment
Date of Application
Mar 11, 2007
Equipment Note
Dual-Band Dual-Mode Cellular Phone
Frequency Range
1851.25000000 - 1908.75000000
Company
Kyocera International, Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗
↗
↗
↗
↗

Test Report

↗
↗
↗
↗
↗
↗
↗
↗
↗
↗

Test Setup Photos

↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ii User Guide for the Kyocera K126C Phone This manual is based on the production version of the Kyocera K126 phone. Software changes may have occurred after this printing. Kyocera reserves the right to make changes in technical and product specifications without prior notice. The products and equipment described in this documentation are manufactured under license from QUALCOMM Incorporated under one or more of the following U.S. patents: 4,901,307 5,109,390 5,267,262 5,416,797 5,506,865 5,544,196 5,657,420 5,101,501 5,267,261 5,414,796 5,504,773 5,535,239 5,600,754 5,778,338 5,228,054 5,337,338 5,710,784 5,056,109 5,568,483 5,659,569 5,490,165 5,511,073 Other patents pending. The Kyocera Wireless Corp. ("KWC") products described in this manual may include copyrighted KWC and third party software stored in semiconductor memories or other media. Laws in the United States and other countries preserve for KWC and third party software providers certain exclusive rights for copyrighted software, such as the exclusive rights to distribute or reproduce the copyrighted software. Accordingly, any copyrighted software contained in the KWC products may not be modified, reverse engineered, distributed or reproduced in any manner not permitted by law. Furthermore, the purchase of the KWC products shall not be deemed to grant either directly or by implication, estoppel, or otherwise, any license under the copyrights, patents or patent applications of KWC or any third party software provider, except for the normal, non-exclusive royalty-free license to use that arises by operation of law in the sale of a product. Kyocera is a registered trademark of Kyocera Corporation. Brick Attack ™ is a trademark of Kyocera Wireless Corp. QUALCOMM is a registered trademark of QUALCOMM, Inc. eZiText is a registered trademark of Zi Corporation. All other trademarks are the property of their respective owners. Copyright © 2007 Kyocera Wireless Corp. All rights reserved. Ringer Tones Copyright © 2000-2007 Kyocera Wireless Corp. 82-G1858-1EN, Rev. X4 FCC Notice This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Other accessories used with this device for body-worn operations must not contain any metallic components and must provide at least 22.5 mm separation distance including the antenna and the user’s body. THIS MODEL PHONE MEETS THE GOVERNMENT’S REQUIREMENTS FOR EXPOSURE TO RADIO WAVES. Your wireless phone is a radio transmitter and receiver. It is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by the Federal Communications Commission of the U.S. Government. These limits are part of comprehensive guidelines and establish permitted levels of RF energy for the general population. The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to assure the safety of all persons, regardless of age and health. The exposure standard for wireless mobile phones employs a unit of measurement known as the Specific Absorption Rate, or SAR. The SAR limit set by the FCC is 1.6 W/kg.* Tests for SAR are conducted using standard operating positions specified by the FCC with the phone transmitting at its highest certified power level in all tested frequency bands. User Guide for the Kyocera K126C Phoneiii Although the SAR is determined at the highest certified power level, the actual SAR level of the phone while operating can be well below the maximum value. This is because the phone is designed to operate at multiple power levels so as to use only the power required to reach the network. In general, the closer you are to a wireless base station antenna, the lower the power output. Before a phone model is available for sale to the public, it must be tested and certified to the FCC that it does not exceed the limit established by the government-adopted requirement for safe exposure. The tests are performed in positions and locations (e.g., at the ear and worn on the body) as required by the FCC for each model. Body-worn measurements differ among phone models, depending upon availability of accessories and FCC requirements. While there may be differences between the SAR levels of various phones and at various positions, they all meet the government requirement for safe exposure. The FCC has granted an Equipment Authorization for this model phone with all reported SAR levels evaluated as in compliance with the FCC RF emission guidelines. SAR information on this model phone is on file with the FCC and can be found under the Display Grant section at http://www.fcc.gov/oet/fccid after searching on the FCC ID: OVFKWC-S6000-150. Additional information on SAR can be found on the Cellular Telecommunications and Internet Association (CTIA) web-site at http://www.wow-com.com. * In the United States and Canada, the SAR limit for mobile phones used by the public is 1.6 watts/kg (W/kg) averaged over one gram of tissue. The standard incorporates a substantial margin of safety to give additional protection for the public and to account for any variations in measurements. Caution The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the warranty and user’s authority to operate the equipment. Optimize your phone’s performance Use the guidelines on page 2 to learn how to optimize the performance and life of your phone and battery. Air bags If you have an air bag, DO NOT place installed or portable phone equipment or other objects over the air bag or in the air bag deployment area. If equipment is not properly installed, you and your passengers ris…

Text truncated - open the document above for the full version.

Cover Letter(s)

FCC ID: OVFKWC-S6000-150 February 20, 2007 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 Re: Application for Cellular Transceiver Certification To Whom It May Concern: Kyocera Wireless Corporation (KWC) herein submits the Application for Equipment Authorization (FCC Form 731) and Exhibits for Certification of a PCS Transceiver, FCC ID: OVFKWC-S6000-150. Applicant: Kyocera Wireless Corp. 10300 Campus Point Drive San Diego, CA 92121-1522 Manufacture: Kyocera Wireless Corp. 10300 Campus Point Drive San Diego, CA 92121 The equipment is for mobile station cellular system use.. The OVFKWC-S6000-150 is in full compliance with all parts of EIA/TIA/IS-98-B&D Mobile Station-Land Station Compatibility Specification, issue July 2000 and March 2001, and also in full compliance with all parts of ANSI J-STD-08, Recommended Minimum Performance Requirements for 1.8 to 2 GHz Code Division Multiple Access (CDMA) Personal Stations, issue July 1996. Please contact me at Tel: (858) 882-3585 or Email: [email protected] if there are any questions or if any additional information is needed. Kyocera Wireless Corp. Thuy To Regulatory Engineer Kyocera Wireless Corp. Page 1 of 1

Cover Letter(s)

FCC ID: OVFKWC-S6000-150 February 20, 2007 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 Re: Request of Confidentiality for FCC ID: OVFKWC-S6000-150 To Whom It May Concern: Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules (CFR 47), Kyocera Wireless Corp. (KWC) hereby requests confidential and treatment of information accompanying this Application. The materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. We are also requesting Short-Term Confidentiality as outlined in Public Notice DA 04-1705. This provision will give KWC Temporary Confidentiality of commercially sensitive information prior to product launch. The requested Confidential and Temporary Confidential exhibits are listed in table 1 below: Table 1. Confidential and Short-Term Confidential Exhibit Description 1A, 1B Operation Descriptions, Tune-Up Procedures 2 Block diagrams 3 Schematics Confidential 4 Parts Lists 5 Instruction Manual 7 External Photos 8 Internal Photos 9E SAR Test Setup Photos 11B EMI Test Setup Photos Short-Term Confidential 12D HAC Test Setup Photos The Applicant understands that pursuant to Rule 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this Application. Sincerely, Thuy To Thuy To Regulatory Engineer Kyocera Wireless Corp. Kyocera Wireless Corp. Page 1 of 1

External Photos

FCC ID: OVFKWC-S6000-150 Exhibit 7: OVFKWC-S6000-150 External Photos TOP AND BOTTOM VIEWS External Photos Page 1 of 2 Model: S6000-150 FCC ID: OVFKWC-S6000-150 SIDE VIEWS External Photos Page 2 of 2 Model: S6000-150

ID Label/Location Info

FCC ID: OVFKWC-S6000-150 Label Information Page 1 of 2 Model: S6000-150 Exhibit 6: OVFKWC-S6000-150 ID Label Label Format: FCC ID: OVFKWC-S6000-150 Label Location: FCC ID: OVFKWC-S6000-150 Label Information Page 2 of 2 Model: S6000-150 FCC declaration statement: Kyocera Wireless Corp. complies with FCC rules Part 2.925(d) that the label shall be permanently affixed to the equipment and shall be readily visible to the purchaser at the time of purchase. 1) This cellular phone has limited label space on the exterior of the unit. The FCC ID label is placed in the battery compartment. 2) The phone will be market without the battery installed. 3) The batteries for these devices are designed for easy removal and that the labels will be visible whenever the batteries are installed, removed, or replaced.

Internal Photos

FCC ID: OVFKWC-S6000-150 Exhibit 8: OVFKWC- S6000-150 Internal Photos Internal Photos Page 1 of 3 Model: S6000-150 FCC ID: OVFKWC-S6000-150 Internal Photos Page 2 of 3 Model: S6000-150 FCC ID: OVFKWC-S6000-150 Internal Photos Page 3 of 3 Model: S6000-150

RF Exposure Info

FCC ID: OVFKWC-S6000-150 SAR Test Report on Dual-Band Dual-mode CDMA Cellular Phone FCC Part 22 & 24 Certification FCC ID: OVFKWC- S6000-150 MODEL: S6000-150 DATE: February 05, 2007 STATEMENT OF COMPLIANCE Kyocera Wireless Corp declares under its sole responsibility that the product, FCC ID: OVFKWC- S6000-150 to which this declaration relates, is in conformity with the appropriate General Population/Uncontrolled RF exposure standards, recommendations and guidelines. It also declares that the product was tested in accordance with the appropriate measurement standards, guidelines and recommended practices. Any deviations from these standards, guidelines and recommended practices are noted: NONE. Date of Test: February 2 - February 3, 2007 Test performed by: Kyocera Wireless Corp 10300 Campus Point Drive San Diego, CA 92121 Report Prepared by: Thuy To, Regulatory Engineer Report Reviewed by: C.K. Li, Principal Hardware Engineer SAR Report Page 1 of 18 Model: S6000-150 FCC ID: OVFKWC-S6000-150 Table of Contents 1 INTRODUCTION..............................................................................................................................................................3 2 EQUIPMENT UNDER TEST (EUT)...............................................................................................................................3 3 PRODUCT DESCRIPTION.............................................................................................................................................4 4 ACCESSORIES:................................................................................................................................................................4 5 SAR TEST RESULT SUMMARY...................................................................................................................................5 5.1 MAXIMUM RESULTS FOUND DURING SAR EVALUATION..............................................................................................5 5.2 HEAD CONFIGURATION.................................................................................................................................................5 5.3 BODY WORN CONFIGURATION (WITH KWC BODY WORN ACCESSORIES) .....................................................................5 5.4 MEASUREMENT UNCERTAINTY.....................................................................................................................................5 6 TEST CONDITIONS.........................................................................................................................................................6 6.1 AMBIENT CONDITIONS..................................................................................................................................................6 6.2 RF CHARACTERISTICS OF THE TEST SITE.......................................................................................................................6 6.3 TEST SIGNAL, FREQUENCIES AND OUTPUT POWER.......................................................................................................6 6.3.1 CDMA2000 Test conditions.................................................................................................................................6 6.4 DEVICE TEST CONDITIONS............................................................................................................................................7 7 DESCRIPTION OF THE TEST EQUIPMENT.............................................................................................................8 7.1 DOSIMETRIC SYSTEM....................................................................................................................................................8 7.2 ADDITIONAL EQUIPMENT NEEDED IN VALIDATION........................................................................................................9 7.3 TISSUE STIMULANTS.....................................................................................................................................................9 7.4 PHANTOMS DESCRIPTION..............................................................................................................................................9 7.5 ISOTROPIC E-FIELD PROBE..........................................................................................................................................10 8 SYSTEM VALIDATION................................................................................................................................................11 9 DESCRIPTION OF THE TEST PROCEDURE...........................................................................................................12 9.1 TEST POSITIONS..........................................................................................................................................................12 9.1.1 Initial Ear Position.............................................................................................................................................12 9.1.2 Cheek Position....................................................................................................................................................13 9.1.3 Tilt Position........................................................................................................................................................13 9.1.4 Body Worn Configuration..................................................................................................................................14 9.2 SCAN PROCEDURES.....................................................................................................................................................14 9.3 SAR AVERAGING METHODS.......................................................................................................................................14 10 MEASUREMENT UNCERTAINTY..............................................................…

Text truncated - open the document above for the full version.

RF Exposure Info

FCC ID: OVFKWC-S6000-150 Appendix A: Validation Test Plots Validation Test Plots Page 1 of 1 Model: S6000-150 Date/Time: 2/2/2007 12:40:18 PM Test Laboratory: Kyocera-Wireless Corp. 835Mhz Validation in Head Liquid @ 20dBm with Probe 1664, DAE 493 and Dipole 454 Communication System: CW, Frequency: 835 MHz, Duty Cycle: 1:1 Medium: HSL900,Medium parameters used: f = 835 MHz; σ = 0.916 mho/m; ε r = 41.7; ρ = 1000 kg/m 3 Phantom: SAM 12,Phantom section: Flat Section DASY4 Configuration: Probe: ET3DV6 - SN1664, ConvF(6.58, 6.58, 6.58), Calibrated: 6/22/2006 Sensor-Surface: 4mm (Mechanical And Optical Surface Detection), Electronics: DAE3 Sn493,Calibrated: 11/7/2006 Measurement SW: DASY4, V4.7 Build 53 Postprocessing SW: SEMCAD, V1.8 Build 160 Temperature: Room T = 21.8 +/− 1 deg C, Liquid T = 22.0 +/− 1 deg C 20 dbm validation/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 34.8 V/m; Power Drift = -0.038 dB Peak SAR (extrapolated) = 1.28 W/kg SAR(1 g) = 0.917 mW/g; SAR(10 g) = 0.601 mW/g 0 dB = 0.990mW/g Date/Time: 2/2/2007 8:17:39 PM Test Laboratory: Kyocera-Wireless Corp. 835Mhz Validation in Muscle Liquid @ 20dBm with Probe 1664, DAE 493 and Dipole 454 Communication System: CW, Frequency: 835 MHz, Duty Cycle: 1:1 Medium: M900,Medium parameters used: f = 835 MHz; σ = 0.941 mho/m; ε r = 53.5; ρ = 1000 kg/m 3 Phantom: SAM 12,Phantom section: Flat Section DASY4 Configuration: Probe: ET3DV6 - SN1664, ConvF(6.43, 6.43, 6.43), Calibrated: 6/22/2006 Sensor-Surface: 4mm (Mechanical And Optical Surface Detection), Electronics: DAE3 Sn493,Calibrated: 11/7/2006 Measurement SW: DASY4, V4.7 Build 53 Postprocessing SW: SEMCAD, V1.8 Build 160 Temperature: Room T = 21.8 +/− 1 deg C, Liquid T = 22.0 +/− 1 deg C 20 dbm validation/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 35.1 V/m; Power Drift = -0.002 dB Peak SAR (extrapolated) = 1.36 W/kg SAR(1 g) = 0.980 mW/g; SAR(10 g) = 0.650 mW/g 0 dB = 1.06mW/g Date/Time: 2/3/2007 12:15:42 AM Test Laboratory: Kyocera-Wireless Corp. 835Mhz Validation in Muscle Liquid @ 20dBm with Probe 1664, DAE 493 and Dipole 454 Communication System: CW, Frequency: 835 MHz, Duty Cycle: 1:1 Medium: M900,Medium parameters used: f = 835 MHz; σ = 0.94 mho/m; ε r = 54.2; ρ = 1000 kg/m 3 Phantom: SAM 12,Phantom section: Flat Section DASY4 Configuration: Probe: ET3DV6 - SN1664, ConvF(6.43, 6.43, 6.43), Calibrated: 6/22/2006 Sensor-Surface: 4mm (Mechanical And Optical Surface Detection), Electronics: DAE3 Sn493,Calibrated: 11/7/2006 Measurement SW: DASY4, V4.7 Build 53 Postprocessing SW: SEMCAD, V1.8 Build 160 Temperature: Room T = 21.8 +/− 1 deg C, Liquid T = 22.0 +/− 1 deg C 20 dbm validation/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 35.6 V/m; Power Drift = 0.003 dB Peak SAR (extrapolated) = 1.45 W/kg SAR(1 g) = 1.01 mW/g; SAR(10 g) = 0.666 mW/g Maximum value of SAR (measured) = 1.10 mW/g 0 dB = 1.10mW/g Date/Time: 2/1/2007 2:05:32 AM Test Laboratory: Kyocera-Wireless Corp. 1900Mhz Validation in Head Liquid @ 20dBm with Probe 1664, DAE 493 and Dipole 5d003 Communication System: CW, Frequency: 1900 MHz, Duty Cycle: 1:1 Medium: HSL1800,Medium parameters used (interpolated): f = 1900 MHz; σ = 1.38 mho/m; ε r = 40.2; ρ = 1000 kg/m 3 Phantom: SAM 12,Phantom section: Flat Section DASY4 Configuration: Probe: ET3DV6 - SN1664, ConvF(5.05, 5.05, 5.05), Calibrated: 6/22/2006 Sensor-Surface: 4mm (Mechanical And Optical Surface Detection), Electronics: DAE3 Sn493,Calibrated: 11/7/2006 Measurement SW: DASY4, V4.7 Build 53 Postprocessing SW: SEMCAD, V1.8 Build 160 Temperature: Room T = 21.8 +/− 1 deg C, Liquid T = 22.0 +/− 1 deg C 1900MHz Validation @20dBm/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 59.1 V/m; Power Drift = -0.049 dB Peak SAR (extrapolated) = 6.54 W/kg SAR(1 g) = 3.8 mW/g; SAR(10 g) = 2.02 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 4.29 mW/g 0 dB = 4.29mW/g Date/Time: 2/2/2007 12:51:31 AM Test Laboratory: Kyocera-Wireless Corp. 1900Mhz Validation in Head Liquid @ 20dBm with Probe 1664, DAE 493 and Dipole 5d003 Communication System: CW, Frequency: 1900 MHz, Duty Cycle: 1:1 Medium: HSL1800,Medium parameters used (interpolated): f = 1900 MHz; σ = 1.43 mho/m; ε r = 39.7; ρ = 1000 kg/m 3 Phantom: SAM 12,Phantom section: Flat Section DASY4 Configuration: Probe: ET3DV6 - SN1664, ConvF(5.05, 5.05, 5.05), Calibrated: 6/22/2006 Sensor-Surface: 4mm (Mechanical And Optical Surface Detection), Electronics: DAE3 Sn493,Calibrated: 11/7/2006 Measurement SW: DASY4, V4.7 Build 53 Postprocessing SW: SEMCAD, V1.8 Build 160 Temperature: Room T = 21.8 +/− 1 deg C, Liquid T = 22.0 +/− 1 deg C 1900MHz Validation @20dBm/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 58.8 V/m; Power Drift = -0.018 dB Peak SAR (extrapolated) = 6.80 W/kg SAR(1 g) = 3.92 mW/g; SAR(10 g) = 2.07 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 4.41 mW/g 0 dB = 4.41mW/g Date/Time: 2/2/2007 1:18:58 AM Test Laboratory: Kyocera-Wireless Corp. 1900Mhz Validation in Muscle Liquid @ 20dBm with Probe 1664, DAE 493 and Dipole 5d003 Communication System: CW, Frequency: 1900 MHz, Duty Cycle: 1:1 Medium: M1800,Medium parameters used: f = 1900 MHz; σ = 1.48 mho/m; ε r = 52.8; ρ = 1000 kg/m 3 Phantom: SAM 12,Phantom section: Flat Section DASY4 Configuration: Probe: ET3DV6 - SN1664, ConvF(4.57, 4.57, 4.57), Calibrated: 6/22/2006 Sensor-Surface: 4mm (Mechanical And Optical Surface Detection), Electronics: DAE3 Sn493,Calibrated: 11/7/2006 Measurement SW: DASY4, V4.7 Build 53 Postprocessing SW: SEMCAD, V1.8 Build 160 Temperature: Room T = 21.8 +/− 1 deg C, Liquid T = 22.0 +/− 1 deg C 1900MHz Validation @20dBm/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 58.6 V/m; Power Drift = -0.020 dB Peak SAR (extrapolate…

Text truncated - open the document above for the full version.

RF Exposure Info

Appendix B1: SAR Distribution Plots (Head) FCC ID: OVFKWC-S6000-150 SAR Distribution PlotsPage 1 of 11Model#: S6000-150 Date/Time: 2/2/2007 4:40:17 PM Test Laboratory: Kyocera-Wireless Corp. S6000 #0036 CDMA-800 Ch1013 Left Cheek Communication System: CDMA-800, Frequency: 824.7 MHz, Duty Cycle: 1:1 Medium: HSL900,Medium parameters used (interpolated): f = 824.7 MHz; σ = 0.916 mho/m; ε r = 41.7; ρ = 1000 kg/m 3 Phantom: SAM 12,Phantom section: Left Section DASY4 Configuration: Probe: ET3DV6 - SN1664, ConvF(6.58, 6.58, 6.58), Calibrated: 6/22/2006 Sensor-Surface: 4mm (Mechanical And Optical Surface Detection), Electronics: DAE3 Sn493,Calibrated: 11/7/2006 Measurement SW: DASY4, V4.7 Build 53 Postprocessing SW: SEMCAD, V1.8 Build 160 Temperature: Room T = 21.8 +/− 1 deg C, Liquid T = 22.0 +/− 1 deg C CDMA-800 Ch1013 LC/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 34.4 V/m; Power Drift = -0.022 dB Peak SAR (extrapolated) = 1.86 W/kg SAR(1 g) = 1.38 mW/g; SAR(10 g) = 1 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.47 mW/g 0 dB = 1.47mW/g FCC ID: OVFKWC-S6000-150 SAR Distribution PlotsPage 2 of 11Model#: S6000-150 Date/Time: 2/2/2007 5:47:18 PM Test Laboratory: Kyocera-Wireless Corp. S6000 #0036 CDMA-800 Ch383 Left Tilt Communication System: CDMA-800, Frequency: 836.49 MHz, Duty Cycle: 1:1 Medium: HSL900,Medium parameters used (interpolated): f = 836.49 MHz; σ = 0.916 mho/m; ε r = 41.7; ρ = 1000 kg/m 3 Phantom: SAM 12,Phantom section: Left Section DASY4 Configuration: Probe: ET3DV6 - SN1664, ConvF(6.58, 6.58, 6.58), Calibrated: 6/22/2006 Sensor-Surface: 4mm (Mechanical And Optical Surface Detection), Electronics: DAE3 Sn493,Calibrated: 11/7/2006 Measurement SW: DASY4, V4.7 Build 53 Postprocessing SW: SEMCAD, V1.8 Build 160 Temperature: Room T = 21.8 +/− 1 deg C, Liquid T = 22.0 +/− 1 deg C CDMA-800 Ch383 LT/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 29.6 V/m; Power Drift = -0.182 dB Peak SAR (extrapolated) = 0.964 W/kg SAR(1 g) = 0.736 mW/g; SAR(10 g) = 0.534 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.777 mW/g CDMA-800 Ch383 LT/Zoom Scan (7x7x7)/Cube 1: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 29.6 V/m; Power Drift = -0.182 dB Peak SAR (extrapolated) = 1.02 W/kg SAR(1 g) = 0.669 mW/g; SAR(10 g) = 0.446 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.727 mW/g 0 dB = 0.727mW/g FCC ID: OVFKWC-S6000-150 SAR Distribution PlotsPage 3 of 11Model#: S6000-150 Date/Time: 2/2/2007 1:45:50 PM Test Laboratory: Kyocera-Wireless Corp. S6000 #0036 CDMA-800 Ch1013 Right Cheek Communication System: CDMA-800, Frequency: 824.7 MHz, Duty Cycle: 1:1 Medium: HSL900,Medium parameters used (interpolated): f = 824.7 MHz; σ = 0.916 mho/m; ε r = 41.7; ρ = 1000 kg/m 3 Phantom: SAM 12,Phantom section: Right Section DASY4 Configuration: Probe: ET3DV6 - SN1664, ConvF(6.58, 6.58, 6.58), Calibrated: 6/22/2006 Sensor-Surface: 4mm (Mechanical And Optical Surface Detection), Electronics: DAE3 Sn493,Calibrated: 11/7/2006 Measurement SW: DASY4, V4.7 Build 53 Postprocessing SW: SEMCAD, V1.8 Build 160 Temperature: Room T = 21.8 +/− 1 deg C, Liquid T = 22.0 +/− 1 deg C CDMA-800 Ch1013 RC/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 35.6 V/m; Power Drift = -0.031 dB Peak SAR (extrapolated) = 1.94 W/kg SAR(1 g) = 1.44 mW/g; SAR(10 g) = 1.04 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.53 mW/g 0 dB = 1.53mW/g FCC ID: OVFKWC-S6000-150 SAR Distribution PlotsPage 4 of 11Model#: S6000-150 FCC ID: OVFKWC-S6000-150 SAR Distribution PlotsPage 5 of 11Model#: S6000-150 Date/Time: 2/2/2007 3:12:07 PM Test Laboratory: Kyocera-Wireless Corp. S6000 #0036 CDMA-800 Ch383 Right Tilt Communication System: CDMA-800, Frequency: 836.49 MHz, Duty Cycle: 1:1 Medium: HSL900,Medium parameters used (interpolated): f = 836.49 MHz; σ = 0.916 mho/m; ε r = 41.7; ρ = 1000 kg/m 3 Phantom: SAM 12,Phantom section: Right Section DASY4 Configuration: Probe: ET3DV6 - SN1664, ConvF(6.58, 6.58, 6.58), Calibrated: 6/22/2006 Sensor-Surface: 4mm (Mechanical And Optical Surface Detection), Electronics: DAE3 Sn493,Calibrated: 11/7/2006 Measurement SW: DASY4, V4.7 Build 53 Postprocessing SW: SEMCAD, V1.8 Build 160 Temperature: Room T = 21.8 +/− 1 deg C, Liquid T = 22.0 +/− 1 deg C CDMA-800 Ch383 RT/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 28.9 V/m; Power Drift = 0.041 dB Peak SAR (extrapolated) = 0.964 W/kg SAR(1 g) = 0.764 mW/g; SAR(10 g) = 0.557 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.824 mW/g CDMA-800 Ch383 RT/Zoom Scan (7x7x7)/Cube 1: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 28.9 V/m; Power Drift = 0.041 dB Peak SAR (extrapolated) = 0.991 W/kg SAR(1 g) = 0.694 mW/g; SAR(10 g) = 0.482 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.756 mW/g 0 dB = 0.756mW/g FCC ID: OVFKWC-S6000-150 SAR Distribution PlotsPage 6 of 11Model#: S6000-150 Date/Time: 2/1/2007 5:24:20 PM Test Laboratory: Kyocera-Wireless Corp. S6000 #0036 PCS Ch600 Left Cheek Communication System: CDMA-1900, Frequency: 1880 MHz, Duty Cycle: 1:1 Medium: HSL1800,Medium parameters used: f = 1880 MHz; σ = 1.38 mho/m; ε r = 40.2; ρ = 1000 kg/m 3 Phantom: SAM 12,Phantom section: Left Section DASY4 Configuration: Probe: ET3DV6 - SN1664, ConvF(5.05, 5.05, 5.05), Calibrated: 6/22/2006 Sensor-Surface: 4mm (Mechanical And Optical Surface Detection), Electronics: DAE3 Sn493,Calibrated: 11/7/2006 Measurement SW: DASY4, V4.7 Build 53 Postprocessing SW: SEMCAD, V1.8 Build 160 Temperature: Room T = 21.8 +/− 1 deg C, Liquid T = 22.0 +/− 1 deg C CDMA-1900 Ch600 LC/Zoom Scan (7x7x7)/Cube 0: Measure…

Text truncated - open the document above for the full version.

RF Exposure Info

Appendix B: SAR Distribution Plots (Body) FCC ID: OVFKWC-S6000-150 SAR Distribution PlotsPage 1 of 7Model#: S6000-150 Date/Time: 2/3/2007 3:31:00 AM Test Laboratory: Kyocera-Wireless Corp. S6000 #0036 CDMA-800 Ch1013 Flat with 22.5mm Air Space, RC3 - SO32 (FCH + SCH) Communication System: CDMA-800, Frequency: 824.7 MHz, Duty Cycle: 1:1 Medium: M900,Medium parameters used (interpolated): f = 824.7 MHz; σ = 0.94 mho/m; ε r = 54.2; ρ = 1000 kg/m 3 Phantom: SAM 12,Phantom section: Flat Section DASY4 Configuration: Probe: ET3DV6 - SN1664, ConvF(6.43, 6.43, 6.43), Calibrated: 6/22/2006 Sensor-Surface: 4mm (Mechanical And Optical Surface Detection), Electronics: DAE3 Sn493,Calibrated: 11/7/2006 Measurement SW: DASY4, V4.7 Build 53 Postprocessing SW: SEMCAD, V1.8 Build 160 Temperature: Room T = 21.8 +/− 1 deg C, Liquid T = 22.0 +/− 1 deg C CDMA-800 FLAT Ch1013/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 18.4 V/m; Power Drift = -0.084 dB Peak SAR (extrapolated) = 0.845 W/kg SAR(1 g) = 0.684 mW/g; SAR(10 g) = 0.502 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.731 mW/g 0 dB = 0.731mW/g FCC ID: OVFKWC-S6000-150 SAR Distribution PlotsPage 2 of 7Model#: S6000-150 FCC ID: OVFKWC-S6000-150 SAR Distribution PlotsPage 3 of 7Model#: S6000-150 Date/Time: 2/3/2007 2:02:43 AM Test Laboratory: Kyocera-Wireless Corp. S6000 #0036 CDMA-800 Ch1013 Flat with CV90-61346, RC3 - SO32 (FCH + SCH) Communication System: CDMA-800, Frequency: 824.7 MHz, Duty Cycle: 1:1 Medium: M900,Medium parameters used (interpolated): f = 824.7 MHz; σ = 0.94 mho/m; ε r = 54.2; ρ = 1000 kg/m 3 Phantom: SAM 12,Phantom section: Flat Section DASY4 Configuration: Probe: ET3DV6 - SN1664, ConvF(6.43, 6.43, 6.43), Calibrated: 6/22/2006 Sensor-Surface: 4mm (Mechanical And Optical Surface Detection), Elect…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Thuy To(Regulatory Affairs Manager)
[email protected]619-318-5290Fax: 858-882-2010

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
224E1.85 GHz - 1.91 GHz482.00 mW1M25F9W2.5 ppm
Confidentiality
Long Term
Grant Notes
Power output is ERP for Pt. 22 and EIRP for Pt. 24. Body -worn operations are restricted the specific belt-clips/holsters/accessories tested for this filing or must provide at least 2.25 cm separation between the device, including its antenna whether extended or retracted, and the users body and not contain any metallic components. End -users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for single- and co-transmit configurations under this FCC ID are CDMA Pt 22 SAR are head: 1.44 W/kg and body: 0.684 W/kg, for PCS Pt 24 head: 1.37 W/kg and body: 0.910 W/kg. HAC rating: M3/T3:2006

Other Applications from Kyocera International, Inc

Tri-Band CDMA Mobile Phone with Bluetooth+WiFi - FCC ID OVFC51213CD - Kyocera International, Inc
OVFC51213CD

Tri-Band CDMA Mobile Phone with Bluetooth+WiFi

Sep 01, 2011

Equipment Class

DTS - Digital Transmission System
Tri-Band CDMA Phone - FCC ID OVFS13503CB - Kyocera International, Inc
OVFS13503CB

Tri-Band CDMA Phone

May 17, 2011

Equipment Class

PCE - PCS Licensed Transmitter held to ear
Tri-Band CDMA Phone - FCC ID OVF-K5502 - Kyocera International, Inc
OVF-K5502

Tri-Band CDMA Phone

Jan 24, 2011

Equipment Class

PCE - PCS Licensed Transmitter held to ear
Single Band CDMA Cellular Phone with Bluetooth - FCC ID OVF-K5501 - Kyocera International, Inc
OVF-K5501

Single Band CDMA Cellular Phone with Bluetooth

Nov 07, 2010

Equipment Class

PCE - PCS Licensed Transmitter held to ear
Cellular/PCS WCDMA/GSM/GPRS/EDGE phone with Bluetooth - FCC ID OVF-C4700 - Kyocera International, Inc
OVF-C4700

Cellular/PCS WCDMA/GSM/GPRS/EDGE phone with Bluetooth

Aug 09, 2010

Equipment Class

PCE - PCS Licensed Transmitter held to ear