OZIRC-07SURGE PROTECTED POWER STRIP WITH TWO GROUP REMOTE CONTROLLED OUTLETS

San Shih Electrical Enterprise Co Ltd
SURGE PROTECTED POWER STRIP WITH TWO GROUP REMOTE CONTROLLED OUTLETS - FCC ID OZIRC-07 - San Shih Electrical Enterprise Co Ltd
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jan 31, 2010
Application Purpose
Original Equipment
Date of Application
Jan 31, 2010
Equipment Note
SURGE PROTECTED POWER STRIP WITH TWO GROUP REMOTE CONTROLLED OUTLETS
Frequency Range
433.92000000 - 433.92000000
Company
San Shih Electrical Enterprise Co Ltd
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Operational Description

↗

Schematics

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Install and Operation of remote controlled power strip 1. RC-07 is remote controller has two switch to control power strip which has two group of outlets and two always ON outlets, and LED on front cover to indicat the status of this power strip. 2. First, plug strip receiver into wall outlet to connect to the AC supply. To make it work normally. 3. Then, plug appliances into two group of outlets, each group has 4 outlets plus two always ON outlets Max power is 1800Watts. 4. Sliding up the zone 1 switch at RCU to control 4 outlets ON/OFF in zone 1 group, and zone 2 switch for group zone 2 outlets.ON/OFF, the zone 1 and zone 2 can power ON the same time to provide max. power or one zone ON and other OFF. User also can power OFF both zone with sliding switch. The always ON outlets keep the power until you un-plug the power cord. LED on front has four, two blue color LED to indicate ON/OFF of zone 1/2, one green color LED to indicate grounded function is work or not, and one red color LED to indicate surge protect function is work or not. 5. The reset button in rear side for resetting power strip when over current happen. 6. The Transmitter remote can easily control receiver within 30 meter distance. FCC NOTE: This device complies with part 15 of FCC rules operation is subject to the following two conditions (1) This device may not cause harmful interference, and (2) this device must accept any interference that may be received, including interference that may cause undesired operation. THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.

Block Diagram

Two sliding key ON /OFF Encoder Mixer OSC Amplifier ANT Block diagram of Transmitter RC-07 SAW/ 433.92M H z 433MHz

Cover Letter(s)

San Shih Electrical Enterprise Co., Ltd. FCC ID: OZI RC-07 POWER OF ATTORNEY Jan.20, 2010 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: We, the undersigned, hereby authorize Waltek Services (ShenZhen) Co., Ltd. (Philo Zhong) on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Waltek Services (ShenZhen) Co., Ltd. (Philo Zhong) on our behalf shall have the same effect as acts of our own. This authorization expires on Jan.21, 2011. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. We, San Shih Electrical Enterprise Co., Ltd., are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Sincerely, San Shih Electrical Enterprise Co., Ltd. --------- Manager

External Photos

San Shih Electrical Enterprise Co., Ltd. FCC ID: OZIRC-07 Page 27 of 29 12 Photographs - Constructional Details 12.1 EUT - Front View 12.2 EUT - Back View

ID Label/Location Info

San Shih Electrical Enterprise Co., Ltd. FCC ID: OZIRC-07 Page 29 of 29 13 FCC ID Label This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1)this device may not cause harmful interference,and (2) this device must accept any interference received, including interference that may cause undesired operation The Label must not be a stick-on paper. The Label on these products must be permanently affixed to the product and readily visible at the time of purchase and must last the expected lifetime of the equipment not be readily detachable. Proposed Label Location on EUT EUT Bottom View/proposed FCC Label Location FCC ID: OZIRC-07 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1)this device may not cause harmful interference,and (2) this device must accept any interference received, including interference that may cause undesired operation

ID Label/Location Info

FCC ID Label Sample for Model : RC-07 FCC ID: OZIRC-07 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1)this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Internal Photos

San Shih Electrical Enterprise Co., Ltd. FCC ID: OZIRC-07 Page 28 of 29 12.3 PCB-Front View 12.4 PCB-Back View

Operational Description

Circuit Description This is a Surge protected power strip with two group remote controlled outlets.that is two sliding key,one is ON and one is OFF,when press ON/OFF button,the transmitter will transmit a signal to the encoder,and after the encoder,the dealed signal to the Mixer, which the osc is 433.92MHz,the mixed signal to the amplifier,the amplifier make the signal more stronger,and final to the antenna,send the 433.92MHz signal out .

Schematics

55 44 33 22 11 D D C C B B A A ON A ANT PCB D OFF C Fairchild OFF Fairchild ON B 2009/11/25 Jack SURC07XXX 11 <OrgAddr1> WI-I-23 <OrgAddr3> RC-07 A Approved ±5% Draw No: PRODUCT NAME Rev: Sheet of Date: Part No: Designer Tolerance Material Unit Scale Check by 三 石 電 器 企 業 有 限 公 司 SAN SHIH ELECTRICAL ENTERPRISE.,LTD mm +3V +3V +3V D2 BAT54C BT1 3V R91M R5 10K R6 10K Y1 HDR433M R2 470K R1 10K L2 180nH 0805 C112P C7 4.7PF L1 27nH 0603 C6 0.1UF U1 PT2260-R4S, SOP-16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 A0 A1 A2 A3 A4 A5 A6 A7 VSS D3 D2 D1 D0 OSC DOUT VCC D1 BAT54C SW1 1 2 3 4 5 6 SW2 1 2 3 4 5 6 R7 10K R8 10K C5 220PF C30.1UF C4 1PF U2PT4450 123 456 0S-OUTVSSRF-OUT DIN VDD OS-IN R30ohm

Test Report

San Shih Electrical Enterprise Co., Ltd. FCC ID: OZIRC-07 FCC TEST REPORT Page 1 of 29 FCC ID : OZIRC-07 Applicant : San Shih Electrical Enterprise Co., Ltd. Adress of Applicant : No 209, Sec ,3 County Boulevard, Pan Chiao City, Taipei Hsien, Taiwan. Equipment Under Test (EUT) : Product description : Surge protected power strip with two group remote controlled outlets Model No. : RC-07 Standards : FCC 15 Subpart C Paragraph 15.231 Date of Test : Jan.20,2010 Test Engineer : Olic.Huang Reviewed By : PERPARED BY: Waltek Services (Shenzhen) Co., Ltd. 1/F, Fukangtai Building,West Baima Rd.,Songgang Street, Baoan District, Shenzhen 518105,China Tel: +86-755-27553488 Fax: +86-755-27553868 San Shih Electrical Enterprise Co., Ltd. FCC ID: OZIRC-07 Page 2 of 29 2 Contents Page 1 COVER PAGE..........................................................................................................................................................1 2 CONTENTS ..............................................................................................................................................................2 3 TEST SUMMARY....................................................................................................................................................4 4 GENERAL INFORMATION..................................................................................................................................5 4.1 CLIENT INFORMATION............................................................................................................................................5 4.2 GENERAL DESCRIPTION OF E.U.T...........................................................................................................................5 4.3 DETAILS OF E.U.T. .................................................................................................................................................5 4.4 DESCRIPTION OF SUPPORT UNITS...........................................................................................................................5 4.5 STANDARDS APPLICABLE FOR TESTING..................................................................................................................5 4.6 TEST FACILITY........................................................................................................................................................6 4.7 TEST LOCATION......................................................................................................................................................6 5 EQUIPMENT USED DURING TEST ...................................................................................................................7 6 CONDUCTED EMISSION TEST ........................................................................................................................10 6.1 TEST EQUIPMENT..................................................................................................................................................10 6.2 TEST PROCEDURE.................................................................................................................................................10 6.3 CONDUCTED TEST SETUP.....................................................................................................................................11 6.4 EUT OPERATING CONDITION...............................................................................................................................11 6.5 CONDUCTED EMISSION LIMITS.............................................................................................................................12 6.6 CONDUCTED EMISSION TEST DATA......................................................................................................................12 7 RADIATION EMISSION TEST...........................................................................................................................13 7.1 TEST EQUIPMENT..................................................................................................................................................13 7.2 MEASUREMENT UNCERTAINTY.............................................................................................................................13 7.3 TEST PROCEDURE.................................................................................................................................................13 7.4 RADIATED TEST SETUP.........................................................................................................................................14 7.5 SPECTRUM ANALYZER SETUP...............................................................................................................................14 7.6 CORRECTED AMPLITUDE & MARGIN CALCULATION............................................................................................15 7.7 SUMMARY OF TEST RESULTS................................................................................................................................15 7.8 EUT OPERATING CONDITION...............................................................................................................................16 7.9 RADIATED EMISSIONS LIMIT.................................................................................................................................16 7.10 RADIATED EMISSIONS TEST RESULT................................................................................................................17 7.10.1 Radiated Emission Test Data .....................................................................................................................17 8 ANTENNA REQUIREMENT...............................................................................................................................20 9 PERIODIC OPERATION ..........................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

San Shih Electrical Enterprise Co., Ltd. FCC ID: OZIRC-07 Page 26 of 29 11 Photographs of Testing 11.1 Radiation Emission Test View For 30MHz-1000MHz 11.2 Radiation Emission Test View For 1GHz-5GHz

Contact Information

Applicant

Y. Y. Hong(Manager)
[email protected]886-2-2253-5336Fax: 886-2-2253-0442

Test Firm

Waltek Services(Shenzhen) Co., Ltd.Philo zhong
[email protected]0086-755-27553488Fax: 0086-755-27553868

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-

Other Applications from San Shih Electrical Enterprise Co Ltd

SURGE PROTECTED POWER STRIP WITH TWO GROUP REMOTE CONTROLLED OUTLETS - FCC ID OZIZW-XXX - San Shih Electrical Enterprise Co Ltd
OZIZW-XXX

SURGE PROTECTED POWER STRIP WITH TWO GROUP REMOTE CONTROLLED OUTLETS

Jan 03, 2011

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
SURGE PROTECTED POWER STRIP WITH TWO GROUP REMOTE CONTROLLED OUTLETS - FCC ID OZIZW-02A - San Shih Electrical Enterprise Co Ltd
OZIZW-02A

SURGE PROTECTED POWER STRIP WITH TWO GROUP REMOTE CONTROLLED OUTLETS

Jan 03, 2011

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Surge protected power strip with two group remote controlled outlets - FCC ID OZISPP5107XXXX - San Shih Electrical Enterprise Co Ltd
OZISPP5107XXXX

Surge protected power strip with two group remote controlled outlets

Dec 22, 2010

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter
Remote Control Transmitter - FCC ID OZIRC-02 - San Shih Electrical Enterprise Co Ltd
OZIRC-02

Remote Control Transmitter

Mar 28, 2001

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter