FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Integrated Engineering BV/
  3. P4EHPROX-02

P4EHPROX-02Inductive proximity card reader

Integrated Engineering BV
Inductive proximity card reader - FCC ID P4EHPROX-02 - Integrated Engineering BV
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Aug 28, 2002
Application Purpose
Original Equipment
Date of Application
Aug 28, 2002
Equipment Note
Inductive proximity card reader
Frequency Range
0.12500000 - 0.12500000
Company
Integrated Engineering BV
Country
Netherlands

Documents & Files

Select a file to view

Users Manual

โ†—

Cover Letter(s)

โ†—
โ†—

External Photos

โ†—

ID Label/Location Info

โ†—

Internal Photos

โ†—

Test Report

โ†—

Test Setup Photos

โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

@@ PXOO7 ~1 The PXOO7 Proximity Card Reader has a slim door style mountable design to match any decor. The buried LED's and buzzer allow the PXOO7 Readers to be mounted indoors and out. The PXOO7 Reader Family accepts 4.75 to 14.25 Volts DC. The output formats like clock-and-data magstripe (ABA / ISO7811 ), Wiegand and a number of other formats are determined by the personalization of the card and are emitted without customizing the Reader. The 5 Volt DC capability allows the replacement of older reader systems without rewiring or pulling new cables. The PXOO7 Family offers high reliability, consistent read characteristics and low power consumption. Within the PXOO7 Proximity Reader Family also models with a RS232/RS422/RS485 interface are available for read and write operations. The PXOO7 Proximity Card Reader Family supports both the 125KHz and 13.56MHz technologies. Different models are available for EM4002, EM4050, HiTAG1 and 2, Mifare and I.Code silicon. Standard capabilities include Host system controlled red and green LED's and a buzzer. The PXOO7 Reader Family can be mounted on any surface without relevant performance degradation. Integrated Engineering is committed to bring non-propriety, open Radio Frequent Identification (RFID) systems to the market demonstrated with the PXOO7 Proximity Reader Family. Specifications Typical read range with an ISO Card PXO07BZ/HX HiTAG1, 2 5- 10 cm PXO07AZ EM4002, EM4050 5- 10 cm PXO07Z/MF Mifare 2 -3 cm PXO07Z/MFSNR Mifare serialnr. 2- 5 cm PXO07Z/ICSNR I.Code serialnr. 5- 15 cm Power Supply 4.75- 12.25 Volt DC Current requirements Average 50 mA Peak 100 mA Interface Inputs EMC Prot. 10Kohm pull-ups Outputs EMC Prot. open drain 0.5 A/max Dimensions 140 x 46 x 22 mm Material Black ABS housing with polyurethan potting Operating temperature -20ยฐ to 60ยฐ C Certifications EN50022, CE, FCC Cable Distance 25 meter. Recommended cable 8 x 0.35 conductor stranded overall shield or equivalent. Features Mullion mounting The PXOO7 Readers are designed to be unobtrusive and can be mounted on a door mullion. Indications When a proximity card is decoded successfully the with the card associated code is send to the Host system, the red LED flashes and the buzzer sounds a short 3KHz beep. Both LED's and the buzzer are also controllable by the Host system. Connections The PXOO7 Reader Family has a flexible and reliable connector interface. The space for the cable and the connector within the PXOO7 housing can be poured with silicone to withstand harsh environmental conditions. Interface Coding The PXOO7 Reader Family can operate with any facility, system or card coding scheme. The output format, contents and length are determined by the personalization of the card. Output formats like magstripe, Wiegand and several others are available. Security Depending on the model and the silicon used the PXOO7 Reader Family offers high security challenge response schemes to protect the RFID air interface against simulations of cards. Connector Assignments PXOO7BZ/HX PXOO7AZ PXOO7Z/MF PXOO7Z/MFSNR PXOO7Z/ICSNR 1 <;::J Red LED input 2 <;::J Green LED input 3 q Data / D1 4 q Clock / DO 5 <;::J Buzzer input 6 NC 7 <;::J Ground 8 <;::JPower PXOO7BZ/HX/RS232 PXOO7Z/MF/RS232 PXOO7Z/MFSNR/RS232 PXOO7Z/ICSN R/RS232 1 <:::J Red LED input 2 <:::J Green LED input i 3 q RS232 RTS (optiona~) 4 q RS232 TXD 5 <:::J RS232 CTS (optionaO 6 <:::J RS232 RXD 7 <:::J Ground 8 <:::J Power PXOO7BZ/HX/RS422 PXOO7Z/MF/RS422 PXOO7Z/MFSNR/RS422 PXOO7Z/ICSNR/RS422 1 ? Red LED input 2 ? Green LED input 3 c::> RS422 TXB 4 c::> RS422 TXA 5 ? RS422 RXB 6 ? RS422 RXA 7 ? Ground 8 ?Power Parts List 1) PXO07 Reader 4.75-12.25 VDC qty 1 2) Terminal Connector 8 pins qty 1 3) Mounting sticker qty 2 4) Installation sheet qty 1 5) K25 spacer plate (optional) qty 1 6) Cable, 8 x 0.35 conductor as required Installation instruction 1) Determine an appropriate position for the Reader and drill two holes for mounting the reader to the surface (see diagram). Make sure that enough room to connect the cable is allowed. Protect the cable against sharp edges and any damage from chaffing. 2) Remove the Terminal Connector 8 pins from the back of the Reader. Use a small flat head screwdriver to loosen off all of the terminals. The end of the cable should be prepared by cutting it back to expose the wires and each end should be twisted to eliminate any loose or frayed wires. 3) The wires should then be connected to the Reader inline with the Connector Assignments. 4) After wiring the reader and the Host system the Reader is ready to be tested. Apply power and present a Card to the Reader. The red LED should flash and the buzzer should beep indicating a read. If the Host system is connected to the red and green LED inputs these should follow the functionality of the Host system. 5) The Reader should now be secured to the surface using the appropriate fasteners and the stickers should be applied to cover the mounting holes. Mullion Mounting Integrated Engineering Amsterdam The Netherlands Telephone: +31 204620755 Fax: +31 204620756 Email: [email protected]$} WWW: http://www.iepr~x.com Ref: V1.2, 20/11/2000

Cover Letter(s)

TNO Electronic Products & Services (EPS) B.V. Nederlandse Organisatie voor toegepast-natuurwetenschappelijk onderzoek / Netherlands Organisation for Applied Scientific Research Smidshornerweg 18 P.O. Box 15 9822 ZG Niekerk The Netherlands www.tno.nl T +31 594 505005 F +31 594 504804 E [email protected] Subject Cover letter Date August 6, 2002 Our reference 02K0720 Your reference - Page 1 of 1 Our General Terms and Conditions, as filed at the Chamber of Commerce in Groningen, are applicable to all orders given to TNO Electronic Products & Services (EPS) B.V. TNO Electronic Products & Services (EPS) B.V. is registered at the Chamber of Commerce in Groningen with no. 27247331. Return address: P.O. Box 15, 9822 ZG Niekerk, The Netherlands Telefication B.V. Attn.: W. Blom Edisonstraat 12a 6902 PK Zevenaar The Netherlands Dear Mr. Blom, On behalf of our customer Integrated Engineering B.V., we hereby would like to apply for FCC certification of the following device: FCC ID : P4EHPROX-02 Brand : Integrated Engineering Model number : PX007Z/HX Description : Inductive proximity card reader operating on 125 kHz The following PDF files (exhibits) are electronically submitted: 1. Cover letter with request for FCC certification 2. Request for confidentiality 3. Form 731 4. Test reports in conformity with 47 CFR Part 15 5. Block diagram 6. Operational description 7. Bill of materials 8. Circuit diagram 9. Interior photographs 10. Exterior photographs 11. Test setup photographs 12. Label information 13. User manual Best regards, TNO Electronic Products & Services (EPS) B.V. P.A.J.M. Robben, B.Sc.E.E. Marketing Manager

Cover Letter(s)

TNO Electronic Products & Services (EPS) B.V. Nederlandse Organisatie voor toegepast-natuurwetenschappelijk onderzoek / Netherlands Organisation for Applied Scientific Research Smidshornerweg 18 P.O. Box 15 9822 ZG Niekerk The Netherlands www.tno.nl T +31 594 505005 F +31 594 504804 E [email protected] Subject Request for confidentiality Date August 6, 2002 Our reference 02K0719 Your reference - Page 1 of 1 Our General Terms and Conditions, as filed at the Chamber of Commerce in Groningen, are applicable to all orders given to TNO Electronic Products & Services (EPS) B.V. TNO Electronic Products & Services (EPS) B.V. is registered at the Chamber of Commerce in Groningen with no. 27247331. Return address: P.O. Box 15, 9822 ZG Niekerk, The Netherlands Telefication B.V. Attn.: W. Blom Edisonstraat 12a 6902 PK Zevenaar The Netherlands Dear Mr. Blom, Pursuant to section 0.457 of the FCC rules we herewith request the following exhibits, related to this application for FCC ID: P4EHPROX-02, to be withheld from public inspection and to be kept confidential. The contents of these exhibits may not be disclosed to other parties than Integrated Engineering B.V. and TNO Electronic Products & Services (EPS) B.V.: 1. Block diagram 2. Bill of materials 3. Schematics 4. Operational description The reason for this request for confidentiality is that the information contained in the exhibits as listed above has been classified as company confidential. Disclosure of any portion of this information to other parties would cause substantial competitive harm. Best regards, TNO Electronic Products & Services (EPS) B.V. P.A.J.M. Robben, B.Sc.E.E. Marketing Manager

External Photos

Testing and certification of, consultancy and research concerning, electronic and electric appliances, systems, installations and telecommunication systems TNO Electronic Products & Services (EPS) B.V. P.O. Box 15 9822 ZG Niekerk (NL) Smidshornerweg 18 9822 TL Niekerk (NL) Telephone: +31 594 505005 Telefax: +31 594 504804 E-mail: [email protected] Project number: 3555.p01 Page 1 of 7 EXTERIOR PHOTOGRAPHS OF AN INDUCTIVE PROXIMITY CARD READER, BRAND INTEGRATED ENGINEERING, TYPE PX007Z/HX. FCC listed Industry Canada : : 90828 IC3501 Description of EUT: Manufacturer: Brand mark: Type: FCC ID: Inductive proximity card reader Integrated Engineering B.V. Integrated Engineering PX007Z/HX P4EHPROX-02 Project number: 3555.p01 Page 2 of 7 Description of test item Test item : Inductive proximity card reader operating on 125 kHz Manufacturer : Integrated Engineering B.V. Brand : Integrated Engineering Type : PX007Z/HX Serial numbers : 0015.0112 Revision : n.a. Receipt number : 1 Receipt date : August 22, 2001 Applicant information Applicant's representative : Mr. R. Holslag Company : Integrated Engineering B.V. Address : Paasheuvelweg 20 Postal code : 1105 BJ City : Amsterdam PO-box : - Postal code : - City : - Country : The Netherlands Telephone number : +31 20 462 0700 Telefax number : +31 20 462 0758 This report is in conformity with NEN-EN-ISO/IEC 17025: 2000. This report shall not be reproduced, except in full, without the written permission of TNO Electronic Products & Services (EPS) B.V. The test results relate only to the item(s) tested. Description of EUT: Manufacturer: Brand mark: Type: FCC ID: Inductive proximity card reader Integrated Engineering B.V. Integrated Engineering PX007Z/HX P4EHPROX-02 Project number: 3555.p01 Page 3 of 7 Table of contents 1 Exterior photographs. .............................................................................................................................................................4 1.1 Top view.........................................................................................................................................................................4 1.2 Bottom view. ..................................................................................................................................................................5 1.3 Right/front view. ............................................................................................................................................................6 1.4 Left/front view................................................................................................................................................................7 Description of EUT: Manufacturer: Brand mark: Type: FCC ID: Inductive proximity card reader Integrated Engineering B.V. Integrated Engineering PX007Z/HX P4EHPROX-02 Project number: 3555.p01 Page 4 of 7 1 Exterior photographs. 1.1 Top view. Description of EUT: Manufacturer: Brand mark: Type: FCC ID: Inductive proximity card reader Integrated Engineering B.V. Integrated Engineering PX007Z/HX P4EHPROX-02 Project number: 3555.p01 Page 5 of 7 1.2 Bottom view. Description of EUT: Manufacturer: Brand mark: Type: FCC ID: Inductive proximity card reader Integrated Engineering B.V. Integrated Engineering PX007Z/HX P4EHPROX-02 Project number: 3555.p01 Page 6 of 7 1.3 Right/front view. Description of EUT: Manufacturer: Brand mark: Type: FCC ID: Inductive proximity card reader Integrated Engineering B.V. Integrated Engineering PX007Z/HX P4EHPROX-02 Project number: 3555.p01 Page 7 of 7 1.4 Left/front view.

ID Label/Location Info

The label as layed out above will be placed at the backside of the inductive proximity card reader, brand Integrated Engineering, type PX007Z/HX, operating on 125 kHz.

Internal Photos

Testing and certification of, consultancy and research concerning, electronic and electric appliances, systems, installations and telecommunication systems TNO Electronic Products & Services (EPS) B.V. P.O. Box 15 9822 ZG Niekerk (NL) Smidshornerweg 18 9822 TL Niekerk (NL) Telephone: +31 594 505005 Telefax: +31 594 504804 E-mail: [email protected] Project number: 3555.p05 Page 1 of 5 INTERIOR PHOTOGRAPHS OF AN INDUCTIVE PROXIMITY CARD READER, BRAND INTEGRATED ENGINEERING, TYPE PX007Z/HX. FCC listed Industry Canada : : 90828 IC3501 Description of EUT: Manufacturer: Brand mark: Type: FCC ID: Inductive proximity card reader Integrated Engineering B.V. Integrated Engineering PX007Z/HX P4EHPROX-02 Project number: 3555.p05 Page 2 of 5 Description of test item Test item : Inductive proximity card reader operating on 125 kHz Manufacturer : Integrated Engineering B.V. Brand : Integrated Engineering Type : PX007Z/HX Serial numbers : 0015.0112 Revision : n.a. Receipt number : 1 Receipt date : August 22, 2001 Applicant information Applicant's representative : Mr. R. Holslag Company : Integrated Engineering B.V. Address : Paasheuvelweg 20 Postal code : 1105 BJ City : Amsterdam PO-box : - Postal code : - City : - Country : The Netherlands Telephone number : +31 20 462 0700 Telefax number : +31 20 462 0758 This report is in conformity with NEN-EN-ISO/IEC 17025: 2000. This report shall not be reproduced, except in full, without the written permission of TNO Electronic Products & Services (EPS) B.V. The test results relate only to the item(s) tested. Description of EUT: Manufacturer: Brand mark: Type: FCC ID: Inductive proximity card reader Integrated Engineering B.V. Integrated Engineering PX007Z/HX P4EHPROX-02 Project number: 3555.p05 Page 3 of 5 Table of contents 1 Interior photographs. ............................................................................................................................................................... 4 1.1 Top view pcb. .................................................................................................................................................................. 4 1.2 Bottom view pcb.............................................................................................................................................................. 5 Description of EUT: Manufacturer: Brand mark: Type: FCC ID: Inductive proximity card reader Integrated Engineering B.V. Integrated Engineering PX007Z/HX P4EHPROX-02 Project number: 3555.p05 Page 4 of 5 1 Interior photographs. 1.1 Top view pcb. Description of EUT: Manufacturer: Brand mark: Type: FCC ID: Inductive proximity card reader Integrated Engineering B.V. Integrated Engineering PX007Z/HX P4EHPROX-02 Project number: 3555.p05 Page 5 of 5 1.2 Bottom view pcb.

Test Report

Testing and certification of, consultancy and research concerning, electronic and electric appliances, systems, installations and telecommunication systems TNO Electronic Products & Services (EPS) B.V. P.O. Box 15 9822 ZG Niekerk (NL) Smidshornerweg 18 9822 TL Niekerk (NL) Telephone: +31 594 505005 Telefax: +31 594 504804 E-mail: [email protected] Project number: 3555.001 Page 1 of 12 TEST REPORT CONCERNING THE COMPLIANCE OF AN INDUCTIVE PROXIMITY CARD READER, BRAND INTEGRATED ENGINEERING, TYPE PX007Z/HX, WITH 47 CFR PART 15 (2001-5-24). FCC listed Industry Canada : : 90828 IC3501 Test specification(s): Description of EUT: Manufacturer: Brand mark: Type: FCC ID: 47 CFR Part 15 (2001-5-24) Inductive proximity card reader Integrated Engineering B.V. Integrated Engineering PX007Z/HX P4EHPROX-02 Project number: 3555.001 Page 2 of 12 MEASUREMENT/TECHNICAL REPORT INTEGRATED ENGINEERING B.V. Model : PX007Z/HX FCC ID: P4EHPROX-02 December 20, 2001 This report concerns: Original grant/certification Class 2 change Verification Equipment type: Inductive proximity card reader operating on 125 kHz Deferred grant requested per 47 CFR 0.457(d)(1)(ii) ? Yes No n.a. Report prepared by: Name : P.A.J.M. Robben, B.Sc.E.E. Company name : TNO Electronic Products & Services (EPS) B.V. Address : Smidshornerweg 18 Postal code/city : 9822 ZG Niekerk Mailing address : P.O. Box 15 Postal code/city : 9822 TL Niekerk Country : The Netherlands Telephone number : + 31 594 505 005 Telefax number : + 31 594 504 804 E-mail : [email protected] The data taken for this test and report herein was done in accordance with 47 CFR Part 15 and the measurement procedures of ANSI C63.4-1992. TNO Certification EPS at Niekerk, The Netherlands, certifies that the data is accurate and contains a true representation of the emission profile of the Equipment Under Test (EUT) on the date of the test as noted in the test report. I have reviewed the test report and find it to be an accurate description of the test(s) performed and the EUT so tested. Date: December 20, 2001 Signature: O.H. Hoekstra TNO Electronic Products & Services (EPS) B.V. Test specification(s): Description of EUT: Manufacturer: Brand mark: Type: FCC ID: 47 CFR Part 15 (2001-5-24) Inductive proximity card reader Integrated Engineering B.V. Integrated Engineering PX007Z/HX P4EHPROX-02 Project number: 3555.001 Page 3 of 12 Description of test item Test item : Inductive proximity card reader operating on 125 kHz Manufacturer : Integrated Engineering B.V. Brand : Integrated Engineering Type : PX007Z/HX Serial number : 0015.0112 Revision : n.a. Receipt number : 1 Receipt date : August 22, 2001 Applicant information Applicant's representative : Mr. R. Holslag Company : Integrated Engineering B.V. Address : Paasheuvelweg 20 Postal code : 1105 BJ City : Amsterdam PO-box : n.a. Postal code : n.a. City : n.a. Country : The Netherlands Telephone number : +31 20 462 0700 Telefax number : +31 20 462 0758 Order number : n.a. Test(s) performed Location : Niekerk Test(s) started : September 6, 2001 Test(s) completed : September 19, 2001 Purpose of test(s) : Compliance with standard Test specification(s) : 47 CFR Part 15 (2001-5-24) Test engineer : T.E.T. Koning Project leader : P. de Beer Report written by : P.A.J.M. Robben, B.Sc.E.E. Report approved by : O.H. Hoekstra Report date : December 20, 2001 This report is in conformity with NEN-EN-ISO/IEC 17025: 2000. This report shall not be reproduced, except in full, without the written permission of TNO Electronic Products & Services (EPS) B.V. The test results relate only to the item(s) tested. Test specification(s): Description of EUT: Manufacturer: Brand mark: Type: FCC ID: 47 CFR Part 15 (2001-5-24) Inductive proximity card reader Integrated Engineering B.V. Integrated Engineering PX007Z/HX P4EHPROX-02 Project number: 3555.001 Page 4 of 12 Table of contents 1 General information ...............................................................................................................................................................5 1.1 Product description.........................................................................................................................................................5 1.1.1 Introduction. ...........................................................................................................................................................5 1.1.2 Choice of operating frequency. ..............................................................................................................................5 1.1.3 Operating principles. ..............................................................................................................................................5 1.2 Related submittal(s) and/or Grant(s) ..............................................................................................................................5 1.3 Tested system details......................................................................................................................................................5 1.4 Test methodology ...........................................................................................................................................................6 1.5 Test facility.....................................................................................................................................................................6 1.6 Product labelling.............................................................................................................................................................6 2 System test configuration .......................................................................................................................................................7 2.1 Justification ...................................................................................................................................................................โ€ฆ

Text truncated - open the document above for the full version.

Test Setup Photos

Testing and certification of, consultancy and research concerning, electronic and electric appliances, systems, installations and telecommunication systems TNO Electronic Products & Services (EPS) B.V. P.O. Box 15 9822 ZG Niekerk (NL) Smidshornerweg 18 9822 TL Niekerk (NL) Telephone: +31 594 505005 Telefax: +31 594 504804 E-mail: [email protected] Project number: 3555.p09 Page 1 of 7 47 CFR PART 15 TEST SETUP PHOTOGRAPHS OF AN INDUCTIVE PROXIMITY CARD READER, BRAND INTEGRATED ENGINEERING, TYPE PX007Z/HX. FCC listed Industry Canada : : 90828 IC3501 Description of EUT: Manufacturer: Brand mark: Type: FCC ID: Inductive proximity card reader Integrated Engineering B.V. Integrated Engineering PX007Z/HX P4EHPROX-02 Project number: 3555.p09 Page 2 of 7 Description of test item Test item : Inductive proximity card reader operating on 125 kHz Manufacturer : Integrated Engineering B.V. Brand : Integrated Engineering Type : PX007Z/HX Serial numbers : 0050-104 Revision : n.a. Receipt number : 1 Receipt date : August 22, 2001 Applicant information Applicant's representative : Mr. R. Holslag Company : Integrated Engineering B.V. Address : Paasheuvelweg 20 Postal code : 1105 BJ City : Amsterdam PO-box : - Postal code : - City : - Country : The Netherlands Telephone number : +31 20 462 0700 Telefax number : +31 20 462 0758 This report is in conformity with NEN-EN-ISO/IEC 17025: 2000. This report shall not be reproduced, except in full, without the written permission of TNO Electronic Products & Services (EPS) B.V. The test results relate only to the item(s) tested. Description of EUT: Manufacturer: Brand mark: Type: FCC ID: Inductive proximity card reader Integrated Engineering B.V. Integrated Engineering PX007Z/HX P4EHPROX-02 Project number: 3555.p09 Page 3 of 7 Table of contents 1 Radiated emission test setup...................................................................................................................................................4 1.1 Radiated emission test setup (front). ..............................................................................................................................4 1.2 Radiated emission test setup (back)................................................................................................................................5 2 Conducted emission test setup................................................................................................................................................6 2.1 Conducted emission test setup (front). ...........................................................................................................................6 2.2 Conducted emission test setup (back). ...........................................................................................................................7 Description of EUT: Manufacturer: Brand mark: Type: FCC ID: Inductive proximity card reader Integrated Engineering B.V. Integrated Engineering PX007Z/HX P4EHPROX-02 Project number: 3555.p09 Page 4 of 7 1 Radiated emission test setup. 1.1 Radiated emission test setup (front). Description of EUT: Manufacturer: Brand mark: Type: FCC ID: Inductive proximity card reader Integrated Engineering B.V. Integrated Engineering PX007Z/HX P4EHPROX-02 Project number: 3555.p09 Page 5 of 7 1.2 Radiated emission test setup (back). Description of EUT: Manufacturer: Brand mark: Type: FCC ID: Inductive proximity card reader Integrated Engineering B.V. Integrated Engineering PX007Z/HX P4EHPROX-02 Project number: 3555.p09 Page 6 of 7 2 Conducted emission test setup. 2.1 Conducted emission test setup (front). Description of EUT: Manufacturer: Brand mark: Type: FCC ID: Inductive proximity card reader Integrated Engineering B.V. Integrated Engineering PX007Z/HX P4EHPROX-02 Project number: 3555.p09 Page 7 of 7 2.2 Conducted emission test setup (back).

Contact Information

Applicant

Robert Holslag(Mr.)
[email protected]+31 20 462 0700Fax: +31 20 462 0758

Technical Contact

Integrated Engineering B.V.Robert Holslag
[email protected]+31 20 462 0700

Paasheuvelweg 20 ยท Amsterdam ยท Netherlands

Non-Technical Contact

Integrated Engineering B.V.Robert Holslag
[email protected]+31 20 462 0700

Test Firm

TUV Rheinland Nederland B.V.Ties E. T Koning
[email protected]31-594-505-005Fax: 31-594-504-804

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.125 MHz - 0.125 MHz-
Confidentiality
Long Term
Grant Notes
HiTAG 1 and 2 technology are supported.

Other Applications from Integrated Engineering BV

Inductive Proximity Card Reader - FCC ID P4E-SMARTPIN-8 - Integrated Engineering BV
P4E-SMARTPIN-8

Inductive Proximity Card Reader

Oct 03, 2007

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Card Reader and Fingerprint Scanner - FCC ID P4E-SMARTPIN-7 - Integrated Engineering BV
P4E-SMARTPIN-7

Card Reader and Fingerprint Scanner

Oct 03, 2007

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Inductive Proximity Card Reader - FCC ID P4E-SMARTPIN-5 - Integrated Engineering BV
P4E-SMARTPIN-5

Inductive Proximity Card Reader

Feb 19, 2007

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Inductive Proximity Card Reader - FCC ID P4E-SMARTPIN-4 - Integrated Engineering BV
P4E-SMARTPIN-4

Inductive Proximity Card Reader

Sep 06, 2006

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Inductive Proximity Card Reader - FCC ID P4E-SMARTPIN-3 - Integrated Engineering BV
P4E-SMARTPIN-3

Inductive Proximity Card Reader

Feb 12, 2006

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter